PubMed Health⌕ Search

Biomedical subjects

D B Vigneron

Publications and source records attributed to D B Vigneron.

At least 55 records · Page 3Linked to original sources

Detection of locally recurrent prostate cancer after cryosurgery: evaluation by transrectal ultrasound, magnetic resonance imaging, and three-dimensional proton magnetic resonance spectroscopy.

OBJECTIVES: To assess and compare the clinical usefulness of transrectal ultrasound (TRUS), magnetic resonance imaging (MRI), and three-dimensional proton magnetic resonance spectroscopic imaging (3-D MRSI) in detecting local recurrence of carcinoma of the prostate (CaP) in patients with detectable prostate-specific antigen (PSA) levels after cryosurgery. METHODS: In a prospective study, 25 patients who had undergone cryosurgery as primary treatment for CaP underwent endorectal MRI and 3-D MRSI, followed by TRUS-guided prostate biopsy. At the time of study, 20 patients had detectable PSA; the remaining 5 patients served as controls. All patients had random sextant and guided prostate biopsy for correlation with imaging and MR spectroscopic findings. RESULTS: In patients with detectable PSA, MRSI identified, location-for-location, all foci of CaP and benign prostatic tissue that were detected by prostate biopsy. MRSI identified more sites with CaP than did prostate biopsy, indicating a larger volume of cancer. In 2 patients with detectable PSA and negative prostate biopsy, MRSI identified 11 voxels with viable prostatic tissue. In patients with undetectable PSA, both MRSI and prostate biopsy showed necrosis. Ultrasound and MRI were very poor tools for identifying recurrent cancer and differentiating between viable and necrotic prostate tissue. CONCLUSIONS: 3-D MRSI is superior to TRUS and MRI in differentiating among CaP, BPH, and necrosis when local recurrence after cryosurgery is suspected. By providing chemical mapping of the prostate in contiguous voxels, the addition of spectroscopy to endorectal MRI increases the sensitivity for detection of local recurrence.

Aged↗

Three-dimensional H-1 MR spectroscopic imaging of the in situ human prostate with high (0.24-0.7-cm3) spatial resolution.

PURPOSE: To evaluate if three-dimensional hydrogen-1 magnetic resonance spectroscopic imaging (3D MRSI) when combined with a clinical MR imaging examination could discriminate prostatic adenocarcinoma from normal prostatic zonal anatomy and benign prostatic hyperplasia (BPH) on the basis of observable metabolite levels. MATERIALS AND METHODS: Combined phased-array, endorectal MR imaging and 3D MRSI was performed in nine young healthy volunteers, five patients with BPH, and 85 patients with prostate cancer and BPH. Volume MR imaging and 3D MRSI data were analytically corrected for the reception profile of the endorectal and pelvic phased-array coils, aligned with the MR imaging data, and compared with postoperative pathologic histology findings. RESULTS: Statistically significant variations in metabolite levels with prostatic zonal anatomy, age, and pathologic condition were detected with a 3D MRSI examination added to a clinical MR imaging examination. Significantly higher choline levels and significantly lower citrate levels were observed in regions of cancer compared with BPH and normal peripheral zone tissues. The ratio (choline + creatine/citrate) in regions of cancer (2.1 +/- 1.3 [standard deviation]) had no overlap with normal peripheral zone values and minimal overlap with BPH values (0.61 +/- 0.21). An estimate of the spatial extent of prostate cancer was determined by generating metabolite images in which this metabolite ratio significantly exceeded normal peripheral zone values in multiple contiguous sections. CONCLUSION: These results suggest that a 3D MRSI examination added to a clinical MR imaging examination may help define the presence and spatial extent of prostate cancer.

Adenocarcinoma↗

Prostate carcinoma: MR imaging findings after cryosurgery.

PURPOSE: To determine the morphologic changes in the prostate gland after cryosurgery and to assess the value of magnetic resonance (MR) imaging in detecting residual tumor. MATERIALS AND METHODS: Twenty-seven patients with prostate carcinoma underwent endorectal MR imaging after cryosurgery. Eighteen patients also underwent MR imaging before cryosurgery. MR findings were correlated with posttreatment clinical data, prostate-specific antigen level, and biopsy results. RESULTS: Mean prostate volume had decreased by 52% in patients examined 8 weeks or more after cryosurgery. Zonal differentiation was lost in 22 of 27 patients (81%). Areas of intraprostatic necrosis were identified in 14 of 27 patients (52%). A thick capsule enveloped the gland and neurovascular bundles in 24 of 27 patients (89%). Osteonecrosis of the symphysis pubis was seen in six of 27 patients (22%). Positive and negative predictive values for MR assessment of recurrent tumor were 44% and 73%, respectively. CONCLUSION: Cryosurgery-induced changes in the prostate gland preclude reliable detection of residual prostate carcinoma at MR imaging.

