Interaction of oscillatory and steady turbulent flows in airway tubes during impedance measurement.

Measurement of input respiratory impedance is carried out by superimposing forced oscillations on spontaneous breathing. The latter thus acts as a quasi-steady unidirectional flow component, with effects on the measured impedance that are habitually neglected (linearity assumption). We examined the validity of that assumption in the case of a turbulent steady flow. We tested the validity of a fluid dynamics criterion previously proposed in water channel experiments for gas flow in a tube. This criterion states that oscillatory and continuous turbulent flow may or may not interact if the Stokes boundary layer (ls) is embedded within the viscous sublayer (lv), i.e., if lS+ = lS/lv < or = 10, implying Re7/8 < or = (100 alpha/square root of 2), for a fully developed hydraulically smooth turbulent flow in a tube (where alpha is Womersley parameter and Re is Reynolds number of the steady-flow component). Experiments were performed in long rigid circular and semicircular tubes by superimposing two independent well-defined flows: 1) laminar oscillatory flow obeying the linear transmission line model (frequency = 1.5-250 Hz, i.e., alpha = 6-80) and 2) fully developed turbulent flow characterized by Blasius resistance formula (Re = 3,000-16,000). Confirming the validity of the criterion above, we found that the real and the imaginary parts of the long-tube impedance did not differ from those measured in the absence of a steady-flow component, provided lS+ < or = 10. On the contrary, the real parts measured with and without the continuous component differed greatly as soon as lS+ > 10, both for circular and semicircular tubes and for outward as well as inward steady flows. We concluded that the proposed criterion is pertinent for predicting appropriate oscillation frequency for a given rate of spontaneous flow, such that oscillatory and turbulent flows do not interact. Application of the forced oscillation measurement technique during spontaneous breathing requires use of a range of oscillatory frequencies higher than the frequency range classically used during apnea.

Air Movements↗

Assessment of the respiratory compliance in awake subjects using pressure support.

Pressure support (PS), a new mode of ventilatory assistance, is known to induce respiratory muscle relaxation. It was used to obtain reliable measurements of the compliance of the respiratory system (Crs) in awake subjects. PS was applied, through a mouthpiece, at four successive levels (0, 0.75, 1 and 1.25 kPa) to 30 healthy subjects. At the highest PS level, the subject's relaxation was obtained as assessed by a decrease in the occlusion pressure from 0.10 +/- 0.06 to 0.05 +/- 0.04 kPa, whereas the minute ventilation increased (from 7.5 +/- 1.5 to 13.8 +/- 3.3 l.min-1), and the end-tidal carbon dioxide tension (PCO2) decreased (from 5.0 +/- 0.4 to 3.2 +/- 0.5 kPa) below its apnoea threshold. In three subjects, respiratory muscle relaxation was confirmed by a fall in diaphragmatic electromyographic activity. Crs was calculated as the ratio of the tidal volume to the corresponding end-inspiratory airway pressure (i.e. PS level) since, at end inspiration, a zero-flow period was obtained. Crs was highly correlated (r = 0.77) to the height (Ht) of the subjects: Crs (l.kPa-1) = 3.56 x Ht (m) -4.86 (+/- 0.23), allowing normal values to be determined. In order to evaluate the applicability of the method to patients, Crs was measured in four patients with scoliosis, and was found to range from 45-82% of the predicted values. It is suggested that this simple method of Crs determination may be used to characterize various chest wall or pulmonary diseases.

Adult↗

Respiratory response to positive and negative inspiratory pressure in humans.

