PubMed Health⌕ Search

Biomedical subjects

D A Steinman

Publications and source records attributed to D A Steinman.

At least 19 recordsLinked to original sources

Effect of black blood MR image quality on vessel wall segmentation.

Black blood MRI has become a popular technique for measuring arterial wall area as an indicator of plaque size. Computer-assisted techniques for segmenting vessel boundaries have been developed to increase measurement precision. In this study, the carotid arteries of four normal subjects were imaged at seven different fields of view (FOVs), keeping all other imaging parameters fixed, to determine whether spatial resolution could be increased at the expense of image quality without sacrificing precision. Wall areas were measured via computer-assisted segmentation of the vessel boundaries performed repeatedly by two operators. Analysis of variance (ANOVA) demonstrated that the variability of wall area measurements was below 1.5 mm(2) for in-plane spatial resolutions between 0.22 mm and 0.37 mm. An inverse relationship between operator variability and the signal difference-to-noise ratio (SDNR) demonstrated that semi-automatic segmentation of the wall boundaries was robust for SDNR >3, defining a criterion above which subjective image quality can be degraded without an appreciable loss of information content. Our study also suggested that spatial resolutions higher than 0.3 mm may be required to quantify normal wall areas to within 10% accuracy, but that the reduced SNR associated with the higher resolution may be tolerated by semi-automated wall segmentation without an appreciable loss of precision.

Adult↗

Effect of distal graft anastomosis site on retrograde perfusion and flow patterns of native coronary vasculature.

BACKGROUND: To select the site of a target vessel for distal anastomosis surgeons use different approaches. Some try to place the graft as close to the stenosis as possible, whereas others routinely anastomose the graft onto the distal portion. In this latter case the proximal portion and its tributaries are perfused from the graft in a retrograde rather than an antegrade fashion. The aim of this study was to investigate the effect of local hemodynamics associated with the different location of distal anastomoses on flow patterns in the proximal native artery and its branches. METHODS: Computational fluid dynamic and in vitro model studies were carried out in a control model composed of a straight tube (host) with a 45E side branch and models in which the proximal end of the host had various degrees of stenosis; a 45E end-to-side "graft" anastomosis was introduced either proximal (upstream) or distal (downstream) to the branch. RESULTS: Placing the graft proximal to the branch largely preserved the flow patterns that were seen in the control model. Placing the graft distal to the branch, however, introduced an extensive region of relatively stagnant flow in the native vessel near the branch. Such regions are known to promote thrombus formation that could ultimately lead to occlusion of the retrograde portion of the host vessel. CONCLUSIONS: This study suggests that, although often less convenient surgically, long-term outcome of coronary artery bypass grafting may be improved by placing grafts in the most proximal portion of the native vessel, as close to the occlusion or stenosis as possible for better preservation of a proximal artery and its branches.

Blood Flow Velocity↗

A semi-automatic technique for measurement of arterial wall from black blood MRI.

Black blood magnetic resonance imaging (MRI) has become a popular technique for imaging the artery wall in vivo. Its noninvasiveness and high resolution make it ideal for studying the progression of early atherosclerosis in normal volunteers or asymptomatic patients with mild disease. However, the operator variability inherent in the manual measurement of vessel wall area from MR images hinders the reliable detection of relatively small changes in the artery wall over time. In this paper we present a semi-automatic method for segmenting the inner and outer boundary of the artery wall, and evaluate its operator variability using analysis of variance (ANOVA). In our approach, a discrete dynamic contour is approximately initialized by an operator, deformed to the inner boundary, dilated, and then deformed to the outer boundary. A group of four operators performed repeated measurements on 12 images from normal human subjects using both our semiautomatic technique and a manual approach. Results from the ANOVA indicate that the inter-operator standard error of measurement (SEM) of total wall area decreased from 3.254 mm2 (manual) to 1.293 mm2 (semi-automatic), and the intra-operator SEM decreased from 3.005 mm2 to 0.958 mm2. Operator reliability coefficients increased from less than 69% to more than 91% (inter-operator) and 95% (intra-operator). The minimum detectable change in wall area improved from more than 8.32 mm2 (intra-operator, manual) to less than 3.59 mm2 (inter-operator, semi-automatic), suggesting that it is better to have multiple operators measure wall area with our semi-automatic technique than to have a single operator make repeated measurements manually. Similar improvements in wall thickness and lumen radius measurements were also recorded. Since the semi-automatic technique has effectively ruled out the effect of the operator on these measurements, it may be possible to use such techniques to expand prospective studies of atherogenesis to multiple centers so as to increase access to real patient data without sacrificing reliability.

