Chemical shift imaging of human brain: axial, sagittal, and coronal P-31 metabolite images.

Multivoxel magnetic resonance (MR) spectroscopy and novel data analysis techniques were developed to obtain high-quality phosphorus-31 metabolite images from the human brain and to overlay each metabolite distribution directly onto corresponding hydrogen-1 MR images. The P-31 MR spectroscopic data were acquired by means of three-dimensional chemical shift imaging (phase encoding in three spatial dimensions) on a 1.5-T clinical instrument equipped with a specially designed quadrature P-31 birdcage coil constructed in the authors' laboratory. Axial, sagittal, and coronal metabolite images based on the area for any one of five peak regions (phosphodiester; phosphocreatine; gamma, alpha, and beta adenosine triphosphate) were generated from 8 X 8 X 8 or 12 X 12 X 8 CSI arrays with voxel sizes of 27 cm3 and 12 cm3, respectively. The positions of these images were aligned with anatomic features by means of the voxel-shifting capability of the Fourier transform. Direct overlays of these metabolite images on corresponding proton images demonstrated excellent correlation with anatomy, factors indicating the utility of this technique for viewing P-31 metabolite levels in all areas of the brain simultaneously.

Adult↗

Androgen sensitivity of rat prostate carcinoma studied by 31P NMR spectroscopy, 1H MR imaging, and 23Na MR imaging.

31P NMR spectroscopy, 1H magnetic resonance (MR) imaging, and 23Na MR imaging were used to study the biochemical difference between nine hormone-sensitive and six hormone-resistant rat prostate cancers and to follow bioenergetic and morphologic changes subsequent to androgen deprivation in the hormone-sensitive model. Neither 1H nor 23Na MR image characteristics were useful in distinguishing androgen-sensitive from androgen-resistant prostate cancer nor in identifying androgen deprivation. 31P NMR spectroscopy did detect bioenergetic differences between the hormone-sensitive and hormone-resistant tumors. Baseline spectra showed a significantly higher PCr/ATP ratio (mean 0.86 +/- 0.09 SEM) for hormone-sensitive tumors than for hormone-resistant tumors (mean 0.26 +/- 0.07 SEM). By 3 days after androgen deprivation (orchiectomy (castration], PCr/ATP ratios had decreased noticeably; by 1 week, the decrease was statistically significant and remained so for the rest of the study (3 weeks). It appears that 31P NMR spectroscopy is useful in detecting androgen sensitivity of prostatic carcinoma.

Androgens↗

Transrectal probe for 1H MRI and 31P MR spectroscopy of the prostate gland.

A transrectal probe for 1H imaging and 31P MR spectroscopy of the prostate gland is described. The probe is covered with plastic and consists of an insectional portion containing an rf coil and a handle containing a tuning and matching circuit. Using this transrectal probe, 1H MR images and the first 31P MR spectra of the in situ canine prostate were obtained. Serial alterations in prostate size and changes in the ratio of phosphomonoesters to ATP ratio following orchiectomy were observed. Transrectal images of the prostate appear to be superior to conventional whole body coil images in the canine. For the first time a device to obtain high signal-to-noise 1H images and 31P spectra of the in situ prostate has been constructed. This will allow the assessment of transrectal imaging and spectroscopy as tools for medical studies of prostate pathophysiology.

Administration, Rectal↗

Assessment of male infertility: correlation between results of semen analysis and phosphorus-31 magnetic resonance spectroscopy.

