Contribution of the endotracheal tube and the upper airway to breathing workload.

The influence of the endotracheal tube (ETT) during a T-piece trial remains controversial. Our aim was to compare the work of breathing of 14 successfully extubated patients at the end of a 2-h trial (T) and after extubation (E) of the trachea, and to assess, using the acoustic reflection method, the resistance of the endotracheal tube and of the supraglottic airway as well as their related work. We found that the work of breathing of the patients was identical between T and E (1.72 +/- 0.59 versus 1.63 +/- 0.45 J/L; p = 0.50 and 23.5 +/- 10.6 versus 22.6 +/- 9.7 J/min; p = 0.70). There was no significant difference between the beginning and the end of the T-piece trial (1.57 +/- 0.53 versus 1.72 +/- 0.59 J/ L, p = 0.10). The work caused by the ETT amounted to 11.0 +/- 3.9% of the total work of breathing. The supraglottic airway resistance was in the normal range and was significantly smaller than the endotracheal tube resistance (0.79 +/- 0.4 versus 1.43 +/- 0.31 cm H2O x s/L; p = 0.008, flow = 0.25 L/s). We conclude that a 2-h trial of spontaneous breathing through an endotracheal tube well mimics the work of breathing performed after extubation, in patients who pass a weaning trial and do not require reintubation.

Acoustics↗

Effects of flow triggering on breathing effort during partial ventilatory support.

The effects of flow triggering (FT) as compared with pressure triggering (PT) on breathing effort have been the focus of several studies, and discrepant results have been reported. In the initial part of our study, a lung model was used to quantify triggering effort (airway pressure-time product, PTPaw) for a range of sensitivity settings in nine new-generation ventilators. A ventilator providing both FT and PT was then used to compare these systems during pressure-support (PSV) and volume-targeted assist-control ventilation (ACV) in eight ventilator-dependent patients, using sensitivity settings (2 L/min for FT and -2 cm H2O for PT) that had proven significantly different in the initial bench study. Indexes of effort included the esophageal and transdiaphragmatic pressure-time products and inspiratory work of breathing per minute (PTPes/min, PTPdi/min, and Wi/min, respectively). The experimental study revealed significant differences between ventilators in PTPaw at commonly used settings. In two of three ventilators featuring both systems, PTPaw was significantly lower with FT than PT (p < 0.001). In the clinical study, FT as compared with PT, was associated with reductions in all indexes of breathing effort during PSV: 16 +/- 6% (p < 0.001), 13 +/- 10% (p < 0.01), and 14 +/- 12% (p < 0.05) for PTPdi/min, PTPes/min, and Wi/min, respectively. By contrast, no differences were found when FT was used during ACV. Although FT reduced triggering effort in both modes (p < 0.001), the effects observed during the post-trigger phase differed, and explained the discrepant results between the two modes. We conclude that FT more effectively reduces breathing effort when used in conjunction with a pressure-targeted mode than with a volume-targeted mode, especially when flow delivery is close to or below demand.

Aged↗

Expiratory valves used for home devices: experimental and clinical comparison.

A bench study followed by a clinical trial were performed to evaluate the mechanical characteristics of five (commercially available) expiratory valves used for home ventilators, as well as the potential clinical impact of differences between these valves. In the in vitro study, expiratory valve resistance was evaluated under unvarying conditions, whereas dynamic behaviour was evaluated by calculating the imposed expiratory work of breathing during a simulated breath generated by a lung model. Differences in resistance and imposed expiratory work of up to twofold and 150%, respectively, were found across valves. We then conducted a randomized crossover clinical study to compare the effects of the least resistive (Bennett) and most resistive expiratory valves (Peters) in 10 intubated patients receiving pressure support ventilation. There were no significant differences regarding blood gases or respiratory parameters except for the oesophageal pressure-time product (PTPoes), which was significantly increased by the Peters valve (236+/-113 cmH2O x s x min(-1) versus 194+/-90 cmH2O x s x min(-1)). An analysis of individual responses found that the Peters valve induced substantial increases in intrinsic positive end-expiratory pressure (PEEP), PTPoes, and expiratory activity in those patients with the greatest ventilatory demand. In conclusion, differences between home expiratory valve resistances may have a clinically relevant impact on the respiratory effort of patients with a high ventilatory demand.

