PubMed Health⌕ Search

Biomedical subjects

D Gaitini

Publications and source records attributed to D Gaitini.

At least 37 records · Page 2Linked to original sources

Metastatic spinal cord compression as initial presentation of follicular thyroid carcinoma.

Follicular thyroid carcinoma, initially presenting as spinal cord compression due to metastatic lesions, is a less reported event. We present two cases of well-differentiated thyroid carcinoma that led to spinal cord compression. A thorough search of the literature revealed only five similar cases. We summarize the clinical characteristics of these cases, the therapeutic measures used, their outcome, and the prognosis.

Adenocarcinoma, Follicular↗

Benign proliferative lesions mimicking recurrence of Hodgkin's disease.

Salvage treatment in patients with recurrent Hodgkin's disease is more effective when tumor burden is minimal. That is why more intensive follow-up strategies, including frequent imaging tests, have been recently developed for the detection of early relapse. However, as screening procedures become more sensitive, there is an increasing risk of false-positive results, demonstrating nonmalignant proliferative disorders. We describe three young patients who had lymphocyte-predominant or mixed-cellularity Hodgkin's disease and were in clinical complete remission for 2.5-3 years after a combined treatment with chemotherapy and radiation. Imaging tests revealed new gallium-avid lymphadenopathy in the chest in two cases. Pathologically enlarged pelvic lymph nodes were identified in another case, after a diagnosis of recurrent disease in axilla. Those findings were interpreted as relapse, and the patients underwent thoracotomy and laparotomy, respectively, for histologic confirmation. The results showed progressively transformed germinal centers and sarcoid-like lesions, two benign proliferative disorders. When patients with Hodgkin's disease in remission show new lymphadenopathy, even with positive gallium scan, it seems mandatory to obtain tissue for histologic examination, even through invasive procedures such as laparotomy and thoracotomy, to avoid wrong diagnosis and unnecessary treatment.

Adult↗

Pattern analysis of temporal changes in the carotid artery diameter under normal and pathological conditions.

Age-related and temporal cyclic changes in the left and right common carotid arteries (CCA) diameters were studied in two groups of subjects: (i) 11 healthy normotensive subjects (ages 19-72 years), and (ii) eight hypertensive subjects (ages 59-85 years), with various degrees of stenosis in their ICA. Cross-sectional images of the left and right CCA were acquired via an ultrasonic system. Images were digitized, and the contour of the arterial wall for each frame was manually traced. Assuming a circular geometry, the arterial diameter was calculated. Averaging four to six consecutive heart beats yielded the typical patterns of temporal diameter changes for both the left and right CCA. For the group of normal subjects, a typical pattern of the temporal diameter changes with a consistent left vs right peak diameter delay (LRPDD), with the right CCA preceding the left, was observed. Plotting the normalized left vs right CCA diameters yielded a typical loop (DDloop) which changed in the counter-clockwise direction from systole to diastole. For the group of hypertensive subjects, the LRPDD decreased or became negative with the left CCA preceding the right if the stenosis degree exceeded 50% (p < 0.01). The DDloop changed from a counterclockwise to a clockwise direction. For the group of normal subjects, end diastolic, end systolic diameters and the elastic index of the CCA increased with age while the relative systolic change in diameter decreased with age. For the group of hypertensive subjects, the relative systolic change in diameter was smaller, compared to normals (7.8 +/- 1.2% vs 10.7 +/- 3.1%, respectively; p < 0.05). The elastic index for this group was significantly higher compared to the normal subjects (1.4 +/- 0.3 vs 0.6 +/- 0.2 x 10(5) dynes/cm2, respectively; p < 0.001). These findings imply that patterns of CCA temporal diameter changes can indicate the existence of a pathological state.

Adult↗

Utility of gallium-67 scintigraphy in low-grade non-Hodgkin's lymphoma.

PURPOSE: Low-grade non-Hodgkin's lymphoma (LGNHL) has traditionally been considered non-gallium-avid. The sensitivity of gallium 67 (67Ga) scintigraphy when using modern equipment and techniques in patients with LGNHL was investigated. MATERIALS AND METHODS: Fifty-seven consecutive patients with LGNHL underwent 67Ga scintigraphy at initial presentation (n = 40), when tumor progression occurred during treatment (n = 3), and at suspected disease recurrence after continuous clinical remission (CCR) (n = 14). Planar and tomographic images were obtained with either a very large field-of-view or a dual-head digital camera. Of 45 patients with Ga-avid LGNHL, 30 underwent 93 follow-up scans (one to six studies per patient). Scan findings were correlated with clinical and computed tomographic (CT) findings and with patient outcomes. RESULTS: 67Ga scintigraphy was positive in 45 of 57 patients (sensitivity, 79%) and in 113 of 164 disease sites (sensitivity, 69%). The sensitivity was higher in the more common types of LGNHL: follicular, predominantly small cleaved cell (FSC), and follicular, mixed small cleaved and large cell (FM) (84% and 91% in patients and 72% and 71% in disease sites, respectively). Sensitivity was lower in patients with mucosa-associated lymphoid tissue lymphoma (MALT) and small lymphocytic lymphoma (SL). Among 28 patients with disease recurrence after CCR (14 with and 14 without baseline studies), 67Ga scan was positive in 25, for a sensitivity of 89% for detection of disease recurrence. CONCLUSION: When modern technology is used, 67Ga scintigraphy has good sensitivity in patients with LGNHL. It therefore can be used to monitor response to therapy and to provide early detection of disease recurrence in these patients.

