Increase of accuracy in intraoperative navigation through high-resolution flat-panel volume computed tomography: experimental comparison with multislice computed tomography-based navigation.

HYPOTHESIS: High-resolution imaging, as provided by flat-panel-based volume computed tomography (fpVCT), could increase navigation accuracy and could therefore improve image-guided procedures or make novel navigated surgery concepts possible. BACKGROUND: Intraoperative navigation is an accepted tool in head and neck surgery. However, its use is limited in the lateral cranial base because of its low surgical accuracy. Surgical accuracy is substantially influenced by the resolution of the underlying data set. The fpVCT offers a resolution of nearly two times higher than multislice computed tomography (MSCT). Target registration error (TRE), as a measurement for surgical navigation accuracy, should decrease when navigation is based on fpVCT data sets. METHODS: An acrylic glass phantom with 37 fiducial points was scanned in a current MSCT and in an experimental fpVCT. Both data sets were imported in an optical navigation system. Five fiducial points were used for registration, and seven points were used for measuring TRE. The distance between the indicated pointer tip and the corresponding fiducial point in data set was measured as TRE. Registration and TRE measurement were repeated five times for each computed tomographic data set. Average TREs were calculated, and results were compared using t-test. RESULTS: The average TRE using MSCT (0.82 mm [standard deviation, 0.35 mm]) was significantly higher than that using fpVCT (0.46 mm [standard deviation, 0.22 mm]) (p < 0.01). CONCLUSION: Submillimeter surgical navigation accuracy is possible using high-resolution fpVCT. This could be highly beneficial in cranial base surgery navigation.

Humans↗

Dissociation of angiogenesis and tumorigenesis in follistatin- and activin-expressing tumors.

The transforming growth factor-beta superfamily member activin and its antagonist, follistatin, act as a pleiotropic growth factor system that controls cell proliferation, differentiation, and apoptosis. Activin inhibits fibroblast growth factor 2-induced sprouting angiogenesis in vitro (spheroidal angiogenesis assay) and in vivo (Matrigel assay). To further study the role of the activin/follistatin system during angiogenesis and tumor progression, activin- and follistatin-expressing R30C mammary carcinoma cells were studied in mouse tumor experiments. Surprisingly, activin-expressing tumors grew much faster than follistatin-expressing tumors although they failed to induce increased angiogenesis (as evidenced by low microvessel density counts). Conversely, follistatin-expressing tumors were much smaller but had a dense network of small-diameter capillaries. Qualitative angioarchitectural analyses (mural cell recruitment, perfusion) revealed no major functional differences of the tumor neovasculature. Analysis of activin- and follistatin-expressing R30C cells identified a cell autonomous role of this system in controlling tumor cell growth. Whereas proliferation of R30C cells was not altered, follistatin-expressing R30C cells had an enhanced susceptibility to undergo apoptosis. These findings in experimental tumors are complemented by an intriguing case report of a human renal cell carcinoma that similarly shows a dissociation of angiogenesis and tumorigenesis during tumor progression. Collectively, the data shed further light into the dichotomous stimulating and inhibiting roles that the activin/follistatin system can exert during angiogenesis and tumor progression. Furthermore, the experiments provide a critical proof-of-principle example for the dissociation of angiogenesis and tumorigenesis, supporting the concept that tumor growth may not be dependent on increased angiogenesis as long as a minimal intratumoral microvessel density is maintained.

Activins↗

Volumetry of human molars with flat panel-based volume CT in vitro.

The flat panel-based volume computed tomography (fpVCT) is a new CT device applicable for experimental, three-dimensional evaluation of teeth at a resolution of about 150 microm in the high contrast region. The aim of this study was to investigate whether fpVCT was suitable for quantification of the volumes of dental hard tissues and the root canal system to establish a new method for morphological studies. Fifty-two extracted third molars (maxillary: 31, mandibular: 21) were examined with a prototype of an fpVCT using a volumetry algorithm at different levels according to the radiographic density of enamel and dentine. Volumetry of the root canal system was performed after "region growing segmentation": starting from a voxel in the centre of the root canal, this algorithm searches voxels of same density in the surrounding. The volumetry of the root canal system was stopped by the investigator at the apical constriction. Results showed that dentine, enamel and root canal system could be well distinguished in three-dimensional images. Volumetry yielded the following data (cm(3), mean+/-SD): dentine 0.438+/-0.111, enamel 0.227+/-0.051, root canal system 0.052+/-0.017 and total volume 0.753+/-0.159. In conclusion, the fpVCT is appropriate for non-destructive volumetry of large numbers of teeth in experimental laboratory studies.