Adult↗

Interaction between steady flow and individualised compliant segments: application to upper airways.

To describe upper airway obstruction in patients with sleep apnea syndrome, the steady state solutions of a simple model of local pharyngeal obstruction were studied. Importantly, the present model embodies a series of two individualised elements, each having its own compliance, which enables the consideration, from a conceptual point of view, of local differences in anatomical and physiological properties between pharyngeal regions. The evolution of inspiratory flow and area variations were predicted using the transmural pressure at the downstream element as the controlled variable. Derivation and normalisation of fundamental governing equations, written for non-viscous and viscous fluids, reveal very different kinds of behaviour, depending on values of the speed index defined from the local distensibility, or its modulation by a friction factor for viscous fluid. The two-element model is able to describe a considerably rich mechanical behaviour, including the occurrence of critical conditions when area becomes very high or small, i.e. when the distensibility-dependent speed index at the upstream element tends toward unity. In spite of its simplicity, not only does the present model describe steady state behaviours that resemble the well-known phenomenon of choking in an elastic tube, but the viscous fluid conditions also reveal (i) an area evolution following a typical doubly folded shape, (ii) the occurrence of a close succession maximum and minimum flows which can be seen as a physiological 'flow plateau'. It is concluded that the concept of interaction behind the two-element model must be considered as soon as flow interacts in a compliant structure characterised by anatomical and/or functional singularities.

Airway Obstruction↗

Assessment of high-frequency neonatal ventilator performances.

OBJECTIVE: To assess the efficacy and reliability of neonatal high-frequency ventilators. DESIGN: Bench evaluation of neonatal high-frequency ventilators. SETTING: Physiology department and university hospital neonatal intensive care unit. INTERVENTIONS: HFV-Babylog 8000 (Dräger Medical), OHF 1 (Dufour), and SensorMedics 3100A (Sensor-Medics) ventilators were connected to a neonatal test-lung. Tidal volume, peak-to-peak pressure amplitude, and mean airway pressure were measured for several ventilator settings, endotracheal tube sizes, and lung compliances. MEASUREMENTS AND RESULTS: Increasing peak-to-peak pressure resulted in a linear increase in tidal volume delivery in the 0-30% range of maximum amplitude. No significant increase in tidal volume was observed with the HFV-Babylog 8000 when pressure amplitude was above 50%. The maximum tidal volume delivered was substantially smaller with the HFV-Babylog 8000 than with the OHF 1 or SensorMedics 3100A. Tidal volume increased with endotracheal tube size with all three ventilators. Increasing test-lung compliance resulted in lower tidal volumes only with OHF 1. Decreasing mean airway pressure was responsible for a decrease in tidal volume delivery with HFV-Baby-log 8000. CONCLUSION: We found that under our test conditions two of the three ventilators delivered adequate tidal volumes at the usual frequency of 15 Hz, regardless of the size of the endotracheal tube and of the mechanical properties of the respiratory system. When lung compliance increased or mean airway pressure decreased, both of which are common events during the recovery phase of hyaline membrane disease, we found that the intrinsic properties of two of the ventilators tested were responsible for a decrease in tidal volume. This decrease may account for some cases of heretofore unexplained hypercapnia.

Critical Care↗

Carbon dioxide respiratory response during positive inspiratory pressure in COPD patients.

