PubMed Health⌕ Search

PubMed · 14604110

Diffusion coefficient measurement in a microfluidic analyzer using dual-beam microscale-refractive index gradient detection. Application to on-chip molecular size determination.

Abstract

We report a microchip-based detection scheme to determine the diffusion coefficient and molecular mass (to the extent correlated to molecular size) of analytes of interest. The device works by simultaneously measuring the refractive index gradient (RIG) between adjacent laminar flows at two different positions along a microchannel. The device, referred to as a microscale molecular mass sensor (micro-MMS), takes advantage of laminar flow conditions where the mixing of two streams occurs essentially by diffusion across the boundary between the two streams. Two flows merge on the microchip, one containing solvent only, referred to as the mobile phase stream and one which contains the analyte(s) of interest in the solvent, i.e. the sample stream. As these two streams merge and flow parallel to each other down the microchannel a RIG is created by the concentration gradient. The RIG is further influenced by analyte diffusion from the sample stream into the mobile phase stream. Measuring the RIG at a position close to the merging point (upstream signal) and simultaneously a selected distance further down the microchannel (downstream signal) provides real-time data related to the extent a given analyte has diffused, which can be readily correlated to analyte molecular mass by taking the ratio of the downstream-to-upstream signals. For the dual-beam RIG measurements, a diode laser output is coupled to a single mode fiber optic splitter with two output fibers. Light from each fiber passes through a graded refractive index (GRIN) lens forming a collimated beam that then passes through the microchannel and then on to a position sensitive detector (PSD). The RIG at both detection positions deflects the two collimated probe beams. The deflection angle of each beam is then measured on two separate PSDs. The micro-MMS was evaluated using polyethylene glycols (PEGs), sugars, and as a detector for size-exclusion chromatography (SEC). Peak purity can be readily identified using the micro-MMS with SEC. The limit of detection was 0.9 ppm (PEG at 11 840 g/mol) at the upstream detection position corresponding to a RI limit of detection (LOD) (3sigma) of 7-10(-8) RI. The pathlength for the RIG measurement was 200 microm and the angular LOD was 0.23 micro(rad) with a detection volume of 8 nl at both positions. The average molecular mass resolution was 9% (relative standard deviation) for a series of PEGs ranging in molecular mass from 106 to 22 800 g/mol. With this excellent mass resolution, small molecules such as monosaccharides, disaccharides, and so on, are readily distinguished. The sensor is demonstrated to readily determine unknown diffusion coefficients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Colin D Costin, Roy K Olund, Bethany A Staggemeier, Ana Kristine Torgerson, Robert E Synovec. 2003-09-26. Diffusion coefficient measurement in a microfluidic analyzer using dual-beam microscale-refractive index gradient detection. Application to on-chip molecular size determination.. https://doi.org/10.1016/s0021-9673(03)01101-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A new scaleable freeze-thaw technology for bulk protein solutions.

A new method of freeze-thaw is described using experimental data obtained from freezing of purified rhGH (recombinant human growth hormone). The method is based on freezing protein solutions in rectangular rather than cylindrical containers. It is hypothesized that the change in container geometry allows for linear scale-up of the freeze-thaw operation based on equivalency of temperature-time profile. The hypothesis is tested using freeze-thaw data from a miniature (30 ml) and a 2.4 litre container. Computational fluid dynamics techniques are used to simulate the freeze process and the simulations are compared with experimental results. Protein quality is assessed as a function of freeze conditions using dynamic light scattering, circular CD, size-exclusion and reverse-phase HPLC measurements. The results demonstrate the applicability of the new approach. Freezing of rhGH solution at concentrations of approx. 30 mg/ml is shown to be possible with no damage to the molecule for up to five cycles of freeze-thaw. A nitrogen blast chest-freezer is designed and evaluated as part of the process. The refrigeration system and the freeze-thaw method can be used to freeze-thaw bulk protein solutions for development work and has the potential for transfer to manufacturing.

Chromatography, Gel↗

Ultrafiltration characteristics of pegylated proteins.

There is growing clinical interest in the use of pegylated recombinant proteins with enhanced stability, half-life, and bioavailability. The objective of this study was to develop a quantitative understanding of the ultrafiltration characteristics of a series of pegylated proteins with different degrees of pegylation. Sieving data were compared with available theoretical models and with corresponding results for the partition coefficient in size exclusion chromatography (SEC). The sieving coefficients of the pegylated proteins depended not only on the protein size and the total molecular weight of the polyethylene glycol (PEG) but also on the number of PEG chains. This is in sharp contrast to the partition coefficient in SEC, which was uniquely determined by the total molecular weight of the PEG and protein. This difference is due to the deformation and/or elongation of the PEG chains caused by the convective flow into the membrane pores, an effect that is not present in SEC. These results provide important insights into the transport and separation characteristics of pegylated proteins.

Chromatography, Gel↗

Nm23-H1/NDP kinase folding intermediates and cancer: a hypothesis.

The Nm23-H1/nucleoside diphosphate (NDP) kinase A is a metastasis suppressor, besides its enzymatic activity. The mutant S120G has been found in high-grade neuroblastomas. The mutant protein, once denatured in urea, is unable to refold in vitro. A size-exclusion chromatography analysis of the folding/association pathway showed that recombinant wild-type and S120G mutant human Nm23-H1/NDP kinase A unfold and refold passing through a molten globule state while typical hexameric NDP kinases unfold without dissociated species and refold through a native monomeric intermediate. A survey of the recent literature showed that several proteins involved in cancer, and their mutants, are marginally stable, like the wild-type Nm23-H1/NDP kinase A, or are misfolded, like its S120G mutant. We therefore suggest that the low thermodynamic stability and the folding intermediate of the Nm23-H1/NDP kinase A may be necessary for its regulatory properties.

Chromatography, Gel↗