PubMed Health⌕ Search

PubMed · 1947316

Hardware and software artifacts in storage phosphor radiography.

Abstract

Hardware and software artifacts in digital radiographs acquired with storage phosphor systems can seriously impair image quality and imitate or mask abnormalities. These artifacts are caused by image plate, image reader, and laser printer defects; faulty image readout; processing errors; and unsharp masking. The artifacts can simulate calcifications and pneumothoraces or conceal low-contrast ill-defined lesions and subtle lesions along opacity interfaces. Hardware artifacts need to be recognized and properly traced to repair the system or improve its maintenance. Artifacts due to software characteristics and image post-processing must also be identified to ensure adequate system handling and adjustment of postprocessing algorithms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J W Oestmann, M Prokop, C M Schaefer, M Galanski. 1991. Hardware and software artifacts in storage phosphor radiography.. https://doi.org/10.1148/radiographics.11.5.1947316

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