The aim of this study was to compare the effect of inspiratory pressure support (IPS) on the respiratory CO2 response in 13 stable COPD patients and in 13 normal subjects. Without IPS, the slopes of the ventilatory response to CO2 were lower in the patients than in the normal subjects (mean +/- SEM, 0.82 +/- 0.19 vs. 1.69 +/- 0.31 l.min-1.mmHg-1). When IPS was applied, both groups showed, at any level of end-tidal CO2 pressure, an increase in ventilation due to an increase in tidal volume (VT) associated with a decrease in occlusion pressure (P0.1). In addition, respiratory parameters (VE, VT, P0.1, inspiratory flow) were insensitive to CO2 as long as PETCO2 remained below a threshold which was slightly above the eupneic value. However, above this CO2-threshold, no differences in slopes were observed between the IPS and control conditions in either group, except for a decrease in the P0.1 slope during IPS in the COPD patients. In conclusion, IPS induced similar respiratory changes during CO2 response in stable COPD patients and in normal subjects. Above the eupneic value, IPS did not change the slope of the ventilatory response to CO2.

Adult↗

Effect of gas density variations on respiratory input impedance in humans.

The forced oscillation technique is a widely-used non-invasive method of characterizing the dynamic behaviour of the respiratory system. We used the forced oscillation technique to investigate respiratory mechanics in healthy subjects during simulated dives in dry hyperbaric chambers. We observed frequency dependence of input impedance, which was mainly density-dependent. To explain this result, we propose a model of the respiratory system, based on flow redistribution in a two-pathway circuit. This model, using the electrical analogue, is composed of two Resistance-Self Inductance-Capacitance (R-I-C) pathways set up in parallel. It allowed us to explain the dynamic behaviour of respiratory impedance under hyperbaric conditions in healthy subjects. Changes in respiratory impedance according to frequency vary with the relative importance of the inequalities of the two time constants RC and I/R between the two pathways. With low values of density, RC inequality predominates, whereas I/R inequality tends to predominate with high values of density.

Air Pressure↗

Noninvasive estimate of work of breathing due to the endotracheal tube.

BACKGROUND: Although evidence suggests that secretions lining the inner wall of the endotracheal tube (ETT) often reduce its cross-sectional area, no data are available on the work of breathing as affected by the ETT. A noninvasive method is proposed for estimating the additional work of breathing necessitated by the ETT in patients whose lungs are mechanically ventilated. This method (the acoustic-Blasius method) involves (1) determining the inner geometry of the ETT using the acoustic reflection method and (2) using these geometric data to solve the Blasius equation that characterizes the ETT pressure drop-flow relation. METHODS: To evaluate the acoustic-Blasius method in vivo, the authors computed the work of breathing due to the ETT in four healthy persons breathing through an ETT connected to a pressure-support device and in five tracheally intubated patients receiving mechanical assistance in the pressure-support mode. For the tracheally intubated patients, the reference value was the work calculated from the ETT pressure drop measured between the two ends of the ETT using a pressure catheter. RESULTS: In the healthy participants and the tracheally intubated patients, there was close agreement between inspiratory work per cycle values estimated by directly measuring the ETT pressure drop and calculated using the acoustic-Blasius method: The difference was consistently less than 0.08 joules (< 10% of the reference value). CONCLUSIONS: The data show that the acoustic-Blasius method allows noninvasive quantification of the ETT-related work of breathing in situ.

Humans↗

Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices.

