On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies.

A dark band or rim along parts of the subendocardial border of the left ventricle (LV) and the myocardium has been noticed in some dynamic contrast-enhanced MR perfusion studies. The artifact is thought to be due to susceptibility effects from the gadolinium bolus, motion, or resolution, or a combination of these. Here motionless ex vivo hearts in which the cavity was filled with gadolinium are used to show that dark rim artifacts can be consistent with resolution effects alone.

Algorithms↗

Improved accuracy and consistency in T1 measurement of flowing blood by using inversion recovery GE-EPI.

Problems associated with techniques currently used to measure the T1 of flowing blood are evaluated and a method to improve the consistency and repeatability of measurements is presented. Similar to some currently used techniques, the pulse sequence employs a nonselective adiabatic inversion pulse followed by a series of ECG-gated gradient echo EPI (echo planar imaging) images to obtain images where the blood (fluid) signal exhibits a T1-dependent inversion recovery signal from which the spin lattice relaxation constant (T1) of the flowing fluid can be measured. The new method combines curve fitting with a measure of the curve null point to acquire more accurate and consistent T1 values. Simulation and experimental results show that this combined fitting-nulling method is more stable and consistent in measuring the T1 of flowing fluid. The feasibility of temperature measurement of a flowing fluid based on the temperature dependence of the T1 of water protons is shown in this paper. ECG gating is used to reduce the effects of cyclic intensity changes for measurement of T1 in pulsatile flowing blood.

Blood Flow Velocity↗

Comparison of temporal filtering methods for dynamic contrast MRI myocardial perfusion studies.

Dynamic contrast myocardial perfusion studies may benefit from methods that speed up the acquisition. Unaliasing by Fourier encoding the overlaps using the temporal dimension (UNFOLD), and a similar linear interpolation method have been shown to be effective at reducing the number of phase encodes needed for cardiac wall motion studies by using interleaved sampling and temporal filtering. Here such methods are evaluated in cardiac dynamic contrast studies, with particular regard to the effects of the choice of filter and the interframe motion. Four different filters were evaluated using a motion-free canine study. Full k-space was acquired and then downsampled to allow for a measure of truth. The different filters gave nearly equivalent images and quantitative flow estimates compared to full k-space. The effect of respiratory motion on these schemes was graphically depicted, and the performance of the four temporal filters was evaluated in seven human subjects with respiratory motion present. The four filters provided images of similar quality. However, none of the filters were effective at eliminating motion artifacts. Motion registration methods or motion-free acquisitions may be necessary to make these reduced FOV approaches clinically useful.

Algorithms↗

Designing intervention effectiveness studies for occupational health and safety: The Minnesota Wood Dust Study.

BACKGROUND: A planning model was used to guide the design of a randomized controlled study of the effectiveness of tailored interventions in lowering dust exposures in small woodworking shops. METHODS: Guided by Green's PRECEDE-PROCEED model, we used a planning committee, focus groups and a pilot study to gain information on small woodworking shops, causes of and controls for high dust levels, and barriers and incentives surrounding availability and use of dust controls. RESULTS: The planning committee identified key characteristics of small woodworking shop owners. Focus groups with owners and employees served to further elucidate why dust control was considered unimportant. The pilot study gave measures of dust exposures, tasks, and use of controls. Interventions focused on providing owners with technical and economic assistance to lower dust levels and an educational program for employees discussing health effects and effective methods of dust control. CONCLUSIONS: The PRECEDE-PROCEED model proved a useful framework for designing an intervention in the occupational setting.

Dust↗

Comparison of gradient encoding schemes for diffusion-tensor MRI.

