PubMed Health⌕ Search

Biomedical subjects

D Nikezic

Publications and source records attributed to D Nikezic.

At least 19 recordsLinked to original sources

Killing of target cells due to radon progeny in the human lung.

The dose conversion coefficient (DCC) is used to assess the risk due to inhaled radon progeny in the human lung. The present work uses the microdosimetric approach and determines the linear energy transfer in the target cell nuclei. Killing of target cells was also taken into account through an effect-specific track length model. To focus on the relevant part of the absorbed dose in the cell nuclei, the absorbed dose, which causes cell-killing is discarded in the final calculations of the DCC. Following this approach, the calculated DCC has become 3.4 mSv WLM(-1) which is very close to the epidemiologically derived value of approximately 4 mSv WLM(-1).

Aerosols↗

Alpha-particle radiobiological experiments using thin CR-39 detectors.

The present paper studied the feasibility of applying comet assay to evaluate the DNA damage in individual HeLa cervix cancer cells after alpha-particle irradiation. We prepared thin CR-39 detectors (<20 microm) as cell-culture substrates, with UV irradiation to shorten the track formation time. After irradiation of the HeLa cells by alpha particles, the tracks on the underside of the CR-39 detector were developed by chemical etching in (while floating on) a 14 N KOH solution at 37 degrees C. Comet assay was then applied. Diffusion of DNA out of the cells could be generally observed from the images of stained DNA. The alpha-particle tracks corresponding to the comets developed on the underside of the CR-39 detectors could also be observed by just changing the focal plane of the confocal microscope.

Alpha Particles↗

Derivation of V function for LR 115 SSNTD from its partial sensitivity to 222Rn and its short-lived progeny.

Solid-state nuclear track detectors (SSNTDs) have been widely applied for measurements of environmental concentrations of 222Rn and its progeny. The V function for an SSNTD is important for understanding the track development in the SSNTD as well as for real life applications. The partial sensitivity rhoi of the LR 115 detector applied in the bare mode to 222Rn and its short-lived progeny is related to the equilibrium factor F through the proxy equilibrium factor Fp. On the other hand, rhoi is also dependent on the removed active layer thickness during chemical etching, which is related to the V function for the LR 115 detector. In the present paper, the experimentally obtained rhoi values of the LR 115 detector for different removed active layer thickness are used to derive the V function for the LR 115 SSNTD, which took the form of the Durrani--Green's function, i.e., [formula: see text] , with the best-fitted constants as a1=14.23; a2=0.48; a3=5.9 and a4=0.077 (a5=1).

Alpha Particles↗

Derivation of V function for LR 115 SSNTD from its sensitivity to 220Rn in a diffusion chamber.

The sensitivity of the LR 115 detector inside a diffusion chamber to (220)Rn gas concentration is dependent on the removed active layer thickness during chemical etching. This dependence is related to the V function for the LR 115 detector (where V is the ratio between the track etch velocity V(t) and the bulk etch velocity V(b)) and the geometry of the diffusion chamber. The present paper presents the experimentally determined relationship between the sensitivity of the LR 115 detector inside a Karlsruhe diffusion chamber (determined from the number of etched tracks completely penetrating the active cellulose nitrate layer) and the removed active layer thickness. These data were used to derive the V function for the LR 115 detector, which took the functional form of the Durrani-Green's function, i.e., V=1+((a1e-)(a2R+a3e(-a)4R))(1(-e)(-a5R)), with the best-fitted constants as a(1)=14.50, a(2)=0.50, a(3)=3.9 and a(4)=0.066.

Journal Article↗

Comparison of dose conversion factors for radon progeny from the ICRP 66 regional model and an airway tube model of tracheo-bronchial tree.

Current epidemiological approaches to radon dosimetry yield a dose conversion factor (DCF) of 4 mSv WLM(-1) while the dosimetric approaches give a value closer to 13 mSv WLM(-1). The present study investigated whether the application of compartment models for the bronchial (BB) and bronchiolar (bb) regions, rather than more anatomically realistic airway tube models, has brought the dosimetric DCF to the higher values. The airway tube model of the tracheo-bronchial tree was used to calculate the effective dose per unit radon exposure. All other elements of the human respiratory tract from the reports of the ICRP or NRC were adopted. A dosimetric derivation of the radon DCF using the airway tube model yielded a value of 14.2 mSv WLM(-1). This value is slightly larger than, but not significantly different from, the result obtained through the ICRP 66 approach. It is concluded that utilization of the airway tube model instead of the regional ICRP 66 compartmental model cannot reconcile the gap between dose conversion factors derived from epidemiological and dosimetric approaches.

