PubMed Health⌕ Search

Biomedical subjects

D Liepsch

Publications and source records attributed to D Liepsch.

At least 37 records · Page 2Linked to original sources

Flow dynamics for radiologists. II. Practical considerations in the live human.

Although the rules about flows seem complex and even at times suggest chaos, some general principles can be extracted and used by the radiologist. Normal arteries damp disturbances, tolerate our catheters well, and generally cause the blood's slipstreams to swirl. It seems that the swirls and the energy that accompanies the passage of those swirls are prime determiners of the development of degenerative changes, most importantly of atherosclerosis and berry aneurysms. Knowing this, we now must direct our research to look beyond today's practical applications and this simplistic summary. Radiologists who trained during the angiography era are often incredulous when they see the richness of information found in physiologic flow models. For years, contrast agents have hidden the elegant complexity of blood flow. Now, however, we have two new powerful machines: the Doppler gray-scale ultrasound and the MR scanner. These machines routinely demonstrate flow data that we do not as yet use. As angiographers we have a natural and unconscious bias to make images produced by our new machines look like the classic angiogram. It is a powerful and pervasive bias. We still call angiography our "gold standard." We must overcome that bias. As valuable as angiography has been to radiology, it may no longer be our benchmark. A new standard is ready to be developed. The MR scanner even now not only allows calculation of global flow in vessels but also analyzes individual slipstreams. The images shown here are only the beginning. Keep our old mindset, and the limits and utility of the MR scanner will not be explored by radiologists. However, if we physicians, especially radiologists, reenter the field of fluid dynamics, all of science and our patients will benefit. We have broad shoulders to stand on and see into the future. Harvey, Hales, Galen, and Poiseuille: all were physicians; they added immeasurably to the foundations of rheology and our understanding of flowing blood. We must be willing to do likewise.

Aging↗

[Color-coded Doppler sonography of the male urethra: studies in vivo and experimental results].

The so-called ureter jet is a well known phenomenon, which consists of echoes due to turbulent urine flow emanating from the ureteral orifices during forced diuresis. These motion phenomena are also visible in colour Doppler examinations. In analogy to the ureter jet we could demonstrate different colour phenomena in the normal (n = 20) and stenosed (n = 14) male urethra during voiding by using colour coded Doppler sonography. These observations are obviously caused by turbulent urine flow. In an experimental study, this hypothesis could be verified. Because certain intraurethral colour phenomena are related to stenoses of the urethra, and because their intensity depends on the degree of stenosis and on urine flow (in ml/s), it seems to be possible to draw conclusions on the urodynamic consequences of a stenosis in the urethra by means of colour coded Doppler sonography.

Humans↗

[Orthotopic arteriovenous fistula in dialysis patients: a special application of fluid dynamic processes].

Our experiments describe the flow patterns in translucent models of AV fistulas. The elasticity of the models is similar to human vessels walls. Dying of particular flow threads with methylene blue visualizes the flow and its disturbances in 4 classical models. The flow dynamics were investigated with parallel inflow. The volume flow was constant at 200 and 400 ml/min, with a volume flow ratio of 80:20. The flow pattern in side to side fistulas and in end to side fistulas with a narrow angle show regions of separation. This may lead to microthrombus formation and early failure. High shear stress causes endothelial lesions and thus induces stenosing intimal reactions. A favourable flow pattern was seen in end to side fistulas with a broad angle, as well as in end to end fistulas.

Anastomosis, Surgical↗

Fundamental flow studies in models of human arteries.

