PubMed Health⌕ Search

Biomedical subjects

Carl J Seliskar

Publications and source records attributed to Carl J Seliskar.

17 recordsLinked to original sources

Highly oxidizing excited states of Re and Tc complexes.

Like the Re analogue, the ligand-to-metal charge transfer (LMCT) excited-state of [Tc(dmpe)3]2+ (dmpe is bis-1,2-(dimethylphosphino)ethane) is luminescent in solution at room temperature. Surprisingly, both [M(dmpe)3]2+* species have extremely large excited-state potentials (ESPs) as oxidants-the highest for any simple coordination complex of a transition metal. Furthermore, this potential is available using a photon of visible light (calculated for M = Re(Tc); E1/2* = +2.61(2.52) V versus SCE; lambdamax = 526(585) nm). Using a Rehm-Weller analysis with a series of aromatic hydrocarbons as electron-transfer quenchers, E1/2(Re2+*/Re+) has been determined to be 2.58 V, in good agreement with the calculated value. Both [M(dmpe)3]2+* species are quenched by chloride ion and both can function as excited-state oxidants in water solution.

Organometallic Compounds↗

Analytical performance of polymer-based microfluidic devices fabricated by computer numerical controlled machining.

A study comparing the electrophoretic separation performance attainable from microchips molded by masters fabricated using conventional CNC machining techniques with commercial microchips, wire imprinted microchips, and microchips from LIGA molding devices is presented. An electrophoresis-based detection system using fluorescence microscopy was used to determine the analytical utility of these microchips. The separation performance of CNC microchips was comparable to commercially available microchips as well as those fabricated from LIGA masters. The important feature of the CNC machined masters is that they have rapid design-to-device times using routinely available machining tools. This low-cost prototyping approach provides a new entry point for researchers interested in thermoplastic microchips and can accelerate the development of polymer-based lab-on-a-chip devices.

Computer-Aided Design↗

Luminescence from the trans-dioxotechnetium(V) chromophore.

The luminescence of trans-[TcO2(L)4]+ (L = pyridine (py) or picoline (pic)) and trans-[TcO2(CN)4]3- at room and low temperature is described and represents the first example of room temperature excited-state luminescence observed for Tc complexes. At room temperature, the complexes exhibited broad luminescence with emission maxima ranging from 745 to 780 nm. Analogous to the Re complexes (emission at 635-655 nm), the low-temperature emission spectra of microcrystalline samples of [TcO2(py)4]BPh4 and [TcO2(pic)4]BPh4 display the characteristic progressions of the symmetric O=Tc=O and Tc-L stretching modes. DFT/TDDFT calculations were performed on the trans-[MO2(L)4]+ (M = Re, Tc) congeners and predicted the dioxotechnetium emission to be 0.41 eV lower in energy than its Re analogue. Low-temperature lifetimes (8 K) ranging from 15 to 1926 mus for the series of Tc complexes are consistent with the Re analogues.

Journal Article↗

The autofluorescence of plastic materials and chips measured under laser irradiation.

Plastic materials have the potential to substitute for glass substrates used in microfluidic and microTAS systems adding flexibility in materials' choices. Optical quality plastic materials with a low autofluorescence are crucial for optimal detection by fluorescence and laser induced fluorescence techniques. This paper summarizes a series of optical investigations on commercially available plastic chip materials (PMMA, COC, PC, PDMS) and chips made from those materials. Intrinsic optical constants of plastic materials-refractive index for bulk materials-determined by spectroscopic ellipsometry and transmission spectroscopy in the visible range are presented. The laser-induced autofluorescence of materials and chips was assessed at four laser wavelengths, namely, 403, 488, 532 and 633 nm. Considerable bleaching of the autofluorescence was observed under continuous laser illumination. Overall, the longer wavelength laser excitation sources yielded less autofluorescence. PDMS exhibited the least autofluorescence and was comparable to BoroFloat glass. In all cases, chips exhibited slightly higher autofluorescence than the raw plastic materials from which they had been made.