To evaluate the usefulness of phosphorus-31 magnetic resonance spectroscopy (31P-MRS) in assessing male infertility, we compared it with conventional semen analysis. Specimens were obtained from otherwise healthy patient groups as follows: group A, 7 fertile control subjects; group B, 12 azoospermic men after vasectomy; and group C, 11 patients presenting for infertility evaluation. Correlations between established semen analysis parameters and the 31P-MRS-derived ratio of glycerylphosphorylcholine to total phosphate (GPC/TP) were investigated. Group A controls had a mean GPC/TC ratio of 0.10 +/- 0.05, which was the same as that of group C. With the exception of significantly lowered motility and normal morphology in group C (p less than 0.001 and 0.05, respectively) semen analysis parameters in these two groups were similar. In contrast, the GPC/TP ratio in group B (0.05 +/- 0.04) was significantly different from the control (p less than 0.05), which appropriately reflected complete vasal occlusion. The results suggest that a significant portion of seminal GPC is derived from epididymal secretion and that 31P-MRS is useful for monitoring the GPC/TP levels when assessing epididymal function and male infertility.

Glycerylphosphorylcholine↗

P-31 MR spectroscopy in assessing testicular torsion: rat model.

To develop phosphorus-31 magnetic resonance (MR) spectroscopy as an indicator of testicular viability, unilateral 720 degrees torsion of the spermatic cord was performed in 11 Copenhagen rats. In six of 11 rats, detorsion was done 1 hour later. The authors used special surface coils to obtain P-31 MR spectra (at 2 T) from both tests, then correlated MR findings with those from gross morphologic and histologic examination. In the normal testis, P-31 MR spectra had prominent phosphomonoester (PME) and adenosinetriphosphate (ATP) peaks. Testicular torsion dramatically reduced ATP to almost undetectable levels and significantly decreased the PME/Pi at 1 hour (1.18 +/- 0.22) in nine rats. In two rats, however, no spectral changes were present. Of the six rats in which detorsion was performed, three showed immediate regeneration of ATP and a normal PME/Pi (2.87 +/- 0.06) 3 hours later; testicles in the other three rats did not recover (PME/Pi = 0.72 +/- 0.01). Because gross morphologic observations and histologic findings prior to detorsion were unable to differentiate viable from nonviable tests, these preliminary data suggest P-31 MR spectroscopy may help clinicians diagnose testicular torsion and assess testicular viability.

Animals↗

Complete and partial ureteral obstruction: evaluation of renal effects with P-31 MR spectroscopy and Tc-DMSA scintigraphy.

Phosphorus-31 magnetic resonance (MR) spectroscopy was used to study the effects of partial and complete ureteral obstruction on the porcine kidney; results were compared with renal tubular function as determined with technetium-99m dimercaptosuccinic acid (DMSA) scintigraphy. Twenty-seven pigs were used: nine as sham-operated controls, six with partial ureteral obstruction, and 12 with complete ureteral obstruction. P-31 MR spectra and Tc-DMSA scintiscans were obtained weekly over 3 weeks. Partial obstruction caused no significant change in P-31 MR spectra, whereas Tc-DMSA scintiscans showed a 74% decrease in tubular function by the end of 3 weeks. Complete obstruction caused a 43% reduction in the mean adenosine triphosphate (ATP) to inorganic phosphate (Pi) ratio, which paralleled the 96% decrease in Tc-DMSA uptake over 3 weeks. The difference in ATP/Pi ratios between control and completely obstructed kidneys was significant (P less than .01) at 2 and 3 weeks after ligation. These results indicate that radionuclide Tc-99m DMSA uptake is very sensitive to the pathophysiologic changes in renal tubular function, while the organ average cellular bioenergetic state (ATP/Pi) is not as strongly affected.

Adenosine Triphosphate↗

Assessment of clinical renal preservation by phosphorus-31 magnetic resonance spectroscopy.