Air Pollutants, Radioactive↗

Absorbed dose in target cell nuclei and dose conversion coefficient of radon progeny in the human lung.

To calculate the absorbed dose in the human lung due to inhaled radon progeny, ICRP focussed on the layers containing the target cells, i.e., the basal and secretory cells. Such an approach did not consider details of the sensitive cells in the layers. The present work uses the microdosimetric approach and determines the absorbed alpha-particle energy in non-spherical nuclei of target cells (basal and secretory cells). The absorbed energy for alpha particles emitted by radon progeny in the human respiratory tract was calculated in basal- and secretory-cell nuclei, assuming conical and ellipsoidal forms for these cells. Distributions of specific energy for different combinations of alpha-particle sources, energies and targets are calculated and shown. The dose conversion coefficient for radon progeny is reduced for about 2mSv/WLM when conical and ellipsoidal cell nuclei are considered instead of the layers. While changes in the geometry of secretory-cell nuclei do not have significant effects on their absorbed dose, changes from spherical to conical basal-cell nuclei have significantly reduced their absorbed dose from approximately 4 to approximately 3mGy/WLM. This is expected because basal cells are situated close to the end of the range of 6MeV alpha particles. This also underlines the significance of better and more precise information on targets in the T-B tree. A further change in the dose conversion coefficient can be achieved if a different weighting scheme is adopted for the doses for the cells. The results demonstrate the necessity for better information on the target cells for more accurate dosimetry for radon progeny.

Humans↗

Assessment of environmental radon hazard using human respiratory tract models.

Radon is a natural radioactive gas derived from geological materials. It has been estimated that about half of the total effective dose received by human beings from all sources of ionizing radiation is attributed to 222Rn and its short-lived progeny. In this paper, the use of human respiratory tract models to assess the health hazard from environmental radon is reviewed. A short history of dosimetric models for the human respiratory tract from the International Commission on Radiological Protection (ICRP) is first presented. The most important features of the newest model published by ICRP in 1994 (as ICRP Publication 66) are then described, including the morphometric model, physiological parameters, radiation biology, deposition of aerosols, clearance model and dose weighting. Comparison between different morphometric models and comparison between different deposition models are then given. Finally, the significance of various parameters in the lung model is discussed, including aerosol parameters, subject related parameters, target and cell related parameters, and parameters that define the absorption of radon from the lungs to blood. Dosimetric calculations gave a dose conversion coefficient of 15 mSv/WLM, which is higher than the value 5 mSv/WLM derived from epidemiological studies. ICRP stated that dosimetric models should only be used for comparison of doses in the human lungs resulted from different exposure conditions.

Aerosols↗

Are radon gas measurements adequate for epidemiological studies and case control studies of radon-induced lung cancer?

The lung dose derived from radon is not attributed to the radon gas itself, but instead to its short-lived progeny. However, in many epidemiological studies as well as in case control studies of the radon risk, the excess number of cancers are related to the radon gas exposure, and not to the radon progeny exposure. A justification for such an approach has resorted to the assumption that there is self-compensation between the radiation doses from the unattached and attached fractions. In the present study, we used the Jacobi model to calculate the radon progeny concentrations in a room by varying the attachment rate and then calculated the resulting lung dose. It was found that self-compensation was not fully realised, and the effective dose can vary by a factor up to approximately 2 for the same radon gas concentration. In conclusion, the radon gas concentration alone does not provide adequate information on the effective dose.

Algorithms↗

Theoretical basis for long-term measurements of equilibrium factors using LR 115 detectors.

In this paper, we propose a method to determine the equilibrium factor using a bare LR 115 detector. The partial sensitivities rhoi of the LR 115 detector to 222Rn and its alpha-emitting short-lived progeny, 218Po and 214Po, were investigated. We first determined the distributions of lengths of major and minor axes of the perforated alpha tracks in the LR 115 detector produced by 222Rn, 218Po and 214Po through Monte Carlo simulations. The track parameters were calculated using a track development model with a published V function, by assuming a removed active layer of 6.54 microm. The distributions determined for different alpha emitters were found to completely overlap with one another. This implied equality of partial sensitivities for radon and its progeny, which was also confirmed through analytical considerations. Equality of partial sensitivities makes possible convenient measurements of the proxy equilibrium factor Fp, which is defined in the present work as (F1+F3) and is equal to the ratio between the sum of concentrations of the two alpha emitting radon progeny (218Po+214Po) to the concentration of radon gas (222Rn). In particular, we have found Fp = (rho/rhoitC0)-1, where rho (track/m2) is the total track density on the detector, rhoi = 0.288 x 10(-2) m, t is the exposure time and C0 (Bq/m3) is the concentration of 222Rn. If C0 is known (e.g. from a separate measurement), we can obtain Fp. The proxy equilibrium factor Fp is also found to be well correlated with the equilibrium factor between radon gas and its progeny through the Jacobi room model. This leads to a novel method for long-term determination of the equilibrium factor.

