PubMed HealthSearch

Biomedical subjects

D Bayse

Publications and source records attributed to D Bayse.

6 recordsLinked to original sources

A candidate reference method for uric acid in serum. I. Optimization and evaluation.

We describe our optimization and evaluation of a candidate Reference Method for uric acid in serum. Reaction parameters were optimized for a manual, enzymic method for uric acid in which highly purified microbial uricase is used to quantitate uric acid by a differential ultraviolet procedure. We evaluated the method in terms of freedom from interferences, analytical recovery, precision, and comparison with five other uric acid methods. We conclude that (a) the candidate uric acid Reference Method exhibits the least interference; (b) all six methods exhibit satisfactory analytical recoveries and precision; and (c) results by all six methods agree well. As a result of this evaluation study, the manual ultraviolet uricase method for uric acid, with Tris as buffer, was chosen as the candidate Reference Method for uric acid.

Adult

A candidate reference method for uric acid in serum. II. Interlaboratory testing.

We describe the interlaboratory testing of a candidate Reference Method (Part I) for uric acid in serum. The method is based on the ultrasound spectrophotometric quantitation of uric acid before and after incubation with uricase. A comprehensive investigation involving 12 laboratories was organized to document the transferability, intra- and interlaboratory precision, and general reliability of the candidate Reference Method. The interlaboratory CV with this method was about 2 to 6% for uric acid concentrations ranging from 0.12 to 0.60 mmol/L. The results detailed here demonstrate that the method can be successfully duplicated among different laboratories.

Evaluation Studies as Topic

Determination of paraquat in marijuana by reversed-phase paired-ion high performance liquid chromatography.

A sensitive and selective method is described for the quantitative determination of paraquat in marijuana. Paraquat is extracted from finely ground plant material with hydrochloric acid with sonification, and the resulting acidic solution is extracted with chloroform:isopropanol (9:1) and evaporated to dryness. The residue is reconstituted with aqueous phosphate buffer pH 7.0; the solution is passed through a C-18 SEP-PAK TM and is analyzed with high performance liquid chromatography, using a reversed-phase column and an "ion pairing" reagent in the mobile phase. The recovery of paraquat in laboratory-spiked material varied from 90-97%. Results obtained with confiscated, field-sprayed marijuana by the procedure described were in excellent agreement with those obtained with a well-established ultraviolet procedure. The calculated limit of detection with this method is 2 ng of paraquat.

Cannabis