To evaluate the role of magnetic resonance spectroscopy (MRS) and to develop surface coils for assessing cadaveric renal viability during hypothermic storage, we used the monophosphate/inorganic phosphate ratio (MP/Pi) to monitor phosphorous metabolites in intact kidneys during various renal preservation maneuvers. Eighteen canine kidneys and 16 cadaveric kidneys were studied as follows: Group 1 (N = 4) in situ kidneys were monitored by implanted MRS coils; Group 1 (N = 4) ex vivo kidneys were immediately attached to vascular cannulas and monitored by MRS surface coils during normothermic perfusion; Group 3 (N = 4) kidneys were removed, cold-flushed and, after 24 hours of 4C storage, monitored by MRS surface coils before and during four hours of reperfusion via vascular cannulas; Group 4 (N = 6) kidneys were removed, cold-flushed and monitored by surface coils during cold storage up to 72 hours. In addition, 16 cadaveric kidneys were studied while in sterile cold-storage containers. Postoperative renal function was followed in recipient patients. The MP/Pi ratios in Group 1 kidneys correlated with the ability to regenerate adenosine triphosphate (ATP). Groups 2 and 3 showed similar regeneration of ATP and MP/Pi after postischemic reperfusion, and the signal-to-noise ratios of the surface coils were better than those in the implanted coils in Group 1. Surface-coil monitoring in Group 4 kidneys showed predictable decay rates of MP/Pi during one to 72 hours of cold storage; in contrast, simultaneous cortical medullary microcirculation studies with 99mTc-macroaggregated albumin were inconclusive. Human cadaveric kidneys with high MP levels were associated with excellent renal function after transplantation, while those with low MP (less than or equal to 0.50) were associated with nonviability. We conclude that MRS is a practical and safe diagnostic modality for clinical transplantation.

Adenosine Triphosphate↗

Assessment of testicular metabolic integrity with P-31 MR spectroscopy.

To evaluate the reliability of phosphorus-31 magnetic resonance (MR) spectroscopy in the assessment of acute testicular ischemia, vascular integrity, and spermatogenesis, the authors studied in vivo canine and primate testicles grouped as follows: group 1 testes (n = 8), in situ canine controls; group 2 (n = 11), canine testes subjected to warm ischemia; group 3, canine (n = 4) and primate (n = 4) testicles from hormone-treated animals. Group 1 control testicles showed high monophosphoester (MP) levels; low levels of inorganic phosphate (Pi), phosphodiester (PD), and phosphocreatine; and high levels of adenosine triphosphate (ATP). Group 2 testes revealed a time-dependent decay of MP/Pi ratios (from 2.1 to 0.70). Regeneration of ATP was noted in the acute reperfusion period. After 6 weeks of pituitary gonadotropin suppression, group 3 testes showed a significant decrease (P less than .05) in MP/PD ratios from a control level of 2.6 +/- 0.3 and a decrease in the MP/beta-ATP ratio from 2.4 +/- 0.1 to 1.8 +/- 0.3. P-31 MR spectroscopy appears to be a potential method for noninvasively assessing testicular ischemic injury and the metabolic integrity of spermatogenesis.

Animals↗

Assessment of renal preservation by phosphorus-31 magnetic resonance spectroscopy: in vivo normothermic blood perfusion.

To evaluate the usefulness of the monophosphate/inorganic phosphate ratio (MP/Pi) in assessing renal viability in a renal transplantation setting, we monitored intracellular phosphorous metabolites of 33 canine kidneys by phosphorus-31 magnetic resonance spectroscopy (MRS) after various amounts of ischemia. Renal viability (adequate perfusion and function) was directly assessed by the presence of intraoperative urine production in each kidney. Twelve normal, well-perfused kidneys (Group 1) exhibited high control MP/Pi ratios, with a mean of 0.87 +/- 0.12. Six in situ kidneys (Group 2), subjected to 45 minutes' warm ischemia followed by reperfusion, had a mean MP/Pi ratio of 0.50 +/- 0.12 after warm ischemia, which increased by a mean of 0.50 +/- 0.11 (to 1.0 +/- 0.07) after two to four hours of reperfusion. Fifteen kidneys (Group 3) were removed, cold-flushed and transplanted after 24 hours of hypothermic storage. In eight (Group 3A), reperfusion was excellent; in seven (Group 3B), reperfusion was inadequate secondary to hypotension in two, hemorrhage in two, and renal vein thrombosis in three. Group 3A kidneys had a mean MP/Pi ratio after cold-storage ischemia of 0.54 +/- 0.08. After successful transplantation and two to four hours of reperfusion, this increased by a mean of 0.23 +/- 0.12 to 0.77 +/- 0.15. Group 3B kidneys all showed a continuous decline of MP/Pi, with a mean loss of 0.26 +/- 0.09 from baseline values (mean 0.56 +/- 0.08) to nonviable levels of 0.28 +/- 0.12 within four hours of transplantation. We conclude that MP/Pi ratios enable assessment of renal viability and ischemic damage and can predict the efficacy of renal preservation maneuvers in the dog kidney. These preliminary data support the theory that MRS can be applied to the noninvasive assessment of viability in ex vivo, cold-stored cadaveric human kidneys awaiting renal transplantation.

