PubMed Health⌕ Search

Biomedical subjects

Christoph Pohl

Publications and source records attributed to Christoph Pohl.

12 recordsLinked to original sources

Homocysteine and carotid intima-media thickness in a german population: lack of clinical relevance.

BACKGROUND AND PURPOSE: Common carotid artery intima-media thickness (CCA IMT) is a predictor of stroke. This study aimed to analyze whether homocysteine (Hcys) metabolism influences CCA IMT. METHODS: We analyzed the association of personal, clinical, and biochemical data (multivariate analysis) and of 9 polymorphisms involved in Hcys metabolism (ANOVA) with CCA IMT in 714 individuals of 187 families. RESULTS: CCA IMT was significantly predicted by age, sex, creatinine levels, lipoprotein(a) levels, pack-years of smoking, the presence of hypertension, and the presence of diabetes mellitus but not by Hcys levels. Homozygosity for the T allele of the polymorphism methylenetetrahydrofolate reductase c.677C>T was significantly associated with higher Hcys levels but not with a higher CCA IMT. CONCLUSIONS: These data do not support the thesis that elevated Hcys levels are causally involved in cerebrovascular disease.

Aged↗

Günther Tulip filter retrievability multicenter study including CT follow-up: final report.

PURPOSE: To evaluate the safety and effectiveness of retrieval of the Günther Tulip inferior vena cava (IVC) filter. MATERIALS AND METHODS: This was a nonrandomized, single-armed, multicenter prospective investigation. Patients at temporary high risk for pulmonary embolism (PE) or deep vein thrombosis (DVT) who did not require a permanent filter were eligible. Forty-one patients received 42 Günther Tulip filters: 22 men and 19 women with a mean age of 47.7 years. Indications for filter placement included prophylaxis, PE, and DVT. Three months after filter retrieval, contrast agent-enhanced computed tomography of the abdomen, jugular vein ultrasonography, and clinical follow-up were performed. RESULTS: The filter retrieval rate was 57% (23 of 41). Günther Tulip filters were removed at a mean of 11.1 days (range, 2-14 d). The technical and clinical success rates for filter retrieval were both 100%. One placement complication and two protocol deviations occurred. These patients were excluded in terms of retrieval-related outcomes. One case of PE occurred with a filter in place, and one filter migrated to the heart. There were no acute complications caused by filter retrieval. At 3-month follow-up, there was no recurrent PE, DVT, jugular vein occlusion, or IVC stenosis or occlusion. CONCLUSION: In this multicenter study, retrieval of the Günther Tulip filter was safe and without recurrent thromboembolic events or evidence of IVC or jugular vein damage at 3-month follow-up.

Adult↗

Heritability of carotid artery atherosclerotic lesions: an ultrasound study in 154 families.

BACKGROUND AND PURPOSE: Ultrasound examination of the carotid arteries yields several quantitative measures that may serve as intermediate phenotypes in genetic studies. This study was undertaken to compare the heritabilities of 3 ultrasound measures: intima-media thickness (IMT), plaque score, and maximal stenosis. METHODS: We studied 565 individuals from 154 families ascertained by an affected parent with carotid artery atherosclerosis. IMT, plaque score, and maximal stenosis of the carotid arteries were examined by B-mode ultrasound and analyzed quantitatively. Heritability estimates were obtained by variance component analysis as implemented in the program SOLAR (sequential oligogenic linkage analysis routines). Covariates were age, sex, weight, height, body mass index (BMI), arterial hypertension, diabetes mellitus, amount of nicotine consumed, and plasma levels of low-density lipoprotein (LDL) and high-density lipoprotein (HDL) cholesterol, LDL/HDL ratio, lipoprotein(a) [Lp(a)], triglycerides, factor VIII, factor XIII, fibrinogen, and von Willebrand factor (vWF). RESULTS: After accounting for the covariables age, sex, hypertension, diabetes mellitus, and Lp(a), heritability of IMT was estimated as h2=0.61+/-0.17 (P=0.001). Variation of plaque score was influenced by age, sex, hypertension, diabetes mellitus, hypercholesterolemia, amount of nicotine consumed, factor VIII, and vWF. When these were considered, no significant heritability could be detected. Heritability of stenosis was estimated as h2=0.47+/-0.07 (P=0.006), with age, sex, BMI, hypertension, diabetes mellitus, amount of nicotine consumed, and LDL/HDL ratio as covariates. CONCLUSIONS: Among the 3 ultrasound measures studied, IMT had the highest heritability. IMT was strongly influenced by genetic determinants other than those influencing known risk factors. This makes IMT a promising candidate for use as an intermediate phenotype in genetic studies aiming to identify novel genes for atherosclerosis.

