Postnatal changes in neonatal acylcarnitine profile.

Abstract

++Electrospray-tandem mass spectrometry represents a powerful method for detection of inborn errors of fatty acid metabolism. In the present study, it was used to examine neonatal carnitine metabolism, which reflects fatty acid metabolism. In 70 healthy neonates, blood samples were taken from the umbilical cord and by heel-stick puncture in full-term neonates on postnatal d 5. Cord blood specimens were also obtained from 15 preterm and 10 small-for-gestational-age infants. Acylcarnitine concentrations were measured in dried blood spots by electrospray tandem mass spectrometry. Compared with cord blood, the levels of nearly all acylcarnitine species were significantly higher on the postnatal d 5, whereas free carnitine remained unchanged. Total acylcarnitine/free carnitine-ratio increased, whereas the free carnitine/total carnitine-ratio (0.54 +/- 0.05; p < 0.01) further decreased. A reduced availability of free carnitine in the early neonatal period may affect fatty acid oxidation and thus be of potential pathophysiological relevance under conditions with higher energy demands, e.g. in sepsis. Cord blood concentrations of free carnitine, total carnitine, and total acylcarnitines were strongly related to birth weight (p < 0.01). Lower umbilical artery pH, i.e. mild hypoxia, caused accumulation of mainly long-chain acylcarnitines. This implicates that long-chain acylcarnitines could serve as a parameter of perinatal asphyxia.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Meyburg, A Schulze, D Kohlmueller, O Linderkamp, E Mayatepek. 2001. Postnatal changes in neonatal acylcarnitine profile.. https://doi.org/10.1203/00006450-200101000-00024

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Advances in carnitine in chronic uremia.

Carnitine is a conditionally essential metabolite that plays a critical role in cell physiology. Carnitine is necessary for fatty acid transport to sites of beta-oxidation in the mitochondria, where it helps to prevent organic acid accumulation. Because of these key regulatory functions, carnitine represents a crucial determinant of mitochondrial energy metabolism, whose deficiency may lead to metabolic and clinical disturbances. Loss of carnitine through dialytic membranes occurs in maintenance hemodialysis, resulting in potential carnitine depletion and relative increments of esterified carnitine forms. Carnitine supplementation has been shown to counteract such alterations and may be associated with clinical benefit. In particular, carnitine supplementation in patients on hemodialysis may enhance response to erythropoietin, resulting in improved hematologic status. Carnitine was also reported to improve exercise tolerance and intradialytic symptoms. Carnitine supplementation may enhance insulin resistance, inflammatory and antioxidant status, protein balance, lipid profile, and cardiac function. Carnitine administration can be useful for selected patients on dialysis who do not adequately respond to standard therapy.

Carnitine↗

Rapid determination of short chain carnitines in human plasma by electrospray ionisation-ion trap mass spectrometry using capillary electrophoresis instrument as sampler.

A capillary electrophoresis apparatus was used as sampler for flow injection analysis (FIA) in tandem mass spectrometry of L-carnitine and its acetyl- and propionyl-metabolites in human plasma. The capillary electrophoresis instrument was coupled to the ion trap mass spectrometer by an electrospray ionization coaxial sheath liquid interface. The electrophoresis capillary introduced the sample directly into the source by applying a prolonged sample injection. The use of the capillary electrophoresis apparatus miniaturised the FIA procedure, substantially reducing the quantities of solvents and samples used, and allowed rapid automated sequential analyses. The method was optimised and validated using a dialyzed human plasma matrix. The plasma samples were analysed after a simple, rapid deproteinisation procedure with acetonitrile and diluted 70 times before direct injection into the mass spectrometer for product ion scan MS/MS analysis in positive ionisation. The total analysis time was 5 min, including capillary preconditioning and acquisition time (3 min). The method was sensitive, allowing the determination of L-, L-acetyl- and L-propionyl-carnitines at 140, 14 and 3.6 nM concentrations (injected values) corresponding to lower limit of quantitation values in plasma of 10, 1 and 0.25 microM, respectively. The method was processed for full validation and applied to the analysis of L-carnitine and its short chain derivatives in human plasma samples.

Carnitine↗