Animals↗

Assessment of renal viability by phosphorus-31 magnetic resonance spectroscopy.

To assess the applicability of phosphorus-31 magnetic resonance spectroscopy (31P-MRS) in the analysis of renal transplant viability and preservation techniques with respect to pre-transplant ischemia, we studied two rat groups. Twenty-five rat kidneys were subjected to various time increments of warm ischemia (Group A), and 31P-MRS was performed on each kidney at time intervals of up to 72 hours during simple hypothermic storage. We correlated findings of 31P-MRS with simultaneous findings of electron microscopic (EM) ultrastructural viability parameters (in Group A) and subsequent survival and renal function in 30 rats (Group B) subjected to similar amounts of variable ischemia. Intracellular phosphorus metabolite levels were nondestructively monitored by 31P-MRS via spectral peaks of NAD, sugar monophosphates (SP), and inorganic phosphate (Pi). We concluded: SP/Pi and NAD/Pi ratios decay in a time-dependent manner for both warm and cold ischemia, although this process is much slower during cold storage; EM viability parameters correlate with the development of acute tubular necrosis (irreversible damage) versus nonviability (gross cell death) on a qualitative basis only; and 31P-MRS enables a quantitative assessment of renal viability and ischemic renal damage and can predict the degree of acute tubular necrosis and post-ischemic renal function. 31P-MRS is potentially a noninvasive, nondestructive method of assessing viability during simple hypothermic storage of the rat kidney. Preliminary evidence shows that this MRS method can be applied to human kidney viability studies for clinical renal transplantation and urologic research concerning renal preservation.

Animals↗

Localized proton MR spectroscopy of the brain in children.

Small-voxel (3.0-8.0 cm3), magnetic resonance (MR) imaging-guided proton MR spectroscopy was performed in 54 patients (aged 6 days to 19 years) with intracranial masses (n = 16), neurodegenerative disorders (n = 34), and other neurologic diseases (n = 4) and in 23 age-matched control subjects without brain disease. A combined short TE (18 msec) stimulated-echo acquisition mode (STEAM) and long TE (135 and/or 270 msec) spin-echo point-resolved spatially localized spectroscopy (PRESS) protocol, using designed radio-frequency pulses, was performed at 1.5 T. STEAM spectra revealed short T2 and/or strongly coupled metabolites; prominent resonances were obtained from N-acetyl aspartate (NAA), choline-containing compounds (Cho), and total creatine (tCr). Lactate was well resolved with the long TE PRESS sequence. Intracranial tumors were readily differentiated from cerebrospinal fluid (CSF) collections. All tumors showed low NAA, high Cho, and reduced tCr levels. Neurodegenerative disorders showed low or absent NAA levels and enhanced mobile lipid, glutamate and glutamine, and inositol levels, consistent with neuronal loss, gliosis, demyelination, and amino acid neurotoxicity. Preliminary experience indicates that proton MR spectroscopy can contribute in the evaluation of central nervous system abnormalities of infants and children.

Adolescent↗

Registration of images from sequential MR studies of the brain.