To investigate the effect of positive or negative inspiratory pressure on respiration, eight subjects breathed, either without or with added external dead space (VD, 600 ml), through either added inspiratory laminar flow resistances (RES; peak inspiratory airway pressure, Pinsp, down to -9 cmH2O) or with inspiratory pressure support (IPS; Pinsp up to +10 cmH2O). IPS, triggered by the subject's inspiratory effort, provided positive airway pressure throughout inspiration, but allowed for attainment of the subject's own respiratory pattern. The following main results were obtained with IPS or RES relative to the control (no IPS, no RES): (1) with VD, IPS led to small, but significant, increases in tidal volume (VT), respiratory frequency (fR) and ventilation (VE), with no changes in inspiratory time (TI) or duty cycle (TI/TT). Mean inspiratory flow (VT/TI) increased, and mouth occlusion pressure 0.1 sec after onset of inspiration (P0.1) decreased significantly with IPS. The changes during RES were essentially in the opposite direction; (2) without VD, similar, but smaller effects were observed, and only the changes in VT/TI and P0.1 during IPS were significant; (3) highly significant decreases were observed during IPS in end-tidal PCO2 (PETCO2); on the average from 39.6 to 29.2 Torr without VD, and from 45.7 to 39.3 Torr with VD breathing. A small, but significant decrease in PETCO2 occurred also during RES with VD. We conclude that while resistive loading is nearly completely compensated with but small changes in PETCO2, inspiratory pressure support leads to marked hyperventilation, which is not effectively counteracted by central timing commands.

Adult↗

Airway anesthesia during positive and negative inspiratory pressure breathing in man.

We have measured the effects of airway anesthesia (aerosolized 5% lidocaine) on the respiratory pattern during positive or negative inspiratory pressure in 8 resting subjects. The subjects breathed through a 600 ml dead space (peak inspiratory airway pressure, Paw = -2 cmH2O) without or with negative (approx. -5 or -10 cmH2O) or positive (approx. +5 or +10 cmH2O) inspiratory pressure, provided by a laminar flow resistance or a positive pressure source, respectively. Control measurements were performed before and after measurements with airway anesthesia. Measurements included tidal volume, respiratory frequency, ventilation, inspiratory and expiratory duration, occlusion pressure (P0.1) and end-tidal PCO2. None of the parameters measured was significantly altered by airway anesthesia, which was effective in suppressing the cough reflex. We conclude that information from lung afferents that are suppressed with the elimination of the cough reflex is not important for the breathing pattern during resting ventilation with elevated tidal volume (dead space load) and with positive or negative inspiratory pressure.

Adult↗

Use of the Blasius resistance formula to estimate the effective diameter of endotracheal tubes.

To early detect mucus deposition in endotracheal tubes (ETT), we propose using a geometric, flow-independent parameter, i.e., diameter of the ETT, based on a precise knowledge of ETT flow regime, instead of using the classic flow-dependent ETT resistance based on the empirical, nonlinear Rohrer equation. From the estimated slope of -0.24 derived from Moody diagrams characterizing the pressure-flow relationship in ETT of various inner diameters (D), we first assessed that the Blasius resistance formula slope of -0.25 could be applied to adult-size ETT, meaning that flow remains fully developed, turbulent, and hydraulically smooth (0.5 L/s less than or equal to V less than or equal to 1.4 L/s). Insertion into the ETT of a pressure catheter (external diameter: d) to stimulate in vivo measurements did not modify these results, provided the hydraulic diameter, D* = D - d, was substituted for D in the Blasius formula. The Blasius formula was then used to determine, from in vitro pressure and flow measurements in ETT before intubation and in ETT lined with dry mucus secretions, the effective diameter, shown here to be highly correlated to the actual diameter measured by volumetric water displacement. The effective ETT diameter was measured in eight patients at different stages after oral or nasal intubation. Compared with the actual ETT diameter measured before insertion, the effective diameter was slightly reduced (2.6 +/- 2.5%) during the first week of intubation and was strongly reduced (12.2 +/- 2.8%) during the second week.(ABSTRACT TRUNCATED AT 250 WORDS)

Humans↗

Pressure support ventilation using a new tracheal gas injection tube.

In order to explore new types of jet ventilation, we tested a tracheal gas injection tube (TGIT) which included six thin capillaries and provided high pressure injection. The driving pressure was chosen to yield a plateau of inspiratory tracheal pressure of 10 cm H2O. An original controller was built to monitor spirometry and trigger injection in order to deliver both pressure controlled ventilation (PCVTGIT) and a new mode of inspiratory pressure support jet ventilation (IPSTGIT). The PVCTGIT mode maintained the same end-tidal carbon dioxide concentration as conventional ventilation with the same tidal and minute ventilation. We studied 10 patients after abdominal surgery. During spontaneous breathing, the patients were allowed to breathe through the tube, successively with and without IPSTGIT. IPSTGIT, compared with spontaneous breathing increased minute ventilation (from 5.7 (SD 1.6) to 7.1 (1.7) litre min-1) (P less than 0.001). It reduced the total work of breathing (from 0.625 (0.223) to 0.263 (0.151) J litre-1, respectively) (P less than 0.01) and the occlusion pressure (from 2.62 (1.28) to 1.36 (0.74) cm H2O, respectively) (P less than 0.01). It is concluded that this TGIT used with a specific system for sensing and triggering ventilation allows inspiratory pressure support during low frequency jet ventilation.