Adult↗

Simulated pathline visualization of computed periodic blood flow patterns.

Improvements in computer hardware and software have made it possible to model pulsatile blood flow in realistic arterial geometries. Such studies produce enormous amounts of velocity data, which are often difficult to interpret and communicate using traditional contour and/or vector field plots. Inspired by in vitro flow visualization techniques such as particle image velocimetry (PIV), we describe a simple and effective method for visualizing periodic three-dimensional velocity data, based on the subdivision and sequential display of computed particle trajectories. Analogous to a PIV experiment, the length and spacing of such simulated particle pathlines are controlled by user-specified shutter-speed and frame rate variables. Strategies for color-coding pathlines to highlight important hemodynamic features such as recirculation zones and branch flow division are presented.

Biomechanical Phenomena↗

Flow patterns at the stenosed carotid bifurcation: effect of concentric versus eccentric stenosis.

Carotid stenosis severity is a commonly used indicator for assessing risk of stroke. However, the majority of individuals with severe carotid artery disease never suffer a stroke, and strokes can occur even with only mild or moderate stenosis. This suggests local factors (other than stenosis severity) at or near the carotid artery bifurcation may be important in determining stroke risk. In this paper we investigate the effect of stenosis geometry on flow patterns in the stenosed carotid bifurcation, using concentrically and eccentrically stenosed anthropomorphic carotid bifurcation models having identical stenosis severity. Computational simulations and experimental flow visualizations both demonstrate marked differences in flow patterns of concentric and eccentric stenosis models for moderately and severely stenosed cases, respectively. In particular, we identify post-stenotic recirculation zone size and location, and spatial extent of elevated wall shear stress as key factors differing between the two geometries. As these are also rotid plaque more vulnerable to cerebral embolus prokey biophysical factors promoting thrombogenesis, we propose that the stenosed carotid bifurcation geometry--or the induced flow patterns themselves--may provide more specific indicators for those plaques that are vulnerable to enhanced thromboembolic potential, and hence, increased risk of ischemic stroke.

Biomedical Engineering↗

Rapid three-dimensional segmentation of the carotid bifurcation from serial MR images.

The current trend in computational hemodynamics is to employ realistic models derived from ex vivo or in vivo imaging. Such studies typically produce a series of images from which the lumen boundaries must first be individually extracted (i.e., two-dimensional segmentation), and then serially reconstructed to produce the three-dimensional lumen surface geometry. In this paper, we present a rapid three-dimensional segmentation technique that combines these two steps, based on the idea of an expanding virtual balloon. This three-dimensional technique is demonstrated in application to finite element meshing and CFD modeling of flow in the carotid bifurcation of a normal volunteer imaged with black blood MRI. Wall shear stress patterns computed using a mesh generated with the three-dimensional technique agree well with those computed using a mesh generated from conventional two-dimensional segmentation and serial reconstruction. In addition to reducing the time required to extract the lumen surface from hours to minutes, our approach is easy to learn and use and requires minimal user intervention, which can potentially increase the accuracy and precision of quantitative and longitudinal studies of hemodynamics and vascular disease.

Carotid Arteries↗

Prostate boundary segmentation from 2D ultrasound images.

Outlining, or segmenting, the prostate is a very important task in the assignment of appropriate therapy and dose for cancer treatment; however, manual outlining is tedious and time-consuming. In this paper, an algorithm is described for semiautomatic segmentation of the prostate from 2D ultrasound images. The algorithm uses model-based initialization and the efficient discrete dynamic contour. Initialization requires the user to select only four points from which the outline of the prostate is estimated using cubic interpolation functions and shape information. The estimated contour is then deformed automatically to better fit the image. The algorithm can easily segment a wide range of prostate images, and contour editing tools are included to handle more difficult cases. The performance of the algorithm with a single user was compared to manual outlining by a single expert observer. The average distance between semiautomatically and manually outlined boundaries was found to be less than 5 pixels (0.63 mm), and the accuracy and sensitivity to area measurements were both over 90%.

