Benchmark data from the literature for evaluation of new glucose sensing technologies.

New glucose sensors based on various technologies are being developed to provide information for improved therapy in diabetes. There is a need to establish rational performance standards for these sensors. Frequently sampled, direct blood glucose recordings representative of blood glucose excursions in diabetes are the "gold standard." An extensive literature search revealed a limited number of diabetic and nondiabetic blood glucose recordings suitable for this purpose. Certain blood glucose recordings reflect the diversity of glycemic dynamics and provide sufficient challenge for evaluation of sensor systems. These recordings were converted into an accessible electronic format. An example is given of the use of these benchmark data to estimate aliasing error, or the error due to insufficient sampling frequency, based on a hypothetical sensor system having some properties of conventional "fingerstick" systems. Discrete sampling systems accumulate substantial aliasing error as the sampling period increases.

Biosensing Techniques↗

Predicting protein--protein interactions from primary structure.

MOTIVATION: An ambitious goal of proteomics is to elucidate the structure, interactions and functions of all proteins within cells and organisms. The expectation is that this will provide a fuller appreciation of cellular processes and networks at the protein level, ultimately leading to a better understanding of disease mechanisms and suggesting new means for intervention. This paper addresses the question: can protein-protein interactions be predicted directly from primary structure and associated data? Using a diverse database of known protein interactions, a Support Vector Machine (SVM) learning system was trained to recognize and predict interactions based solely on primary structure and associated physicochemical properties. RESULTS: Inductive accuracy of the trained system, defined here as the percentage of correct protein interaction predictions for previously unseen test sets, averaged 80% for the ensemble of statistical experiments. Future proteomics studies may benefit from this research by proceeding directly from the automated identification of a cell's gene products to prediction of protein interaction pairs.

Artificial Intelligence↗

Simulations of the frequency response of implantable glucose sensors.

The response of enzyme electrode glucose sensors implanted in tissues to physiologic blood glucose oscillations is simulated. Models describe both oxygen-based and peroxide-based glucose sensors in spatially homogeneous medium simulating some mass transfer properties of tissue. Pass-through ratios and delays are reported as a function of frequency for the oxygen-based sensor, and the effects on continuous blood glucose monitoring are illustrated using data from the literature. Certain peroxide-based sensor designs may produce common signals for different glucose concentrations, a characteristic not found in oxygen-based sensors. The dynamic response depends on the frequency of glucose oscillation and is sensitive to sensor type, enzyme activity, and diffusional resistance.

Algorithms↗

Immobilized glucose oxidase in implantable glucose sensor technology.

Glucose oxidase has had a central role in previous glucose sensing methods and is key to the development of certain new glucose sensors. The immobilized enzyme is specific for glucose and sufficiently long-lived for many sensor applications, but new glucose sensing applications may place increased demands on the enzyme.

Biosensing Techniques↗

Is blood glucose predictable from previous values? A solicitation for data.

An important question about blood glucose control in diabetes is, Can present and future blood glucose values be predicted from recent blood glucose history? If this is possible, new continuous blood glucose monitoring technologies under development may lead to qualitatively better therapeutic capabilities. Not only could continuous monitoring technologies alert a user when a hypoglycemic episode or other blood glucose excursion is underway, but measurements may also provide sufficient information to predict near-future blood glucose values. A predictive capability based only on recent blood glucose history would be advantageous because there would be no need to involve models of glucose and insulin distribution, with their inherent requirement for detailed accounting of vascular glucose loads and insulin availability. Published data analyzed here indicate that blood glucose dynamics are not random, and that blood glucose values can be predicted, at least for the near future, from frequently sampled previous values. Data useful in further exploring this concept are limited, however, and an appeal is made for collection of more.

Blood Glucose↗

Role of xanthine oxidase in hydrogen peroxide production.