Equipment Failure Analysis↗

Estimation of pK(a) values using microchip capillary electrophoresis and indirect fluorescence detection.

Microchip capillary electrophoresis (CE), coupled with indirect fluorescence detection was investigated for estimating the pK(a) values of non-fluorescent compounds. The CE method is based on the differences in electrophoretic mobility of the analyte as a function of the pH of the running buffer. Nine compounds were tested, including several of pharmaceutical importance, with pK(a) values from 10.3 to 4.6. All buffers contained 5-TAMRA as the fluorescent probe for indirect detection. Calculated pK(a) values agreed well with literature values obtained by traditional methods, differing not more than 0.2 from the literature value. The current work on single lane chips demonstrates the principle of microchip CE with indirect detection as a viable method for estimating pK(a) values. However, increased throughput will be required using a multilane chip to enable the approach to be used practically.

Aniline Compounds↗

Dynamic in situ spectroscopic ellipsometry of the reaction of aqueous iron(II) with 2,2'-bipyridine in a thin Nafion film.

Dynamic in situ spectroscopic ellipsometry studies of the chemical reaction between ferrous ion and 2,2'-bipyridine (bpy) in a thin Nafion film are presented. A simple prototype system composed of a thin Nafion film on a glass substrate was used throughout the work. The reaction was detected by optically monitoring the formation of the strongly absorbing complex ion, Fe(bpy)3(2+) (epsilon 520 = 7.70 x 10(3) M(-1) cm(-1) in 0.1 M NaCl). The changes in film optical constants, n and k, and the thickness upon exposure of it to various solutions were monitored in a flow cell with the film on the backside of the substrate relative to the interrogation by light. A "step-by-step" approach was used to isolate the component parts of the system in which the film was consecutively exposed to solutions in the following order: supporting electrolyte, bpy, and, last, ferrous iron solution. The optical properties of the materials were quantitatively described before and during mass transport within the film by modeling using the appropriate multilayer optical models, i.e., the Cauchy equation for nonabsorbing media and the Urbach and Tauc-Lorentz (oscillator) functions for a film that absorbed. The experiments done allowed study of the diffusion in the film and the chemical reactions that are important in the sensing scheme for ferrous iron. Ligand (bpy) diffusion followed a two-stage diffusion mechanism described by a Berens-Hopfenberg model for incremental sorption (D25 = 7.04 x 10(-13) cm2 s(-1)). The stabilities of the appropriate systems, i.e., Nafion film with bpy, iron, and iron complex, were studied by exposing equilibrated films to circulating supporting electrolyte solutions. The measurements gave important insights into a set of film chemical reactions and, in turn, selective film dynamics. This work exemplifies the usefulness of spectroscopic ellipsometry in monitoring the kinetics of a chemical reaction in situ, as well as the changes in the film physical properties under dynamic conditions.

Journal Article↗

Amperometric determination of live Escherichia coli using antibody-coated paramagnetic beads.

Detecting and enumerating fecal coliforms, especially Escherichia coli, as indicators of fecal contamination, are essential for the quality control of supplied and recreational waters. We have developed a sensitive, inexpensive, and small-volume amperometric detection method for E. coli beta-galactosidase by bead-based immunoassay. The technique uses biotin-labeled capture antibodies (Ab) immobilized on paramagnetic microbeads that have been functionalized with streptavidin (bead-Ab). The bead-Ab conjugate captures E. coli from solution. The captured E. coli is incubated in Luria Bertani (LB) broth medium with the added inducer isopropyl beta-D: -thiogalactopyranoside (IPTG). The induced beta-galactosidase converts p-aminophenyl beta-D: -galactopyranoside (PAPG) into p-aminophenol (PAP), which is measured by amperometry using a gold rotating disc electrode. A good linear correlation (R2 = 0.989) was obtained between log cfu mL(-1) E. coli and the time necessary to product a specific concentration of PAP. Amperometric detection enabled determination of 2x10(6) cfu mL(-1) E. coli within a 30 min incubation period, and the total analysis time was less than 1 h. It was also possible to determine as few as 20 cfu mL(-1) E. coli under optimized conditions within 6-7 h. This process may be easily adapted as an automated portable bioanalytical device for the rapid detection of live E. coli.

