PubMed Health⌕ Search

Biomedical subjects

Charles Q Le

Publications and source records attributed to Charles Q Le.

6 recordsLinked to original sources

Adhesion of composite to enamel and dentin surfaces irradiated by IR laser pulses of 0.5-35 micros duration.

The characteristics of laser-treated tooth surfaces depend on the laser wavelength, pulse duration, spatial and temporal laser beam quality, incident fluence, surface roughness, and the presence of water during irradiation. Ablated surfaces are most commonly restored with adhesive dental materials and the characteristics of the ablated surfaces influence adhesion of restorative materials. Previous studies suggest that high bond strengths can be achieved using shorter laser pulses that minimize peripheral thermal damage. In this study, Er:YSGG, Er:YAG, and CO(2) lasers were used at irradiation intensities sufficient to simulate efficient clinical caries removal to uniformly irradiate bovine enamel and human dentin surfaces using a motion control system with a microprocessor-controlled water spray. The degree of spatial overlap of adjacent pulses was varied so as to investigate the influence of irradiation uniformity and surface roughness on the bond strength. Composite resin was bonded to the irradiated surfaces and shear bond tests were used to obtain bond strengths in MPa. The highest results were obtained using the Er:YAG pulses with pulse durations less than 35 mus without the necessity for postirradiation acid etching. Some of these groups were not significantly different from nonirradiated, acid-etch-only positive control groups.

Acrylic Resins↗

Dissolution studies of bovine dental enamel surfaces modified by high-speed scanning ablation with a lambda = 9.3-microm TEA CO(2) laser.

BACKGROUND AND OBJECTIVES: Previous studies have demonstrated that lasers can be used to modify the chemical composition of dental enamel to render the mineral phase more resistant to acid dissolution with minimal peripheral thermal damage. Transverse excited atmospheric (TEA) CO(2) lasers tuned to the strong mineral absorption of hydroxyapatite (HAP) near lambda = 9 microm are well-suited for the efficient ablation of dental hard tissues if the laser-pulse is stretched to greater than 5-10 microseconds to avoid plasma shielding phenomena. Moreover, TEA CO(2) lasers can be operated at very high repetition rates and are inherently less expensive and more versatile than Er:YAG and Er:YSGG solid-state lasers. In this study a lambda = 9.3-microm TEA CO(2) with a pulse duration of 8 microseconds and a repetition rate of 300 Hz was used to uniformly treat bovine enamel surfaces at ablative irradiation intensities. We hypothesized that a uniform surface layer of modified enamel of improved crystallinity and CaP phase composition would be formed with an enhanced resistance to acid-dissolution in the ablated areas at higher scanning rates used with the water spray. Such a modified layer of enamel formed at the base and walls of a cavity preparation under the irradiation conditions employed in this study have the potential to inhibit secondary caries under sealants and restorations. STUDY DESIGN/MATERIALS AND METHODS: The surfaces of bovine enamel blocks (3 x 3 mm(2)) were rapidly scanned across the laser beam at rates of 2, 3, and 6 mm/second with and without a water-spray at an incident fluence of 30 J/cm(2). The resistance to acid dissolution was evaluated using controlled surface dissolution experiments on laser-irradiated and control samples. RESULTS: The groups irradiated at a fluence of 30 J/cm(2) with a repetition rate of 300 Hz and a high scan rate of 6 mm/second with and without water-cooling significantly reduced the overall surface dissolution rates (P < 0.001). At low scan rates (2-3 mm/second) excessive heat deposition resulted in the formation of an outer layer of asperities containing non-apatitic CaP phases that were more susceptible to acid-dissolution. At a scanning rate of 6 mm/second even without the water spray a layer of purer phase HAP was formed without thermal damage, indicating that a high scanning rate can be used to avoid excessive thermal damage during ablation. The best results (80% inhibition) were attained for the higher scanning speed 6-mm/second combined with a water spray. CONCLUSION: This study demonstrates that an enamel surface with enhanced resistance to acid dissolution is produced after ablation with lambda = 9.3-microm TEA CO(2) laser pulses delivered at high-repetition rates if sufficiently high scanning rates are used with or without a water-spray.

Animals↗

Peripheral thermal and mechanical damage to dentin with microsecond and sub-microsecond 9.6 microm, 2.79 microm, and 0.355 microm laser pulses.