Female↗

Shunt effect of gas compression inside pneumotachographs during forced oscillations.

Determination of the frequency response of pneumotachographs is needed whenever they are used to measure high-frequency flows, such as in the forced oscillation method. When screen and capillary pneumotachographs are calibrated using an adiabatic compression in a closed box as a reference impedance, they can be adequately described by a series of inertial-resistive elements. However, this type of reference impedance strongly differs from the actual respiratory impedance (ZL). We studied the frequency response of pneumotachographs up to 250 Hz in reference to the impedance of a compressible gas oscillating in a long tube, taken as a more generalizable model of actual ZL. We found that, with this device, the series resistance-inertance models fail to describe the frequency response of the pneumotachograph. However, when compressible effects in the pneumotachograph are taken into account by adding to the resistive models a compliance (Cpn) corresponding to the compression in half of the inner volume of the pneumotachograph, the agreement with experiments becomes satisfactory. Gas compression-related phenomena were demonstrated to be negligible only when the parameter omega Cpn magnitude of ZL is much smaller than 1 (omega pulsation). Results obtained in normal humans have shown that such a correction is required above 100 Hz. Similar correction at lower frequency might also be necessary in cases of large respiratory impedance (e.g., babies, subjects with pathological lungs, and intubated subjects).

Humans↗

Constant-flow insufflation prevents arterial oxygen desaturation during endotracheal suctioning.

In mechanically ventilated patients, disconnection from the ventilator and endotracheal suctioning can induce major arterial oxygen desaturation resulting from apnea, changes in inspired oxygen fraction, and decrease in lung volume. The aim of this study was to test the efficacy of a simple method of delivering oxygen and maintaining lung volume during this process. Our study was conducted in two parts. In the first part, constant-flow insufflation of oxygen (CFI) was used in seven patients ventilated for acute respiratory failure (PaO2/FlO2 = 347 +/- 33 mm Hg) as a means of maintaining arterial oxygenation during apnea and disconnection from the ventilator. CFI was administered via a modified endotracheal tube in which small capillaries allowed delivery of a high-velocity jet flow near the tracheal end of the tube during disconnection from the ventilator. In comparison to apnea alone, CFI prevented a fall in arterial oxygen tension (16 +/- 7 mm Hg during CFI versus 117 +/- 27 during apnea, after 90 s of disconnection in the two situations, p less than 0.001), whereas it did not reduce the development of hypercapnia. The efficacy of CFI resulted both from the injection of oxygen into the trachea and from the maintenance of positive alveolar pressure induced by air entrainment (mean 10.4 +/- 1.1 cm H2O), preventing a fall in lung volume usually occurring after disconnection (+338 +/- 88 ml during CFI versus -344 +/- 64 ml during apnea, p less than 0.01). In the second part of the study CFI was used to prevent arterial oxygen desaturation induced by endotracheal suctioning.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Reversal of acute exacerbations of chronic obstructive lung disease by inspiratory assistance with a face mask.