Atherosclerosis is the principal cause of myocardial and cerebral infarction. Atherosclerotic lesions are present in localized regions of the vasculature where abrupt changes in vessel geometry occur, such as bends and bifurcations. In order to develop features of the risk profile, flow systems which simulate closely the pertinent anatomy and surface properties of the human vasculature are used with test fluids which mimic the physicochemical properties of blood. Analysis of the flow regimes were made by one-, two- or three-dimensional laser Doppler anemometry. Rigid and elastic model vessels with simple flow geometry as well as true-to-scale models of human arterial casts were used. Viscous pseudoplastic and viscoelastic fluid suspensions were employed under both steady and pulsatile flow. From the measured velocity profiles, the shear rates were estimated and with the local viscosity the shear stresses calculated. Flow behaviour was visualized using dyes and birefringent solutions. It was found that the geometry and flow rate ratio at bifurcations greatly influence the flow separation zones. It is also important to consider elasticity, pulsatility and non-Newtonian flow behavior in large blood vessels in zones where secondary flow is developed and flow separation zones are formed.

Arteries↗

Studies of fluids simulating blood-like rheological properties and applications in models of arterial branches.

We studied several non-Newtonian fluids to determine how closely they simulate the flow behavior of human blood. The viscous and viscoelastic properties of these fluids were compared with human blood samples in steady flow and transient flow Couette viscometers and in an oscillatory tube flow viscoelasticity analyzer. We examined: 1) A polyacrylamide suspension (Separan AP30 and AP45) to which we added 4% isopropanol and 0.01% magnesium chloride. 2) A suspension of 2% Dextran with 16% by weight biconcave disc-shaped particles simulating red blood cells. 3) 40% ghost cells prepared according to Dodge in Tri (hydroxymethyl) aminomethane. These ghost cells were used to simulate the two-phase flow behavior of blood. 4) A suspension of 5% Dextran (70,000) with 12% polystyrene particles (diameter of 1 micron) and 10 mMol calcium chloride. All these fluids closely approximate the flow behavior of blood and can be used in a variety of different experimental situations. To measure velocity distribution using a laser-Doppler-anemometer, we used fluids #1 and #3 in a rigid T-junction simulating the first septal branch of the left descending coronary artery. The measurements were done in steady and pulsatile flow experiments at different flow rate ratios. The fluids showed large differences in velocity profiles compared to Newtonian fluids.

Arteries↗

Flow visualization studies in a mold of the normal human aorta and renal arteries.

To study the flow behavior in regions where hemodynamic effects have been suggested to participate in atherogenesis, we evaluated flow in a mold of the aorta and renal arteries of a previously healthy 27-year-old woman who died of trauma. A birefringent solution (vanadium-pentoxide) was used. When diluted, this material behaves like a Newtonian fluid. This method gives a complete picture of the entire flow field. Zones of flow separation and disturbed flow can be seen and the location and size of disturbed areas observed. Unseparated flow regions downstream from disturbed zones can be properly visualized and the method can be used for pulsatile flow as well as steady flow. During steady flow (only at branch to-trunk flow ratios greater than 0.20), zones of flow separation were observed in the aorta distal to the renal arteries. During pulsatile flow, disturbances were found at nearly all branch-to-trunk flow ratios.

Aorta↗

Blood modeling using polystyrene microspheres.

The steady flow viscosity at shear rates 0 to 120 sec-1 and dynamic viscoelasticity at frequencies 0.02 to 0.8 Hz were determined for aqueous suspensions of uniform polystyrene microspheres of 1.0 micron diameter. Rheological properties of the microsphere suspensions were Newtonian for particle concentrations up to 32%. By introducing dextran and calcium chloride into the particle suspensions, non-Newtonian behavior was produced similar to that observed for human blood. The cooperative effects of dextran and calcium ions promoted aggregation of particles at a concentration as low as 12%. Thus, a suspension of uniform sized spherical polystyrene particles in aqueous solution of dextran may be made to mimic blood by controlling the surface charge on the polystyrene spheres using addition of calcium ions to the medium.

Blood↗

LDA measurements and numerical prediction of pulsatile laminar flow in a plane 90-degree bifurcation.

An experimental and numerical study of pulsatile laminar flow in a plane 90-degree bifurcation is presented. Detailed LDA velocity measurements of the oscillatory flow field have been carried out. The numerical predictions, which are based on an iterative, finite-difference numerical procedure using primitive dependent variables, are in good agreement with the measurements. The results show that one separation zone is established near the bottom wall of the main duct and another near the upstream wall of the branch. The location and size of the separation zones vary within the cycle and are influenced by the Reynolds number, the flow rate ratio, and the Stokes number.

