PubMed Health⌕ Search

Biomedical subjects

Channing R Robertson

Publications and source records attributed to Channing R Robertson.

3 recordsLinked to original sources

Simultaneous observation of enzyme surface diffusion and surface reaction using microfluidic patterning of substrate surfaces.

We present a study of the simultaneous observation of protease reaction and surface diffusion as the enzyme interacts with a model substrate surface. We use micro-fluidic patterning to decorate a bovine serum albumin substrate surface with stripes of adsorbed enzyme in the absence of physical barriers. Spreading of the enzyme from the initial striped region indicates surface diffusion, while removal of the substrate provides a measure of reactivity. Microfluidic patterning provides a means to determine the relative importance of enzyme adsorption, surface diffusion, and reaction on the rate of substrate removal.

Animals↗

The clearance of protein-bound solutes by hemofiltration and hemodiafiltration.

BACKGROUND: Hemofiltration in the form of continuous venovenous hemofiltration (CVVH) is increasingly used to treat acute renal failure. Compared to hemodialysis, hemofiltration provides high clearances for large solutes but its effect on protein-bound solutes has been largely ignored. METHODS: Standard clinical systems were used to remove test solutes from a reservoir containing artificial plasma. Clearances of the protein-bound solutes phenol red (C(PR)) and indican (C(IN)) were compared to clearances of urea (C(UREA)) during hemofiltration and hemodiafiltration. A mathematical model was developed to predict clearances from values for plasma flow Q(p), dialysate flow Q(d), ultrafiltration rate Q(f), filter size and the extent of solute binding to albumin. RESULTS: When hemofiltration was performed with Q(p) 150 mL/min and Q(f) 17 mL/min, clearance values were C(PR) 1.0 +/- 0.1 mL/min; C(IN) 3.7 +/- 0.5 mL/min; and C(UREA) 14 +/- 1 mL/min. The clearance of the protein-bound solutes was approximately equal to the solute-free fraction multiplied by the ultrafiltration rate corrected for the effect of predilution. Addition of Q(d) 42 mL/min to provide HDF while Q(p) remained 150 mL/min resulted in proportional increases in the clearance of protein-bound solutes and urea. In contrast, the clearance of protein-bound solutes relative to urea increased when hemodiafiltration was performed using a larger filter and increasing Q(d) to 300 mL/min while Q(p) was lowered to 50 mL/min. The pattern of observed results was accurately predicted by mathematical modeling. CONCLUSION: In vitro measurements and mathematical modeling indicate that CVVH provides very limited clearance of protein-bound solutes. Continuous venous hemodiafiltration (CVVHDF) increases the clearance of protein-bound solutes relative to urea only when dialysate flow rate and filter size are increased above values now commonly employed.

Acute Kidney Injury↗

Increasing dialysate flow and dialyzer mass transfer area coefficient to increase the clearance of protein-bound solutes.

Clinical hemodialysis systems achieve high single pass extraction of small solutes that are not bound to plasma proteins. But they clear protein-bound solutes much less effectively. This study examines the extent to which clearance of a protein-bound test solute is improved by increasing the dialyzer mass transfer area coefficient (KoA) and the dialysate flow rate (Qd). A reservoir containing test solutes and artificial plasma with albumin concentration approximately 4 g/dl was dialyzed with a standard clinical dialysate delivery system. The clearance of phenol red (ClPR) was compared with the clearances of urea and creatinine at a plasma flow rate (Qp) of 200 ml/min with varying values of KoA and Qd. ClPR increased from 11 +/- 2 ml/min to 23 +/- 2 ml/min when KoA for phenol red, KoAPR, was increased from 238 to 640 ml/min and Qd was increased from 286 +/- 6 ml/min to 734 +/- 9 ml/min. Increasing either KoAPR or Qd alone had lesser effects. Clearance values for phenol red were much lower than clearance values for the unbound solutes urea and creatinine, which ranged from 150 to 200 ml/min and were less affected by varying KoA and Qd. A mathematical model was developed to predict ClPR from values of Qp, Qd, the fraction of phenol red bound to albumin (94% +/- 1%) and KoAPR. The model accurately predicts the pattern of measured results and shows further that ClPR can be made to approach Qp only by very large increases in both KoAPR and Qd.

Albumins↗