Publications and source records attributed to C Plathow.

15 recordsLinked to original sources

[Visualization of pulmonary nodules with magnetic resonance imaging (MRI)].

Visualization of pulmonary nodules using magnetic resonance imaging (MRI) plays a minor role compared with computed tomography (CT). Technical developments made it possible to apply MRI more and more frequently in functional imaging. Imaging of the motion of pulmonary nodules during respiration, e.g., to optimize high precision therapy techniques, is a new field of research. This paper describes developments in analysis and visualization of pulmonary nodules during respiration using MRI. Besides actual 2D techniques new 3D techniques to quantify motion of pulmonary nodules during respiration are presented.

Humans↗

Reproducible Simulation of Respiratory Motion in Porcine Lung Explants.

PURPOSE: To develop a model for exactly reproducible respiration motion simulations of animal lung explants inside an MR-compatible chest phantom. MATERIALS AND METHODS: The materials included a piston pump and a flexible silicone reconstruction of a porcine diaphragm and were used in combination with an established MR-compatible chest phantom for porcine heart-lung preparations. The rhythmic inflation and deflation of the diaphragm at the bottom of the artificial thorax with water (1 - 1.5 L) induced lung tissue displacement resembling diaphragmatic breathing. This system was tested on five porcine heart-lung preparations using 1.5T MRI with transverse and coronal 3D-GRE (TR/TE = 3.63/1.58, 256 x 256 matrix, 350 mm FOV, 4 mm slices) and half Fourier T2-FSE (TR/TE = 545/29, 256 x 192, 350 mm, 6 mm) as well as multiple row detector CT (16 x 1 mm collimation, pitch 1.5, FOV 400 mm, 120 mAs) acquired at five fixed inspiration levels. Dynamic CT scans and coronal MRI with dynamic 2D-GRE and 2D-SS-GRE sequences (image frequencies of 10/sec and 3/sec, respectively) were acquired during continuous "breathing" (7/minute). The position of the piston pump was visually correlated with the respiratory motion visible through the transparent wall of the phantom and with dynamic displays of CT and MR images. An elastic body splines analysis of the respiratory motion was performed using CT data. RESULTS: Visual evaluation of MRI and CT showed three-dimensional movement of the lung tissue throughout the respiration cycle. Local tissue displacement inside the lung explants was documented with motion maps calculated from CT. The maximum displacement at the top of the diaphragm (mean 26.26 [SD 1.9] mm on CT and 27.16 [SD 1.5] mm on MRI, respectively [p = 0.25; Wilcoxon test]) was in the range of tidal breathing in human patients. CONCLUSION: The chest phantom with a diaphragmatic pump is a promising platform for multi-modality imaging studies of the effects of respiratory lung motion.

Animals↗

Time-resolved echo-shared parallel MRA of the lung: observer preference study of image quality in comparison with non-echo-shared sequences.

The aim of this study was to evaluate the image quality of time-resolved echo-shared parallel MRA of the lung. The pulmonary vasculature of nine patients (seven females, two males; median age: 44 years) with pulmonary disease was examined using a time-resolved MRA sequence combining echo sharing with parallel imaging (time-resolved echo-shared angiography technique, or TREAT). The sharpness of the vessel borders, conspicuousness of peripheral lung vessels, artifact level, and overall image quality of TREAT was assessed independently by four readers in a side-by-side comparison with non-echo-shared time-resolved parallel MRA data (pMRA) previously acquired in the same patients. Furthermore, the SNR of pulmonary arteries (PA) and veins (PV) achieved with both pulse sequences was compared. The mean voxel size of TREAT MRA was decreased by 24% compared with the non-echo-shared MRA. Regarding the sharpness of the vessel borders, conspicuousness of peripheral lung vessels, and overall image quality the TREAT sequence was rated superior in 75-76% of all cases. If the TREAT images were preferred over the pMRA images, the advantage was rated as major in 61-71% of all cases. The level of artifacts was not increased with the TREAT sequence. The mean interobserver agreement for all categories ranged between fair (artifact level) and good (overall image quality). The maximum SNR of TREAT did not differ from non-echo-shared parallel MRA (PA: TREAT: 273+/-45; pMRA: 280+/-71; PV: TREAT: 273+/-33; pMRA: 258+/-62). TREAT achieves a higher spatial resolution than non-echo-shared parallel MRA which is also perceived as an improved image quality.

Adolescent↗

Monitoring of liver metastases after stereotactic radiotherapy using low-MI contrast-enhanced ultrasound--initial results.