The accuracy of single diffusion tensor MRI (DT-MRI) measurements depends upon the encoding scheme used. In this study, the diffusion tensor accuracy of several strategies for DT-MRI encoding are compared. The encoding strategies are based upon heuristic, numerically optimized, and regular polyhedra schemes. The criteria for numerical optimization include the minimum tensor variance (MV), minimum force (MF), minimum potential energy (ME), and minimum condition number. The regular polyhedra scheme includes variations of the icosahedron. Analytical comparisons and Monte Carlo simulations show that the icosahedron scheme is optimum for six encoding directions. The MV, MF, and ME solutions for six directions are functionally equivalent to the icosahedron scheme. Two commonly used heuristic DT-MRI encoding schemes with six directions, which are based upon the geometric landmarks of a cube (vertices, edge centers, and face centers), are found to be suboptimal. For more than six encoding directions, many methods are able to generate a set of equivalent optimum encoding directions including the regular polyhedra, and the ME, MF and MV numerical optimization solutions. For seven directions, a previously described heuristic encoding scheme (tetrahedral plus x, y, z) was also found to be optimum. This study indicates that there is no significant advantage to using more than six encoding directions as long as an optimum encoding is used for six directions. Future DT-MRI studies are necessary to validate these observations. J. Magn. Reson. Imaging 2001;13:769-780.

Artifacts↗

Analysis of partial volume effects in diffusion-tensor MRI.

The diffusion tensor is currently the accepted model of diffusion in biological tissues. The measured diffusion behavior may be more complex when two or more distinct tissues with different diffusion tensors occupy the same voxel. In this study, a partial volume model of MRI signal behavior for two diffusion-tensor compartments is presented. Simulations using this model demonstrate that the conventional single diffusion tensor model could lead to highly variable and inaccurate measurements of diffusion behavior. The differences between the single and two-tensor models depend on the orientations, fractions, and exchange between the two diffusion tensor compartments, as well as the diffusion-tensor encoding technique and diffusion-weighting that is used in the measurements. The current single compartment model's inaccuracies could cause diffusion-based characterization of cerebral ischemia and white matter connectivity to be incorrect. A diffusion-tensor MRI imaging experiment on a normal human brain revealed significant partial volume effects between oblique white matter regions when using very large voxels and large diffusion-weighting (b approximately 2.69 x 10(3) sec/mm(2)). However, the apparent partial volume effects in white matter decreased significantly when smaller voxel dimensions were used. For diffusion tensor studies obtained using typical diffusion-weighting values (b approximately 1 x 10(3) sec/mm(2)) partial volume effects are much more difficult to detect and resolve. More accurate measurements of multiple diffusion compartments may lead to improved confidence in diffusion measurements for clinical applications.

Anisotropy↗

Analytical computation of the eigenvalues and eigenvectors in DT-MRI.

In this paper a noniterative algorithm to be used for the analytical determination of the sorted eigenvalues and corresponding orthonormalized eigenvectors obtained by diffusion tensor magnetic resonance imaging (DT-MRI) is described. The algorithm uses the three invariants of the raw water spin self-diffusion tensor represented by a 3 x 3 positive definite matrix and certain math functions that do not require iteration. The implementation requires a positive definite mask to preserve the physical meaning of the eigenvalues. This algorithm can increase the speed of eigenvalue/eigenvector calculations by a factor of 5-40 over standard iterative Jacobi or singular-value decomposition techniques. This approach may accelerate the computation of eigenvalues, eigenvalue-dependent metrics, and eigenvectors especially when having high-resolution measurements with large numbers of slices and large fields of view.

Algorithms↗

Breathing patterns and cardiovascular autonomic modulation during hypoxia induced by simulated altitude.