Algorithms↗

Accuracy and variability assessment of a semiautomatic technique for segmentation of the carotid arteries from three-dimensional ultrasound images.

In this paper, we report on a semiautomatic method for segmentation of three-dimensional (3D) carotid vascular ultrasound (US) images. Our method is based on a dynamic balloon model represented by a triangulated mesh. The mesh is manually placed within the interior of the carotid vessels, then is driven outward until it reaches the vessel wall by applying an inflation force to the mesh. Once the mesh is in close proximity to the vessel wall, it is further deformed using an image-based force, in order to better localize the boundary. Since the method requires manual initialization, there is inherent variability in the position and shape of the final segmented boundary. Using a 3D US image of a patient's carotids, we have examined the local variability in boundary position as the initialization position is varied throughout the interior of the carotid vessels in the 3D image. We have compared the semiautomatic segmentation method to a fully manual segmentation method, and found that the semiautomatic approach is less variable than the intraobserver variability for manual segmentation. We have furthermore examined the accuracy of the semiautomatic method by comparing the average surface to an "ideal" surface, determined by the average manually segmented surface. We have found, in general, good agreement between the semiautomatic and manual segmentation methods. For the 3D US image in question, the mean separation between the average segmented surface and the gold standard was found to be 0.35 mm. The two surfaces were determined to agree with each other, within uncertainty, at 65% of the mesh points comprising the two surfaces.

Biophysical Phenomena↗

Effect of contralateral carotid artery stenosis on carotid ultrasound velocity measurements.

BACKGROUND AND PURPOSE: Carotid ultrasonography is being increasingly performed as the sole investigation to assess internal carotid artery (ICA) stenosis. A potential source of error in using ultrasound peak systolic velocity (PSV) measurements is that the redistribution of blood flow due to severe stenosis in a contralateral carotid artery may lead to artificially elevated values. METHODS: Ultrasonography was performed before and after carotid endarterectomy in symptomatic patients who participated in the North American Symptomatic Carotid Endarterectomy Trial (NASCET). The mean change in PSV in the unoperated artery was assessed across all degrees of angiographically defined stenosis. A simple theoretical resistance model of the cerebral circulation was also derived. RESULTS: Complete bilateral ultrasound examinations were performed within 90 days of the initial scan in 386 patients. In the presence of a contralateral severe (70% to 99%) ICA stenosis, the PSV in the unoperated artery was artificially elevated by a mean of 84 cm/s (P:=0.03; 95% CI, 10 to 159 cm/s). The mean elevation was less pronounced for lesser degrees of stenosis (11 to 21 cm/s). Small elevations (3 to 12 cm/s) were observed when the contralateral artery had <70% stenosis. The patterns of observed results were congruent with those from the theoretical model. CONCLUSIONS: The present study showed that a severely stenosed contralateral ICA can artificially elevate ultrasound PSV. Since the effect was greatest when bilaterally severe stenoses were present, caution must be exercised when assessing the degree of ICA stenosis on the basis of ultrasonography PSV measurements alone.

Aged↗

Characterization of common carotid artery blood-flow waveforms in normal human subjects.