Aged↗

Prostate cancer: metabolic response to cryosurgery as detected with 3D H-1 MR spectroscopic imaging.

PURPOSE: To determine, in patients with prostate cancer treated with cryosurgery, whether levels of choline and citrate measured at magnetic resonance (MR) spectroscopy can help discriminate regions of residual tumor from other prostatic tissues and necrosis. MATERIALS AND METHODS: Combined MR imaging and three-dimensional proton spectroscopic imaging were performed in 25 patients (mean age, 69 years) with prostate cancer who underwent cryosurgery. Volume imaging and spectroscopic data were analytically corrected for the reception profile of the endorectal and pelvic phased-array coils. Spectral data were aligned with the MR imaging data and compared with serum prostate-specific antigen levels and biopsy results. RESULTS: Histologically confirmed necrotic tissue (432 voxels) did not demonstrate any observable choline or citrate. The (choline + creatine)/ citrate values in regions of histologically confirmed benign prostatic hyperplasia (0.61 +/- 0.21 [standard deviation], 52 voxels) and cancer (2.4 +/- 1.0, 65 voxels) after cryosurgery were not statistically significantly different from those before therapy but were statistically significantly different from the ratio in necrotic tissue and from each other. The (choline + creatine)/citrate images threshold and overlaid in color on T2-weighted images yielded an estimate of the spatial extent of prostate cancer and benign prostatic hyperplasia. CONCLUSION: Volume MR imaging with MR spectroscopic imaging provided a noninvasive assessment of the presence and location of residual cancer after unsuccessful therapy and helped identify successful cryosurgery in patients who still had an elevated prostate-specific antigen level.

Aged↗

Hormonal ablation of prostatic cancer: effects on prostate morphology, tumor detection, and staging by endorectal coil MR imaging.

OBJECTIVE: The purpose of our study was to evaluate the effect of androgen deprivation therapy on the MR imaging findings of prostate gland anatomy and cancer pathology in men with prostatic cancer treated with hormonal ablation before radical prostatectomy. MATERIALS AND METHODS: Twenty-two patients (mean age, 66 years old) were divided into two groups: in group I (n=10), MR imaging studies were done before and after hormonal treatment; in group II (n=12), MR imaging studies were done only after hormonal treatment. MR imaging was performed on a 1.5 T-scanner (Signa; General Electric Medical Systems, Milwaukee, WI) and included transverse plane phased-array coil T1-weighted images (TR/TE, 600/12), combined endorectal phased-array coil transverse plane T1-weighted images, fast spin-echo T2-weighted (4000/102), and coronal plane fast spin-echo T2-weighted images. Image evaluation was by consensus and included assessment of the gland size, signal intensity, tumor depiction, extracapsular extension, seminal vesicle invasion, and overall staging accuracy (Jewett and Whitmore classification). MR imaging findings were correlated with pathologic findings of step section radical prostatectomy. RESULTS: After hormonal therapy, the volume of the prostate gland showed a mean decrease of 33.5% +/- 19.6% SD (range, 0-64%). Volume reduction in the transition zone (mean 29.2% +/- 22% SD) was less than in the peripheral zone (mean, 55.8% +/- 25.8% SD) (p < .05). On T2-weighted images, the peripheral zone showed homogeneous decreases in signal intensity in 13 of 22 (58%) patients. Compared with pathologic findings, the accuracy of tumor detection by MR imaging was 74% (98 of 132 sites). Tumor presence was overestimated in 32 of 132 (24%) sites. Overall staging accuracy after hormonal ablation was 68% (15 of 22). The positive predictive value and negative predictive value for extracapsular extension were 57% (13 of 23 sites) and 90% (19 of 21 sites), respectively, and for seminal vesicle invasion were 80% (8 of 10 sites) and 97% (33 of 34 sites), respectively. CONCLUSION: As detected by MR imaging, hormonal ablation caused a decrease in size and signal intensity of the prostate gland and seminal vesicles and overestimation of tumor presence and extracapsular extension.

Aged↗

Phased array detectors and an automated intensity-correction algorithm for high-resolution MR imaging of the human brain.

