Radiation injuries after fluoroscopic procedures.

Abstract

Fluoroscopically guided diagnostic and interventional procedures have become much more commonplace over the last decade. Current fluoroscopes are easily capable of producing dose rates in the range of 0.2 Gy (20 rads) per minute. The dose rate often changes dramatically with patient positioning and size. Most machines currently in use have no method to display approximate patient dose other than the rough surrogate of total fluoroscopy time. This does not include patient dose incurred during fluorography (serial imaging or cine runs), which can be considerably greater than dose during fluoroscopy. There have been over 100 cases of documented radiation skin and underlying tissue injury, a large portion of which resulted in dermal necrosis. The true number of injuries is undoubtedly much higher. The highest dose procedures are complex interventions such as those involving percutaneous angioplasties, stent placements, embolizations, and TIPS. In some cases skin doses have been in excess of 60 Gy (6000 rads). In many instances the procedures have been performed by physicians with little training in radiation effects, little appreciation of the radiation injuries that are possible or the strategies that could have been used to reduce both patient and staff doses. Almost all of the severe injuries that have occurred were avoidable.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fred A Mettler, Titus R Koenig, Louis K Wagner, Charles A Kelsey. 2002. Radiation injuries after fluoroscopic procedures.. https://doi.org/10.1016/s0887-2171(02)90014-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Objective measurement of postocclusion surge during phacoemulsification in human eye-bank eyes.

PURPOSE: To objectively compare the postocclusion vacuum surge among different phacoemulsification machines and devices. DESIGN: Experimental study. METHODS: Infiniti, Legacy, Millennium, and Sovereign were tested in an eye-bank eye. All the machines were tested with 20-gauge non-ABS tips, 430 mm Hg vacuum pressure, 24 ml/minute aspiration rate, peristaltic pump, and 75 cm bottle height. In addition, Infiniti and Legacy were also tested with 20-gauge bypass tips (ABS), 125 cm bottle height, and 40 ml/minute flow rate. We also tested 19-gauge tips with Infiniti and Sovereign and the venturi pump for Millennium. RESULTS: Significant differences were found between all the machines tested with Millennium peristaltic generating the least and Millennium Venturi the most surge. ABS tips significantly decreased the surge for Legacy but not for Infiniti. Cruise Control (CC) had a significant effect on Sovereign but not on Millennium. Increasing the bottle height decreased surge while increasing the flow increased surge for both Infiniti and Legacy. The 19-gauge tips increased surge for both Infiniti and Sovereign. CONCLUSIONS: Surge varied over a range of 40 microm to more than 2 mm. ABS and CC decrease surge, especially when the machine is not functioning near the limits of surge prevention. Certain parameters, such as a 19-gauge tip and high flow, dramatically increased surge, whereas elevating the bottle ameliorates it. Understanding the impact of all these features will help in minimizing the problem.

Eye↗

Serotonin receptor subtype mRNA expression in human ocular tissues, determined by RT-PCR.

PURPOSE: To determine the relative density and tissue localization of mRNAs for serotonin (5-hydroxytryptamine; 5HT) receptor subtypes in human ocular tissues and correlate with their possible functions in the eye. METHODS: Total RNA was extracted from human ocular tissues samples from multiple donors and transcribed into cDNA. An optimized reverse transcriptase polymerase chain reaction (RT-PCR) procedure was then used to amplify the signals using primers designed against human 5HT receptor cDNAs. The PCR products were analyzed by gel electrophoresis and confirmed by endonuclease digestion. RESULTS: Variable amounts of total RNA were extracted from different tissues with the least amount from ciliary epithelium and most amount from retina. 5HT2 receptor subtype mRNAs were the most abundant with 5HT2A and 5HT2B being the most predominant in the retina, ciliary body, ciliary epithelium, choroid, conjunctiva, and iris. Ciliary body, choroid, and conjunctiva were most enriched in 5HT3 receptor mRNA, with relatively lower levels in the iris. 5HT4 receptor mRNA was most enriched in the retina, ciliary body, choroid, conjunctiva, and somewhat detectable in the iris. 5HT5 receptor mRNA was abundant in the retina, ciliary body, and iris. 5HT6 receptor mRNA was the least abundant of all subtypes studied and could only be detected in the iris. 5HT7 receptor mRNA was enriched in the ciliary body, choroid, conjunctiva, and iris, with much lower levels in the retina and ciliary epithelium. Optic nerve tissue of 1-2 donors exhibited the presence of 5HT2B, 5HT5, and 5HT7 receptor mRNAs. Data for human trabecular meshwork cells indicated a high density of mRNAs for 5HT2A and 5HT2B, with much lower levels of 5HT2C, 5HT5, and 5HT7 receptor mRNAs. CONCLUSIONS: Human ocular tissues differentially expressed mRNAs for the various 5HT receptor subtypes. These studies suggest a diverse range of possible physiological and pharmacological functions of 5HT receptors in these human ocular tissues.

Eye↗