Retention behavior of C1-C6 aliphatic monoamines on anion-exchange and polymethacrylate resins with heptylamine as eluent.

Retention behavior of C1-C6, aliphatic monoamines (methylamine, ethylamine, propylamine, butylamine, amylamine and hexylamine) on columns (150 mm x 6 mm i.d.) packed with various anion-exchange resins (styrene-divinylbenzene (PS-DVB) copolymer-based strongly basic anion-exchange resin: TSKgel SAX, polymethacrylate-based strongly basic anion-exchange resin: TSKgel SuperQ-5PW and polymethacrylate-based weakly basic anion-exchange resin: TSKgel DEAE-5PW) and unfunctionized polymethacrylate resins (TSKgel G5000PW and TSKgel G3000PWXL) was investigated with basic solutions (sodium hydroxide and heptylamine) as the eluents. Due to strongly electrostatic repulsion (ion-exclusion effect) between these anion-exchange resins and these amines, peak resolution between these amines on these anion-exchange resin columns was unsatisfactory with both sodium hydroxide and heptylamine as the eluents. In contrast, these polymethacrylate resins were successfully applied as the stationary phases for the separation of these C1-C6 amines with heptylamine as eluent, because of both small hydrophobicity and small cation-exchange ability of these resins. Excellent simultaneous separation, highly sensitive conductimetric detection and symmetrical peaks for these C1-C6 amines were achieved on the TSKgel G3000PWXL column in 35 min with 5 mM heptylamine at pH 11.1 as the eluent.

Amines↗

Split flow and bypass flow systems for monolithic capillary columns in liquid chromatography.

Split flow and bypass flow systems were assembled using Nano Y Connectors with low dead volume commercially available for capillary liquid chromatography (LC). The split ratio could be controlled by changing the dimension of restriction tubing and applied back pressure to the restriction tubing. The split flow system allowed us to use valve injectors and pumps commercially available for capillary LC. The reproducibility of the present split flow system was acceptable. The relative standard deviation for six successive measurements was 0.4% for the retention time, whereas that for the peak height and peak area was 1-3% depending on the analytes. The bypass flow system uses two Nano Y Connectors, where the eluent split at the first Nano Y Connector, which is located in the inlet of the separation column, is merged again into the effluent from the column at the second Nano Y Connector. The bypass flow system could avoid on-column detection and allowed us to use flow cells, leading to an approximate three times improvement in signal-to-noise. The present flow systems were evaluated by using aromatic hydrocarbons and alkylbenzenes as test analytes.

Chromatography, Liquid↗

Separation of aliphatic carboxylic acids and benzenecarboxylic acids by ion-exclusion chromatography with various cation-exchange resin columns and sulfuric acid as eluent.

The application of various hydrophilic cation-exchange resins for high-performance liquid chromatography (sulfonated silica gel: TSKgel SP-2SW, carboxylated silica gel: TSKgel CM-2SW, sulfonated polymethacrylate resin: TSKgel SP-5PW, carboxylated polymethacrylate resins: TSKgel CM-5PW and TSKgel OA-Pak A) as stationary phases in ion-exclusion chromatography for C1-C7 aliphatic carboxylic acids (formic, acetic, propionic, butyric, isovaleric, valeric, isocaproic, caproic, 2-methylhexanoic and heptanoic acids) and benzenecarboxylic acids (pyromellitic, trimellitic, hemimellitic, o-phthalic, m-phthalic, p-phthalic, benzoic, salicylic acids and phenol) was carried out using diluted sulfuric acid as the eluent. Silica-based cation-exchange resins (TSKgel SP-2SW and TSKgel CM-2SW) were very suitable for the ion-exclusion chromatographic separation of these benzenecarboxylic acids. Excellent simultaneous separation of these benzenecarboxylic acids was achieved on a TSKgel SP-2SW column (150 x 6 mm I.D.) in 17 min using a 2.5 mM sulfuric acid at pH 2.4 as the eluent. Polymethacrylate-based cation-exchange resins (TSKgel SP-5PW, TSKgel CM-5PW and TSKgel OA-Pak A) acted as advanced stationary phases for the ion-exclusion chromatographic separation of these C1-C7 aliphatic carboxylic acids. Excellent simultaneous separation of these C1-C7 acids was achieved on a TSKgel CM-5PW column (150 x 6 mm I.D.) in 32 min using a 0.05 mM sulfuric acid at pH 4.0 as the eluent.