OBJECTIVE: To assess the influence of different breathing patterns on autonomic cardiovascular modulation during acute exposure to altitude-induced hypoxia. DESIGN: We measured relative changes in minute ventilation (VE), oxygen saturation (%SaO2), spectral analysis of RR interval and blood pressure, and response to stimulation of carotid baroreceptors (neck suction) at baseline and after acute (1 h) hypobaric hypoxia (equivalent to 5,000 m, in a hypobaric chamber). METHODS: We studied 19 human subjects: nine controls and 10 Western yoga trainees of similar age, while breathing spontaneously, at 15 breaths/min (controlled breathing) and during 'complete yogic breathing' (slow diaphragmatic + thoracic breathing, approximately 5 breaths/min) in yoga trainees, or simple slow breathing in controls. RESULTS: At baseline %SaO2, VE and autonomic pattern were similar in both groups; simulated altitude increased VE in controls but not in yoga trainees; %SaO2 decreased in all subjects (P< 0.0001), but more in controls than in yoga trainees (17 versus 12%, 14 versus 9%, 14 versus 8%, all P< 0.05 or better, during spontaneous breathing, controlled breathing and yogic or slow breathing, respectively). Simulated altitude decreased RR interval (from 879 +/- 45 to 770 +/- 39, P < 0.01) and increased indices deducted from spectral analysis of heart rate variability (low frequency/high frequency (LF/HF) ratio from 1.6 +/- 0.5 to 3.2 +/- 1.1, P < 0.05) and systolic blood pressure (low-frequency fluctuations from 2.30 +/- 0.31 to 3.07 +/- 0.24 In-mmHg2, P< 0.05) in controls, indicating sympathetic activation; these changes were blunted in yoga trainees, and in both groups during slow or yogic breathing. No effect of altitude was seen on stimulation of carotid baroreceptors in both groups. CONCLUSIONS: Well-performed slow yogic breathing maintains better blood oxygenation without increasing VE (i.e. seems to be a more efficient breathing) and reduces sympathetic activation during altitude-induced hypoxia.

Adult↗

Detection of toxigenicity by a probe for the microcystin synthetase A gene (mcyA) of the cyanobacterial genus Microcystis: comparison of toxicities with 16S rRNA and phycocyanin operon (Phycocyanin Intergenic Spacer) phylogenies.

The relationship between toxigenicity and phylogeny within the cyanobacterial genus Microcystis is unclear. To investigate this issue, we have designed PCR primers for the N-methyltransferase (NMT) domain of the microcystin synthetase gene mcyA and have probed 37 Microcystis sp. cultures as well as several field samples. The NMT region was present in all 18 laboratory strains that gave positive reactions in the protein phosphatase inhibition assay for microcystin but was absent in 17 nontoxic strains. Two other nontoxic strains, one of which had previously been reported to produce microcystin, possessed the NMT region. Detection of NMT-specific DNA in field samples corresponded to periods of toxicity as assessed by protein phosphatase inhibition. The Microcystis strains formed a monophyletic cluster based on 16S rRNA gene sequences but comprised two groups with respect to phycocyanin intergenic spacer (PC-IGS) sequences. Toxic and nontoxic strains appeared to be erratically distributed within the PC-IGS and 16S rRNA trees. Sequence analysis of the NMT domain revealed two coherent groups. The genomic region immediately downstream of the mcyABC cluster in all 20 NMT-positive strains contained an open reading frame of unknown function (uma1) at a conserved distance from mcyC. All nontoxic strains also contained uma1, which is not cotranscribed with mcyABC. The consistent linkage of mcyC to uma1 suggests that mcyC has not been frequently transferred into nontoxic strains via any mechanism involving insertion at random chromosomal locations. These results are discussed with respect to various mechanisms that could explain the patchy distribution of toxigenicity among the various Microcystis clades.

Bacterial Proteins↗

Enhanced image detail using continuity in the MIP Z-buffer: applications to magnetic resonance angiography.

In this paper a new algorithm is presented for the segmentation and display of blood vessels from images obtained with magnetic resonance angiography (MRA) and other three-dimensional (3D) angiographic imaging techniques. The algorithm developed is based on the observation that vessels are strongly evident in the maximum intensity projection (MIP) Z-buffer as regions of high continuity and low local roughness. Roughness is measured here by the minimum chi2 value of a low-order local least-squares fit in the principal directions through each point in the MIP Z-buffer. Although some background pixels in the Z-buffer exhibit low local roughness, the size of the connected region is nearly always much smaller than even the very smallest vessels that appear in the MIP image. It is shown that by applying connectivity to the regions of low roughness, there is nearly complete separation between vascular detail and background. When connectivity is further applied in the original 3D image, vascular bed segmentation becomes nearly complete. The algorithm consists of three basic steps: a) determination of the minimum local roughness at each point in the MIP Z-buffer; b) connection of all neighboring points of low local roughness; and c) connection of all points in the original 3D image matrix that are connected to the points determined in the MIP Z-buffer and that are above an intensity threshold. The algorithm as presented is not optimized but demonstrates a very strong potential for improved portrayal of vascular detail.