Arteries↗

Haemodynamic stress in lateral saccular aneurysms. An experimental study.

The flow velocities in lateral glass and silastic aneurysm models were quantitatively measured with the non-invasive laser Doppler method. The influences of the elasticity of the wall, the pulse wave and the properties of the perfusion medium on the intra-aneurysmal circulation were investigated. As shown previously, the inflow into the aneurysm arose from the downstream lip and was directed toward the centre of the fundus. Backflow to the parent vessel took place along the walls of the fundus. With non-pulsatile perfusion, flow velocities in the centre of the standardized aneurysms varied between 0.4 and 2% of the maximum velocity in the parent vessel. With pulsatile perfusion, flow velocities in the centre of the fundus ranged between 8 and 13% of the flow velocity in the axis of the parent vessel. Flow velocities in the aneurysms were slower with a macromolecular perfusion medium with blood like properties compared to a glycerol/water solution. Flow velocity measurements near the aneurysmal wall allowed the estimation of the shear stresses at critical locations. The maximum shear stresses at the downstream lip of the aneurysm were in the range of the stresses measured at the flow divider of an arterial bifurcation. The present results suggest that in human saccular aneurysms intra-aneurysmal flow and shear stress on the wall are directly related to the pulsatility of perfusion, i.e. the systolic/diastolic pressure difference and that the tendency to spontaneous thrombosis depends on the viscoelastic properties of the blood, namely the haematocrit.

Blood Flow Velocity↗

Basic flow structure in saccular aneurysms: a flow visualization study.

Basic flow patterns were investigated in a set of glass aneurysm models by means of flow visualization methods. Dye injection and streaming double refraction were used to visualize flow. The circulation inside lateral aneurysms arising at a 90 degree angle from a straight parent conduit could not be visualized by the dye-injection technique but could be demonstrated by streaming double refraction. The inflow was seen to arise from the downstream lip of the orifice and to project to the dome of the aneurysm. Backflow to the parent conduit took place along the walls of the aneurysm. In aneurysms located at bifurcations, flow characteristics depended on the geometry of the bifurcation and the flow ratio between the branches. Relatively little intra-aneurysmal flow was demonstrated in side branch-related aneurysms arising distal to an asymmetric 90 degrees bifurcation of the type encountered at the junction of the internal carotid and posterior communicating arteries. Stagnation of flow at the neck and little intra-aneurysmal circulation were found with terminal aneurysms of the basilar bifurcation type if the outflow through the branches was symmetric. With asymmetric outflow, however, or if the axis of the aneurysm did not coincide with that of the afferent vessel, an active rotation developed in these aneurysms. The size of the aneurysm had no influence on the basic pattern of intra-aneurysmal circulation. The use of pulsatile perfusion did not significantly alter the basic flow patterns observed with steady flow. Locally disturbed laminar flow was observed in certain models at physiological Reynold's numbers, but there were no signs of fully developed turbulence.

Coloring Agents↗

The effects of non-Newtonian viscoelasticity and wall elasticity on flow at a 90 degrees bifurcation.

To study the fundamentals of hemodynamics in arteries, the flow parameters: pulsatility, elasticity and non-Newtonian viscoelasticity were considered in detail in a 90 degrees-T-bifurcation of a rigid and elastic model. The velocity distribution 2.5 mm behind the bifurcation in the straight tube was measured with a laser-Doppler-anemometer. The fluid used was an aqueous glycerine solution and a viscoelastic Separan mixture. Flow visualization studies were done with a sheet of laser light in the plane of the bifurcation. The velocity distribution was measured for both steady and pulsatile flows with a laser-Doppler-anemometer in a backward scattered way. From the velocity measurements the shear gradients were calculated. Substantial differences were found in the flow behavior of Newtonian and non-Newtonian fluids, especially behind the bifurcation in the main tube, where secondary flows and flow separation started. Also, differences due to the elastic and rigid wall could be seen. Very high shear gradients were found in the flow between main flow and the separation zone which can lead to a damage of the blood cells.

