Measurement of bile acid CoA esters by high-performance liquid chromatography-electrospray ionisation tandem mass spectrometry (HPLC-ESI-MS/MS).

The novel and rapid assay presented here combines high-performance liquid chromatography and electrospray ionisation tandem mass spectrometry (HPLC-ESI-MS/MS) to directly measure and quantify the CoA esters of 3alpha,7alpha,12alpha-trihydroxy- and 3alpha,7alpha-dihydroxy-5beta-cholestan-26-oic acid (THCA and DHCA). The latter are converted inside peroxisomes to the primary bile acids, cholic and chenodeoxycholic acids, respectively. Prior to MS/MS, esters were separated by reversed-phase HPLC on a C(18) column using an isocratic mobile phase (acetonitrile/water/2-propanol) and subsequently detected by multiple reaction monitoring. For quantification, the CoA ester of deuterium-labelled 3alpha,7alpha,12alpha-trihydroxy-5beta-cholan-24-oic acid (d(4)-CA) was used as internal standard. To complete an assay took less than 8 min. To verify the validity of the assay, the effect of peroxisomal proteins on the efficacy of extraction of the CoA esters was tested. To this end, variable amounts of the CoA esters were spiked with a fixed amount of either intact peroxisomes or peroxisomal matrix proteins and then extracted using a solid-phase extraction system. The CoA esters could be reproducibly recovered in the range of 0.1-4 micromol l(-1) (linear correlation coefficient R(2) > 0.99), with a detection limit of 0.1 micromol l(-1). In summary, electrospray ionization tandem mass spectrometry combined with HPLC as described here proved to be a rapid and versatile technique for the determination of bile acid CoA esters in a mixture with peroxisomal proteins. This suggests this technique to become a valuable tool in studies dealing with the multi-step biosynthesis of bile acids and its disturbances in disorders like the Zellweger syndrome.

Acyl Coenzyme A↗

Postnatal changes in neonatal acylcarnitine profile.

++Electrospray-tandem mass spectrometry represents a powerful method for detection of inborn errors of fatty acid metabolism. In the present study, it was used to examine neonatal carnitine metabolism, which reflects fatty acid metabolism. In 70 healthy neonates, blood samples were taken from the umbilical cord and by heel-stick puncture in full-term neonates on postnatal d 5. Cord blood specimens were also obtained from 15 preterm and 10 small-for-gestational-age infants. Acylcarnitine concentrations were measured in dried blood spots by electrospray tandem mass spectrometry. Compared with cord blood, the levels of nearly all acylcarnitine species were significantly higher on the postnatal d 5, whereas free carnitine remained unchanged. Total acylcarnitine/free carnitine-ratio increased, whereas the free carnitine/total carnitine-ratio (0.54 +/- 0.05; p < 0.01) further decreased. A reduced availability of free carnitine in the early neonatal period may affect fatty acid oxidation and thus be of potential pathophysiological relevance under conditions with higher energy demands, e.g. in sepsis. Cord blood concentrations of free carnitine, total carnitine, and total acylcarnitines were strongly related to birth weight (p < 0.01). Lower umbilical artery pH, i.e. mild hypoxia, caused accumulation of mainly long-chain acylcarnitines. This implicates that long-chain acylcarnitines could serve as a parameter of perinatal asphyxia.

Carnitine↗

Sensitivity of electrospray-tandem mass spectrometry using the phenylalanine/tyrosine-ratio for differential diagnosis of hyperphenylalaninemia in neonates.

The sensitivity of amino acid analysis by electrospray-tandem mass spectrometry (ESI-TMS) in differential diagnosis of the different forms of hyperphenylalaniemias (HPA) was studied in a total number of 78 dried blood samples from neonates with increased phenylalanine (Phe) concentrations (> 150 micromol/l). Simultaneous quantitative analysis of Phe and tyrosine (Tyr) were performed by ESI-TMS. By means of the Phe/Tyr-ratio it was possible to differentiate between phenylketonuria (PKU; n = 23) and nonPKU-HPA patients (n = 35; P < 0.001) with a sensitivity of 100%. Neonates with transient HPA (n = 9) showed a lower Phe/Tyr-ratio compared to the nonPKU-HPA patients (P < 0.001). Amino acid analysis by ESI-TMS represents a powerful diagnostic tool in differential diagnosis of HPA and is an appropriate technique in the setting of neonatal screening based on dried blood spots.

Diagnosis, Differential↗