Aminophenols↗

Estimation of logP(ow) values for neutral and basic compounds by microchip microemulsion electrokinetic chromatography with indirect fluorimetric detection (muMEEKC-IFD).

Microchip microemulsion electrokinetic chromatography with indirect fluorimetric detection (muMEEKC-IFD) was used to obtain logP octanol/water (logP(ow)) values for neutral and basic compounds. Six compounds, with logP(ow) values between 0.38 and 5.03, were used to create a calibration curve relating the log of retention factors (logk) obtained from muMEEKC-IFD with the known logP(ow) values. The logP(ow) values for six additional compounds were determined using the logk values obtained by muMEEKC-IFD and the linear relationship between logP(ow) and logk established for the standard compounds. The muMEEKC-IFD buffer was composed of 50 mM 3-[cyclohexylamino]-1-propane-sulfonic acid (CAPS) buffer (pH 10.4) containing 1.2% n-heptane (v/v), 2% sodium dodecylsulfate (w/v), 8% 1-butanol (v/v) and 4 microM 5-carboxytetramethyl-rhodamine (TAMRA) as the fluorophore probe for indirect detection. The muMEEKC-IFD provided an accurate method for estimating logP(ow) values and also a means for analyzing compounds that are non-fluorescent.

Calibration↗

An online fiber-optic UV-visible detector for continuous free-flow electrophoresis.

A PC-controlled, scanning online UV detector for continuous free-flow electrophoresis (CFFE) was designed to allow for single UV wavelength monitoring across a 1-D array of 48 longitudinal flow cells interfaced to a CFFE apparatus. In the detection scheme, the UV light is sequentially passed through each of the flow cells. The design integrates online acquisition of absorbance spectra of components separated by CFFE. Benzoic acid standard solutions were used to examine the performance of the detector. Chloroquine diphosphate and 4-nitrophenol were used as test solutes to determine the detector's ability to distinguish analytes separated in the CFFE.

Electrophoresis↗

Spectroelectrochemical sensing based on multimode selectivity simultaneously achievable in a single device. 17. Improvement in detection limits using ultrathin perfluorosulfonated ionomer films in conjunction with continuous sample flow.

We report herein an attenuated total reflectance (ATR) absorbance-based spectroelectrochemical sensor for tris(2,2'-bipyridyl)ruthenium(II) ion [Ru(bpy)(3)(2+)] that employs ultrathin (24-50 nm) Nafion films as the charge-selective layer. This film serves to sequester and preconcentrate the analyte at the optically transparent electrode surface such that it can be efficiently detected optically via electrochemical modulation. Our studies indicate that use of ultrathin films in tandem with continuous flow of sample solution through the cell compartment leads to a 100-500-fold enhancement in detection limit (10 nM) compared to earlier absorbance-based spectroelectrochemical sensors ( approximately 1-5 microM); markedly shorter analysis times also result. We report the dependence of the measured absorbance on sample flow rate and Nafion film thickness, and also provide calibration curves that illustrate the linear range and detection limits of the sensor using a 24 nm film at a constant sample flow rate of 0.07 mL/min.

Journal Article↗

Spectroelectrochemical sensing based on attenuated total internal reflectance stripping voltammetry. 3. Determination of cadmium and copper.