Adult↗

Application of a bedside whole blood D-dimer assay in the diagnosis of deep vein thrombosis.

Cross-linked fibrin degradation products have been used to detect venous thrombosis. While the sensitivity of plasma D-dimer measured by ELISA in the diagnosis of deep vein thrombosis (DVT) is high, the utility of ELISA methods is limited in a clinical setting. This study analysed the diagnostic value of a rapid D-dimer assay performed on whole blood samples (SimpliRed D-dimer) compared with latex and ELISA in 86 patients suspected of having DVT. SimpliRed D-dimer was positive in 47/50 of patients with DVT established by Doppler ultrasound (DU; sensitivity 94%). SimpliRed D-dimer was positive in 35/37 of patients with proximal DVT, nine out of nine with popliteal DVT and three out of four with superficial thrombophlebitis. The specificity of SimpliRed D-dimer in the diagnosis of DVT was 61%. The sensitivity of the SimpliRed D-dimer assay was at least comparable with the ELISA (87%) and superior to the latex assay (80%). The positive predictive value (77%), the negative predictive value (88%) and the overall accuracy (80%) of the SimpliRed assay were better than the ELISA and latex methods. It is concluded that SimpliRed D-dimer is a rapid useful assay for screening of patients suspected of having deep vein thrombosis.

Adolescent↗

Doppler ultrasound in the diagnosis of venous thrombosis.

Deep vein thrombosis (DVT) has known morbidity and mortality. New noninvasive techniques such as B-mode scanning and Doppler ultrasonography (duplex) are highly accurate in the diagnosis of this problem but are relatively expensive and time consuming. Continuous-wave Doppler, a precursor noninvasive technique, is simple, cheap, and easy to perform at the patient's bedside. To test the effectiveness of this technique the authors prospectively studied patients with clinical suspicion of DVT by Doppler ultrasound and compared the results with those from venography. During fourteen consecutive months, patients with a clinical suspicion of DVT underwent continuous-wave Doppler examination of both inferior limbs. Each case was diagnosed as positive, negative, or inconclusive. In addition, the patients underwent a questionnaire regarding risk factors, symptoms, and mean relevant physical findings. Doppler examination was blinded to venography results. A total of 116 patients with clinical suspicion of DVT were examined by Doppler ultrasound. Their mean age was fifty-five years (range: eighteen to eighty-eight). There were 57 men and 59 women, and from this group a total of 40 patients underwent both Doppler ultrasound examination and venography in the course of forty-eight consecutive hours. When cases with an inconclusive result were excluded, Doppler ultrasound showed a sensitivity of 89%, a specificity of 100%, and an accuracy of 94% for the diagnosis of DVT when compared with venography. When a similar analysis was done for the proximal named veins, continuous-wave Doppler examination showed a very high specificity and positive predictive value and a moderate sensitivity and negative predictive value.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Single-photon emission computed tomography quantitation of gallium citrate uptake for the differentiation of lymphoma from benign hilar uptake.

PURPOSE: To assess the role of quantitative gallium citrate (Ga 67) single-photon emission computed tomography (SPECT) in differentiating lymphoma from benign hilar uptake, concentrations of Ga 67 in 29 sites of documented lymphoma and in 75 benign lesions were compared. PATIENTS AND METHODS: One hundred seven thoracic Ga 67 SPECT studies obtained in 101 consecutive lymphoma patients were reviewed. Fifty-nine studies detected Ga 67 uptake in the hilar and or mediastinal regions. Forty-eight studies showed no such abnormality. The concentration of Ga 67 in the thoracic lesions was measured using a quantitative SPECT technique and its nature was determined by correlation with computed tomographic (CT) scans and follow-up evaluation of the sites. RESULTS: In 20 of 59 abnormal studies (34%), there was lymphoma in the hilar and or mediastinal regions. In the remaining 39 abnormal studies (66%), Ga 67 uptake was benign. There were 29 sites of lymphoma and 75 benign lesions. The concentration of Ga 67 in lymphoma was significantly higher than in benign hilar uptake (13.2 +/- 5.4 %ID/mL x 10(-3) v 5.6 +/- 1.5 % injected dose (ID)/mL x 10(-3); P < .001). A concentration value of 8.3 %ID/mL x 10(-3) was found to best separate lymphoma and benign uptake, with a sensitivity of 90%, a specificity of 93%, a positive predictive value of 84%, and a negative predictive value of 96%. CONCLUSION: Lymphoma and benign hilar uptake differ significantly in their concentration of Ga 67. The present study shows that quantitative Ga-67 SPECT reliably differentiates lymphoma and benign uptake.