Adolescent↗

Silent and apparent cerebral embolism after retrograde catheterisation of the aortic valve in valvular stenosis: a prospective, randomised study.

BACKGROUND: In most patients, severity of valvular aortic stenosis can be accurately assessed non-invasively by echocardiography. However, retrograde catheterisation of the aortic valve is often undertaken. This procedure has a potential risk of neurological complications, with an unknown incidence of clinically silent embolism. We aimed to establish the frequency of clinically apparent and silent cerebral embolism after this procedure. METHODS: We prospectively randomised 152 consecutive patients with valvular aortic stenosis at a German university hospital to receive either cardiac catheterisation with (n=101) or without (n=51) passage through the aortic valve. Patients underwent cranial MRI and neurological assessment within 48 h before and after the procedure to assess cerebral embolism. Controls were 32 patients without valvular aortic stenosis who underwent coronary angiography and laevocardiography. FINDINGS: 22 of 101 patients (22%) who underwent retrograde catheterisation of the aortic valve had focal diffusion-imaging abnormalities in a pattern consistent with acute cerebral embolic events after the procedure; three of these patients (3%) had clinically apparent neurological deficits. By contrast, none of the patients without passage of the valve, or any of the controls, had evidence of cerebral embolism as assessed by MRI. INTERPRETATION: Patients with valvular aortic stenosis who undergo retrograde catheterisation of the aortic valve have a substantial risk of clinically apparent cerebral embolism, and frequently have silent ischaemic brain lesions. Patients should be informed about these risks, and this procedure should be used only in patients with unclear echocardiographical findings when additional information is necessary for clinical management.

Aortic Valve↗

[Neoadjuvant chemotherapy of primary hepatic non-Hodgkin's lymphoma].

BACKGROUND: Since primary malignant lymphomas of the liver represent a rare entity, no commonly accepted therapeutic strategy has been developed so far. CASE STUDY: We report the case of a diffuse large-cell B-cell lymphoma of the liver in a 48-year-old female patient. The tumor presented as a solitary mass measuring 12.5 cm in maximum diameter. After neoadjuvant chemotherapy, the lymphoma was completely resected (R0). A massive therapy-induced tumor regression was found histologically. No involvement of regional lymph nodes or other organs was detected during staging procedures (stage I EA). After six courses of adjuvant chemotherapy, the patient has been alive and well for more than 5 years and shows no evidence of tumor relapse. CONCLUSION: This case documents the effect of systemic chemotherapy on lymphoma cells. In many centers systemic chemotherapy is used as the only therapeutic regimen. Neoadjuvant chemotherapy might, however, represent an important addition to the therapeutic strategies concerning unilocular primary hepatic lymphomas.

Antineoplastic Combined Chemotherapy Protocols↗

Can particulate extraction from the ascending aorta reduce neurologic injury in cardiac surgery?

OBJECTIVE: This study examined whether extraction of particulate emboli using intra-aortic filtration could decrease neurologic outcomes. METHODS: Patients (N = 582) were enrolled in a prospective, controlled study and alternately assigned to the therapy arm (n = 304; intra-aortic filtration) or control arm (n = 278). Preoperative, procedural, and postoperative data were collected. Neurologic examinations included the National Institutes of Health Stroke Scale, Glasgow Coma Scale, and memory tests. Investigators administering neurologic tests were blinded to the study arm. By the use of logistic regression and propensity matching, composite neurologic outcomes (transient ischemic attack, stroke, delirium, coma, and memory deficit) were evaluated. RESULTS: Patients in the filter group experienced a lower incidence of adverse neurologic outcomes than patients in the control group (4.3% vs 11.9%) (P <.001). There were significantly less transient ischemic attacks (0% vs 1.4%), delirium (3.0% vs 6.5%), and memory deficit (1.3% vs 6.2%). There were fewer strokes in the filter group compared with the control group (0.7% vs 2.2%), although the sample size was too small for a significant finding. Both groups experienced 1 coma outcome. The use of a filter was associated with an adjusted odds ratio of 0.375, implying that a patient who does not receive a filter is 2.7 times more likely to experience an adverse neurologic event. Logistic modeling also demonstrated that there are increasing chances of poor neurologic outcome with increasing age. The model indicates that there may be an increasing protective benefit from the filter with increasing age, although the interaction was not significant. CONCLUSIONS: The extraction of particulate emboli using intra-aortic filtration resulted in decreased neurologic outcomes.