BACKGROUND: Limited data suggest that increased resistance to flow within endotracheal tubes (ETT) may occur in patients whose lungs are mechanically ventilated for more than 48 h, especially when airway humidification is inadequate. This could lead to sudden ETT obstruction or induce excessive loading during spontaneous breathing. METHODS: Twenty-three such patients were randomly assigned to three types of airway humidifier based on three different working principles: a Fisher Paykell hot water system (n = 7), a Pall BB2215 heat and moisture exchanger (HME) hydrophobic filter (n = 8), and a Dar Hygrobac 35254111 HME hygroscopic filter (n = 8). The decrease in internal pressure along the ETT and the flow rate were measured in each patient every 2 days. An "effective inner diameter" was derived from these measurements and allowed the inner ETT configuration to be monitored. RESULTS: On the first day of intubation, the mean diameter was similar in the three groups, and was slightly smaller than the in vitro diameter (mean +/- SD: 7.6 +/- 0.6 mm for Fisher-Paykell, 7.7 +/- 0.4 for Pall, and 7.5 +/- 0.4 for Dar). The mean diameter tended to decrease from day to day. At the end of the study, the overall reduction in mean diameter was significantly greater with the hydrophobic HME (Pall) than with the two other systems (Pall: -6.5 +/- 4% vs. 2.5 +/- 2.5% for Dar and 1.5 +/- 3% for Fisher-Paykell; P < 0.01 with analysis of variance). The same was true of the mean reduction in effective inner ETT diameter expressed per day of ventilation (-1.6 +/- 1.5% per day for Pall vs. -0.5 +/- 0.4% for Dar and -0.2 +/- 0.4% for Fisher-Paykell; P < 0.01). In four patients, the ETT became obstructed and emergency repeated tracheal intubation was required. The Pall HME and the Fisher-Paykell system were being used in three and one patient, respectively. Before obstruction, the reduction in ETT diameter was significantly greater for these four patients than for the remaining 23 patients (7.8 +/- 1.4% vs. 3.1 +/- 4.1%; P < 0.01). CONCLUSIONS: During prolonged mechanical ventilation, significant alterations in inner ETT configuration occur frequently and are influenced by the type of humidification device used. In vivo monitoring of ETT mechanical properties might be clinically useful.

Aged↗

Home versus intensive care pressure support devices. Experimental and clinical comparison.

A bench study using an artificial lung model and a clinical study in patients were performed to evaluate six commercially available home pressure support devices. Six devices were tested in the in vitro study, including five designed for home use and one designed for use in intensive care units. Minimal positive end-expiratory pressure (PEEP) varied across home devices, from 0.5 cm H2O to 4.3 cm H2O. Work imposed during exhalation varied up to six-fold across devices. A substantial rebreathing volume has present for the three home devices with a common inspiratory and expiratory line. This rebreathing volume decreased with increasing PEEP level, as expected, but remained substantial at the widely used PEEP level of 5 cm H2O. Use of a non-rebreathing valve increased both the work imposed by the circuit during the exhalation phase and the time required to attain the relaxation equilibrium. Except for two home devices and a bilevel positive airway pressure (BiPAP) device equipped with a non-rebreathing valve, differences in inspiratory trigger sensitivities were small between home and intensive care devices. During pressure support, the total work performed by the machines did not differ by more than 15% between devices, whereas differences of more than 300% were observed in flow acceleration. Only one home device gave a flow acceleration similar to or better than that obtained with the intensive care device. In a randomized, crossover clinical study, we compared a home device to a device specially designed for intensive care use in seven intubated patients during weaning from mechanical ventilation. The main differences between the two devices were trigger sensitivity and initial flow acceleration. For the same level of pressure support, there were no significant differences in arterial PCO2, tidal volume, respiratory rate, or minute ventilation between these two devices. However, the esophageal pressure-time product was 30% higher with the home device (165 +/- 93 versus 119 +/- 80 cm H2O/min, p < 0.05). In conclusion, differences exist between devices in terms of occurrence of rebreathing, speed of attainment of stable pressure support level, and expiratory resistance. These differences characterizing the delivery of pressure support may have clinical impact on the inspiratory effort of patients.

Adult↗

Efficacy of cardiopulmonary resuscitation using intratracheal insufflation.