Increased production of oxygen free radicals may play a role in many diseases such as hypertension. As evidence indicates that xanthine oxidase may be involved in creating these reactive oxygen species, experiments were performed to additionally characterize hydrogen peroxide (H2O2) production in xanthine oxidase catalyzed reactions. In vitro measurements of hydrogen peroxide production from the xanthine/xanthine oxidase reaction were performed in buffered saline using an electrochemical technique, and the effect of allopurinol on inhibition of xanthine oxidase was determined. Experiments were also performed in blood plasma to characterize endogenous hydrogen peroxide producing capability and xanthine oxidase activity. In the presence of sodium azide, an inhibitor of catalase, peroxide production was measured in plasma after adding xanthine or xanthine oxidase and the results were similar to those obtained in buffered saline. When only sodium azide was added to plasma, hydrogen peroxide was produced at a level of 36.1 +/- 7.6 microM (n = 5). From these measurements, endogenous xanthine oxidase activity was estimated to be 6.5 +/- 0.3 mU/ml (n = 5). These results suggests that sufficient substrate exists in plasma to produce micromolar levels of hydrogen peroxide and xanthine oxidase may catalyze these reactions.

Allopurinol↗

Toward prediction of physiological state signals in sleep apnea.

A recurrent connectionist model is described to predict dynamic respiratory state in the apneic sleeping patient. The time-domain model of nonlinear time-lagged interactions between heart rate, respiration, and oxygen saturation was developed to implicitly embed the dynamics of the respiration and cardiovascular control systems. Multiple future time scales were enforced on the network during training to explore the limits of the prediction horizon and produce a global representation of dynamic state trajectory. Predicted apneic respiration state results are presented in terms of invariant geometric statistics (largest Lyapunov exponent lambda L and correlation dimension Dc). The lambda L prediction error was 13%, while Dc error was within 9% of the true time series value. The magnitude of these errors may fall within experimental noise levels. This methodology may eventually be useful in dynamic control of continuous positive airway pressure (CPAP) therapy devices, and may lead to increased patient compliance with this therapy.

Heart Rate↗

Advances and prospects in glucose assay technology.

The evolution of glucose assay methods has been central to the development of present therapies for diabetes mellitus. However, new blood glucose assay capabilities, such as convenient and truly continuous monitoring, are now needed to foster a new era of close blood glucose control. The principles and present status of glucose sensors being developed that may fill these requirements are reviewed here.

Animals↗

Accuracy of least squares designed spatial FIR filters for segmentation of images of fluorescence stained cell nuclei.

A method for accurate, real-time image segmentation is needed for the development of a fully automated image cytometer that combines the speed and case-of-use of flow cytometry with the detailed morphometry of imaging. Object intensity variation and inherent optical blur make real-time segmentation challenging. The best spatial finite impulse response (FIR) filter, implemented as a convolution, was tested for sharpening edges and creating the required contrast. The filter and threshold segmentation steps were treated as a two-category linear classifier. Best 3 x 3 through 25 x 25 filters were designed utilizing the perceptron criterion and nonlinear least squares, and tested on ten montage images of a combined 1,070 manually segmented DAPI stained cell nuclei. The resulting image contrast, or class separation, led to simple automatic thresholding via the histogram intermodal minimum. Image segmentation accuracy began to plateau at 7 x 7 filters and did not increase above 15 x 15. Little loss in accuracy occurred with application to the images not used for design. This segmentation method provides a systematic, fast and accurate means of creating binary object maps useful for subsequent measurement, processing and cell classification.

3T3 Cells↗

Dynamic delay and maximal dynamic error in continuous biosensors.

When biosensors are operated continuously, a dynamic delay and a dynamic error relate the sensor signal to the changing analyte concentration. The dynamic delay is the temporal displacement of the signal, or the lag, and is specified solely by properties of the biosensor and external mass transfer. The dynamic error is the difference between the actual concentration and the simultaneous reported concentration and is the product of the dynamic delay and the instantaneous rate of concentration change. In real-time operation of sensors, a maximal dynamic error based on the maximal expected rate of concentration change must be employed to estimate the worst-case error because the actual instantaneous rate is not independently known. Values of dynamic delay and maximal dynamic error that are acceptable in particular monitoring situations can be used in the design of acceptable continuous biosensors. This analysis suggests experimental alternatives to the standard response time approach for sensor characterization that are particularly advantageous for continuously operated biosensors. The concepts are applied here to in vitro operation of a continuous glucose sensor.

Biosensing Techniques↗

Comparison of phase-contrast and fluorescence digital autofocus for scanning microscopy.

