Evaluation of a hybrid pixel detector for electron microscopy.

We describe the application of a silicon hybrid pixel detector, containing 64 by 64 pixels, each 170 microm(2), in electron microscopy. The device offers improved resolution compared to CCDs along with faster and noiseless readout. Evaluation of the detector, carried out on a 120 kV electron microscope, demonstrates the potential of the device.

Electrons↗

Feasibility of damage control surgery in the management of military combat casualties.

Unique and expanded applications of staged operative management are undergoing careful evaluation in many civilian level I trauma centers under the rubric of damage control surgery. Recently there have been advocates for its broad application to the early management of critically injured combat casualties. However, the enormous logistic requirements for such strategies are contrary to the demands of the usual wartime scenario. On the basis of experience in civilian trauma centers and combat casualty management, we question the suggested extensive role of damage control surgery during wartime. Each decision point in damage control surgery should be analyzed as it is altered (sensitivity analysis) by conditions of war. It is unwise to adopt such indications unchanged from current civilian trauma policy.

Abdominal Injuries↗

The utility of routine frozen section examination for intraoperative diagnosis of thyroid cancer.

BACKGROUND: The value of routine frozen section examination for intraoperative diagnosis of thyroid cancer and determination of extent of thyroidectomy is controversial and needs to be evaluated on an institution to institution basis. METHODS: A prospective evaluation of 76 patients with nodular thyroid disease who had an adequate fine needle aspiration biopsy (FNAB) underwent thyroidectomy with routine thyroid frozen section examination. A direct comparison of FNAB and frozen section examination, along with a cost benefit analysis of frozen section examination, was completed. RESULTS: The thyroid pathology was carcinoma in 24, follicular adenoma in 24, multinodular goiter in 24, thyroiditis in 3, and a cyst in 1 patient. The sensitivity, specificity, and accuracy of frozen section examination were 93%, 100%, and 97%, respectively, compared with 88%, 89%, and 91% for FNAB (P > 0.05). Diagnosis was deferred in 38 patients (50%) in whom frozen section examination showed a follicular neoplasm. One to 6 frozen section examinations were obtained per patient with alteration in intraoperative management in only 2 patients (3%) at a charge of $246 to $606 per patient and a total charge of $26,040. CONCLUSION: In patients with an adequate FNAB, frozen section examination rarely affected intraoperative decision making in thyroid surgery and its routine use was not cost effective.

Biopsy, Needle↗

A side-entry cold holder for cryo-electron microscopy.

A side-entry cold holder for cryo-electron microscopy has been constructed which can be used with no loss of image resolution or contrast at 3.4 A resolution compared to the normal room-temperature holder. A description is presented of some of the ideas and tests which we have developed during its construction and are included in the design, together with a briefer outline of the remaining limitations.

Cryopreservation↗

A cold stage for the Philips EM300 electron microscope.

A cold stage has been constructed for the Philips EM300 (and EM301) electron microscopes for investigating the structure of frozen-hydrated biological specimens. The stage entails minimal alterations to the instrument and is capable of a resolution better than 10 A at the normal operating temperature of -120 degrees C. Frozen specimens can be readily exchanged without condensation or warming up, and maintained in the stage over periods of several hours without detectable deterioration.

Freezing↗