Aged↗

Echoscintigraphy: a new imaging modality for the reduction of color blooming and acoustic shadowing in contrast sonography.

The purpose of this study was to develop and evaluate a new imaging modality (echoscintigraphy) to reduce color blooming and acoustic shadowing in contrast sonography. After injection of various amounts (700 to 40,000 bubbles/mL) of the echo contrast agent SH-U 563A into a flow phantom, artificial vessels were insonated in the intermittent harmonic-power Doppler imaging (H-PDI) mode. The receive gain was varied from 50% to 75%. The cross-sectional area (CSA) of the tube was assessed using a new summation algorithm (echoscintigraphy) and a conventional single-frame analysis (S-FA) of the H-PDI-signals. Echoscintigraphy is based on the recording and summation of low-intensity signals that are emitted during the ultrasound (US)-induced destruction of microbubbles. Application of the summation algorithm at low-contrast concentration allowed a gain-independent automatic calculation of the CSA at medium and high gain settings. Using the S-FA method, the assessment of the vessel diameter and the CSA was gain-dependent and allowed correct measurements only from 60% to 65% gain. At a high receive-gain and high contrast concentration, S-FA resulted in an overestimation of the CSA up to 35.5%. Echoscintigraphy allows correct display of contrast-filled vessels over a wide range of gain settings at low contrast concentrations, where S-FA does not adequately display echo contrast. Thus, echoscintigraphy minimizes artefacts resulting from color blooming and acoustic shadowing.

Algorithms↗

Cooling improves the writing performance of patients with writer's cramp.

Cooling of hand and forearm muscles by immersion in 15 degrees C cold water for 5 minutes improved the writing performance of patients with writer's cramp. Since abnormal processing of muscle spindle afferent discharges contributes to the pathology of writer's cramp, this effect might result from a reduction in muscle spindle activity by lowering muscle temperature. Cooling is a simple, cheap, and safe procedure, providing temporary relief for patients with writer's cramp.

Adult↗

On the design of a capillary flow phantom for the evaluation of ultrasound contrast agents at very low flow velocities.

Recently, a new imaging technology has become available that allows the evaluation of tissue perfusion using echo-contrast agents in real-time imaging: power pulse inversion imaging (PPI). Although numerous in vitro phantoms have been designed for different imaging modalities in ultrasound (US), there is a need for a phantom that mimics microcirculation and allows, in particular, the assessment of contrast replenishment kinetics following US-induced destruction of microbubbles using the new method. We, therefore, designed a new capillary flow phantom that takes the requirements of the new US imaging techniques and the physical properties of microbubbles into account and serves flow velocities in the range of microcirculation (1 to 10 mm/s). PPI studies were performed in the newly designed phantom. The contrast agent used was AF0150. We studied homogeneity of contrast distribution within the capillary phantom, constancy of contrast infusion, the dose-effect relationship and, finally, the feasibility of flow assessment using the method of contrast replenishment following US-induced microbubble destruction in a flow velocity range of 2.1 to 9.45 mm/s. Analysis of the replenishment kinetics was performed using the mathematical model f(t) = A(1 - e(-beta t)), with A representing the blood volume and beta the microbubble velocity. The new capillary phantom allowed homogeneous contrast opacification within the perfused capillaries independently of the flow. Constancy of signal intensity was achieved over a time period of almost 2 h, indicating constant contrast delivery. A strong linear correlation between the PPI signal and the contrast dose was found (r = 0.998). Analysis of the replenishment parameters revealed a strong linear relationship between parameter beta and flow (r = 0.994) as well as A * beta and flow (r = 0.984) in the observed flow range. The newly designed perfusion phantom for the evaluation of echo-contrast replenishment kinetics fulfills, at very low flow velocities, important prerequisites such as constancy of contrast delivery, homogeneity of contrast signals, linear dose-effect relation and minimal attenuation. Thus, the new phantom allows standardized analysis of contrast replenishment kinetics using real-time perfusion imaging techniques at flow velocities comparable to those of the microcirculation.