The purpose of this study was to monitor liver metastases after radiotherapy using contrast-enhanced ultrasound (CEUS). In 15 patients, follow-up examinations after stereotactic, single-dose radiotherapy were performed using CEUS (low mechanical index (MI), 2.4-ml SonoVue) and computed tomography (CT). Besides tumor size, the enhancement of the liver and the metastases was assessed at the arterial, portal venous, and delayed phases. The sizes of the tumor and of a perifocal liver reaction after radiotherapy measured with CEUS significantly correlated with those measured at CT (r=0.93, p<0.001). CEUS found a significant reduction of the arterial vascularization in treated tumors (p<0.05). In the arterial phase, the perifocal liver tissue was hypervascularized compared to the treated tumor (p<0.001); in the late phase, it was less enhanced than the liver (p<0.001) and more than the tumor (p<0.01). The perifocal liver reaction was also seen in CT, but with a variable enhancement at the arterial (50% hyperdense compared to normal liver tissue), venous, or delayed phase (each with 70% hyperdense reactions). CEUS allows for the assessment of tumor and liver perfusion, in addition to morphological tumor examination, which was comparable with CT. Thus, changes of tumor perfusion, which may indicate tumor response, as well as the perifocal liver reaction after radiotherapy, which must be differentiated from perifocal tumor growth, can be sensitively visualized using CEUS.

Contrast Media↗

[Imaging of sacral chordoma: comparison between MRI and CT].

AIM: Sacral chordoma is a primarily benign tumor with a high tendency to recur. A correct definition of tumor volume is a significant prognostic factor. We compared the value of CT and MRI in diagnosing a sacral chordoma. METHODS: 31 patients with a histologically proven sacral chordoma were included in this study. Following parameters were analyzed by two independent radiologists: septation, signs of blood and ossification in the tumor tissue, contrast enhancement, maximal tumor diameter, infiltration of the soft tissue, the dural salc and the cauda equina and multifocality. RESULTS: In CT all chordomas showed a hypodensity to the normal tissue and in MRI a hyperintensity on T2w images with a low level of contrast enhancement. On the basis of the more precise soft tissue contrast of MRI compared with CT, MRI was significantly more accurate in all tested parameters (p <0.05) besides in detecting tumor ossification. In CT tumor volume was frequently underestimated. CONCLUSION: MRI in sacral chordoma is an essential tool in the pretherapeutic diagnostic regimen and in a state of relapse.

Adult↗

[Teleradiology: economic research analysis of CT investigations in a small hospital].

PURPOSE: To evaluate, discuss and compare economic aspects of teleradiological applications in CT examinations in a small hospital. Scenario (1): CT examination by an extern institution including transport of a patient. Szenario (2): External consultation of an internal CT examination (teleradiology according to ROV). Scenario (3): Complete in-house radiology department. To evaluate economic aspects of teleradiology service providers. MATERIALS AND METHODS: Costs have been separated into fixed and variable costs in a model. Total costs of 500 CT examinations per year have been calculated for the three scenarios. A break-even analysis has been performed to determine the necessary/minimal number of CTs per year for economical advantages. The number of CT consultations for teleradiology service providers to make profit has been calculated. RESULTS: Scenario (1): This is the most cost-effective scenario for 500 CTs per year, but most time-consuming. Beyond 548 CTs per year using a single slice CT and 965 CTs per year using a multislice CT the teleradiology scenario [scenario (2)] is most cost-effective. Beyond 1065 CTs per year an in-house radiology department [scenario (3)] is economically reasonable. On the basis of 30 Euros per CT consultation a teleradiology service providing system will be profitable starting from 322 CT consultations per year. CONCLUSION: Teleradiology applications are economically reasonable in a wide range in small hospitals. CT teleradiology services can also be provided on a cost-effective basis at a reachable number of consultations.

Cost-Benefit Analysis↗

Quantitative analysis of lung and tumour mobility: comparison of two time-resolved MRI sequences.

The purpose of this study was to describe the use of parallel imaging technique (PAT) using dynamic MRI in lung and tumour mobility during the breathing cycle. 20 patients with stage I non-small cell lung carcinoma were investigated using two dynamic gradient echo sequences with PAT (TrueFISP (fast imaging with steady precession), and fast low angle shot (FLASH). Craniocaudal distance from the apex to the diaphragm of the thorax and tumour mobility during the breathing cycle were measured. Signal-to-noise ratio (SNR) of the tumour was determined. In spite of the different temporal resolutions both trueFISP and FLASH sequence proved to be adequate to continuously measure lung motion and tumour mobility. SNR of the tumour was significantly higher using the trueFISP sequence than FLASH sequence (20.7+/-3.6 vs 5.8+/-2.3, p<0.01). Mobility of the tumour bearing hemithorax was significantly lower compared with the non-tumour bearing hemithorax (p<0.05). Dynamic MRI using PAT allows for continuous quantitative documentation of tumour mobility and lung motion. Because of the higher SNR, trueFISP sequence provides a better delineation of intrapulmonary lesions with a sufficient temporal resolution.