Benzene Derivatives↗

Comparison of monomeric and polymeric chiral stationary phases.

Two-type polymeric chiral stationary phases (pCSPs) were prepared by surface grafting of chiral acryl-type monomers on a silica gel surface modified with 3-(trimethoxysilyl)propylmethacrylate. The prepared pCSPs were characterized by IR, Fr-Raman, scanning electron microscopy, and elemental analysis. In addition, two-type monomeric chiral stationary phases (mCSPs) were also prepared. The racemic analytes were separated using the prepared mCSPs and pCSPs. The separation factor (alpha) and capacity factor (k1) of the racemic analytes for the pCSP and mCSP were compared. The alpha and k1 values of the mCSP were higher than those of the pCSP.

Chromatography, Liquid↗

Surface grafting of glycidyl methacrylate on silica gel and polyethylene beads.

Surface grafting of glycidyl methacrylate (GMA) on silica gel and a polyethylene bead was performed by radical polymerization and radiation-induced polymerization, respectively, in order to improve softness. Subsequently, diethylene triamine (DETA), triethylene tetraamine (TETA), and iminodiacetic acid (IDA) were introduced to the grafted GMA for use as affinity columns. The efficiency of the affinity column was investigated by use of bovine serum albumin (BSA) and hemoglobin (Hb) as model proteins. The affinity degree of BSA was higher than Hb for the DETA and TETA column, whereas the affinity degree of Hb was higher than BSA for the IDA column supported by silica gel. The affinity degree of BSA was higher than Hb for the DETA and TTA column supported by polyethylene (PE) beads.

Amines↗

Pressure-controlled on-column injection method for microcolumn liquid chromatography.

A pressure-controlled on-column injection method was developed for microcolumn liquid chromatography. The system was assembled from a syringe pump, a Model M-445 Six-Way Micro Selection Valve, a separation column and a UV detector. The injection volume could be regulated by changing the applied pressure and/or the sample loading time. The system was evaluated in the ion-exchange mode. The system was applied to the determination of anions in river-water samples.

Journal Article↗

Titanium dioxide coated surfaces for capillary electrophoresis and capillary electrochromatography.

The potential of titanium dioxide coatings to control the electroosmotic flow and to affect the migration behavior of analytes in capillary electrophoresis and open-tubular capillary electrochromatography was evaluated. The inner wall of a fused-silica capillary was applied with a solution of a titanium peroxo complex, followed by heating at an elevated temperature. The resultant product was ascertained to be titanium dioxide in a crystalline form of anatase by the results of Fourier transform-infrared spectrometry (FT-IR), X-ray photoelectron spectroscopy, and Raman spectroscopy. The capillary thus made had anodic or cathodic electroosmotic flow, depending on the pH and composition of the background electrolyte used. The titanium dioxide surface of the capillary was readily modified by a silanizing reagent. The performance of the titanium dioxide surfaces with or without chemical modifications was examined with inorganic anions, neutral compounds and peptides.

Anions↗

Enantiomer separation by capillary electrochromatography using fritless packed columns.

This review summarizes recent developments in the field of enantiomer separation by capillary electrochromatography using fritless packed columns. Various enantiomers have been separated by employing fritless packed columns prepared in a fused silica capillary either by the immobilization of chiral packing materials by sintering or sol-gel technology or by in situ polymerization of a mixture containing chiral selectors. The details of the column preparation procedures and the attainable column performance are described.

Chromatography↗

An attempt directed toward enhanced shape selectivity in reversed-phase liquid chromatography: preparation of the dodecylaminated beta-cyclodextrin-bonded phase.

With the aim of preparing a stationary phase with a high shape-recognition ability for liquid chromatography, a new bonded phase was synthesized by coupling multiply dodecylamino-substituted beta-cyclodextrin (beta-CD) to 3-glycidoxypropyl-derivatized silica gel. The stationary phase prepared in this way was expected to have increased shape selectivity compared with that of conventional reversed-phase materials, due to solute interactions with the alkyl chain piles built up on the beta-CDs bonded to silica. The separation characteristics of the bonded phase were investigated using polycyclic aromatic hydrocarbons (PAHs) with different molecular shapes and compared with those of monomeric ODS and native beta-cyclodextrin-bonded phases. The newly developed stationary phase was found to be highly selective for PAHs.

Amines↗