Identification of carboxyl-terminal peptide fragments of parathyroid hormone in human plasma at low-picomolar levels by mass spectrometry.

For decades, researchers have tried to identify the primary structures of circulating carboxyl-terminal parathyroid hormone (C-PTH) peptide fragments that may be present at only picomolar levels in human plasma. Although immunoassays and radiosequencing techniques have provided valuable fragment characterizations, no analysis has successfully determined their exact primary structures. In this work, for the first time, four human C-PTH peptide fragments, hPTH(34-84), hPTH(37-84), hPTH(38-84), and hPTH(45-84), have been identified from human plasma using MS-based methods. C-PTH peptide fragments were isolated from plasma samples by immunoaffinity extraction. The eluate was analyzed by capillary LC fractionation followed by MALDI-TOF-MS or by on-line coupling of nano-LC with ESI-TOF-MS. Both the MALDI- and the ESI-based approaches were capable of detecting C-PTH peptide fragments in human plasma at <10 pmol/L. The MALDI-TOF approach was effective in preliminary searches for C-PTH peptide fragments, but the use of high laser power limited the resolution necessary for accurate C-PTH peptide identification. The high mass resolution (10,000) and accuracy (10 ppm) attained by the ESI-TOF approach enabled unambiguous identification of these peptides. The four C-PTH peptide fragments identified in plasma samples from patients with chronic renal insufficiency were also found in the plasma of healthy women receiving recombinant human PTH either by subcutaneous injection or by intravenous infusion. This newly developed analytical capability should greatly enhance the understanding of PTH metabolism and parathyroid gland function.

Humans↗

High-speed free-flow electrophoresis on chip.

A microfluidic device has been developed for continuous separation in free-flow electrophoresis (FFE) mode. A mixture of two fluorescent reagents is separated into two component streams in 75 ms using a sample flow rate of 2 nL/s. The residence time of sample in the whole separation compartment is 2 s. The separation bed volume is 0.2 microL. The chip has also been used for free-flow electrophoresis of fluorescein-5-isothiocyanate-labeled amino acids in both aqueous and binary media. The short residence time and small sample flow rate make the FFE chip feasible for on-line monitoring on production lines and other chemical or biochemical processes. The in-house-made chip was composed of a plain glass substrate of 1.5-mm thickness and a PDMS layer of 0.3-mm thickness with micromachined channels. The channel design presented in this paper is versatile. With the same kind of PDMS substrates, chips for various purposes can be made depending on the locations of the reservoirs, which are cut out on the PDMS substrate. The results presented verify the scaling laws and allow prediction of FFE performances comparable to what is now state of the art on capillary electrophoresis chips.

Journal Article↗

Sub-second isoelectric focusing in free flow using a microfluidic device.

Using a microfabricated chip with a bed volume of 0.2 microL we demonstrate the validity of the scaling laws for molecular mass transport of isoelectric focusing (IEF) in free flow. Nano- or microlitre sample volumes can be concentrated within 430 ms by a factor of up to 400. These very fast performances make the chip applicable to proteomic analysis and for continuous monitoring of biochemical processes.

Angiotensin I↗

In-column field-amplified sample stacking of biogenic amines on microfabricated electrophoresis devices.

A novel method for performing in-column field-amplified sample stacking (FASS) in chip-based electrophoretic systems is presented. The methodology involves the use of a narrow sample channel (NSC) injector. NSC injectors allow sample plugs to be introduced directly into the separation channel, and subsequent stacking and separation can proceed without any need for leakage control. More importantly, stacking and separation occur in a single step negating the requirement for complex channel geometries and voltage switching to control sample plugs during the stacking procedure. The chip is composed of six paralleled systems. Using the NSC injector design, the number of reservoirs in the multiplexed chip is reduced to N + 2, where N is the number of paralleled systems. This design feature radically reduces the complexity in chip structures and associated chip operation. The approach is applied to the analysis of fluorescently labelled biogenic amines affording detection at concentrations down to 20 pM.

Biogenic Monoamines↗