Computerized mass detection for digital breast tomosynthesis directly from the projection images.

Digital breast tomosynthesis (DBT) has recently emerged as a new and promising three-dimensional modality in breast imaging. In DBT, the breast volume is reconstructed from 11 projection images, taken at source angles equally spaced over an arc of 50 degrees. Reconstruction algorithms for this modality are not fully optimized yet. Because computerized lesion detection in the reconstructed breast volume will be affected by the reconstruction technique, we are developing a novel mass detection algorithm that operates instead on the set of raw projection images. Mass detection is done in three stages. First, lesion candidates are obtained for each projection image separately, using a mass detection algorithm that was initially developed for screen-film mammography. Second, the locations of a lesion candidate are backprojected into the breast volume. In this feature volume, voxel intensities are a combined measure of detection frequency (e.g., the number of projections in which a given lesion candidate was detected), and a measure of the angular range over which a given lesion was detected. Third, features are extracted after reprojecting the three-dimensional (3-D) locations of lesion candidates into projection images. Features are combined using linear discriminant analysis. The database used to test the algorithm consisted of 21 mass cases (13 malignant, 8 benign) and 15 cases without mass lesions. Based on this database, the algorithm yielded a sensitivity of 90% at 1.5 false positives per breast volume. Algorithm performance is positively biased because this dataset was used for development, training, and testing, and because the number of algorithm parameters was approximately the same as the number.of patient cases. Our results indicate that computerized mass detection in the sequence of projection images for DBT may be effective despite the higher noise level in those images.

Algorithms↗

Computerized detection of mass lesions in digital breast tomosynthesis images using two- and three dimensional radial gradient index segmentation.

Initial results for a computerized mass lesion detection scheme for digital breast tomosynthesis (DBT) images are presented. The algorithm uses a radial gradient index feature for the initial lesion detection and for segmentation of lesion candidates. A set of features is extracted for each segmented partition. Performance of two- and three dimensional features was compared. For gradient features, the additional dimension provided no improvement in classification performance. For shape features, classification using 3D features was improved compared to the 2D equivalent features. The preliminary overall performance was 76% sensitivity at 11 false positives per exam, estimated based on DBT image data of 21 masses. A larger database will allow for further development and improvement in our computer aided detection scheme.

Breast Neoplasms↗

Double reading.

Clearly, the cost of double reading varies with the approach used. The Massachusetts General Hospital method can only lead to an increase in recalls and the costs that these engender (anxiety for the women recalled, trauma from any biopsies obtained, and the actual monetary costs of additional imaging and interventions). It is of interest that one potential cost, the concern that women recalled may be reluctant to participate again in screening, does not seem to be the case. Women who are recalled appear to be more likely to participate in future screening. Double interpretation where there must be a consensus between the interpreting radiologists, and if this cannot be reached a third arbiter, is the most labor intensive, but can reduce the number of recalls in a double reading system. Computer systems have been developed to act as a second reader. The films must be digitized and then fed through the reader, but studies suggest that the computer can identify cancers that may be overlooked by a human reader. The challenge is to do this without too many false-positive calls. If the radiologist finds the false-positives are too numerous and distracting, then the system is not used. As digital mammographic systems proliferate, and computer algorithms become more sophisticated, the second human reader will likely be replaced by a computer-aided detection system and double reading will become the norm.

Algorithms↗

Potential contribution of computer-aided detection to the sensitivity of screening mammography.

PURPOSE: To determine the false-negative rate in screening mammography, the capability of computer-aided detection (CAD) to identify these missed lesions, and whether or not CAD increases the radiologists' recall rate. MATERIALS AND METHODS: All available screening mammograms that led to the detection of biopsy-proved cancer (n = 1,083) and the most recent corresponding prior mammograms (n = 427) were collected from 13 facilities. Panels of radiologists evaluated the retrospectively visible prior mammograms by means of blinded review. All mammograms were analyzed by a CAD system that marks features associated with cancer. The recall rates of 14 radiologists were prospectively measured before and after installation of the CAD system. RESULTS: At retrospective review, 67% (286 of 427) of screening mammography-detected breast cancers were visible on the prior mammograms. At independent, blinded review by panels of radiologists, 27% (115 of 427) were interpreted as warranting recall on the basis of a statistical evaluation index; and the CAD system correctly marked 77% (89 of 115) of these cases. The original attending radiologists' sensitivity was 79% (427 of [427 + 115]). There was no statistically significant increase in the radiologists' recall rate when comparing the values before (8.3%) with those after (7.6%) installation of the CAD system. CONCLUSION: The original attending radiologists had a false-negative rate of 21% (115 of [427 + 115]). CAD prompting could have potentially helped reduce this false-negative rate by 77% (89 of 115) without an increase in the recall rate.

Adult↗

Breast cancer: computer simulation method for estimating optimal intervals for screening.

PURPOSE: To develop and evaluate a mathematic method that can be used to determine the optimal screening interval for detection of breast cancer prior to distant metastatic spread. MATERIALS AND METHODS: A computer simulation was developed with the use of biologically based data from the literature on the rates of tumor growth and spread, which can be used to calculate the course of breast cancer growth and metastasis. RESULTS: On the basis of the data available at this time, the results of the simulations suggested that a screening interval of 2 years would result in a 22% reduction in the rate of distant metastatic disease, an interval of 1 year would result in a 51% reduction, and an interval of 6 months would result in an 80% reduction. CONCLUSION: These findings suggest that more frequent screening could dramatically reduce the death rate from breast cancer.

Appointments and Schedules↗

Previous breast biopsy for benign disease rarely complicates or alters interpretation on screening mammography.

OBJECTIVE: It has been suggested that breast screening leads to too many biopsies for benign disease that permanently scar the breast and confuse the interpretation of subsequent mammograms. We undertook retrospective and prospective studies to determine how often an excisional biopsy for benign breast disease complicates or alters interpretation of screening mammograms. MATERIALS AND METHODS: Retrospective review of our screening center database yielded 31,025 asymptomatic patients who had routine mammographic screening studies between 1993 and 1996. Of the 58,538 examinations of these patients, 53,510 were of patients who had no history of breast biopsy and 5028 were of patients who had a history of breast biopsy for benign disease. Recall rates were compared between the two groups. In the prospective study, radiologists reviewed the mammograms of 1997 consecutive patients presenting to the screening center, 173 of whom reported a prior breast biopsy for benign disease. The radiologist interpreting the images determined how often evidence of the biopsy site was apparent on the mammogram and how often such changes necessitated additional imaging. RESULTS: In the retrospective study, 3296 (6%) of the 53,510 studies done in patients who did not have a biopsy for benign disease and 360 (7%) of the 5028 studies done in women who had a biopsy for benign disease led to additional imaging. Eight recalls for further imaging (0.16%) among the 5028 studies in women with a prior biopsy for benign disease were related to the biopsy site. In the prospective study, 24 (14%) of the 173 women who had a biopsy for benign disease had mammographic evidence of the biopsy site. Nine (5%) of the 173 women who had previously had a biopsy for benign disease and 86 (5%) of the 1824 patients without a prior biopsy were recalled for additional imaging. No women were recalled because a previous breast biopsy for benign disease led to confusion or diagnostic concern. CONCLUSION: Changes in patients' breasts due to previous excisional biopsies for benign breast disease rarely pose a diagnostic dilemma in the interpretation of routine screening mammograms.

Biopsy↗