Aged↗

[MRT of bronchial carcinomas].

Compared to computed tomography (CT), magnetic resonance imaging (MRI) only plays a minor role for the imaging of lung cancer. Among the reasons are technical limitations, such as longer acquisition times or inferior spatial resolution, as well as unfavourable tissue characteristics which cause a low signal-to-noise ratio of the lung parenchyma. However, MRI is a valuable tool for staging lung cancer and may in some cases even be considered the method of choice. The following review illustrates the role of MRI for the diagnosis of lung cancer using current MR-techniques. In particular, the potential of MRI for TNM-staging, new technical developments (e. g. parallel MRI), and the application of functional MRI of the chest are described.

Carcinoma, Bronchogenic↗

[Contrast-enhanced 3D MR perfusion of the lung: application of parallel imaging technique in healthy subjects].

PURPOSE: Evaluation of lung perfusion by contrast-enhanced 3D MRI using partial parallel imaging techniques. MATERIALS AND METHODS: Eight healthy volunteers were examined using a contrast-enhanced dynamic FLASH 3D sequence with partial parallel imaging technique at 1.5 T MRI with a TA of 1.5 sec. The whole lung was covered by 36 coronal slices. A ventral, middle and dorsal slice of each lung was manually segmented and signal-to-time curves were computed. For absolute quantification of blood flow through the right and left pulmonary artery, phase-contrast flow measurements were performed. RESULTS: No significant difference was found between the signal intensity in the right (8.9 +/- 2.6) and left (8.0 +/- 3.5) lung, corresponding to a left-to-right signal intensity ratio of 0.9. A significantly higher signal intensity was found in the dorsal regions of the lungs (p = 0.01) compared to the ventral regions. The time to peak of the signal intensity was significantly shorter in the dorsal (15.3 sec) and middle (15.7 sec) regions of the lungs (p = 0.03 and p = 0.04, respectively) than in the ventral regions (16.3 sec). The ratio between blood flow through the left (2.2 L/min) and right (2.7 L/min) lung was 0.84. CONCLUSION: Partial parallel image acquisition can assess the perfusion of the lungs at high temporal resolution. The perfusion is slightly higher on the right than on the left. The signal increases faster and has a higher peak in the dorsal lung regions.

Adolescent↗

[Metabolic imaging to follow stereotactic radiation of gliomas -- the role of 1H MR spectroscopy in comparison to FDG-PET and IMT-SPECT].

PURPOSE: To evaluate the clinical value of 1H MR spectroscopy (1H MRSI) for follow-up of irradiated glioma compared to positron emission tomography (PET) with [18F]-2-fluoro-deoxy-D-glucose (FDG-PET) and single photon emission tomography with [123I]-a-methyl-L-tyrosine (IMT-SPECT). MATERIALS AND METHODS: Twenty-four patients with irradiated gliomas were examined using 1H MRSI (2D spectroscopic imaging; PRESS; TE = 135 msec; 1.5T Magnetom Vision, Siemens; Voxel size 9 x 9 x 15 mm (3)). MR spectra (n = 233) were evaluated in areas suspicious of tumor (n = 86) as well as in healthy appearing brain tissue (n = 147). Relative signal intensity ratios of choline (Cho), creatine (Cr) and N-acetyl-aspartate (NAA) were calculated. PET scans (n = 19) were performed with 200 - 250 MBq FDG, IMT-SPECT examinations (n = 14) with 200 - 250 mBq IMT. Based on clinical and MRI/CT, follow-up lesions were classified as either neoplastic [PT] or non-neoplastic [nPT]. RESULTS: True positive results for the diagnosis of PT/nPT were 88/89 % (1H MRSI), 73/100 % (PET) and 100/75 % (SPECT). Cho/Cr showed highly significant changes for PT. Determinating a correlation between Cho, Cr, NAA and IMT-SPECT as well as FDG-PET was not possible because of different location of maximum tracer uptake and acquired 2D 1H MRSI. CONCLUSION: IMT-SPECT seems to be superior to detect tumor progression in irradiated gliomas. 1H MRSI was more suitable than FDG-PET to differentiate between recurrence and radiation-induced changes. FDG-PET plays a role as sensitive method for detecting high-grade tumors. PET and SPECT allowed the examination of the entire tumor including surrounding brain tissue with higher spatial resolution than the acquired 2D 1H MRSI. A main limitation of our study was that only 2D 1H MRSI was used, with only parts of the tumor evaluated. The use of 3D MR spectroscopic imaging may further increase the diagnostic accuracy.