Blood Flow Velocity↗

Circulating adhesion molecules in patients with internal carotid artery stenosis.

To study the association of plasma concentrations of soluble adhesion molecules (sICAM-1, sVCAM-1 and sE-selectin) with atheroslerotic lesions at the origin of the internal carotid artery (ICA). 179 subjects were investigated by color Doppler ultrasound of whom 133 had and 46 had no plaques at the ICA origin. Stepwise logistic regression analysis revealed that hypertension (p < 0.001), sICAM-1 concentrations (p < 0.01) and smoking (p < 0.05) were independently associated with the presence of ICA plaques. Multivariate regression analysis revealed that sICAM-1 concentrations in subjects with plaque were negatively associated with the degree of ICA stenosis (p < 0.01) and positively associated with previous cerebral ischemia (p < 0.01), coronary heart disease (p < 0.05) and peripheral artery disease (p < 0.05). In conclusion, elevated sICAM-1 concentrations are independently associated with atherosclerosis of the ICA origin and are predominantly increased in patients with low-grade lesions and with clinical manifestations of vascular disorders.

Aged↗

Real-Time Contrast Echo Assessment of Myocardial Perfusion at Low Emission Power: First Experimental and Clinical Results Using Power Pulse Inversion Imaging.

Power pulse inversion (PPI) has been developed for echocontrast specific imaging in order to reduce destruction of microbubbles. The purpose of this study was to evaluate PPI for real-time contrast echocardiography. Therefore, in vitro studies in a physiological flow-phantom and clinical examinations in patients with coronary artery disease were performed. The in vitro rersults of this study indicate that PPI allows real-time imaging at low emission power and is almost nondestructive to contrast microbubbles of Definity. At this low emission power a strong linear relationship between the dosage of the contrast agent and the resulting PPI signal intensity was found (R = 0.998, p < 0.001). In the clinical examinations real-time imaging using low mechanical index PPI resulted in strong myocardial signals and a complete filling of the cavities indicating absence of bubble destruction. Most striking was the ability of PPI to display myocardial thickening and wall motion simultaneously with the assessment of myocardial contrast replenishment following ultrasound induced bubble destruction by high power frames. We conclude that PPI allows nondestructive contrast imaging both in experimental and clinical settings. Therefore, real-time imaging of myocardial perfusion and real-time assessment of contrast replenishment following ultrasound induced destruction of microbubbles is feasible. Moreover, PPI allows simultaneous assessment of perfusion and myocardial function.

Journal Article↗

Improvement in Endocardial Border Delineation Using Tissue Harmonic Imaging.

BACKGROUND AND METHODS: For years, tissue has been assumed to be a linear medium in diagnostic ultrasound applications; thus, no backscattered signals in the second harmonic band are expected in harmonic imaging without the injection of a contrast agent. However, it has been shown that a useful tissue image is formed even without a contrast agent. The aim of this study was to evaluate whether this tissue harmonic image provided improved visualization of endocardial borders. Fifty-six adult patients with various heart diseases were investigated using conventional two-dimensional echocardiography and tissue harmonic imaging. In 30 of these patients, the left ventricular endocardial borders were well defined in the standard parasternal and apical views using conventional two-dimensional echocardiography. In the remaining 26 patients, delineation of endocardial borders was not possible in at least two segments. The equipment used was an ATL HDI-3000 diagnostic system equipped with harmonic imaging. RESULTS: In all 56 patients, the myocardium and valves could be imaged with tissue harmonic imaging. Harmonic recordings were sharper and contained fewer clutter artifacts than conventional recordings. Most striking was the enhancement of left ventricular endocardial borders. In the 26 patients with incomplete delineation of left ventricular endocardial borders, wall motion could be evaluated in 290 of 312 (93%) segments with tissue harmonic imaging compared with only 168 of 312 (54%) segments with conventional echocardiography (P < 0.001). CONCLUSIONS: Tissue harmonic imaging improves image quality and can be used to enhance the definition of left ventricular endocardial borders. These findings can be explained by the nonlinear propagation of ultrasound within the tissue, which results in distortion of the transmitted signal and, thus, harmonic generation.

Journal Article↗