Theoretical modeling and experimental evaluation of a microscale molecular mass sensor.

A theoretical model for a recently developed microscale molecular mass sensor (micro-MMS) is presented. The micro-MMS employs a widely applicable technique of measuring the refractive index gradient (RIG) in a microchannel created after two adjacent streams merge: a "sample stream" containing analyte(s) of interest in a host solvent and a "mobile-phase" stream containing only the host solvent. Because the flow in the microchannel is laminar, the analytes in the sample stream mix with the mobile-phase stream primarily by diffusion. The diffusion-induced RIG in the microchannel is measured by monitoring the deflection angle of a diode laser probe beam, which is orthogonal to both the direction of flow and the direction of analyte diffusion. The micro-MMS samples the RIG with probe beams at two positions along the direction of flow, and the ratio of the downstream to the upstream signal monitors the diffusion coefficient. Following calibration for a given class of compounds, the molecular mass of an analyte of interest can be determined. Along with the analyte diffusion coefficient, the theoretical model indicated three other specific parameters are important to interpret the micro-MMS output: the radius of the interrogating light probe beams, the time intervals between each of the detection positions, and the merge point relative to the detection positions. A series of experiments were conducted at different beam radii and flow rates to investigate these parameters, and the results are consistent with the model. The model shows that by using smaller beam radii and altering flow rates the molecular mass range of the micro-MMS can be, in principle, tuned from less than 10(2) g/mol to greater than 10(8) g/mol. The ratio data from the micro-MMS is also demonstrated to readily provide a "universal calibration", from which the determination of unknown diffusion coefficients can be readily obtained.

Journal Article↗

Diffusion coefficient measurement in a microfluidic analyzer using dual-beam microscale-refractive index gradient detection. Application to on-chip molecular size determination.

We report a microchip-based detection scheme to determine the diffusion coefficient and molecular mass (to the extent correlated to molecular size) of analytes of interest. The device works by simultaneously measuring the refractive index gradient (RIG) between adjacent laminar flows at two different positions along a microchannel. The device, referred to as a microscale molecular mass sensor (micro-MMS), takes advantage of laminar flow conditions where the mixing of two streams occurs essentially by diffusion across the boundary between the two streams. Two flows merge on the microchip, one containing solvent only, referred to as the mobile phase stream and one which contains the analyte(s) of interest in the solvent, i.e. the sample stream. As these two streams merge and flow parallel to each other down the microchannel a RIG is created by the concentration gradient. The RIG is further influenced by analyte diffusion from the sample stream into the mobile phase stream. Measuring the RIG at a position close to the merging point (upstream signal) and simultaneously a selected distance further down the microchannel (downstream signal) provides real-time data related to the extent a given analyte has diffused, which can be readily correlated to analyte molecular mass by taking the ratio of the downstream-to-upstream signals. For the dual-beam RIG measurements, a diode laser output is coupled to a single mode fiber optic splitter with two output fibers. Light from each fiber passes through a graded refractive index (GRIN) lens forming a collimated beam that then passes through the microchannel and then on to a position sensitive detector (PSD). The RIG at both detection positions deflects the two collimated probe beams. The deflection angle of each beam is then measured on two separate PSDs. The micro-MMS was evaluated using polyethylene glycols (PEGs), sugars, and as a detector for size-exclusion chromatography (SEC). Peak purity can be readily identified using the micro-MMS with SEC. The limit of detection was 0.9 ppm (PEG at 11 840 g/mol) at the upstream detection position corresponding to a RI limit of detection (LOD) (3sigma) of 7-10(-8) RI. The pathlength for the RIG measurement was 200 microm and the angular LOD was 0.23 micro(rad) with a detection volume of 8 nl at both positions. The average molecular mass resolution was 9% (relative standard deviation) for a series of PEGs ranging in molecular mass from 106 to 22 800 g/mol. With this excellent mass resolution, small molecules such as monosaccharides, disaccharides, and so on, are readily distinguished. The sensor is demonstrated to readily determine unknown diffusion coefficients.