BACKGROUND AND OBJECTIVES: It is desirable to minimize peripheral thermal damage during laser irradiation, since thermal damage to collagen and mineral compromises the bond strength to restorative materials in dentin and inhibits healing and osteointegration in bone. There were two primary objectives of this study. The first objective was to measure the degree of thermal damage peripheral to incisions in dentin produced with lasers resonant to the specific absorption bands of water, collagen, and hydroxyapatite with varying pulse duration using polarized-light microscopy (PLM). The second objective was to use synchrotron radiation infrared spectromicroscopy (SR-FTIR) to identify the specific chemical nature of the optical changes observed under PLM in the respective zones of thermal damage peripheral to the laser incisions. STUDY DESIGN/MATERIALS AND METHODS: Precise incisions were produced in 3 x 3 mm2 blocks of human dentin using CO2 (9.6 microm), Er:YSGG (2.79 microm), and Nd:YAG (355 nm) lasers with and without a computer controlled water-spray. Optical coherence tomography (OCT) was used to obtain optical cross-sections of each incision to determine the rate of ablation. The peripheral thermal damage zone around each incision was analyzed using PLM and SR-FTIR. RESULTS: Thermally induced chemical changes to both mineral and the collagen matrix were observed with SR-FTIR with a 10 microm spatial resolution and those changes were correlated with optical changes observed with PLM. Minimal (<10 microm) thermal damage was observed for pulse durations less than the thermal relaxation time (Tr) of the deposited laser energy, with and without applied water at 9.6 microm and with only applied water at 2.79 microm. For pulse durations greater than Tr, greater peripheral thermal damage was observed for both IR laser wavelengths with and without the water-spray. There was minimal thermal damage for 355 nm laser pulses less than Tr with and without applied water; however, extensive mechanical damage (cracks) was observed. CONCLUSIONS: High resolution SR-FTIR is well suited for characterization of the chemical changes that occur due to thermal damage peripheral to laser incisions in proteinaceous hard tissues. Sub-microsecond pulsed IR lasers resonant with water and mineral absorption bands ablate dentin efficiently with minimal thermal damage. Similar laser parameters are expected to apply to the ablation of alveolar bone.

Collagen↗

Irradiation of dental enamel with Q-switched lambda = 355-nm laser pulses: surface morphology, fluoride adsorption, and adhesion to composite resin.

BACKGROUND AND OBJECTIVES: Lasers can be used to modify the chemical composition of dental enamel to increase the bond strength to restorative materials and to render the mineral phase more resistant to acid dissolution. Previous studies have suggested a synergistic relationship between CO(2) laser irradiation and fluoride treatment on increased resistance to acid dissolution. In this study a near-UV laser operating with lambda = 355-nm laser pulses of 3-5 nanoseconds duration was used to modify the surface morphology of dental enamel to increase the bond strength to restorative materials and increase the uptake of topical fluoride to render the surface more resistant to acid dissolution. We hypothesize that the short UV laser pulses are primarily absorbed by protein and lipid localized between the enamel prisms resulting in removal of intact mineral effectively etching the surface without thermal modification of the mineral phase. Such modification is likely to increase the permeability of the enamel surface and the subsequent absorption of fluoride. In addition, there is an increase in surface roughness without the formation of a layer of loosely adherent, thermally modified enamel that increases the bond strength to composite restorative materials. STUDY DESIGN/MATERIALS AND METHODS: The surfaces of blocks of bovine enamel, 5 x 5 mm(2), were uniformly irradiated by 355-nm laser pulses and subsequently bonded to composite. The shear bond test was used to assess the bond strength of non-irradiated blocks (negative control), acid etched blocks (positive control), and laser irradiated blocks. The resistance to acid dissolution was evaluated using controlled surface dissolution experiments on irradiated samples, irradiated samples exposed to topical fluoride, and non-irradiated control samples with and without fluoride. RESULTS: The laser surface treatments significantly increased the shear-bond strength of enamel to composite, to a level exceeding 20 MPa which was significantly more than the non-irradiated control samples and significantly less than the acid etch. Laser irradiation alone and topical fluoride application alone did not significantly increase the resistance to acid dissolution. The laser treatment followed by topical application of fluoride significantly increased the resistance to acid dissolution to a level of over 50% versus the control samples. CONCLUSIONS: We present a novel method for increasing bond strength to restorative materials and enhancing fluoride delivery to enamel surfaces and shed some light on the underlying mechanisms of caries inhibition via laser treatment and topical application of fluoride.

