Computational blood flow modelling: errors associated with reconstructing finite element models from magnetic resonance images.

Abstract

Construction of computational blood flow models from magnetic resonance (MR) scans of real arteries is a powerful tool for studying arterial hemodynamics. In this report we experimentally determine a lower bound for errors associated with such an approach, and present techniques for minimizing such errors. A known, simple three-dimensional geometry (cylindrical tube) was imaged using a commercial MR scanner, and the resulting images were used to construct finite element flow models. Computed wall-shear stresses were compared to known values and peak errors of 40-60% were found. These errors can be attributed to limited spatial resolution, image segmentation and model construction. A simple smoothing technique markedly reduced these peak errors. We conclude that smoothing is required in the construction of arterial models from in vivo MR images. If used appropriately, such images can be used to construct acceptably accurate computational models of realistic arterial geometries.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Moore, D A Steinman, C R Ethier. 1998. Computational blood flow modelling: errors associated with reconstructing finite element models from magnetic resonance images.. https://doi.org/10.1016/s0021-9290(97)00125-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Randomized trial of dobutamine versus dopamine in preterm infants with low systemic blood flow.

OBJECTIVE: Our purpose was to determine if dobutamine or dopamine results in greater improvements in systemic blood flow in very preterm infants with low flow during the first 24 hours of life. STUDY DESIGN: A 2-center, randomized, double-blind study. Infants (n = 42) with low superior vena cava (SVC) flow (<41 mL/kg/min) in the first 12 hours were randomly assigned to receive 10 mL/kg normal saline solution, followed by 10 microg/kg/minute of dobutamine or dopamine. If low flow persisted or recurred, the inotrope was increased to 20 microg/kg/minute, with crossover to the other inotrope if treatment failed to maintain flow. RESULTS: Volume produced a more significant increase in SVC flow than dopamine (+43%). At the highest dose, dobutamine resulted in a significantly greater increase in SVC flow than dopamine (mean, +9.9 vs -3.2 mL/kg/min, P =.02). Dopamine resulted in a significantly greater increase in blood pressure. Infants receiving dobutamine only at 24 hours had a greater right ventricular output than infants receiving dopamine (mean, 295 vs 167 mL/kg/min, P <.001). Forty percent failed to increase or maintain SVC flow in response to either inotrope. No significant differences in mortality or morbidity were found. CONCLUSIONS: Dobutamine produced a greater increase in blood flow than dopamine.

Blood Circulation↗

RANTES and MIP-1beta mRNA expression in human peripheral blood mononuclear cells: transcript quantification using NASBA technology.

The importance of chemokines in the immune response, as well as in a range of specific disease states, is becoming increasingly apparent. The role of CC- (or beta-) chemokines and their receptors in the pathology and mechanisms of HIV-1 infection has served to intensify interest in these factors. Although the functionality of these factors resides in their protein forms, assays for the detection and quantification of these protein factors in clinical samples are not readily available. Consequently, we designed NASBA-based assays for the quantification of the mRNA encoding two members of the CC-chemokine family: RANTES and MIP-1beta. The NASBA-based assays are extremely sensitive, accurate, and reproducible across a dynamic range of at least four orders of magnitude. Inter-assay performance is comparable to intra-assay performance. We applied these methods to the analysis of normal human PBMC and PBMC from HIV-1 infected individuals. Although MIP-1beta mRNA levels are higher than RANTES levels in both populations, RANTES levels in HIV-1+ patients are higher than in normal individuals. The utility of these assays in longitudinal studies of specific subpopulations of cells, as well as their potential use in clinical diagnostics, is discussed.

Blood Circulation↗