Two- and four-coil phased array detectors were developed to increase the sensitivity and resolution of MR imaging of the human brain cortex, especially for detecting cortical dysplasias in pediatric epilepsy patients. An automated intensity correction algorithm based on an edge-completed, low-pass filtered image was used to correct the image intensity for the inhomogenous reception profile of the coils. Seven phased array coils were constructed and tested. The sensitivity of these coils was up to 600% higher at the surface of the cortex than that achieved with a conventional head coil and up to 30% greater at the center of the head. The sensitivity obtained was comparable with that of a conventional small surface coil, but extended over the larger dimensions of the array and previously inaccessible areas such as the top of the head. The advantages of the improved sensitivity are demonstrated with high resolution images of the brain.

Adult↗

Proton spectroscopic imaging of the human brain using phased array detectors.

Two and four-coil phased array detectors have been developed to increase the sensitivity of proton spectroscopic imaging of the human brain. These include a quadrature figure-8 coil for the study of the vertex, several arrays of 2-4 small overlapping (6-8 cm diameter) circular coils and a combination figure-8 coil plus circular coil. These were constructed in our laboratory and tested to assess their utility for brain spectroscopy. Methods for optimally combining the data from the independent receivers based on the analytical coil maps or measured signal to noise ratios (SNRs) of the data were investigated. High spatial resolution (0.2-0.4 cm3 voxel size) two- or three-dimensional chemical shift images of normal brain were obtained in 17-minute acquisitions. These spatial resolutions are comparable to those previously obtained with conventional small surface coils, but the specialized detectors allow this sensitivity to be achieved for a larger region or for previously inaccessible areas such as the top of the head. The coverage and SNR increases demonstrated are similar to those obtained in magnetic resonance phased array imaging.

Brain↗

Citrate as an in vivo marker to discriminate prostate cancer from benign prostatic hyperplasia and normal prostate peripheral zone: detection via localized proton spectroscopy.

OBJECTIVES: This study was designed to determine whether citrate levels detected by localized 1H spectroscopy could reliably discriminate regions of prostate adenocarcinoma from surrounding regions of normal peripheral zone and benign prostatic hyperplasia (BPH). METHODS: In 28 patients and 5 volunteers stimulated echo proton spectroscopy was used in conjunction with endorectal surface coils to obtain water-suppressed 1H spectra from regions of normal prostate peripheral zone, BPH, and prostate cancer. 1H spectra from prostate cancer patients were correlated with pathologic areas identified on T2-weighted endorectal coil magnetic resonance (MR) images and histologic study of the step-sectioned gland after surgery. RESULTS: The major finding of in vivo studies was consistently lower citrate levels in prostate cancer compared with BPH and normal prostate peripheral zone. This was reflected by significantly (P < 0.05) lower mean citrate/(creatine plus choline) peak area ratio observed for regions of cancer (0.67 +/- 0.17) compared with BPH (1.21 +/- 0.29) and normal peripheral zone (1.46 +/- 0.28). Moreover, there was no overlap of individual cancer and normal peripheral zone citrate ratios and no significant difference between citrate ratios in regions of normal peripheral zone in young volunteers (1.28 +/- 0.14) and age-matched patients (1.46 +/- 0.28). The observed alterations in vivo citrate levels were supported by citrate concentration data obtained from extracts of histologically proven samples of normal, benign, and malignant prostatic tissues removed at surgery. In vitro citrate levels in the normal peripheral zone (30.9 +/- 8.5 mumol/g wet weight) and BPH (46.3 +/- 5.4 mumol/g wet weight) were significantly higher than those for prostate cancer (3.74 +/- 0.54 mumol/g wet weight). CONCLUSIONS: These studies further demonstrate the potential of citrate as an in vivo marker for discriminating prostate cancer from surrounding regions of normal peripheral zone and BPH.

Adenocarcinoma↗

Prostate cancer: effect of postbiopsy hemorrhage on interpretation of MR images.

PURPOSE: To assess the frequency of changes in signal intensity after prostatic biopsy and the effect of these changes on the magnetic resonance (MR) imaging staging of prostate cancer. MATERIALS AND METHODS: Seventy-three patients with biopsy-proved prostate cancer were divided into two groups according to time between biopsy and imaging (less than and more than 21 days). The findings at MR imaging were compared with those at pathologic examination. RESULTS: Postbiopsy hemorrhage was detected in 21 of 26 (81%) patients who underwent imaging less than 21 days after biopsy and in 23 of 47 (49%) patients who underwent imaging more than 21 days after biopsy (P < .01). Postbiopsy changes persisted for as long as 4 1/2 months. Less than 21 days after biopsy, there was a tendency to overestimate tumor presence and extracapsular extension. After 21 days, tumor presence was underestimated but the positive predictive value for extracapsular extension was improved. Staging accuracy less than 21 days after biopsy was 46%; this improved to 83% after 21 days (P < .01). CONCLUSION: Staging accuracy is significantly improved when imaging is deferred for 21 days after biopsy.

