PubMed Health⌕ Search

PubMed · 11329200

Comparison of gradient encoding schemes for diffusion-tensor MRI.

Abstract

The accuracy of single diffusion tensor MRI (DT-MRI) measurements depends upon the encoding scheme used. In this study, the diffusion tensor accuracy of several strategies for DT-MRI encoding are compared. The encoding strategies are based upon heuristic, numerically optimized, and regular polyhedra schemes. The criteria for numerical optimization include the minimum tensor variance (MV), minimum force (MF), minimum potential energy (ME), and minimum condition number. The regular polyhedra scheme includes variations of the icosahedron. Analytical comparisons and Monte Carlo simulations show that the icosahedron scheme is optimum for six encoding directions. The MV, MF, and ME solutions for six directions are functionally equivalent to the icosahedron scheme. Two commonly used heuristic DT-MRI encoding schemes with six directions, which are based upon the geometric landmarks of a cube (vertices, edge centers, and face centers), are found to be suboptimal. For more than six encoding directions, many methods are able to generate a set of equivalent optimum encoding directions including the regular polyhedra, and the ME, MF and MV numerical optimization solutions. For seven directions, a previously described heuristic encoding scheme (tetrahedral plus x, y, z) was also found to be optimum. This study indicates that there is no significant advantage to using more than six encoding directions as long as an optimum encoding is used for six directions. Future DT-MRI studies are necessary to validate these observations. J. Magn. Reson. Imaging 2001;13:769-780.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K M Hasan, D L Parker, A L Alexander. 2001. Comparison of gradient encoding schemes for diffusion-tensor MRI.. https://doi.org/10.1002/jmri.1107

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