Adolescent↗

Gallium-67 scintigraphy in lymphoma with bone involvement.

UNLABELLED: Both Hodgkin's and non-Hodgkin's lymphoma (NHL) may involve bone. Traditionally, 99mTc-MDP bone scintigraphy has been used to detect such involvement. In recent years, 67Ga scintigraphy has shown to be useful in monitoring treatment response in lymphoma. Although 99mTc-MDP has not been found particularly useful for monitoring bone response to cancer treatment, we were interested in whether 67Ga scintigraphy and SPECT could be used to monitor bone involvement with lymphoma. METHODS: Gallium-67 and 99mTc-MDP uptake were investigated in 20 patients with lymphoma involving the bone before treatment. Gallium-67 scans were done in 16 patients for monitoring response to treatment in the bone lesions. RESULTS: Gallium-67 studies diagnosed bone lesions in 19 of the 20 patients. Technetium-99m-MDP detected bone lesions in all patients investigated. In four patients, uptake by Ga-67 was more intense than 99mTc-MDP and in another four patients 99mTc-MDP uptake was more evident. Gallium-67, however, was useful in detecting other regions of involvement in 18 of the 19 patients with soft-tissue lymphoma lesions. Gallium-67 scintigraphy also correctly monitored bone response to treatment in all but one of the 16 patients who had 67Ga scintigraphy after completing therapy. CONCLUSION: Gallium-67 uptake by lymphoma involving the bone can be used to monitor osseous response to treatment.

Adolescent↗

Image-directed Doppler ultrasound in the diagnosis of lower-limb venous insufficiency.

Ninety-eight legs in 73 patients were evaluated with image-directed Doppler ultrasound for suspected chronic venous insufficiency. Examinations of the entire venous system were performed to determine lumen patency and valvular competence. Reflux during Valsalva maneuver in the femoral and great saphenous vein, and, after release of distal compression in the popliteal vein, indicated valvular incompetence. Twenty limbs had normal veins; Baker's cysts were found in three. Superficial venous insufficiency was found in 25 cases. Deep reflux, either alone or in combination with superficial reflux, was the predominant pathological feature (53 legs). Photoplethysmographic studies of the veins were performed on 24 limbs. Image-directed Doppler ultrasound was more successful in defining the exact site of venous incompetence and in detecting nonvenous pathology. By the combination of real-time imaging of the vein with gated Doppler sonography of flow, image-directed Doppler sonography is becoming the method of choice for the investigation of chronic venous insufficiency.

Adult↗

Gallium-67 uptake in a mass of benign transformation mimicking recurrence of nodular lymphocytic predominance Hodgkin's disease.

Gallium-67 is now widely used in the management of lymphoma patients. It is not, however, tumor-specific and reasons for uptake in nonmalignant and premalignant lesions associated with lymphoma should be recognized. Gallium-67 uptake in a mass of progressively transformed germinal centers and sarcoid-like reaction, mimicking recurrence in a 31-yr-old man with nodular lymphocytic predominance Hodgkin's disease, is described. Gallium-67 was taken up on two occasions and a recurrence was suspected. On the first occasion, abnormal uptake was present in axillary lymph nodes and on the second in mediastinal and parahilar lymph nodes. Histology of the lesions on both occasions showed progressively transformed germinal centers and sarcoid-like reaction but no evidence of Hodgkin's disease (HD). Bilateral parahilar abnormal uptake of 67Ga disappeared spontaneously without treatment after several months. The mass on CT regressed but did not disappear. This case demonstrates that the appearance of a new mass which takes up 67Ga in lymphocytic-predominance HD during a continuous clinical remission does not necessarily indicate recurrence and the need for treatment. It suggests that a biopsy should be performed to determine the nature of the lesion.

Adult↗

Closure of the ductus venosus in neonates: findings on real-time gray-scale, color-flow Doppler, and duplex Doppler sonography.