BACKGROUND: Patients with acute exacerbations of chronic obstructive pulmonary disease may require endotracheal intubation with mechanical ventilation. We designed, and here report on the efficacy of, a noninvasive ventilatory-assistance apparatus to provide inspiratory-pressure support by means of a face mask. METHODS: We assessed the short-term (45-minute) physiologic effects of the apparatus in 11 patients with acute exacerbations of chronic obstructive pulmonary disease and evaluated its therapeutic efficacy in 13 such patients (including 3 of the 11 in the physiologic study) who were treated for several days and compared with 13 matched historical-control patients. RESULTS: In the physiologic study, after 45 minutes of inspiratory positive airway pressure by face mask, the mean (+/- SD) arterial pH rose from 7.31 +/- 0.08 to 7.38 +/- 0.07 (P less than 0.01), the partial pressure of carbon dioxide fell from 68 +/- 17 mm Hg to 55 +/- 15 mm Hg (P less than 0.01), and the partial pressure of oxygen rose from 52 +/- 12 mm Hg to 69 +/- 16 mm Hg (P less than 0.05). These changes were accompanied by marked reductions in respiratory rate (from 31 +/- 7 to 21 +/- 9 breaths per minute, P less than 0.01). Only 1 of the 13 patients treated with inspiratory positive airway pressure needed tracheal intubation and mechanical ventilation, as compared with 11 of the 13 historical controls (P less than 0.001). Two patients in each group died. As compared with the controls, the treated patients had a more transient need for ventilatory assistance (3 +/- 1 vs. 12 +/- 11 days, P less than 0.01) and a shorter stay in the intensive care unit (7 +/- 3 vs. 19 +/- 13 days, P less than 0.01). CONCLUSIONS: Inspiratory positive airway pressure delivered by a face mask can obviate the need for conventional mechanical ventilation in patients with acute exacerbations of chronic obstructive pulmonary disease.

Acute Disease↗

Increase in tracheal pressure during jet ventilation.

Gas injection systems used in several techniques of ventilation cause increases in airway pressure and physiological changes which are frequently overlooked. The momentum flux theory describes such phenomena most appropriately. We have defined and measured the characteristics of such increases in airway pressure, using a lateral tracheal injection system which has been described previously. In such a system, wall friction is a major source of loss in jet momentum flux, in contrast with the changes in axis-symmetrical systems. This process results in a potentially beneficial increase in airway pressure and in greater mixing, which might be clinically useful.

Animals↗

The ventilatory effect of external oscillation.

High frequency ventilation (HFV) may be achieved by external oscillation (external HFV) applied around the chest wall (HFCWO) in large animals and humans, or over the entire body (HFBSO) in small animals, instead of being applied via the trachea (internal HFV). We present a synthesis of the results obtained with external HFV in both normal and bronchoconstricted subjects. Whereas external and internal HFV were found to be equivalent in terms of gas exchange in normal rats, external HFV was found to have a beneficial effect in bronchoconstricted rabbits, but internal HFV did not. From the frequency-oscillatory tidal volume relationship determined in normocapnic rabbits, HFBSO at 5 Hz was found to be the optimal frequency at which to ventilate with tidal volumes close to the dead space volume, and which was also shown to be the optimal volume to obtain normocapnia. Moreover, 5 Hz oscillations (HFCWO) at 20 ml and 40 ml superimposed on tidal breathing accelerated nitrogen washout, i.e., gas exchange in normal humans. Unfortunately, only oscillations with much smaller volumes (5-10 ml) were obtainable in COPD patients. Nevertheless, they produced a clear change in breathing pattern associated with a slight improvement in gas exchange and a potentially positive effect on inspiratory muscle fatigue. These results support the concept that non-invasive external HFV technique may be of use in assisting ventilation in bronchoconstricted subjects and may possibly replace conventional controlled ventilation, at least in subjects with high lung compliance, such as babies, neonates and normal adults.

Animals↗

Effect of air entrainment on airway pressure during endotracheal gas injection.

Turbulent jets in endotracheal tubes induce air entrainment and airway pressure changes. We attempted to understand the physical explanation for these effects, which open up to a wide range of applications in intubated patients. An in vitro study was performed on standard size endotracheal tubes with diameters of 8, 7, and 3 mm and several capillaries molded into the wall (less than 1 mm diam) allowing gas injection at approximately 1-2 cm from the tracheal end of the endotracheal tube. This produced a jet velocity-dependent gain in tracheal pressure (Ptr) during inspiration. Data have been interpreted with a theory, based on the classic momentum theorem, which indicates that the mechanisms involved resemble those of axisymmetrical confined jets: air entrainment by turbulent friction with a longitudinal increase in lateral pressure. The difference with axisymmetrical systems lies in the nonconservation of the total thrust in our system because, secondary to wall friction and to the nonaxial incidence of the jets, only a fraction of the jet momentum flux is transformed into pressure. This suggests faster mixing in the present lateral jet system, as shown by 1) the independence of Ptr on tracheal geometry and 2) the very rapid increase in lateral pressure. The present study supports the idea that pressure changes in the airways, which are potentially beneficial in intubated patients, can be satisfactorily generated by turbulent jets.