Arteries↗

Note on wave propagation in a thin elastic tube containing a viscous fluid.

This paper deals with the theoretical and experimental investigation of the propagation of pressure waves through a straight thin-walled elastic tube, filled with a streaming Newtonian fluid. The tube used was of silicon rubber and measured 200 mm in length, 8 mm in internal diameter and 1 mm in wall thickness. The velocity profiles across the diameter of the tube were measured at the beginning, at the middle and the end of the elastic pipe and compared with the results of a mathematical-computational model. The test data agree fairly well with the calculated values.

Diffusion↗

The effects of fluid-mechanical factors on MR imaging in the arterial model.

Blood flow is a significant factor in MR imaging. The purpose of this investigation was to study fluid-mechanical effects on MR imaging. MR images generated by the pulsatile flow of bovine blood in an elastic model of the aorta with both renal arteries were studied. The high-frequency pulse sequence was synchronized to an ECG trigger signal. It was demonstrated that different flow velocities, laminar and turbulent flow, and backward flow can be visualized with MR imaging.

Aorta↗

Pulsatile flow of non-Newtonian fluid in distensible models of human arteries.

In addition to biochemical factors, hydromechanical influences are responsible for atherogenesis and deposits of blood platelets at bends and bifurcations of human arteries. Hence the flow patterns were simulated in a true-to-scale three-dimensional bifurcation of a human renal artery model and of an arterial femoralis with Newtonian and non-Newtonian blood like fluid. Investigations were made with steady and pulsatile flow. The velocity profiles (at physiological Re-numbers) were measured after the bifurcations with a laser-Doppler-anemometer. In previous works Newtonian fluids were used to investigate the flow in bends and bifurcations of rigid and elastic simplified models. In this paper, emphasis is placed on the difference between rigid and elastic models and also Newtonian and non Newtonian flow behavior. Differences between Newtonian and non Newtonian fluids may especially be expected to occur after branches where the flow has local strong convective elements such as in reverse zones and flow separation points.

Arteries↗

Flow investigations in a model of a three-dimensional human artery with Newtonian and non-Newtonian fluids. Part I.

Together with biochemical factors, fluid mechanical factors play a role in atherogenesis and the deposition of blood platelets at bends and bifurcations in human arteries. Hence, flow patterns were investigated in a simplified 3-dimensional model of a human renal artery bifurcation using Newtonian (aqueous glycerol) and non-Newtonian (aqueous solution of polyacrylamide) fluids. Studies were carried out in steady as well as pulsatile flow at inflow Reynolds numbers of 498 and 951 with flow rate ratios main tube V1: right branch V4: left branch V3 of 1: 0.25: 0.25 and 1: 0.18: 0.18 respectively. The velocity distribution proximal and distal to the bifurcations was measured using a laser-Doppler anemometer. In steady flow, zones of flow separation and reverse flow were observed distal to the bifurcations. In pulsatile flow using non-Newtonian fluids, there was a significant enlargement of these zones. Differences between the Newtonian and non-Newtonian fluids occurred especially distal to the bifurcations. Shear stresses along all measuring positions were computed from the velocity gradients.

Acrylic Resins↗

Measurement and calculations of laminar flow in a ninety degree bifurcation.

Measurements and numericaL calculations of laminar flow in a plane 90 degrees bifurcation are presented. The corresponding two-dimensional steady flow Navier-Stokes equations solved by a finite-difference procedure employing pressure and velocity as dependent variables. The influence of Reynolds number and mass flow ratio on the velocity field, streamlines, local shear stress and pressure drop are quantified and shown to be substantial. The circulation patterns and shear stresses are examined in view of available data regarding the formation of atherotic plaques in the human circulatory system. The calculated velocity profiles are compared with measurements obtained with laser Doppler anemometry and the agreement is shown to be satisfactory. Calculations outside the range of measurements which are of value to biomechanics are also presented.

Blood Flow Velocity↗