Absorptiometry, Photon↗

Flat-panel volume computed tomography for cochlear implant electrode array examination in isolated temporal bone specimens.

HYPOTHESIS: Flat-panel based volume computed tomography could improve cochlear implant electrode evaluation in comparison with multislice computed tomography. BACKGROUND: Flat-panel based volume computed tomography offers higher spatial resolution and less metal artifacts than multislice computed tomography. Both characteristics could improve the evaluation of challenging but important questions in cochlear implantation assessment, such as an exact imaging of cochlea, osseous spiral lamina, electrode array position, and single electrode contacts. These questions are not currently fully answered by multislice computed tomography. METHODS: Four isolated temporal bone specimens were scanned in a current multislice computed tomography scanner and in two experimental flat-panel based volume computed tomography scanners before and after cochlea implantation. To compare flat-panel based volume computed tomography and multislice computed tomography, four features were rated according to the following criteria: 1) visibility of the cochlea; 2) visibility of the osseous spiral lamina; 3) discernibility of individual electrode contacts; and 4) the ability to determine the electrode array position relative to scala tympani and scala vestibuli. Layer-by-layer microgrinding pictures were used as the ground truth for verification of imaging findings. RESULTS: Flat-panel based volume computed tomography was superior to multislice computed tomography in all four features rated. The cochlea and facial nerve canal were much better delineated in flat-panel based volume computed tomography. The osseous spiral lamina and single electrode contacts were only visible in flat-panel based volume computed tomography. Assessment of implant position with regard to the cochlear spaces was considerably improved by flat-panel based volume computed tomography. CONCLUSION: Cochlear implantation assessment could be improved by flat-panel based volume computed tomography and, therefore, would be highly beneficial for cochlea implantation research and for clinical evaluation. However, these first results were shown by scanning isolated temporal bone specimens; scanning whole human skull bases might be more challenging.

Artifacts↗

Flat-panel-detector-based volumetric CT: performance evaluation of imaging for skeletal structures of small animals in comparison to multislice CT.

OBJECTIVES: The aim of this study was to compare the image performance of silicon-based flat-panel-detector-based volumetric computed tomography (fpVCT) to multislice spiral computed tomography (MSCT) for the visualization and detail detectability of skeletal structures in rodents of different development stages. MATERIALS AND METHODS: Rodents of different development stages were imaged with fpVCT (GE prototype with circular gantry with two 1024 x 1024, 200-microm pixel size, amorphous silicon/Cesium lodid (Csl) flat-panel detector) and eight-slice MSCT (LightSpeed Ultra). Imaging parameters (80 kVp, 100 mA) and the position of the rodents were identical in both techniques. Image quality, detail detectability, and contour of skeletal structures were judged by two observers in consensus using a 4-point scale (1 = unsatisfactory...4 = good). Findings were displayed and evaluated in axial slices, multiplanar reconstructions (MPR), maximum intensity projections (MIP) and volume rendering technique (VRT) in both modalities. Mean and standard of error of mean were calculated. RESULTS: In axial slices, visualization and detail detectability of very subtle skeletal structures, e.g., the basis of the skull was better in fpVCT than in MSCT (4 vs. 2 points). The MPRs of fpVCT showed less artifacts and more details than those of the MSCT. The MIPs and VRTs of the fpVCT demonstrated best image quality in all rodents of different development stages, whereas MSCT showed significant artifacts. CONCLUSION: fpVCT outperformed MSCT in imaging of small rodents. Due to the truly isotropic volume data set with high spatial resolution, fpVCT is a powerful tool in evaluating detailed skeletal structures.

Anatomy, Cross-Sectional↗