Algorithms↗

A three-coil comparison for MR angiography.

The purpose of this work was to compare intracranial magnetic resonance angiography (MRA) image quality using three different radiofrequency coils. The three coil types included a reduced volume quadrature birdcage coil with endcap, a commercially available quadrature birdcage head coil, and a four-element phased-array coil. Signal-to-noise ratio (SNR) measurements were obtained from comparison studies performed on a uniform cylindrical phantom. MRA comparisons were performed using data acquired from 15 volunteers and applying a thick-slab three-dimensional time-of-flight sequence. Analysis was performed using the signal difference-to-noise ratio, a quantitative measure of the relative vascular signal. The reduced-volume endcap and phased-array coils, which were designed specifically for imaging the intracranial volume of the head, improved the image SNR and vascular detail considerably over that obtained using the commercially available head coil. The endcap coil configuration provided the best vascular signal overall, while the phased-array coil provided the best results for arteries close to the coil elements.

Brain↗

A generalized k-sampling scheme for 3D fast spin echo.

The phase-encoding scheme can significantly affect the quality of fast spin-echo (FSE) images because the echo amplitude is modulated as a function of the echo position in k-space. The effects of the modulation in two-dimensional FSE imaging include ghosting and blurring artifacts and resolution loss in the phase-encoding (PE) direction. In 3D FSE imaging, the use of two PE directions presents the opportunity for improved PE schemes. A new scheme for assignment of echoes to views in 3D FSE, termed generalized, has been developed. This scheme distributes T(2) effects along both PE directions, allowing considerable flexibility in the selection of blurring artifact appearance. In a set of simulations, phantom experiments, and in vivo experiments, the performance of the generalized PE scheme for 3D FSE imaging was compared with the performance of existing PE schemes. The results demonstrate that the generalized PE scheme can be used to reduce blurring artifacts greatly relative to other PE techniques that are presently in use. This approach to PE can be used to manipulate the blurring artifact appearance and to optimize acquisition time.

Artifacts↗

A median filter for 3D FAST spin echo black blood images of cerebral vessels.

High-resolution black-blood MRA images of intracranial vascular anatomy can be obtained using 3D fast spin-echo techniques. Although these images demonstrate excellent contrast between vessels and surrounding soft tissues, the dark signal from air and bone can obscure the desired vascular information when a minimum intensity projection image is created. In this paper, we describe an image processing technique based upon a median filter that is effective for detecting narrow vessel-like structures. Minimum intensity projection images of the filtered MRA volume can be obtained in any orientation without prior segmentation of the skull or surrounding air spaces. The filter is very effective for detecting and visualizing small vessels, but is much less effective for detecting vessels and vascular pathology larger than the filter detection width. The filtering technique is demonstrated on black-blood MRA images from a volunteer study.

Algorithms↗

Intensity correction by subtraction for phased-array MRA images.

A method of intensity correction is described that is particularly useful for magnetic resonance angiography images acquired with phased-array coils. In this method a low-pass filtered version of the image is subtracted from the original image to remove signal variations due to the phased-array coil. This avoids the noise amplification caused by division correction and enhances the signal-to-noise ratio of small arteries in maximum intensity projections. J. Magn. Reson. Imaging 2000;12:501-504.

Cerebellum↗

A geometric analysis of diffusion tensor measurements of the human brain.

The degree of diffusion tensor anisotropy is often associated with the organization of structural tissues such as white matter. Numerous measures of diffusion anisotropy have been proposed, which could lead to confusion in interpreting and comparing results from different studies. In this study, a new method for representing the diffusion tensor shape, called the three-phase (3P) plot, is described. This is a graphical technique based upon a barycentric coordinate system, which weights the tensor shape by a combination of linear, cylindrical, and spherical shape factors. This coordinate system can be used to map and potentially segment different tissues based upon the tensor shape. In addition, the 3P plot can be used to examine the shape properties of existing measures of diffusion anisotropy. In this paper, the 3P plot is used to compare four well-known anisotropy measures: the anisotropy index, the fractional anisotropy, the relative anisotropy, and the volume fraction. Computer simulations and diffusion tensor images of normal brains were obtained to study the properties of this new mapping technique. Magn Reson Med 44:283-291, 2000.

