The derivation of elbow joint forces, and their relation to prosthesis design.

A literature review showed a lack of accurate data for upper limb joint forces. After discussing methods to determine muscle forces, the physiological cross-sections of muscles were used to estimate their strengths. Elbow joint forces were predicted for isometric actions which gave severe loading conditions. The predicted forces were discussed in relation to prosthesis design, and the use of a radial head replacement was recommended.

Biomechanical Phenomena↗

The characteristics of acetabular cups worn in the human body.

In laboratory tests, the ultra-high molecular weight polyethylene used for the acetabular cups of Charnley hip prostheses has a very low wear rate against steel. In the body radiographic measurements indicate that the polyethylene wears more rapidly. In order to investigate this higher wear rate, the sockets of acetabular cups removed at post-mortem have been examined using optical and electron microscopy. It has been shown that a socket wears predominantly on its superior part and that this is a direct consequence of the orientation of the cup in the body and the direction of loading of the hip. In the worn region the femoral head in effect bores out a new socket for itself, a process which is visible with the naked eye after approximately eight years. Electron microscopy shows that the predominant wear mechanism is adhesion, but after about eight years the appearance of surface cracks suggests that surface fatigue is taking place in addition to this. Laboratory wear tests have shown that pure surface fatigue is not sufficient to account for the high clinical wear rate. Other deformation processes are suggested and discussed with regard to the higher clinical wear rate.

Acetabulum↗

Lubrication of synovial membrane.

(1) An apparatus has been constructed to measure the coefficient of friction of synovial membrane against a glass slider. (2) Provision was made to vary the load on the specimens. (3) The coefficient of friction varied from 0-006 to 0-07. (4) A presentation similar to that used in the Sommerfeld analysis of journal bearings indicated that in these experiments synovial membrane was lubricated in the hydrodynamic regimen.

Adult↗

Lubrication and cartilage.

Mechanisms of lubrication of human synovial joints have been analysed in terms of the operating conditions of the joint, the synovial fluid and articular cartilage. In the hip and knee during a walking cycle the load may rise up to four times body weight. In the knee on dropping one metre the load may go up to 25 time body weight. The elastic modulus of cartilage is similar to that of the synthetic rubber of a car tyre. The cartilage surface is rough and in elderly specimens the centre line average is 2-75 mum. The friction force generated in reciprocating tests shows that both cartilage and synovial fluid are important in lubrication. The viscosity-shear rate relationships of normal synovial fluid show that it is non-Newtonian. Osteoarthrosic fluid is less so and rheumatoid fluid is more nearly Newtonian. Experiments with hip joints in a pendulum machine show that fluid film lubrication obtains at some phases of joint action. Boundary lubrication prevails under certain conditions and has been examined with a reciprocating friction machine. Digestion of hyaluronate does not alter the boundary lubrication, but trypsin digestion does. Surface active substances (lauryl sulphate and cetyl 3-ammonium bromide) give a lubricating ability similar to that of synovial fluid. The effectiveness of the two substances varies with pH.

Cartilage, Articular↗

Some new evidence on human joint lubrication.

Theoretical consideration has been given to the use of pendulum machines which are used to examine the frictional properties of human joints by incorporating them as fulcra. As a result, a new type of pendulum machine has been built which incorporates the facility to apply sudden loads to the joint on starting the swinging motion, and also the ability to measure directly the frictional torque experienced by the joint. The results obtained from natural hip joints indicate the presence of squeeze film lubrication under conditions of sudden loading of a joint. In addition, a self-generated fluid film process was observed at low loads while at higher loads boundary lubrication appeared to be important. These results have been used to describe the lubrication regimens occurring in a normal activity such as walking. A single experiment carried out on a hip from a patient suffering from severe rheumatoid arthritis has also been reported and the frictional resistance was seen to be increased fifteenfold compared to a normal hip.

Arthritis, Rheumatoid↗

Quantitative study of stiffness in the knee joint.

Data from a knee arthrograph, which imparts a passive sinusoidal motion to the joint and measures the resistive torque and displacement, have been shown to be reproducible. Tests carried out on joints (from 49 males, 21 females) showed that the energy loss per cycle of the joint increased with age for both sexes but the peak to peak torque (elastic stiffness) did not vary with age. Muscle bulk had a large influence on the stiffness (both dissipative and elastic) of the knee as did the size of the joint itself. Women's knee joints exhibited lower values of dissipative energy loss and peak to peak torque than men's for all ages and sizes of joints.

Adult↗

Evaluation of silicone as an artificial lubricant in osteoarthrotic joints.

Silicone 300 has been evaluated as an artificial lubricant in osteoarthrotic joints by means of a pilot study in five inpatients and a control trial of 25 outpatients with 40 osteoarthrotic knees. Sequential analysis showed a significant benefit from saline compared with silicone at one week follow-up and no significant difference at one month.Measurement of stiffness with a knee arthrograph showed no difference in reduction of stiffness between the two substances. In a study of 18 rabbits there was no evidence that silicone was retained in the joint cavity for longer than 48 hours. There was a failure of clearance of iodinated serum albumin for as long as three to four days after the injection of silicone, suggesting some obstruction to lymphatic outflow. Experimentally produced cartilaginous defects did not heal quicker with the injection of silicone into the joint.

Animals↗