Publications and source records attributed to D C Joy.

4 recordsLinked to original sources

High-resolution scanning electron microscopy.

The spatial resolution of the scanning electron microscope is limited by at least three factors: the diameter of the electron probe, the size and shape of the beam/specimen interaction volume with the solid for the mode of imaging employed and the Poisson statistics of the detected signal. Any practical consideration of the high-resolution performance of the SEM must therefore also involve a knowledge of the contrast available from the signal producing the image and the radiation sensitivity of the specimen. With state-of-the-art electron optics, resolutions of the order of 1 nm are now possible. The optimum conditions for achieving such performance with the minimum radiation damage to the specimen correspond to beam energies in the range 1-3 keV. Progress beyond this level may be restricted by the delocalization of SE production and ultimate limits to electron-optical performance.

Electrons

High resolution SE-I SEM study of enamel crystal morphology.

Until recently high resolution TEM was the only imaging mode capable of probing the atomic lattice structure of crystals composing tooth enamel. Studies designed to determine the polyhedral shape of normal enamel crystals and initiation of carious lesions in enamel crystals were hampered and limited by interpretation of two-dimensional TEM images from thin section and freeze fracture replica specimens lacking depth of field. The newly developed SE-I signal mode for SEM (SE-I/SE-II ratio) can produce images of enamel crystals approaching beam diameter dimensions (0.7-2.0 nm), rivaling the resolution of the TEM technique and generating topographic contrasts for three dimensional imaging at very high magnification (approximately 1,000,000X). Ultrathin chromium (Cr) films generate enriched high resolution SE-I contrasts of enamel crystal surfaces and when imaged using an immersion lens field emission SEM operated at high voltage (20-30 KeV) produce unsurpassed topographic contrasts. Since the grain size of Cr is below the resolution of any SEM and is ultrathin (approximately 1 nm), then SE-I images can provide a more accurate representation of enamel crystal structure than TEM methodologies. Our SE-I SEM observations of normal human enamel crystals reveal fractured spicules which contain angled flat surfaces delineated by a prominent 2 nm wide SE-I edge brightness contrast. Although microscopic observations often show crystals which are hexagonal in cross-section, in both SEM and TEM many other growth habits, including rectangular or irregular crystals (30-40 nm in width) which contain "notches," are also observed. More detailed morphological studies are therefore required to determine the most likely habit planes and their relevance to the function of the enamel crystals.(ABSTRACT TRUNCATED AT 250 WORDS)

Chromium

Fluorinated molecule as a tracer: difluoroserotonin in human platelets mapped by electron energy-loss spectroscopy.

The intracellular distribution of fluorine has been delineated in human platelets incubated with 4,6-difluoroserotonin, utilizing a scanning-transmission electron microscope equipped with an energy-loss spectrometer. Discrete intracellular structures corresponding in location to dense bodies contained high concentrations of fluorine. Electron energy-loss spectroscopy, which apparently can detect less than 10(-20) gram of fluorine in an area of 10 square nonometers, can thus localize fluorinated tracer molecules with biological activity.

Blood Platelets

The formation and interpretation of defect images from crystalline materials in a scanning transmission electron microscope.

The technique of scanning transmission electron microscopy (STEM) has been employed usefully in studies of amorphous materials, and the theory of image formation and interpretation in this case has been well developed. Less attention has been given to the practical and theoretical problems associated with the use of STEM for the examination of crystalline materials. In this case the contrast mechanisms are dominated by Bragg diffraction and so they are quite different from those occurring in amorphous substances. In this paper practical techniques for the observation and interpretation of contrast from defects in crystalline materials are discussed. It is shown that whilst images of defects are obtained readily under all typical STEM operating conditions, the form of the image and the information it contains varies with the angle subtended at the specimen by the detector. If this angle is too large significant image modifications relative to the "conventional" transmission electron microscope case may occur and the resolution of the image may degrade. If this angle is too small, then signal to noise considerations make an interpretation of the image difficult. In this paper we indicate how the detector angle may be chosen correctly, and also present techniques for setting up a STEM instrument for imaging a crystalline material containing lattice defects.

Crystallography