The effects of constant-flow insufflation (CFI) of air in the trachea at the distal end of a modified endotracheal tube as the sole mode of ventilation during cardiopulmonary resuscitation (CPR) were studied in pigs. The ventilatory effect of CFI (15 +/- 2 L/min) generating a positive pressure of about 10 cm H2O with concomitant chest compression was studied first. In nine sedated, paralyzed animals disconnected from the ventilator, CFI alone did not significantly alter the decrease in PaO2 and the rise in PaCO2 observed during apnea. By contrast, the combination of precordial compression and CFI (CFI-CPR) maintained arterial blood gases over a 4-min period at the level obtained during mechanical ventilation. In the second part of the study, ventricular fibrillation was induced and CFI-CPR was compared with standard CPR using conventional mechanical ventilation during two successive 4-min periods, in random order. Ventilatory parameters were identical in the two situations, whereas hemodynamic parameters were similar or better with CFI-CPR than with standard CPR. Significant differences were observed between standard CPR and CFI-CPR for systolic aortic pressure (72 +/- 22 versus 82 +/- 27 mm Hg, respectively; p < 0.02) and for systolic (322 +/- 216 versus 431 +/- 237 ml/s; p < 0.01) and mean (116 +/- 106 versus 143 +/- 108 ml/s; p < 0.01) common carotid blood flows. The ease of use of CFI together with its beneficial hemodynamic effects suggests that CFI deserves to be investigated further as a mode of ventilation during CPR.

Animals↗

Comparative effects of pressure support ventilation and intermittent positive pressure breathing (IPPB) in non-intubated healthy subjects.

We compared the efficacy of three devices delivering assisted non-invasive ventilation with different working mechanisms, during room air breathing and during CO2-induced hyperventilation. In seven healthy volunteers, breathing pattern, respiratory muscle activity and comfort were assessed: during unassisted spontaneous breathing through a mouth-piece (SB); during assisted breathing with a device delivering inspiratory pressure support (IPS); and with two devices delivering intermittent positive pressure breathing (IPPB), the Monaghan 505 (IPPB1), and the CPU 1 ventilator (IPPB2). All three devices were set at 10 cmH2O of maximal pressure. During room air breathing, the work of breathing expressed as power, was significantly greater with the two IPPB devices than with the two other modes (IPPB1 and IPPB2 7.3 +/- 5.2 and 7.2 +/- 6.2 J.min-1, respectively, versus SB and IPS 2.4 +/- 0.7 and 2.3 +/- 3.3 J.min-1, respectively). The difference did not reach the statistical significance for the pressure-time product (PTP). Discomfort was also greater during the IPPB modes. During CO2-induced hyperventilation, considerable differences in power of breathing were found between the two IPPB devices and the other two modes. The PTP was also much higher with IPPB. Transdiaphragmatic pressure was significantly smaller during IPS than during the three other modes (IPS 18 +/- 2.6 cmH2O versus SB 22 +/- 2.6, IPPB1 32 +/- 5.2, and IPPB2: 28 +/- 5.2). Maximal discomfort was observed during the IPPB modes and was correlated with the magnitude of transdiaphragmatic pressure (r = 0.60). Despite similarities in their operational principles, IPS and IPPB had very different effects on respiratory muscle activity in healthy non-intubated subjects. IPPB machines not only failed to reduce patient's effort but also induced a significant level of extra work by comparison to spontaneous ventilation at ambient pressure. Great caution is, therefore, needed in the use of patient-triggered devices for non-intubated patients with acute respiratory failure.

Adult↗

Evaluation of carbon dioxide rebreathing during pressure support ventilation with airway management system (BiPAP) devices.