The optical and electrochemical properties of metallic films on ITO surfaces resulting from deposition of copper and cadmium were monitored by stripping voltammetry-attenuated internal reflectance spectroscopy. The voltammetric or optical responses of both metals were examined with respect to solution conditions such as pH and presence of dissolved oxygen. The morphologies of these films were also examined using environmental scanning electron microscopy, and the microscopic electrodeposition patterns were found to influence the optical response. The wavelength dependence of the optical response of deposited copper was determined and compared with calculations; optimal performance was at 400 nm for copper. A linear calibration curve was obtained over a range of 1 x 10(-7)-1 x 10(-4) M for copper and compared with that of cadmium. The simultaneous determination of cadmium and copper was demonstrated, and the mechanism of co-deposition is discussed.

Journal Article↗

Spectroelectrochemical sensing based on attenuated total internal reflectance stripping voltammetry. 2. Determination of mercury and lead.

Detection of lead and mercury by attenuated total internal reflectance spectroscopy coupled to stripping voltammetry is demonstrated. Changes in attenuation of light passing through an indium tin oxide optically transparent electrode (ITO-OTE) accompany the electrodeposition and stripping of lead and mercury on the electrode surface. The change in absorbance during stripping of electrodeposited metal constitutes the analytical response that enables detection over a range of 2.5 x 10(-7)-5 x 10(-5) and 5 x 10(-8)-5 x 10(-5) M for mercury and lead, respectively. The spectroelectrochemical responses of mercury and lead on the ITO surface are characterized and optimized with respect to solution conditions, the potential excitation signals used for deposition and stripping, and wavelength for detection. The deposited metals were examined by environmental scanning electron miscroscopy, and the electrodeposition pattern of lead and mercury was found to influence the optical response.

Electrochemistry↗

Further investigations on a poly(vinyl alcohol)- polyelectrolyte chemically selective optical film.

The ionomer poly(vinylbenzyltrimethylammonium chloride) has been blended with cross-linked poly(vinyl alcohol) to form optically clear composites that can be covalently linked as thin films to oxide surfaces. Films are characterized using spectroscopic ellipsometry with refractive index (n) and extinction coefficient (k) data presented for wavelengths 300 to 1100 nm. A refractive index of 1.54 and average thickness of 709 nm are typical of an air dry film prepared by spin-coating. Dynamic in situ ellipsometry results for films exposed to 0.1 M KNO(3) and 1.0 mM Fe(CN)(6)(-3) are presented. Upon initial exposure to 0.1 M KNO(3), an air dry film expands by about 160% and stabilizes in size and refractive index at about 18 hours. Ion exchange of film cationic groups with ferricyanide is marked by slight film contraction, presumably due to electrostatic cross-linking by the multivalent anion. These films are useful in the spectroelectrochemical sensor with our newly developed fluorescence detection mode, as demonstrated by results of the reversible incorporation of the fluorescent anion fluorescein.

Journal Article↗

Spectroelectrochemical sensing based on multimode selectivity simultaneously achievable in a single device. 16. Sensing by fluorescence.

A fluorescence spectroelectrochemical sensor capable of detecting very low concentrations of metal complexes is described. The sensor is based on a novel spectroelectrochemical sensor that incorporates multiple internal reflection spectroscopy at an optically transparent electrode (OTE) coated with a selective film to enhance detection limits by preconcentrating the analyte at the OTE surface. Nafion was used as the selective cation exchange film for detecting Ru(bpy)(3)(2+), the model analyte, which fluoresces at 605 nm when excited with a 441.6-nm HeCd laser. The unoptimized linear dynamic range of the sensor for Ru(bpy)(3)(2+) is between 1 x 10(-)(11) and 1 x 10(-)(7) M with a calculated 2 x 10(-)(13) M detection limit. The sensor employs extremely thin films ( approximately 12 nm) without significantly sacrificing its sensitivity. The sensor response is demonstrated with varying film thicknesses. A state-of-the-art flow cell design allows variable cell volumes as low as approximately 4 microL. Fluorescence of the sample can be controlled by electromodulation between 0.7 and 1.3 V. Sensor operation is not reversible for the chosen model film (Nafion) and sample (Ru(bpy)(3)(2+)) but it can be regenerated with ethanol for multiple uses.