Intubation, Intratracheal↗

High frequency chest wall oscillation in patients with chronic air-flow obstruction.

In order to assess high frequency chest wall oscillation (HFCWO) as a way to assist spontaneous breathing in obstructive lung disease, we studied 12 patients with severe and stable COPD. HFCWO at 5 Hz were applied by means of an inflatable vest. In order to avoid any discomfort, oscillations were applied only during the expiratory phase of the spontaneous breathing cycle. We compared gas exchange and pattern of breathing during control and HFCWO periods, each lasting 15 min. Minute ventilation did not change, but the pattern of breathing was markedly altered during HFCWO: breathing frequency decreased (p less than 0.001) from 18 +/- 6/min during control to 14 +/- 5/min, whereas tidal volume increased (p less than 0.01) from 600 +/- 200 ml during control to 860 +/- 400 ml. Secondary to this change in the pattern of breathing, arterial PO2 increased slightly (p less than 0.01) from 54 +/- 7 mm Hg during control to 57 +/- 8 mm Hg during HFCWO, and arterial PCO2 significantly (p less than 0.01) decreased from 46 +/- 6 mm Hg during control to 43 +/- 7 mm Hg during HFCWO. In addition, duty cycle (Ti/Ttot) decreased (p less than 0.001) from 0.37 +/- 0.03 s during control to 0.29 +/- 0.05 s during HFCWO. Such a decrease in duty cycle suggest that inspiratory muscle work was facilitated under HFCWO. In 8 patients, we obtained the tension-time index (TTdi), or the product of duty cycle and Pdi/Pdimax, and found that this index significantly decreased (p less than 0.05) from 0.06 +/- 0.03 during control to 0.04 +/- 0.02 during HFCWO.(ABSTRACT TRUNCATED AT 250 WORDS)

Dyspnea↗

Dependence of central airway resistance on frequency and tidal volume: a model study.

The resistance of a hollow cast of human central airways was measured during true sinusoidal airflow oscillations over a wide range of frequencies (0.5-40 Hz) and for various flow amplitudes up to 8 l/s. Pressure and flow were measured in the trachea with high-performance transducers, digitized and averaged over 100 cycles. Data were studied at two points in the flow cycle: at peak inspiratory and expiratory flows and in the two neighborhoods around zero flow where airway resistance (Rv approximately equal to o) was taken as the average slope of the pressure-flow (P-V) curve in each zone. When data obtained near peak flow were plotted in terms of dimensionless pressure drop vs. peak Reynolds number (Rem) and compared with steady-state data, we found no difference up to 2 Hz as previously reported (Isabey and Chang, J. Appl. Physiol. 51: 1338-1348, 1981), a slight decay in pressure drop between 4 and 8 Hz, a frequency-dependent increase in peak flow resistance at high frequencies (10-40 Hz) governed by the Strouhal number alpha 2/Rem beyond alpha 2/Rem = 0.5. On the other hand RV approximately equal to o was found to increase relative to steady state as local acceleration increases, e.g., as peak flow increases at a fixed frequency; this differs from the classical linear theory of oscillatory flow in a long straight tube. To explain these results, we had to use, as in our previous study, an alternative expression for the Strouhal number, i.e., epsilon = L X A X (dV/dt)/V2 (where L and A are the length and cross-sectional area of the trachea and V is a constant flow range over which resistance around flow reversal was computed), which accurately reflects the ratio of local acceleration [d(V/A)/dt)] to convective acceleration [(V/A)2/L] in developing branching flow. Finally, to delineate the regions of dominance of each of the dimensionless parameters, we compiled frequency-tidal volume diagrams for peak flows as well as for reversal. Epsilon, which is negligible near peak flows, appeared to govern the oscillatory P-V relationship near flow reversal in a transitional region of the diagram located between regions of steadiness, or moderate unsteadiness, and a region of dominant unsteadiness governed by alpha.

Airway Resistance↗

High frequency transthoracic ventilation improves gas exchange during experimental bronchoconstriction in rabbits.