Biopsy, Needle↗

Measurement of T1 relaxation times of cardiac phosphate metabolites using BIR-4 adiabatic RF pulses and a variable nutation method.

T1 relaxation times of PCr and beta-ATP in human cardiac and skeletal muscle were evaluated using a variable nutation method. This allows T1 measurements with a constant TR and a significant reduction in acquisition time compared with the partial saturation method. Four 1D CSI datasets were obtained using 30 degrees, 45 degrees, 60 degrees, and 90 degrees BIR-4 adiabatic RF pulses within 40 min. The T1 of the phosphate phantom obtained with this method agreed with values obtained with the partial saturation method. The T1s of PCr and beta-ATP in heart are 3.98 +/- 0.18 s and 1.86 +/- 0.16 s (mean +/- SE). Our results demonstrated that T1 values in heart and skeletal muscle are not significantly different.

Adenosine Triphosphate↗

Childhood adrenoleukodystrophy: assessment with proton MR spectroscopy.

PURPOSE: Image-guided, single-voxel, localized proton magnetic resonance (MR) spectroscopy was performed to assess white matter in childhood adrenoleukodystrophy (ALD). MATERIALS AND METHODS: Eleven X-linked ALD subjects, seven with neurologic symptoms or white matter lesions at MR imaging and four asymptomatic patients, were compared with nine aged-matched, healthy volunteers. RESULTS: Compared with those from normal white matter, MR spectra from white matter lesions (n = 6) showed 65% reduction in the ratio of N-acetyl aspartate (NAA) to total creatine (tCr) (P < .01); 55% increase in the ratio of choline-containing compounds (Cho) to tCr (P < .02); substantial levels of tCr; 94% increase in the ratio of glutamate, glutamine, or inositol to tCr (P < .02); and lactate accumulation in four patients. Patients without brain lesions (n = 4) exhibited a 51% increase in Cho-to-tCr ratio (P < .01) and 11% nonsignificant increase in NAA-to-tCr ratio. CONCLUSION: Proton MR spectroscopy may prove a valuable technique for noninvasive diagnostic and prognostic assessment of ALD.

Adolescent↗

Assessment of in situ renal transplant viability by 31P-MRS: experimental study in canines.

In 14 in situ canine renal transplants, intracellular phosphorus metabolites were evaluated by phosphorus-31 magnetic resonance spectroscopy (31P-MRS), performed using surface coils to investigate the usefulness of this technique for assessing renal viability in situ. Group I control kidneys (n = 5) were autografts, as were Group II (n = 5) kidneys: the latter group were subjected to surgically induced vascular ischemia and thrombosis. Group III kidneys (n = 4) were rejecting allografts. Renal flow and function, as measured by 99mTc-DTPA, and findings on histologic examination were correlated with 31P-MRS spectra. Group I kidneys showed excellent viability on both 99mTc-DTPA studies and biopsy evaluation, and their 31P-MRS-derived ratios of phosphomonoesters/inorganic phosphate (PME/Pi) and adenosine triphosphate/Pi (ATP/Pi) were high (1.32 +/- 0.23 and 0.90 +/- 0.36, respectively). In contrast, Group II kidneys demonstrated poor flow and function, histologic evidence of severe ischemia from venous and arterial thrombosis, and significantly (P < 0.005) less viability than controls, as monitored by 31P-MRS PME/Pi (0.58 +/- 0.30) and ATP/Pi (0.20 +/- 0.13) ratios. Group III kidneys also demonstrated poor flow and function with 99mTc-DTPA, and the associated histologically injury was noted to be caused by accelerated rejection and severe vascular damage. PME/Pi (0.24 +/- 0.22) and ATP/Pi (0.10 +/- 0.01) ratios were also significantly (P < 0.005) less than those in controls, reflecting nonviability. The 31P-MRS-derived PME/Pi and ATP/Pi ratios enable a qualitative noninvasive assessment of blood flow-dependent renal viability, but with currently used localization techniques the differentiation between severe ischemia and severe acute rejection was not possible.

Adenosine Triphosphate↗

Detection of significant features and statistical analysis of 2D and 3D images of 31P metabolites.

The application of spectroscopy techniques to the study of normal and pathological tissue is currently limited by the difficulties of acquiring precisely localized spectra and analyzing the resulting, relatively low signal-to-noise data. Interpretation of multivoxel spectroscopy data is greatly facilitated by estimating peak parameters and representing their spatial distribution as metabolite images. We present here the new algorithm MIMSTATS, which performs an analysis of these images and determines whether the variations in the images are statistically significant. The algorithm has been developed and tested by application to 31P CSI data from the human forearm and brain. Our results demonstrate that MIMSTATS can detect signal at a very low signal-to-noise ratio in a reliable and reproducible fashion and provides a sound basis for testing hypotheses concerning differences in distribution of metabolites.