Knowledge of human blood-flow waveforms is required for in vitro investigations and numerical modelling. Parameters of interest include: velocity and flow waveform shapes, inter- and intra-subject variability and frequency content. We characterized the blood-velocity waveforms in the left and right common carotid arteries (CCAs) of 17 normal volunteers (24 to 34 years), analysing 3560 cardiac cycles in total. Instantaneous peak-velocity (Vpeak) measurements were obtained using pulsed-Doppler ultrasound with simultaneous collection of ECG data. An archetypal Vpeak waveform was created using velocity and timing parameters at waveform feature points. We report the following timing (post-R-wave) and peak-velocity parameters: cardiac interbeat interval (T(RR)) = 0.917 s (intra-subject standard deviation = +/- 0.045 s); cycle-averaged peak-velocity (V(CYC)) = 38.8 cm s(-1) (+/-1.5 cm s(-1)); maximum systolic Vpeak = 108.2 cm s(-1) (+/-3.8 cm s(-1)) at 0.152 s (+/-0.008 s); dicrotic notch Vpeak = 19.4 cm s(-1) (+/-2.9 cm s(-1)) at 0.398 s (+/-0.007 s). Frequency components below 12 Hz constituted 95% of the amplitude spectrum. Flow waveforms were computed from Vpeak by analytical solution of Womersley flow conditions (derived mean flow = 6.0 ml s(-1)). We propose that realistic, pseudo-random flow waveform sequences can be generated for experimental studies by varying, from cycle to cycle, only T(RR) and V(CYC) of a single archetypal waveform.

Adult↗

A numerical study of blood flow patterns in anatomically realistic and simplified end-to-side anastomoses.

PURPOSE: Recently, some numerical and experimental studies of blood flow in large arteries have attempted to accurately replicate in vivo arterial geometries, while others have utilized simplified models. The objective of this study was to determine how much an anatomically realistic geometry can be simplified without the loss of significant hemodynamic information. METHOD: A human femoral-popliteal bypass graft was used to reconstruct an anatomically faithful finite element model of an end-to-side anastomosis. Nonideal geometric features of the model were removed in sequential steps to produce a series of successively simplified models. Blood flow patterns were numerically computed for each geometry, and the flow and wall shear stress fields were analyzed to determine the significance of each level of geometric simplification. RESULTS: The removal of small local surface features and out-of-plane curvature did not significantly change the flow and wall shear stress distributions in the end-to-side anastomosis. Local changes in arterial caliber played a more significant role, depending upon the location and extent of the change. The graft-to-host artery diameter ratio was found to be a strong determinant of wall shear stress patterns in regions that are typically associated with disease processes. CONCLUSIONS: For the specific case of an end-to-side anastomosis, simplified models provide sufficient information for comparing hemodynamics with qualitative or averaged disease locations, provided the "primary" geometric features are well replicated. The ratio of the graft-to-host artery diameter was shown to be the most important geometric feature. "Secondary" geometric features such as local arterial caliber changes, out-of-plane curvature, and small-scale surface topology are less important determinants of the wall shear stress patterns. However, if patient-specific disease information is available for the same arterial geometry, accurate replication of both primary and secondary geometric features is likely required.

Anastomosis, Surgical↗

On the nature and reduction of plaque-mimicking flow artifacts in black blood MRI of the carotid bifurcation.

Cardiac-gated black blood MRI of the carotid artery bifurcation in normal human subjects shows signal within the lumen suggesting wall thickening or atherosclerotic plaque. This signal was believed to be artifactual, arising from complex flow patterns present at the carotid bifurcation. Computer simulation of the hemodynamics and black blood multislice image acquisition in a model of the carotid bifurcation showed that these artifacts arise from spins recovering their signal within the slow, recirculating flow of the carotid bulb. The computed hemodynamics also suggested that these artifacts could be minimized or eliminated entirely by gating the acquisition of slices in the most artifact-prone region of the carotid bulb within a 250-ms window after peak systole. Application of these predictions to studies of normal volunteers showed that, in most cases, these flow artifacts in black blood MRI can be eliminated simply by altering the phase of the cardiac cycle to which the image acquisition is gated. The observation that the size and placement of the saturation slabs had little effect on these artifacts suggested that, in those cases in which recirculation persists throughout the cardiac cycle, either inversion-recovery or presaturation within the bulb itself would be required to suppress them.

Adult↗

Computational blood flow modelling: errors associated with reconstructing finite element models from magnetic resonance images.

