PubMed Health⌕ Search

Biomedical subjects

D E Raeside

Publications and source records attributed to D E Raeside.

35 records · Page 2Linked to original sources

Echocardiogram analysis in a pattern recognition framework.

Echocardiogram analysis is treated in a pattern recognition framework. Anterior mitral leaflet waveforms are classified for the four-class problem consisting of the classes "normal," "mitral stenosis," "mitral valve prolapse," and "idiopathic hypertrophic subaortic stenosis." In addition, aortic root waveforms and left ventricular wall waveforms are classified for the two-class problem consisting of the classes "normal" and "idiopathic hypertrophic subaortic stenosis." One common method of analysis (Fourier analysis) underlies each classification scheme. Classification accuracy is sufficiently good to warrant the inference that successful automated decision-making based on the algorithms investigated is feasible.

Aortic Valve↗

Monte Carlo advice.

The generation of long, high quality random number sequences for Monte Carlo simulations using minicomputers is considered. The importance of the thorough testing of Monte Carlo random number generators is emphasized. A recommendation is given to authors of Monte Carlo papers to specify their random number generator and to describe the randomness testing which that generator has undergone.

Computers↗

Monte Carlo simulation of the dose distribution around 125I seeds.

The Monte Carlo method was used to investigate dose distributions around the 3M Company model 6701 and model 6702 125I brachytherapy seeds. The transverse axis dose distributions of the two seed models were found to be nearly identical, but the longitudinal axis dose distributions differed significantly. Seed design influences upon dose distributions also were investigated.

Humans↗

Two-dimensional dose distribution around a commercial 125I seed.

The Monte Carlo method was used to investigate the dose distribution around a 3M Company model 6711 125I seed immersed in a water phantom. Dose rate per unit activity data are presented as a matrix of 63 points surrounding the seed. Relative dose data are presented graphically for two mutually perpendicular directions and compared with the corresponding data for the only other 125I seed currently available, the 3M Company model 6702 125I seed. The 6711 relative dose distribution decreases more rapidly with distance from the seed than does the 6702 relative dose distribution. Uncertainties in the 6711 seed dose distribution produced by end-weld thickness variations were investigated and found to be substantial at certain points.

Brachytherapy↗

An improved electron multiple-scattering distribution for Monte Carlo transport simulation.

An improved electron multiple-scattering distribution is presented in the form of a composite function which combines three expressions valid over different scattering angle regions: a modified relativistic Mott single-scattering term for large angle scattering, a modified Moliere Gaussian term for small angle scattering, and an exponential term for the intermediate angle scattering region. The exponential term has two adjustable parameters which make possible the smooth transition from the large to the small scattering angle regions. The proposed distribution exhibits better agreement with experiment than other multiple-scattering distributions commonly used in Monte Carlo electron transport codes, is amenable to direct sampling over a continuous range of electron energies and step sizes, can be used for elements of any atomic number, and is particularly suitable for use on small memory computers.

Electrons↗

The accuracy of single-seed dose superposition for I-125 implants.

The Monte Carlo method was used to study perturbations of single I-125 seed dose distributions created by the presence of one or three neighboring seeds for the case of seeds immersed in a water phantom. Perturbation factors were determined within the geometric shadow of neighboring seeds for two-seed designs, four-seed spacings, and several choices of dose point. The results were compared to dose estimates obtained by the simple superposition of single-seed data for one- and two-plane implants. Some significant differences were found.

Brachytherapy↗

Optimal electron-beam treatment planning for retinoblastoma using a new three-dimensional Monte Carlo-based treatment planning system.

Electron-beam treatment planning for retinoblastoma was investigated and an optimal treatment plan was devised for a particular case using a new three-dimensional Monte Carlo-based treatment planning system known to be capable of correctly predicting dose perturbations caused by body surface obliquities and tissue heterogeneities. Computed tomography (CT) data files were used to construct a three-dimensional eye phantom representing the anatomy of a child's orbit. Dose distributions in sagittal, transverse, and coronal planes were predicted with 1-mm resolution. Study of these distributions led to an optimal treatment plan consisting of an anterior-lateral pair, with the anterior field being a 10-MeV, 30-mm-diam circular field, centrally blocked by a 10-mm-diam lucite lens shield and the lateral field being a 16-MeV, 30 x 25-mm D-shaped field. The anterior field delivers a therapeutic dose to the ora serrata, but it underdoses the posterior retinal surface behind the lens shield; the lateral field provides the necessary boost dose to the posterior retinal surface. An equally weighted combination of the two fields produces a dose distribution in which the entire retinal surface receives a therapeutic dose, with less than 10% of that dose being delivered to the lens, brain, and the contralateral orbit.

Electrons↗

An interactive program to calculate the treatment time for 60Co single beam, opposing beam, and rotational beam radiation therapy.

An interactive computer program for calculating treatment times for 60Co single beam, opposing beam, or rotational beam radiation therapy is described. The program allows the user to enter parameters specific to his machine. Analytic expressions are used to represent the depth dose, backscatter factor, tissue-air ratio, collimator factor, and beam attenuation of a block-carrying tray.

Cobalt Radioisotopes↗

A system for checking radiation therapy calculations for treatment time or monitor setting.

Errors in the calculation of radiation therapy treatment time or monitor setting are likely to occur with regularity unless adequate quality control procedures are utilized. These errors can be greatly reduced if appropriate computer systems are employed with programs which utilize analytical representations of dosimetric quantities. A system wherein dosimetry technologists routinely check treatment calculations using a computer terminal has been in operation in our department for several years and has proved helpful in uncovering calculation errors.

Computers↗