For sequential studies of patients with brain tumors, the authors have designed an automated registration procedure for intra- and interexamination alignment of magnetic resonance images. This was evaluated with artificially misregistered data and data from repeat studies of six healthy volunteers and six brain tumor patients. In a subset of cases, a manual procedure based on matching of neuroanatomic landmarks was also applied for comparison. The results showed that the technique is robust and reproducible, giving an accuracy in the range of 1-2 mm, which corresponded to the spatial resolution of the images. Subject motion between imaging sequences within the same study was negligible, although adjustments (one to two section thicknesses) were required in the z direction to correlate multisection and volume images and to allow accurate image segmentation. For alignment between sequential volunteer and patient examinations, translations of up to 22 mm and rotations in the x, y, and z axes of up to 9 degrees were required. This alignment procedure may be valuable in numerous aspects of treatment planning and patient follow-up.

Adult↗

Surface coil MR imaging of the human brain with an analytic reception profile correction.

An analytic correction method was developed and applied to correct the signal intensity nonuniformity caused by the inhomogeneous reception profile of surface coils used--because of their higher sensitivity--for magnetic resonance imaging of the brain at 1.5 T. The reception profile was analytically modeled by using the Biot-Savart law. The correction considerably improved visual interpretation of the images by modeling and removing the dependence of signal intensity on distance from the coil. The method can be used for single or multiple coils of any planar geometry and in any orientation. Application of this technique allows imaging of the brain with surface coils, yielding increased resolution and signal-to-noise ratio, without the penalty of image nonuniformity.

Brain↗

High resolution T2-weighted imaging of the human brain using surface coils and an analytical reception profile correction.

High spatial resolution T2-weighted MR images of the human brain were obtained at 1.5 T. An optimized fast spin-echo (FSE) sequence and 1.5 g/cm gradients were used to obtain T2-weighted images in 4 to 9 minutes with an in-plane resolution of .27 mm and slice thicknesses from 1.5 to 3 mm. Phased arrays of surface coils were used as receivers, providing increased sensitivity but image intensities dependent on the reception profile of the coils. This image nonuniformity was removed by analyzing the data with a theoretical intensity correction algorithm developed in this laboratory. The FSE sequences, the specialized phased arrays of surface coils, and the intensity correction algorithm allowed improved visualization of nerves within the inner auditory canals and surface anatomy of the cerebral cortex. It is expected that this technique will be useful for clinical applications that require high resolution imaging of small, superficial structures of the brain.

Algorithms↗

Improved solvent suppression and increased spatial excitation bandwidths for three-dimensional PRESS CSI using phase-compensating spectral/spatial spin-echo pulses.

Dual phase-compensating spectral/spatial echo-planar (EP) spin-echo (SE) pulses were incorporated into the point resolved spectroscopy (PRESS) excitation sequence to improve water and lipid suppression for 1H chemical shift imaging (CSI) and to decrease the dependence of the PRESS box location upon chemical shift. The asymmetric EPSE pulses (either minimum or maximum phase in the chemical shift domain) were substituted for the two PRESS SE pulses to yield zero phase spectra. Three different pulses were designed and tested at 1.5 T. Pulse 1, targeted for brain CSI (TE > 85 msec), passed choline to lipid resonances, suppressed water, and rephased the methyl lactate doublet independently of TE. Pulse 2, targeted for general purpose shorter TE PRESS, possessed both high chemical shift and spatial domain bandwidths. Pulse 3, designed for prostate CSI, passed choline to citrate resonances while suppressing lipids and water. The three pulses possessed spatial bandwidths ranging between 3.3 and 5.0 kHz, more than three times higher than that offered by one-dimensional SE pulses of equivalent maximum B1 amplitude. Phantom and in vivo experimental results demonstrated that, for EPSE pulses 1 and 2, suppression factors higher than 10(4) were achieved. The increased spatial bandwidths resulted in less contamination by signals from outside the designated PRESS excited region and a significant improvement in the uniformity of metabolite intensities for voxels located near edges of the PRESS box.