Construction of computational blood flow models from magnetic resonance (MR) scans of real arteries is a powerful tool for studying arterial hemodynamics. In this report we experimentally determine a lower bound for errors associated with such an approach, and present techniques for minimizing such errors. A known, simple three-dimensional geometry (cylindrical tube) was imaged using a commercial MR scanner, and the resulting images were used to construct finite element flow models. Computed wall-shear stresses were compared to known values and peak errors of 40-60% were found. These errors can be attributed to limited spatial resolution, image segmentation and model construction. A simple smoothing technique markedly reduced these peak errors. We conclude that smoothing is required in the construction of arterial models from in vivo MR images. If used appropriately, such images can be used to construct acceptably accurate computational models of realistic arterial geometries.

Blood Circulation↗

Flow waveform effects on end-to-side anastomotic flow patterns.

PURPOSE: Restenosis due to distal anastomotic intimal hyperplasia, a leading cause of arterial bypass graft failure, is thought to be promoted by hemodynamic effects, specifically 'abnormal' wall shear stress patterns. The purpose of this study was to quantify the effects of flow waveform on peri-anastomotic flow and wall shear stress patterns. METHODS: Blood flow and wall shear stress patterns were numerically computed in a representative three-dimensional anastomosis using femoral, iliac and coronary flow waveforms suitable for humans at rest. Numerical results were validated against experimental data. RESULTS: Peri-anastomotic wall shear stress patterns were influenced by a complex interplay between secondary flow effects and unsteadiness. Peripheral flow waveforms (iliac, femoral) produced large temporal and spatial wall shear stress gradients on the host artery bed. In comparison, the coronary flow waveform produced normalized bed wall shear stress gradients that were a factor of 2-3 less than for the peripheral waveforms, even though average bed wall shear stress magnitudes were similar for the two waveforms. CONCLUSIONS: If anastomotic intimal hyperplasia is promoted by large spatial and/or temporal gradients of wall shear stress, as has been proposed, this study predicts that there will be markedly less intimal hyperplasia on the host artery bed of coronary bypass grafts than for peripheral bypass grafts. This information, in conjunction with a comparative histopathologic study of intimal hyperplasia distribution, could help determine specific wall shear stress factors promoting intimal hyperplasia.

Anastomosis, Surgical↗

Hemodynamics of human carotid artery bifurcations: computational studies with models reconstructed from magnetic resonance imaging of normal subjects.

PURPOSE: The precise role played by hemodynamics, particularly wall shear stress, in the development and progression of vascular disease remains unclear, in large part because of a lack of in vivo studies with humans. Although technical challenges remain for noninvasively imaging wall shear stresses in humans, vascular anatomy can be imaged with sufficiently high resolution to allow reconstruction of three-dimensional models for computational hemodynamic studies. In this paper we present an entirely noninvasive magnetic resonance imaging (MRI) protocol that provides carotid bifurcation geometry and flow rates from which the in vivo hemodynamics can be computed. Maps of average, oscillatory, and gradients of wall shear stress are presented for two normal human subjects, and their data are compared with those computed for an idealized carotid bifurcation model. METHODS: An MRI protocol was developed to acquire all necessary image data in scan times suitable for patient studies. Three-dimensional models of the carotid bifurcation lumen were reconstructed from serial black blood MR images of two normal volunteers. Common and internal carotid artery flow rate waveforms were determined from MRI phase-contrast velocity imaging in the same subjects and were used to impose fully developed velocity boundary conditions for the computational model. Subject-specific time-resolved velocities and wall shear stresses were then computed with a finite element-based Navier-Stokes equation solver. RESULTS: Models reconstructed from in vivo MRI of two subjects showed obvious differences in branch angle, bulb size and extent, and three-dimensional curvature. Maps of a variety of wall shear stress indices showed obvious qualitative differences in patterns between the in vivo models and between the in vivo models and the idealized model. Secondary, helical flow patterns, induced primarily by the asymmetric and curved in vivo geometries, were found to play a key role in determining the resulting wall shear stress patterns. The use of in vivo flow rate waveforms was found to play a minor but noticeable role in some of the wall shear stress behavior observed. CONCLUSIONS: Conventional "averaged" carotid bifurcation models mask interesting hemodynamic features observed in realistic models derived from noninvasive imaging of normal human subjects. Observation of intersubject variations in the in vivo wall shear stress patterns supports the notion that more conclusive evidence regarding the role of hemodynamics in vascular disease may be derived from such individual studies. The techniques presented here, when combined with subject-specific MRI measurements of carotid artery plaque thickness and composition, provide the tools necessary for entirely noninvasive, prospective, in vivo human studies of hemodynamics and the relationship of hemodynamics to vascular disease.