The purpose of this study was to evaluate whether carbon dioxide (CO2) rebreathing occurs in acute respiratory failure patients ventilated using the standard airway management system (BiPAP pressure support ventilator; Respironics; Murrysville, Pa) with positive inspiratory airway pressure and a minimal level of positive end-expiratory pressure (PEEP) and whether any CO2 rebreathing may be efficiently prevented by the addition of a nonrebreathing valve to the BiPAP system circuit. In the first part of the study, the standard device was tested on a lung model with a nonrebreathing valve (BiPAP-NRV) and with the usual Whisper Swivel connector (BiPAP-uc). With the BiPAP-uc device, the resident volume of expired air in the inspiratory circuit at the end of expiration (RVEA) was 55% of the tidal volume (VT) when the inspiratory pressure was 10 cm H2O and the frequency was at 15 cycles per minute. The BiPAP-NRV device efficiently prevented CO2 rebreathing but resulted in a slight decrease in VT, which was due to a significant increase in external PEEP (2.4 vs 1.3 cm H2O) caused by the additional expiratory valve resistance. For similar reasons, both the pressure swing necessary to trigger pressure support and the imposed expiratory work were increased in the lung model when the nonrebreathing valve was used. In the second part of the study, seven patients weaned from mechanical ventilation were investigated using a randomized crossover design to compare three situations: pressure support ventilation with a conventional intensive care ventilator (CIPS), BiPAP system use, and BiPAP-NRV. When we compared the BiPAP system use with the other two systems, we observed no significant effect on blood gases but found significant increases in VT, minute ventilation, and work of breathing. These findings are experimental and are clinical evidence that significant CO2 rebreathing occurs with the standard BiPAP system. This drawback can be overcome by using a non-rebreathing valve, but only at the expense of greater expiratory resistance.

Adult↗

[Non-invasive ventilation in acute respiratory insufficiency in chronic obstructive bronchopneumopathy].

At the time of acute exacerbations of chronic airflow obstruction (BPCO) non-invasive ventilation represents an alternative to endotracheal intubation. In patients with respiratory distress, the use of a face mask is often preferable to a nasal mask alone, by avoiding the escape of oxygen which occurs around the mouth in nasal ventilation. The inspiratory aid is a type of ventilation which permits good synchronisation with the spontaneous activity of the patient; it leads to a reduction of respiratory effort developed by the patient and at the same time improves oxygenation and alveolar ventilation. In a recent randomised multicentre trial in 85 BPCO patients with severe respiratory distress, the level of intubation was reduced from 74 to 26 per cent by ventilation with an inspiratory mask. The consequences were a significant reduction of the complications of acute respiratory failure which were linked to artificial ventilation (p < 0.05) with a reduction of the hospital stay (p < 0.05) and finally a significant reduction in mortality (29 per cent - 9 per cent, p < 0.005). From now on, this technique could be used in many centres as the first treatment in acute exacerbations of BPCO patients to avoid the use of endotracheal intubation.

Acute Disease↗

Respiratory response to inhaled CO2 during positive inspiratory pressure in humans.

To investigate ventilatory CO2 sensitivity during inspiratory pressure support (IPS), we administered inspiratory CO2 [fractional concn (FICO2) 0.01, 0.03, or 0.05] in eight normal subjects without (CTRL) or with (Pinsp) positive inspiratory airway pressure (5 or 10 cmH2O). At CTRL and low IPS, CO2 inhalation led to a significant increase in tidal volume (VT) with nearly identical slopes in the plot of VT vs. end-tidal PCO2. At the high IPS level, VT at FICO2 of 0 was significantly above the value at lower Pinsp and did not increase with CO2 unless FICO2 was elevated to > 0.03. There was very little effect of either Pinsp or FICO2 on respiratory frequency and respiratory timing. The data suggest that the CO2 sensitivity of ventilation is similar at low levels of IPS as during CTRL. However, at high levels of IPS, VT is determined largely by the passive inflation and, thus, independent of CO2. CO2 has to be elevated to increase the respiratory drive before VT becomes CO2 sensitive.

Administration, Inhalation↗

Acoustic method to estimate the longitudinal area profile of endotracheal tubes.

