Radiation injuries after fluoroscopic procedures.

Fluoroscopically guided diagnostic and interventional procedures have become much more commonplace over the last decade. Current fluoroscopes are easily capable of producing dose rates in the range of 0.2 Gy (20 rads) per minute. The dose rate often changes dramatically with patient positioning and size. Most machines currently in use have no method to display approximate patient dose other than the rough surrogate of total fluoroscopy time. This does not include patient dose incurred during fluorography (serial imaging or cine runs), which can be considerably greater than dose during fluoroscopy. There have been over 100 cases of documented radiation skin and underlying tissue injury, a large portion of which resulted in dermal necrosis. The true number of injuries is undoubtedly much higher. The highest dose procedures are complex interventions such as those involving percutaneous angioplasties, stent placements, embolizations, and TIPS. In some cases skin doses have been in excess of 60 Gy (6000 rads). In many instances the procedures have been performed by physicians with little training in radiation effects, little appreciation of the radiation injuries that are possible or the strategies that could have been used to reduce both patient and staff doses. Almost all of the severe injuries that have occurred were avoidable.

Eye↗

Using a sterile disposable protective surgical drape for reduction of radiation exposure to interventionalists.

OBJECTIVE: The purpose of this paper is to show the effectiveness of a new radiation protection method designed to decrease the amount of scatter radiation received by practitioners performing procedures under fluoroscopic guidance. MATERIALS AND METHODS: A sterile, disposable, lead-free surgical drape containing radiation protection material composed primarily of bismuth was evaluated for effectiveness in reducing radiation doses to health care personnel. Measurements of phantom scatter, patient scatter, skin entrance, and the effects of collimation, together with comparative monthly thermoluminescent dosimeter recordings, were taken to determine the effectiveness of X-ray beam attenuation using the bismuth drapes. RESULTS: Scatter radiation to physicians, as measured by thermoluminescent dosimeters placed on each eye, the thyroid, and the wrist, was reduced by 12-fold for the eyes, 25-fold for the thyroid, and 29-fold for the hands when the radiation-attenuating surgical drape was used when compared with control studies performed with a standard nonattenuating surgical drape alone. Monthly thermoluminescent dosimeter measurements decreased fourfold in one physician. Using the protective drape reduced exposure to the assistant in each case to negligible levels. Skin entrance dose was not increased unless the protective drape was placed directly in the X-ray beam. An X-ray attenuation factor equivalent to 0.1 mm of lead with 8 x 8 cm collimation reduced the scatter rates from five- to ninefold despite a 30-40% increase in entrance exposure rate as the lead equivalence increased. CONCLUSION: Depending on the procedure, the height of the practitioner, and the positioning of the radiation-attenuating surgical drape, use of this drape can substantially reduce the radiation dose to personnel with minimal or no additional radiation exposure to the patient.

Bismuth↗