Aged↗

Quantitative analysis of pulmonary perfusion using time-resolved parallel 3D MRI - initial results.

PURPOSE: To assess the use of time-resolved parallel 3D MRI for a quantitative analysis of pulmonary perfusion in patients with cardiopulmonary disease. MATERIALS AND METHODS: Eight patients with pulmonary embolism or pulmonary hypertension were examined with a time-resolved 3D gradient echo pulse sequence with parallel imaging techniques (FLASH 3D, TE/TR: 0.8/1.9 ms; flip angle: 40 degrees; GRAPPA). A quantitative perfusion analysis based on indicator dilution theory was performed using a dedicated software. RESULTS: Patients with pulmonary embolism or chronic thromboembolic pulmonary hypertension revealed characteristic wedge-shaped perfusion defects at perfusion MRI. They were characterized by a decreased pulmonary blood flow (PBF) and pulmonary blood volume (PBV) and increased mean transit time (MTT). Patients with primary pulmonary hypertension or Eisenmenger syndrome showed a more homogeneous perfusion pattern. The mean MTT of all patients was 3.3 - 4.7 s. The mean PBF and PBV showed a broader interindividual variation (PBF: 104 - 322 ml/100 ml/min; PBV: 8 - 21 ml/100 ml). CONCLUSION: Time-resolved parallel 3D MRI allows at least a semi-quantitative assessment of lung perfusion. Future studies will have to assess the clinical value of this quantitative information for the diagnosis and management of cardiopulmonary disease.

Acute Disease↗

[Radiotherapy planning for paraspinal tumors with CT-myelography].

BACKGROUND AND AIM: Artifacts due to metal implants are an important problem in diagnostic radiology and radiotherapy planning in tumors such as chordoma of the spine. A strict differentiation between target and radiosensitive structures e.g. spinal cord is absolutely essential for high-dose radiotherapy. Up to now CT and MRI techniques have provided only limited image quality in such situations. We introduce an approach to facilitate segmentation by using the technique of CT-myelography for radiation treatment. PATIENT AND METHOD: A 48-year-old woman with multiple inoperable relapses of a chordoma in the lumbar spine and extensive metal instrumentation in this area was given to radiotherapy using IMRT-technique (intensity modulated). MRI- and CT-planning images did not allow differentiation between myelon, cauda equina, dural sac and tumor. In this situation we performed a CT-myelography with the patient in treatment position. RESULT: CT-myelographic images enabled precise differentiation between myelon, cauda equina and intraspinal tumor. A substantial improvement of the segmentation of the spinal cord was obtained. There was no compression of the dural sac along the spine. This information provided the basis for a precise radiotherapy planning in IMRT-technique. CONCLUSION: In situations where CT- and MRI-techniques are not able to generate precise images which allow differentiation between tumor, myelon and cauda equina because of metal artifacts, CT-myelography is a promising technique which may help the diagnostic radiologist and radiation oncologist in planning radiotherapy.

Humans↗

Replacement of troponin-I in slow-twitch skeletal muscle alters the effects of the calcium sensitizer EMD 53998.

We extracted troponin-I (TnI) from skinned rat and rabbit soleus muscle fibres using a modification of the method described by Strauss et al. (FEBS Lett 310:229-234, 1992) for replacement of TnI in cardiac preparations. Incubation of soleus muscle fibres with 10 mmol/l vanadate virtually completely abolished the Ca2+dependence of force. Immunoblot analysis revealed that more than 80% of TnI had been extracted from the preparations. The Ca2+dependence of force was restored by incubation with a complex of cardiac TnI (cTnI) and troponin-C (cTnC). We examined the effects of the Ca2+-sensitizing compound EMD 53998 on isometric tension in native porcine cardiac and rabbit soleus skinned fibres as well as soleus in which the endogenous slow skeletal TnI (ssTnI) had been replaced by cTnI (soleus-cTnI). It was found that 10 micromol/l EMD 53998 in native soleus increased maximum Ca2+-activated force to 120+/-1.4% of control. In soleus-cTnI fibres, maximum force was increased to only 105+/-0.9%, which was similar to the effect observed in cardiac muscle (108+/-0.6%). In cardiac muscle, 10 micromol/l EMD 53998 induced a leftward shift of the pCa-tension relation by 0.65 log units. In native soleus, DeltapCa was only 0.40. Again, the effect of EMD 53998 on soleus-cTnI (DeltapCa=0.56) more closely resembled the response found in cardiac muscle than that observed in native soleus muscle. The apparent TnI-isoform dependence of the effects elicited by EMD 53998 suggests that its actions are modulated by the regulatory proteins of the thin filament.

Animals↗