OBJECTIVE: Our objective was to document the anatomy, flow pattern, and time of closure of the ductus venosus in healthy full-term neonates. SUBJECTS AND METHODS: We examined the ductus venosus in 73 neonates by using gray-scale sonography, color flow imaging, and duplex Doppler sonography. Each neonate was examined 1-2 days after birth, 6-7 days after birth, and then every 3-4 days until closure was confirmed or the neonate was 18 days old. The length, width, and color flow and duplex Doppler characteristics of the ductus were noted. Closure of the ductus at 6-7 days after birth was examined with respect to birth weight, hemoglobin level, and gestational age. RESULTS: The ductus venosus, extending from the left portal vein to the inferior vena cava, was identified with all three techniques. The ductus was patent in all 73 neonates 1-2 days after birth. It was still patent in 41 (68%) of 60 neonates reexamined 6-7 days after birth and in two of three neonates (11% [7/60]) reexamined 17-18 days after birth. Blood flow within the ductus was cephalic, in a constant venous waveform. Initial flow velocity ranged from 0.15 to 0.70 m/sec and decreased consistently in subsequent examinations. There was no significant difference in birth weight, hemoglobin level, or gestational age between the group whose ductus was closed and the group whose ductus was open at 6-7 days after birth. CONCLUSION: The ductus venosus in neonates is consistently detectable on sonography. It is patent in a greater percentage of neonates, and for a longer time, than was previously shown with conventional radiographic studies with angiography.

Blood Flow Velocity↗

Renal extramedullary hematopoiesis simulating hypernephroma.

We report a 63-year-old woman who presented with anemia and a left kidney mass. Guided fine-needle aspiration of the mass revealed extramedullary hematopoiesis and enabled avoiding an unnecessary operation. Subsequent bone marrow biopsy demonstrated myelofibrosis. Twenty-four months later the mass remained stable.

Carcinoma, Renal Cell↗

The value of ultrasound in Schoenlein-Henoch purpura.

We report the results of ultrasound studies on 11 children with Schoenlein-Henoch purpura. In 8 children the ultrasound examination was normal. In two of three patients with macroscopic haematuria, haemorrhagic cystitis, a previously undescribed finding in Schoenlein-Henoch purpura, was found. In one case the gall bladder wall and the wall of several adjacent loops of bowel were markedly thickened. Follow up examinations after clinical recovery demonstrated complete resolution of these abnormalities. Our observations demonstrate that diagnostic ultrasound may have an important role before more expensive and invasive procedures are employed in patients with Schoenlein-Henoch purpura.

Child↗

Late changes in veins after deep venous thrombosis: ultrasonographic findings.

In a prospective trial, 43 patients (45 legs) were re-examined by high resolution and continuous-wave Doppler ultrasonography 3-32 months after an acute episode of deep venous thrombosis (DVT). The veins were abnormal in 31 legs (69%). Abnormal veins were either narrowed with a highly echogenic lumen (thought to represent persistent occlusion) or with a relatively sonolucent lumen and thickened walls (thought to represent recanalized veins). Collateral veins were present. Some compression by probe could be achieved in partially occluded veins, but full collapsibility was absent. Continuous-wave Doppler studies were similar to those in acute DVT. In order to be able to diagnose new episodes of DVT in patients who have had DVT in the past, a baseline ultrasound study should be carried out approximately 6-12 months after an acute episode. In the absence of such a baseline study, contrast phlebography should be resorted to.

Collateral Circulation↗

Duplex sonography in the diagnosis of portal vein thrombosis.

Portal vein thrombosis was readily diagnosed by pulsed duplex Doppler sonography in five patients. The cases represent different stages in the development of the thrombotic event, from partial or complete occlusion by an echogenic intraluminal thrombus to cavernous transformation of the portal vein. The unique ability of duplex scanning to demonstrate abnormal vascular structures and flow pattern is emphasised. This method should be the technique of choice in the diagnosis of portal vein thrombosis.

Aged↗

Acute focal bacterial nephritis: emphasis on imaging.

A case of acute focal bacterial nephritis in a child is presented. Imaging findings for various modalities are discussed (nuclear medicine, ultrasound, computed tomography, and conventional radiology) with a suggestion for optimal imaging strategy in these cases.

Acute Disease↗

[Ultrasonographic diagnosis of deep vein thrombosis of the leg].

142 patients with the clinical diagnosis of deep vein thrombosis (DVT) of the legs were examined by high resolution ultrasound. The deep and superficial femoral and popliteal veins were examined with 6.5 and 10 MHz transducers. 124 of the patients were also examined with continuous wave Doppler ultrasound and in 46 contrast phlebography was performed. The overall accuracy of ultrasound compared to phlebography was 90%. If only the deep femoral vein was considered, ultrasound and phlebography correlated in 100%. The ultrasonographic characteristics of DVT are increased echogenicity of the involved vein, absence of response to the Valsalva maneuver and non-collapsibility of the thrombosed vein on pressing with the transducer probe. High resolution ultrasonography should be the primary tool for the diagnosis of DVT.

Humans↗