Aged↗

Volume MRI and MRSI techniques for the quantitation of treatment response in brain tumors: presentation of a detailed case study.

Patients with primary brain tumors may be considered for several different treatments during the course of their disease. Assessments of disease progression and response to therapy are typically performed by visual interpretation of serial MRI examinations. Although such examinations provide useful morphologic information, they are unable to reliably distinguish active tumor from radiation necrosis. This poses a particular problem in the assessment of response to localized radiation therapies such as gamma knife radiosurgery. In this paper, we present methodology for evaluating changes in tissue morphology and metabolism based on serial volumetric MRI and magnetic resonance spectroscopic imaging (MRSI) examinations. Registration and quantitative analysis of these data provide measurements of the temporal and spatial distributions of gadolinium enhancement and of N-acetylasparate, choline, creatine, and lactate/lipid. The key features of this approach and the potential clinical benefits are illustrated by a detailed analysis of six serial MRI/MRSI examinations and three serial 1-[F-18] fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) studies on a patient with a recurrent anaplastic astrocytoma.

Adult↗

Three-dimensional magnetic resonance spectroscopic imaging of brain and prostate cancer.

Clinical applications of magnetic resonance spectroscopic imaging (MRSI) for the study of brain and prostate cancer have expanded significantly over the past 10 years. Proton MRSI studies of the brain and prostate have demonstrated the feasibility of noninvasively assessing human cancers based on metabolite levels before and after therapy in a clinically reasonable amount of time. MRSI provides a unique biochemical "window" to study cellular metabolism noninvasively. MRSI studies have demonstrated dramatic spectral differences between normal brain tissue (low choline and high N-acetyl aspartate, NAA) and prostate (low choline and high citrate) compared to brain (low NAA, high choline) and prostate (low citrate, high choline) tumors. The presence of edema and necrosis in both the prostate and brain was reflected by a reduction of the intensity of all resonances due to reduced cell density. MRSI was able to discriminate necrosis (absence of all metabolites, except lipids and lactate) from viable normal tissue and cancer following therapy. The results of current MRSI studies also provide evidence that the magnitude of metabolic changes in regions of cancer before therapy as well as the magnitude and time course of metabolic changes after therapy can improve our understanding of cancer aggressiveness and mechanisms of therapeutic response. Clinically, combined MRI/MRSI has already demonstrated the potential for improved diagnosis, staging and treatment planning of brain and prostate cancer. Additionally, studies are under way to determine the accuracy of anatomic and metabolic parameters in providing an objective quantitative basis for assessing disease progression and response to therapy.

Brain Neoplasms↗

Alignment of volume MR images and high resolution [18F]fluorodeoxyglucose PET images for the evaluation of patients with brain tumors.

PURPOSE: The goal of the study was to investigate the use of automated registration techniques for interpretation of volume MR and high resolution FDG-PET images that were obtained from patients with brain tumors. METHOD: Twenty-one patients with brain tumors were studied on one or more occasions using MRI and high resolution FDG-PET. The data were aligned using automated volume- and surface-matching algorithms. Composite images comprising the resliced pre- and postgadolinium spoiled GRE, T2-weighted SE, and PET data were constructed to correlate intensities of regions on the PET images with regions that corresponded to normal gray matter, white matter, and gadolinium enhancement. RESULTS: The accuracy of registration between the MR and PET images was estimated to be within 1-2 mm based upon the distance between surfaces of the outside of the head. In 12 of the 24 examinations, there were diagnoses of recurrent tumor, with only 5 of these exhibiting regions of higher FDG uptake than normal gray matter. For 19 of the 24 studies, the anatomic context provided by the registered MR images was found to be important in distinguishing recurrent tumor from necrosis based upon FDG uptake. CONCLUSION: The automated alignment was found to be an important factor in interpreting the high resolution PET images. This was particularly true for small lesions close to the cortex and for situations where FDG uptake had been reduced by prior treatment with radiation therapy.

Adult↗