Determination of contact area in 'cushion form' bearings for artificial hip joints.

Current forms of artificial hip joints produce wear debris, which contributes to loosening of the prostheses. These 'hard' joints articulate with boundary or mixed lubrication, whereas the natural joint articulates with full fluid film lubrication. An artificial joint that articulates with full fluid film lubrication could greatly reduce wear and frictional torque and hence reduce the incidence of loosening and inflammatory tissue reaction. The use of a thin lining of low elastic modulus in the acetabular cup is one possible way of promoting full fluid film lubrication. In the design of such cushion forms of bearings, it is important to be able to predict the contact area, stress distribution and film thickness. This paper presents experimental techniques to determine the contact area in low elastic modulus layers and compares these measured areas with theoretical predictions using linear elasticity theory. At low loads experimental results and theoretical predictions were close. However, at loads above 300 N, the theory overestimated the width of the contact area by up to 8.5 per cent. This difference is mainly attributed to the non-linear behaviour of the elastomer at the higher levels of stress.

Elasticity↗

External wear of the polyethylene socket in cemented total hip arthroplasty.

We examined 59 cemented high density polyethylene sockets removed at revision hip arthroplasty. Of these 19 showed areas of wear between the outside of the socket and the acetabular bone. This was associated with lack of acrylic cement in those areas and was also related to the depth of the wear on the articulating surface of the socket. It is suggested that, in some cases, changes at the bone-cement junction are secondary to socket loosening and abrasion against the bone of the acetabulum, rather than to particles migrating from the metal-polyethylene interface. It is therefore important that impingement of the neck of the femoral stem on the edge of the cup be avoided and that, when the socket is inserted, it is not in direct contact with the bone.

Acetabulum↗

Elbow joint forces in patients with rheumatoid arthritis.

Whilst developing an elbow endoprosthesis, the joint forces were estimated for patients with rheumatoid arthritis. Elbow flexion strength of rheumatoid patients was found to be 45% of normal. Muscle strengths and limb geometry data were found by a dissection technique, which allowed joint forces to be calculated during flexion, extension and abduction efforts. Forces up to 2.4 kN were predicted to act on the distal humerus, with similar forces acting in both radius and ulna. The skeletal structure is well adapted to carry the predicted forces, and onlay-type prostheses are recommended for elbow replacement.

Adult↗