Reliable autofocus is required to obtain accurate measurements of fluorescent stained cellular components from a system capable of scanning multiple microscope fields. Autofocus could be performed directly with fluorescence images, but due to photobleaching and destructive fluorescence by-products, it is best to minimize fluorescence exposure for photosensitive specimens and live cells. This exposure problem could be completely avoided by using phase-contrast microscopy, implemented through the same optics as fluorescence microscopy. The purpose of this work was to evaluate functions for both phase-contrast and fluorescence autofocus and determine the suitability of phase-contrast autofocus for fluorescence microscopy. Eleven autofocus functions were independently evaluated for fluorescence and phase-contrast microscopy. The most suitable functions were then chosen from these and phase-contrast and fluorescence autofocus were compared on scans each comprising more than 1,000 microscope fields. Autofocus standard deviation (S.D.) of better than 100 nm was achieved for both phase contrast and fluorescence. There was a measurable difference between the best focus positions in the two modes, but the difference was constant enough to be measured and corrected, suggesting the possibility of using phase contrast to predict best focus in fluorescence microscopy. The scanning experiments also showed that autofocus can be performed at least as fast as 0.25 s/field without loss of precision.

3T3 Cells↗

Dynamic concentration challenges for biosensor characterization.

A method and apparatus are described for characterization of the steady state and dynamic response of biosensors. The apparatus produces a steady stream of homogeneously mixed analyte whose concentration can be fixed at discrete values or varied continuously. The device is ideally suited for continuously operated biosensors, but is also effective for biosensors that operate in discrete sampling modes. The system permits simultaneous testing of several sensors and determination of the accuracy, precision and repeatability of sensor response. The characteristics of this testing apparatus were validated with ferrocyanide and glucose as indicators. As an example of use of the apparatus, concentration ramps were created and used to complement conventional step changes for characterizing an implantable glucose sensor. The ramp rate can be adjusted easily by scaling the apparatus to simulate the rate of concentration change anticipated during actual monitoring situations.

Animals↗

Design and validation of the transparent oxygen sensor array.

A new oxygen monitoring system has been developed that consists of an array of transparent, independently-connected oxygen sensors mounted on a glass plate. This system is intended for continuous monitoring of oxygen at multiple locations on the surface of exteriorized tissues, while simultaneously visualizing microvascular activity. The sensor array is fabricated by techniques similar to those employed for semiconductors, which facilitate customization of sensor size and pattern to best monitor oxygen in a given physiologic preparation. Methods are described for characterizing the performance of the sensor array in vitro, including studies on the oxygen sensitivity, stability of the signal, and detection of oxygen gradients. An example of in vivo application of the sensor array is also presented.

Animals↗

Application of chronic intravascular blood glucose sensor in dogs.

An intravenous glucose sensor was implanted in six dogs for 1-15 wk. The glucose sensor is a flexible cylinder, approximately 0.2 cm diam and 30 cm long, with a tip containing immobilized glucose oxidase and catalase coupled to a potentiostatic O2 sensor. The sensor and a similar O2 reference sensor were implanted in the superior vena cava near the entrance of the right atrium. The sensor response was conveyed externally either by a telemetry system implanted nearby, surgically accessed leads, or chronically maintained percutaneous leads. Summing over the six implants, there was a total implantation period of 333 days during which glucose sensors were functional on demand. The sensor response showed agreement with conventionally assayed blood samples after accounting for a response lag. Sensor response to glucose showed little change over the implant period. Biocompatibility, enzyme lifetime, O2 availability, O2 sensor stability, and biochemical interference were not limitations. Results demonstrated that this sensor can function effectively as an implant in dogs for a period of months and has the potential for long-term operation.

Animals↗

Physiological preparation for studying the response of subcutaneously implanted glucose and oxygen sensors.

A physiological preparation has been developed for studying the response of glucose end oxygen sensors chronically implanted in subcutaneous tissues. The preparation employs a chamber permanently mounted on the back of a rat that supports the growth of vascularized subcutaneous tissue around the sensors and is used in conjunction with chronic intravascular catheters for blood sampling and fluid infusion. A total of 26 glucose and oxygen sensors were implanted in nine chambers. At 10 days, the tissue surrounding the sensors was cellular, well vascularized and permeable. Glucose sensors responded to glucose infusions with a 10-15 minute lag.

Animals↗