A problem in mechanical ventilation is the accumulation of mucus secretions in the endotracheal tube (ETT), which tends to reduce the patent cross-sectional area. Here we characterized the extent and locus of the ETT obstruction using an acoustic reflection method recently modified to be applied at bedside. Experiments were conducted both in vivo in 10 intubated patients and in vitro in ETT with or without known constrictions of 1 to 3 mm over 5 cm, located at various distances from the ETT entry: 5, 10, 15, and 20 cm. Acoustic results were compared with the results obtained by an hydraulic reference method, which was the only method available to measure ETT obstruction in mechanically ventilated patients. In vivo acoustic results showed that area reductions were maximal near the tracheal extremity of the ETT, with a range from 2 to 36% (mean value 13 +/- 10%), when estimated relative to the area measured in an unused ETT of the same inner diameter (7 to 9 mm). Statistical analysis of the differences between acoustic reflection data and hydraulic data showed that the two methods did not differ significantly. In vitro acoustic results obtained in constricted ETT showed a highly significant correlation with the actual area (r = 0.97, p = 0.0001). Thus, reductions in ETT area may be detected, quantified, and located by the present acoustic reflection method, which therefore provides a means to avoid emergency extubation because of ETT obstruction.

Acoustics↗

Do turbines with servo-controlled speed improve continuous positive airway pressure generation?

Nasal continuous positive airway pressure (CPAP) devices with a servo-mechanism to control pressure have recently been developed. We evaluated six such devices and three conventional systems in terms of effectiveness in maintaining constant pressure. Machines were tested with pressure levels of 5, 10 and 15 cmH2O. Dynamic behaviour was evaluated: 1) by calculating the imposed work of breathing during simulated breath generated by a sinusoidal pump; and 2) by following the fall in pressure after a transient flow of 1 l.s-1. Quasi-static behaviour was evaluated by simulating a predetermined air leak. Under dynamic conditions, work of breathing was lowest with one conventional nasal CPAP device and three servo-controlled nasal CPAP devices; whereas, the highest levels of work of breathing were recorded with two servo-controlled nasal CPAP devices. The pressure-time response to a transient flow yielded similar results, with a significant inverse correlation between pressure values observed after 300 ms and imposed work of breathing during simulated breathing (r = -0.91). Under quasi-static conditions, microprocessor servo-controlled devices exhibited the best performance. These results suggest that microprocessor servo-controlled nasal CPAP devices are not always the best systems for maintaining constant airway pressure in dynamic situations. However, they are more effective in ensuring maintenance of the desired pressure in the event of an air leak at the mask.

Equipment Design↗

High-frequency ventilation in newborn lambs after intra-uterine creation of diaphragmatic hernia.

Infants with congenital diaphragmatic hernia (CDH) die, because their lungs are hypoplastic and their pulmonary vascular resistance remains elevated after birth. In human newborns, it is difficult to appreciate the benefit of new therapeutic approaches, because the pathological findings are not uniform, the disease is rare and the clinical criteria for poor prognosis with conventional therapy are uncertain. To study the benefit of high-frequency ventilation (HFV) the use of Tolazoline in CDH, we created a diaphragmatic defect in sheep fetuses at 0.6 gestation and studied full-term newborns after a caesarian section. A sternotomy was performed to place catheters and flow probes on the aorta and pulmonary artery and to clamp the ductus arteriosus and the left pulmonary artery. Twins were used as control, and the CDH lambs were either ventilated with conventional ventilation (CV) or HFV. 23 ewes were operated upon with a 22% abortion rate and 31 newborn lambs (10 controls and 21 CDH) were studied. A complete gasometric and hemodynamic study was performed in 23 lambs (7 controls, 8 CDH with CV and 8 CDH with HFV). Clinical and pathological findings of the lambs with CDH were very similar to severe CDH in humans with bilateral lung hypoplasia, severe respiratory distress, high pulmonary vascular resistance and severe hypoxemia. HFV dramatically improved CO2 elimination, allowed less aggressive ventilation, and was associated with higher flows and lower systemic and pulmonary vascular resistance. However, HFV did not improve oxygenation leaving the newborn with severe hypoxemia associated with massive intrapulmonary foramen ovale shunting from right to left.