PubMed Health⌕ Search

PubMed · 15389737

Peripheral thermal and mechanical damage to dentin with microsecond and sub-microsecond 9.6 microm, 2.79 microm, and 0.355 microm laser pulses.

Abstract

BACKGROUND AND OBJECTIVES: It is desirable to minimize peripheral thermal damage during laser irradiation, since thermal damage to collagen and mineral compromises the bond strength to restorative materials in dentin and inhibits healing and osteointegration in bone. There were two primary objectives of this study. The first objective was to measure the degree of thermal damage peripheral to incisions in dentin produced with lasers resonant to the specific absorption bands of water, collagen, and hydroxyapatite with varying pulse duration using polarized-light microscopy (PLM). The second objective was to use synchrotron radiation infrared spectromicroscopy (SR-FTIR) to identify the specific chemical nature of the optical changes observed under PLM in the respective zones of thermal damage peripheral to the laser incisions. STUDY DESIGN/MATERIALS AND METHODS: Precise incisions were produced in 3 x 3 mm2 blocks of human dentin using CO2 (9.6 microm), Er:YSGG (2.79 microm), and Nd:YAG (355 nm) lasers with and without a computer controlled water-spray. Optical coherence tomography (OCT) was used to obtain optical cross-sections of each incision to determine the rate of ablation. The peripheral thermal damage zone around each incision was analyzed using PLM and SR-FTIR. RESULTS: Thermally induced chemical changes to both mineral and the collagen matrix were observed with SR-FTIR with a 10 microm spatial resolution and those changes were correlated with optical changes observed with PLM. Minimal (<10 microm) thermal damage was observed for pulse durations less than the thermal relaxation time (Tr) of the deposited laser energy, with and without applied water at 9.6 microm and with only applied water at 2.79 microm. For pulse durations greater than Tr, greater peripheral thermal damage was observed for both IR laser wavelengths with and without the water-spray. There was minimal thermal damage for 355 nm laser pulses less than Tr with and without applied water; however, extensive mechanical damage (cracks) was observed. CONCLUSIONS: High resolution SR-FTIR is well suited for characterization of the chemical changes that occur due to thermal damage peripheral to laser incisions in proteinaceous hard tissues. Sub-microsecond pulsed IR lasers resonant with water and mineral absorption bands ablate dentin efficiently with minimal thermal damage. Similar laser parameters are expected to apply to the ablation of alveolar bone.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alfredo Dela Rosa, Anupama V Sarma, Charles Q Le, Robert S Jones, Daniel Fried. 2004. Peripheral thermal and mechanical damage to dentin with microsecond and sub-microsecond 9.6 microm, 2.79 microm, and 0.355 microm laser pulses.. https://doi.org/10.1002/lsm.20090

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tissue factor and thrombomodulin expression on endothelial cell-seeded collagen modules for tissue engineering.

The creation of functional tissue engineering constructs to repair or replace diseased tissues requires a well-formed vasculature network within the construct and the endothelial cells lining that vascular bed must display a nonthrombogenic phenotype. A new approach to tissue engineering involves the assembly of smaller components (modules fabricated at the hundred micron scale) into larger constructs. The modules, collagen gel containing the particular tissue cell of interest, are covered with endothelial cells prior to assembly so that the interconnected channels that are formed are lined with endothelial cells, creating a mimic of a vascular network. Here, we confirmed (using confocal microscopy primarily) that the human umbilical vein endothelial cells, seeded on collagen gel modules without a second embedded cell and without flow, bore the molecular markers of low thrombogenicity. Two days, after seeding on the modules, endothelial cells displayed the typical cobblestone morphology, formed tight cell-cell junctions and covered the whole module surface. Immunofluorescence staining showed that at both 2 days and 7 days after seeding, only a few cells expressed tissue factor while this number was dramatically increased after TNFalpha stimulation. On the other hand, thrombomodulin was expressed by the majority of seeded cells and expression was reduced after TNFalpha stimulation.

Collagen↗

Application of crosslinkers to dentin collagen enhances the ultimate tensile strength.

The stabilization of dentin collagen with biocompatible crosslinking agents may be of clinical importance to improve dentin bond strength. The present study aimed to evaluate the effect of three collagen crosslinking agents on the ultimate tensile strength (UTS) of undemineralized and demineralized dentin. Ten freshly extracted sound molars were sectioned into 0.5 x 0.5 mm2 thick beams. The beams were either demineralized or kept undemineralized. Then, specimens were subdivided into four groups according to treatments--PBS solution (control), 5% glutaraldehyde (GD), 0.5% proanthocyanidin PBS solution (PA), and 0.625% genipin PBS solution (GE). Specimens were kept in their respective solutions for either 4 or 40 h. To assess UTS, specimens were subjected to tensile forces at a crosshead speed of 1 mm/min. Statistical analysis was performed using two-way ANOVA and Fisher's PLSD test (p < 0.05). Statistically significant increases in UTS were observed for demineralized dentin after PA and GE dentin treatment, when compared with those of the control group. Dentin treated with GD showed no statistically significant differences in UTS when compared with that the control. Undemineralized dentin revealed no significant differences as compared to that of the control, regardless of the collagen crosslinkers. The application of two naturally occurring crosslinkers, i.e., PA and GE, to dentin collagen significantly improves UTS, indicating its potential value in restorative dentistry.

Collagen↗

Using gold nanorods to probe cell-induced collagen deformation.

In biological tissue, complex mechanisms of cellular response are closely linked to the mechanical environment that cells experience. The key to understanding these mechanisms may lie in measurement of local mechanical fields near living cells and between cells. We have developed a novel optical measurement technique which combines the light elastically scattered from gold nanorods with digital image analysis to track local deformations that occur in vitro between cells, in real time, under darkfield optical microscopy. We find that measurable tension and compression exist in the intercellular matrix at the length scale of micrometers, as the cells assess, adapt, and rearrange their environment.

Collagen↗