Algorithms↗

Two-dimensional 31P-chemical shift imaging of intramuscular heterogeneity in exercising human forearm muscle.

Two-dimensional phosphorus chemical shift imaging (2D-31P-CSI) was used to investigate macroscopic heterogeneity within the flexor digitorum profundus (FDP) muscle of the human forearm during exercise. Subjects performed low-frequency steady-state finger flexion exercise at submaximal work levels using a bulb ergometer. The number of fingers actively involved in finger flexion exercise was varied in a total of 12 experiments. Active muscles could be determined by the increase of Pi and decrease of phosphocreatine observed in the localized spectra. Within the FDP, regions of active and inactive fibers were significantly different in levels of Pi and phosphocreatine (P less than 0.01) during flexion of individual fingers. Individual flexion of the index finger was found to involve only fibers in the deep region of the FDP. Fibers in the central region were found to be involved in flexion of the middle finger, and fibers in the superficial region were involved in flexion of the ring and little fingers. The results of this study demonstrate the potential of 2D-31P-CSI for in vivo investigation of intramuscular heterogeneity in human skeletal muscle.

Adult↗

Free magnesium levels in normal human brain and brain tumors: 31P chemical-shift imaging measurements at 1.5 T.

We have studied a series of normal subjects and patients with brain tumors, by using 31P three-dimensional chemical shift imaging to obtain localized 31P spectra of the brain. A significant proportion of brain cytosolic ATP in normal brain is not complexed to Mg2+, as indicated by the chemical shift delta of the beta-P resonance of ATP. The ATP beta-P resonance position in brain thus is sensitive to changes in intracellular free Mg2+ concentration and in the proportion of ATP complexed with Mg because this shift lies on the rising portion of the delta vs. Mg2+ titration curve for ATP. We have measured the ATP beta-P shift and compared intracellular free Mg2+ concentration and fractions of free ATP for normal individuals (n = 6) and a limited series of patients with brain tumors (n = 5). In four of the five spectra obtained from brain tissue containing a substantial proportion of tumor, intracellular free Mg2+ was increased, and the fraction of free ATP was decreased, compared with normal brain.

Adenosine Triphosphate↗

31P spectroscopy of the human prostate gland in vivo using a transrectal probe.

Using a transrectal probe, good quality 31P magnetic resonance spectroscopy of the human prostate was performed safely, consistently, and in a reasonable amount of time (average of 60 min). Initial results indicate that transrectal 31P MRS has the ability to characterize the phosphorylated metabolites of normal, hyperplastic, and malignant prostates. This study demonstrated that malignant prostates are characterized by significantly decreased levels of phosphocreatine (PCr) and increased levels of phosphomonoesters (PME) as compared to healthy prostates.

Adult↗

Metabolite images of the human arm: changes in spatial and temporal distribution of high energy phosphates during exercise.

Localized variations in metabolites in resting and exercising skeletal muscle have been studied using Chemical Shift Imaging (CSI) techniques to obtain 2-D arrays of 31P NMR spectra from a slice through the human forearm. The excitation profile of the coil resulted in a slice thickness of ca 80 mm and the planar resolution of the CSI data corresponded to either 7, 10 or 14 mm. The metabolite information was represented both as 2-D arrays of spectra and by constructing images of the spatial distribution of different metabolites. Correlation with the anatomy was clearly visualized by overlaying the metabolite images on the appropriate region of the corresponding proton images. At rest, significant variations in the intensity of Pi, phosphocreatine (PCr) and ATP were observed in different regions of the arm. Our planar spatial and temporal (1-9 min) resolution was also sufficient to follow changes in Pi, PCr and pH in response to exercise. These changes were restricted to the exercising muscle and demonstrated heterogeneity both in the kinetics and magnitude of response between different muscles.

Adenosine Triphosphate↗

1H MR imaging of anatomical compartments within the finger flexor muscles of the human forearm.

Fast T2-weighted 1H MRI following exercise allows investigation of the location of muscle fiber activity within skeletal muscle. Using this method, we have demonstrated that the finger flexor muscles of the human forearm consist of anatomical compartments, located at various depths, which are involved individually in flexion of the index, middle, or ring and little fingers. The results of this study indicate that the exercise protocol in 31P MRS studies of the finger flexor muscles of the human forearm, in which a small surface coil is used for detection, should be carefully reviewed.

Adult↗