Animals↗

Influence of an optically thick water layer on the bond-strength of composite resin to dental enamel after IR laser ablation.

BACKGROUND AND OBJECTIVES: Several studies of hard tissue ablation with Er:YAG lasers have shown that the addition of an optically thick water layer ( approximately 1 mm) added to the surface of dental enamel before each incident laser pulse, profoundly influences the rate and efficiency of ablation and the resulting surface morphology. The objective of this study was the determination of laser parameters which result in clinically useful bond strengths without the need for phosphoric acid etching. The hypothesis to be tested was that laser irradiation through a relatively thick layer of water would result in a surface to which composite could be bonded with bond strength similar to surfaces etched with phosphoric acid. This hypothesis is predicated on the assumption that the water prevents the formation of non-apatite calcium phosphate phases on the enamel surface. MATERIALS AND METHODS: In this study, a calibrated syringe pump and a motion control system were used to uniformly treat flat enamel surfaces using free-running Er:YAG laser pulses with and without water, and 9.6 mum CO(2) laser pulses on a dry surface for comparison. The rate of water delivery that resulted in the most efficient ablation was determined by profiling the resulting laser incisions using optical coherence tomography. In addition, enamel surfaces of 5 x 5 mm(2) were uniformly treated and the resulting surface morphology was examined using synchrotron radiation-fourier transform infrared spectroscopy (SR-FTIR), and optical and electron microscopy. The influence of the modified surface morphology on the adhesion of composite resin was investigated. RESULTS: The shear-bond strength of composite bonded to enamel surfaces irradiated at intensities clinically relevant for caries removal approached values measured for conventional acid etching when the water delivery rate was optimized. CONCLUSIONS: This study demonstrates that composite restorative materials can be directly bonded to laser prepared surfaces without the necessity of further surface preparation and acid etching and that the addition of a thick water layer ( approximately 1 mm) prevents the formation of undesirable CaP phases that compromise adhesion to restorative materials. 2003.

Animals↗

Thermal and chemical modification of dentin by 9-11-microm CO2 laser pulses of 5-100-micros duration.

BACKGROUND AND OBJECTIVES: Previous studies have shown that dentin can be thermally modified by pulsed CO(2) laser irradiation to form a more highly mineralized tissue. The implications are important for the potential laser modification or removal of dentinal and root caries and the transformation of dentin to a more acid resistant mineralized tissue. STUDY DESIGN/MATERIALS AND METHODS: Time resolved radiometry measurements with TEA CO(2) laser pulses were used to determine the magnitude of the absorption coefficients of dentin at the highly absorbed CO(2) laser wavelengths and to measure the temperature excursions during lambda = 9.3, 9.6, 10.3, and 10.6 microm laser irradiation at irradiation intensities of 0.1-8 J/cm(2) per pulse. In addition, photoacoustic and transient reflectance measurements were used to monitor the loss of water and organics and to detect the thresholds for surface modification and tissue ablation. RESULTS: The absorption coefficients were measured to be 5,000; 6,500; 1,200; and 800 cm(-1) at lambda = 9.3, 9.6, 10.3, and 10.6 microm, respectively. The surface temperatures of dentin were markedly higher than those measured on enamel for similar irradiation intensities due to the lower reflectance losses of dentin and the lower thermal diffusivity of dentin at the respective wavelengths. Hence, lower fluences are required for the thermal decomposition of dentin. Ablation typically occurred with the first few laser-pulses during multiple pulse irradiation and eventually ceased after modification of dentin to a more highly mineralized enamel-like tissue. The debris ejected during the initial laser pulses shielded the surface by as much as 60% at the low fluences employed in this study. Optical and electron microscopy and IR spectroscopy indicated that incident laser pulses with incident fluence as low as 0.5 J/cm(2) at 9.3 and 9.6 microm wavelengths with a duration of 5-8-micros were sufficient to induce chemical and morphological changes in dentin. CONCLUSIONS: In this study, the laser parameters for the efficient thermal modification of dentin with minimum heat deposition at CO(2) laser wavelengths were firmly established.

Dental Caries↗