In order to evaluate the efficacy of ventilation by high frequency transthoracic oscillation in obstructive lung disease, we studied 10 anesthetized and paralyzed rabbits during experimental bronchoconstriction. In order to generate body surface oscillation, the animals were placed in a body-box connected to a piston pump. Two frequencies were successively applied in random order: 1 Hz, representing "conventional" ventilation, and 5 Hz for high frequency ventilation. During the control period, the magnitudes of the oscillation were adjusted such that the tidal volumes thus produced yielded normocapnia (PaCO2 = 40 +/- 2 mmHg) for at least 3 min at each frequency. The same tidal volumes were then used after a bronchoconstriction induced by aerosolized carbachol. We obtained a severe and stable bronchoconstriction and oscillated the animals at 1 and 5 Hz at identical tidal volumes as those used during the control period. Identical at the 2 frequencies of oscillation during the control period, the rate of CO2 elimination with bronchoconstriction was significantly higher (p less than 0.05) at 5 Hz (15.9 +/- 3.3 ml/min) than at 1 Hz (14.2 +/- 3.9 ml/min); PaCO2 was also significantly lower at 5 Hz than at 1 Hz. Mean arterial PO2 was significantly higher (p less than 0.01) at 5 Hz (58 +/- 4 mmHg) than at 1 Hz (46 +/- 12 mmHg) during bronchoconstriction. Mean alveolararterial O2 pressure difference was significantly lower (p less than 0.01) at 5 Hz (49 +/- 13 mmHg) than at 1 Hz (59 +/- 11 mmHg). Only a minor increase in lung volume was found during high frequency ventilation, and no significant hemodynamic changes occurred.(ABSTRACT TRUNCATED AT 250 WORDS)

Airway Resistance↗

Pressure change and gas mixing induced by oscillations in a closed system.

In an attempt to delineate some mechanical behaviors found in branching airways, pressure transmission, gas motion, and mixing were studied during high-frequency oscillation (HFO) in an idealized system consisting of a large straight tube and a rigid sphere linked together by a small straight tube. Depending on the frequency f, and on the unsteadiness dimensionless parameter alpha, pressure amplitude in the large tube is either strongly attenuated or amplified in the sphere. This finding may provide a theoretical basis for the pressure resonance phenomenon observed in the lung by previous investigators. Gas compression in the closed volume causes convective mixing throughout the system. The measured dispersion was found to be proportional to f(VT/A)2, in agreement with a recent report. However, bulk convective mixing was sufficient to explain the dispersion for oscillatory volumes (VT) as small as 80 percent of the small tube volume, as has been previously suggested.

Biomechanical Phenomena↗

Stable normocapnia during high-frequency body surface oscillation in rabbits.

In order to identify the useful range of frequencies and the effect of lung volume on gas exchange during high-frequency ventilation, particularly during high-frequency body surface oscillation (HFBSO), we studied 12 normal, anesthetized, and paralyzed adult rabbits in 2 groups at 1, 3, 5, 8, 12, and 16 Hz in random order. The rabbits were placed in a body box, and a "bias" flow system different from all previously reported systems was used. For a given animal at a given frequency, the oscillation magnitude was adjusted to ensure normocapnia, defined as PaCO2 equal to 40 +/- 2 mmHg, for at least 5 min. For the first group (n = 6) with a mean tracheal pressure of 0.5 cmH2O, the necessary tidal volumes (mean +/- SD) were 3.7 +/- 0.2, 1.9 +/- 0.2, and 1.5 +/- 0.1 ml/kg at 1, 3, and 5 Hz, respectively. Further increases in frequency resulted in only small decreases in the required tidal volumes: 1.4 +/- 0.1, 1.2 +/- 0.1, and 1.2 +/- 0.1 ml/kg at 8, 12, and 16 Hz, respectively. Arterial PO2 values were very similar at all 6 frequencies, with a mean of 78.6 +/- 3.3 mmHg in this group. For the second group (n = 6) with a mean tracheal pressure of 5 cmH2O, arterial PO2 values were again the same at all frequencies applied but were significantly higher (95.5 +/- 2.6 mmHg) than in the first group. No significant difference was observed in the tidal volumes required to maintain normocapnia between the 2 groups, i.e., at the 2 mean tracheal pressures studied.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