Adult↗

MR measurement and numerical simulation of steady flow in an end-to-side anastomosis model.

Magnetic resonance phase contrast velocity imaging ('MR PC velocimetry') is a powerful tool for measuring blood velocity. While it has been demonstrated that MR PC velocimetry can accurately measure velocity profiles in simple, unidirectional flows, errors can arise when measuring the more complex, multidirectional flows of clinical importance. In this work, we have compared MR PC velocity measurements with numerical simulations of steady flow in a physiologically relevant model of an end-to-side anastomosis, which produces many of the complex flow features expected in vivo. MR PC velocity profiles, measured using both 2D and 3D pulse sequences, showed very good agreement with numerically computed profiles, although at 2D PC data showed slightly larger errors than the 3D PC data in regions of high accelerations and oblique flow, likely due to displacement artifacts. We conclude that, under ideal conditions, MR phase contrast velocimetry can measure complex flow patterns to within 15% accuracy, but that care should be taken when using 2D pulse sequences to measure such complex flows.

Anastomosis, Surgical↗

Particle volumetric residence time calculations in arterial geometries.

The quantification of particle (platelet) residence times in arterial geometries is relevant to the pathogenesis of several arterial diseases. In this manuscript, the concept of "volumetric residence time" (VRT) is introduced. The VRT takes into account where particles accumulate and how long they remain there, and is well-suited to characterizing particle distributions in the complex geometries typical of the cardiovascular system. A technique for the calculation of volumetric residence time is described, which assumes that platelets are neutrally buoyant passive tracer particles, and which tracks small Lagrangian fluid elements containing a uniform concentration of platelets. This approach is used to quantify particle (platelet) residence times in the region of a modeled stenosis with a 45 percent area reduction. Residence time distributions are computed for a representative population of platelets, and for a subpopulation assumed to be "activated" by exposure to shear stresses above a threshold value. For activated platelets, high particle residence times were observed just distal to the apex of the stenosis throat, which can be explained by the presence of high shear stresses and low velocities in the throat immediately adjacent to the vessel wall. Interestingly, the separation zone distal to the stenosis showed only modestly elevated residence times, due to its highly mobile and transient nature. This calculation demonstrates the utility of the VRT concept for cardiovascular studies, particularly if a subpopulation of all particles is to be tracked. We conclude that the volumetric residence time is a useful tool.

Algorithms↗

The effect of wall distensibility on flow in a two-dimensional end-to-side anastomosis.

The development of intimal hyperplasia at the distal anastomosis is the major cause of long-term bypass graft failure. To evaluate the suspected role of hemodynamic factors in the pathogenesis of distal intimal hyperplasia, an understanding of anastomotic flow patterns is essential. Due to the complexity of arterial flow, model studies typically make simplifying assumptions, such as treating the artery and graft walls as rigid. In the present study this restriction is relaxed to consider the effects of vessel wall distensibility on anastomotic flow patterns. Flow was simulated in an idealized 2-D distensible end-to-side anastomosis model, using parameters appropriate for the distal circulation and assuming a purely elastic artery wall. A novel numerical approach was developed in which the wall velocities are solved simultaneously with the fluid and pressure fields, while the wall displacements are treated via an iterative update. Both the rigid and distensible cases indicated the presence of elevated temporal variations and low average magnitudes of wall shear stress at sites known to be susceptible to the development of intimal hyperplasia. At these same sites, large spatial gradients of wall shear stress were also noted. Comparison between distensible-walled and corresponding rigid-walled simulations showed moderate changes in wall shear stress at isolated locations, primarily the bed, toe and heel. For example, in the case of a distensible geometry and a physiologic pressure waveform, the heel experienced a 38 percent increase in cycle-averaged shear stress, with a corresponding 15 percent reduction in shear stress variability, both relative to the corresponding values in the rigid-walled case.(ABSTRACT TRUNCATED AT 250 WORDS)

Anastomosis, Surgical↗