Journal Article↗

Spectroelectrochemical sensing based on attenuated total internal reflectance stripping voltammetry. 1. Determination of lead and cadmium.

The electrodeposition and subsequent stripping of lead and cadmium on an indium tin oxide (ITO) optically transparent electrode (OTE) were monitored by attenuated total internal reflectance. Light passing through the ITO-OTE is attenuated proportionally to the concentration of metal ion and deposition time. The wavelength dependence of the optical responses of deposited Pb and Cd was determined; optimal performance based on maximum sensor absorbance was at 750 nm for Pb and at 400 nm for Cd. Calibration curves were obtained over a range of 5 x 10(-8) to 5 x 10(-5) M and 1 x 10(-9) to 1 x 10(-5) M for Pb and Cd, respectively, using change in absorbance that accompanied deposition and subsequent stripping of the electrodeposited metal from the ITO.

Journal Article↗

Spectroelectrochemical sensing based on multimode selectivity simultaneously achievable in a single device. 11. Design and evaluation of a small portable sensor for the determination of ferrocyanide in Hanford waste samples.

A portable spectroelectrochemical sensor has been designed, evaluated, and demonstrated on a complex sample of radioactive waste. The sensor consisted of a black delrin sample compartment with a total internal sample volume of 800 microL, attached to an indium tin oxide coated glass multiple internal reflection optical element. Detection was by total internal reflection of light from a blue light emitting diode source. After a 10 min uptake for each standard, the sensor showed a linear response in absorbance change for 5 x 10(-5) to 5 x 10(-3) M ferrocyanide with electrochemical modulation by scanning at 20 mV/s from -0.30 V to +0.55 V vs a Ag/AgCl reference electrode. Due to the complex nature of Hanford radioactive tank waste samples containing ferrocyanide, a standard addition method was developed for analysis. The spectroelectrochemical sensor determined a concentration of 9.2 mM ferrocyanide for U-Plant-2 simulant solution containing 9.38 mM ferrocyanide that was prepared according to Hanford process flowsheets. A radioactive tank waste sample from Hanford Tank 241-C-112 was determined to be 1.0 mM in ferrocyanide using the spectroelectrochemical sensor. A value for the ferrocyanide concentration in the sample of 0.61 mM was determined by FTIR spectroscopy.

Electrochemistry↗

Spectroelectrochemical sensing based on multimode selectivity simultaneously achievable in a single device. 13. Detection of aqueous iron by in situ complexation with 2,2'-bipyridine.

A spectroelectrochemical sensor with attenuated total reflectance at an indium-doped tin oxide (ITO) optically transparent electrode coated with a thin film of Nafion has been demonstrated for the determination of aqueous iron ion. The novelty of this sensor stems from its ability to take up colorless iron ion (Fe2+) from solution and complex it with an organic ligand, 2,2'-bipyridine (bipy), that has been previously loaded in the optically transparent charge-selective Nafion film coating the electrode. The resulting complex ion, tris(2,2'-bipyridyl)iron(II), Fe(bipy)3(2+), absorbs strongly, making it easily detectable via optical spectroscopy. Fe(bipy)3(2+) loaded into the selective film is oxidized to colorless Fe(bipy)3(3+), which gives rise to an absorbance change for quantifying iron. This paper maps the development of this sensor, from the spectroelectrochemical characterization of the complex ion at an ITO optically transparent electrode to an analysis of the uptake, retention, and optical response of the complex ion in the Nafion film. Finally, an evaluation of the uptake of aqueous Fe2+ by the bipy-loaded Nafion film is reported. These data include preliminary results illustrating the dependence of the sensor response on differing concentrations of Fe2+ in solution.

Journal Article↗