Chromatography, Gel↗

A microscale-molecular weight sensor: probing molecular diffusion between adjacent laminar flows by refractive index gradient detection.

A detection scheme that measures the refractive index gradient (RIG) between adjacent laminar flows in a microfluidic device has been used to develop a microscale-molecular weight sensor. The behavior of low Reynolds number flows has been well documented and shows that molecular transport (mixing) between adjacent laminar flows occurs by molecular diffusion between flow boundaries. A diode laser beam, incident upon and illuminating the entire width of a microchannel, measured the transverse concentration gradient at two different positions along a microchannel. The concentration gradient is impacted by the transverse diffusion from a flow with analyte into a flow initially without analyte. The RIG that forms as analyte diffuses from one adjacent flow to the other causes the laser beam, impinging orthogonal to the RIG through the microchannel, to be deflected. The angle of deflection is then monitored on a position-sensitive detector (PSD) at two different positions along the axis of flow to provide a measurement of analyte diffusion. The two positions are just after the flow initially without analyte merges with the flow initially containing all of the analyte (upstream) and then after the two streams have had more time to diffuse together (downstream). The ratio of the PSD signals obtained at the two positions along the flow, downstream signal divided by the upstream signal, is readily correlated to the analyte diffusion coefficient and, thus, the analyte molecular weight for a given class of compounds. The device was evaluated as a molecular weight sensor for poly(ethylene glycol) (PEG) solutions over a molar mass range from 106 to 22,800 g/mol. The ratio signal was found to be both independent of PEG concentration and sensitive to molecular weight changes for samples ranging from 960 to 22,800 g/mol. Independence of concentration is important for obtaining a reliable molecular weight measurement. The limit of detection for 11,840 g/mol PEG measured at the upstream detection position was determined to be 56 ppm, equivalent to 4.5 x 10(-6) RI (3sigma). This technique provides a much needed universal detection method, without requiring analyte derivatization chemistry (e.g., fluorescence), for microfluidic analyses that are becoming increasingly useful in monitoring chemical systems such as continuous-flow reactors or batch polymerization processes. Thus, the molecular weight determination capability is potentially applicable to other compound classes, such as DNA or proteins.

Journal Article↗

Toward a fully integrated positive-pressure driven microfabricated liquid analyzer.

A versatile integrated analyzer with a flow-programmed injection strategy and multiwavelength detection is described with applications toward sampling, flow injection analysis, and capillary separations. Continuous near-real-time sampling is a major benefit of the flow-programmed injection technique. Injection volumes ranging from 250 pL to several microliters were made without electrophoretic flow. Multiwavelength grating light reflection spectroscopy (GLRS) and transmission absorbance spectroscopy were performed simultaneously in a detection volume of 150 pL. The utility of these detection methods for refractive index (RI) and absorbance detection in capillary channels is demonstrated through analysis of salt, indicator, and dyes. GLRS is a unique, selective, and path-length-independent technique for probing RI, absorbance, and other optical properties. A limit of detection (LOD) of 170 microM was achieved for GLRS interferometric detection of FD&C Red #3, which corresponded to 2.6 fmol of analyte in the 150-pL detection volume. A LOD of 2 mM for phosphate buffer, or 3 fmol in the 150-pL detection volume will also be demonstrated. A siloxane coating on the GLRS grating was employed as a sensing layer to probe interactions between the sample and stationary phase. The combined GLRS interferometric response provided insight into both optical and chromatographic properties of samples. Open tubular capillary liquid chromatography with multidimensional multiwavelength detection is demonstrated for the analysis of three food dyes. Separation efficiency, N, of 16,000 was achieved for an unretained dye peak eluting at 12 min. Integration of novel sampling and detection schemes makes this a broadly applicable liquid analyzer.

Journal Article↗