Anisotropy↗

Physiological and anthropometric determinants of sport climbing performance.

OBJECTIVE: To identify the physiological and anthropometric determinants of sport climbing performance. METHODS: Forty four climbers (24 men, 20 women) of various skill levels (self reported rating 5.6-5.13c on the Yosemite decimal scale) and years of experience (0.10-44 years) served as subjects. They climbed two routes on separate days to assess climbing performance. The routes (11 and 30 m in distance) were set on two artificial climbing walls and were designed to become progressively more difficult from start to finish. Performance was scored according to the system used in sport climbing competitions where each successive handhold increases by one in point value. Results from each route were combined for a total climbing performance score. Measured variables for each subject included anthropometric (height, weight, leg length, arm span, % body fat), demographic (self reported climbing rating, years of climbing experience, weekly hours of training), and physiological (knee and shoulder extension, knee flexion, grip, and finger pincer strength, bent arm hang, grip endurance, hip and shoulder flexibility, and upper and lower body anaerobic power). These variables were combined into components using a principal components analysis procedure. These components were then used in a simultaneous multiple regression procedure to determine which components best explain the variance in sport rock climbing performance. RESULTS: The principal components analysis procedure extracted three components. These were labelled training, anthropometric, and flexibility on the basis of the measured variables that were the most influential in forming each component. The results of the multiple regression procedure indicated that the training component uniquely explained 58.9% of the total variance in climbing performance. The anthropometric and flexibility components explained 0.3% and 1.8% of the total variance in climbing performance respectively. CONCLUSIONS: The variance in climbing performance can be explained by a component consisting of trainable variables. More importantly, the findings do not support the belief that a climber must necessarily possess specific anthropometric characteristics to excel in sport rock climbing.

Adult↗

Diagnosis and management of asbestosis.

Asbestos-related illness usually arises at least 10 to 20 years after initial exposure. In many instances, patients may be unaware of the source of exposure. Although community-based exposures are unusual, recent events indicate that both communities and workers may have had significant exposure to asbestos contained within vermiculite. Physicians should obtain a medical history as outlined above when examining workers or community members who believe they have been significantly exposed to vermiculite. In addition, pulmonary function testing and chest radiographs should be obtained. If these are normal and there is no ongoing exposure, it is likely that no further evaluation is required. Physicians should have a radiologist familiar with occupational lung diseases read films. Patients may ask that a "B" reader, a physician who is certified by the National Institute for Occupational Safety and Health to read x-rays for changes related to the pneumoconioses, review their films. Facilitating smoking cessation and providing routine immunizations are important secondary preventive measures. Workers exposed to asbestos should receive ongoing screening as specified by the Occupational Safety and Health Administration. Over the last several decades, numerous epidemiologic studies have evaluated the efficacy of lung cancer screening. Period chest radiographs and sputum cytology have not been shown to increase lung cancer survival rates. Recent studies have demonstrated the potential benefit of scanning in the early detection of lung cancer. Although encouraging, these studies do not yet support the use of imaging for the routine screening of high-risk populations as required by the Occupational Safety and Health Administration.

Asbestosis↗

Synthesis and properties of 2-(naphthosultamyl)methyl-carbapenems with potent anti-MRSA activity: discovery of L-786,392.

A series of 1beta-methyl-2-(naphthosultamyl)methyl-carbapenems bearing dicationic groups on the naphthosultamyl moiety was prepared and evaluated for activity against resistant gram-positive bacteria. Based on a combination of excellent in vitro antibacterial activity, acceptable mouse acute toxicity, and a desirable fragmentation pattern on beta-lactam ring opening, the analog 2g (L-786,392) was selected for extended evaluation.