Journal Article↗

Influence of variability of 214Pb recoil factor on lung dose.

Different parameters enter models of the human respiratory tract. The unattached fraction of the radon progeny was identified as the most important parameter, with the strongest influence on lung dose. The unattached fraction depends on the indoor aerosol concentration and other environmental conditions. The recoil factor, p, which influences the unattached fraction of 214Pb and 214Bi, defined as the average detachment probability from the aerosol after an alpha decay of 218Po, has almost always been taken as a constant. Here the recoil factor was recalculated under different assumptions and found to be in the range between 0.1 and 0.8. A smaller recoil factor means lower unattached fractions of 214Pb and 214Bi. The influence of the recoil factor on lung dose was also estimated. The lung dose is smaller by about 10% if p = 0.1 is assumed in calculating the unattached fraction instead of p = 0.8.

Aerosols↗

Measurement of parameters of tracks in CR-39 detector from replicas.

In determining the etched track rate in solid-state nuclear track detectors, track lengths should be determined accurately. A method based on surface profilometry is proposed to determine the track lengths in CR-39 detectors through measurements of their replicas. Tracks from alpha particles with an incident energy of 4 MeV have been chosen to demonstrate the method. After irradiation and chemical etching, resin replicas were made from the tracks, of which the heights were measured by the Form Talysurf PGI Profilometer. The results showed that the surface of the replicas were smooth and the heights of the replicas were uniform, so the replicating fluid should have filled the tracks completely and the replicas truly reflected the dimensions of the tracks. The heights of the replicas were conveniently determined from the lateral view of the replicas generated by the Form Talysurf PGI Profilometer.

Alpha Particles↗

Absorbed fraction of alpha-particles emitted in bifurcation regions of the human tracheo-bronchial tree.

A model for bifurcation regions of the human tracheo-bronchial tree was developed. Equations for the surfaces are given to enable calculations of doses from alpha-particles emitted in these regions. It has been found that a bifurcation region is well approximated by a quasi-ellipsoid. The absorbed fractions of alpha-particles emitted in bifurcation regions were calculated by the Monte Carlo method. The average absorbed fraction under the bifurcation geometry is close to that found under the cylindrical geometry in the bronchial region. In the bronchiolar region, the absorbed fractions under the bifurcation geometry are up to 20% larger than those under the cylindrical geometry.

Air Pollutants, Radioactive↗

Deposition fractions of 218Po in diffusion chambers.

After radon gas diffuses into a diffusion chamber, 218Po will be formed. Due to its short half-life, a fraction f of 218Po decays before deposition onto available inner surfaces of the chamber, and the deposition fraction (1-f) represents the part which decays after deposition. In the present work, f has been experimentally determined for six diffusion chambers with different materials and dimensions using the radial distribution of track density on the LR115 detectors inside the diffusion chambers. For all the six studied diffusion chambers, f was found to be approximately 0.4. Therefore, the deposition fraction does not depend on the shape and dimensions of the diffusion chambers, the surface to volume ratios or the internal surface materials of the diffusion chambers.

Journal Article↗

Absorbed fraction of radon progeny in human bronchial airways with bifurcation geometry.

PURPOSE: The absorbed fraction, defined as the portion of the initial particle energy which is absorbed in the tissue of interest, was calculated, under bifurcation geometry of the airway tubes, for alpha-particles emitted from radon progeny in the human respiratory tract. The results are given for all branching generations and compared with the data obtained for the commonly used infinite straight cylinders adopted by the International Commission on Radiological Protection (ICRP) Report 66. MATERIALS AND METHODS: A model was created to calculate the absorbed fraction of alpha-particle energy in the human lung using bifurcation geometry. Monte Carlo simulations of alpha-particle propagation in tissue and air were performed. The stopping powers of alpha-particles were adopted from the International Commission of Radiation Units and Measurements (ICRU) Report 49. RESULTS: The absorbed fractions for the bifurcation geometry are given for the 15 generations in the tracheobronchial tree for alpha-particle energies of 6 and 7.69 MeV. The sources were assumed to be the fast and slow moving mucus. CONCLUSIONS: Comparisons with ICRP66 data reveal that the assumption of long, straight cylinders was appropriate in some cases, but not in all. Adoption of the absorbed fractions obtained from the bifurcation model instead of the ICRP66 data caused 'redistribution' of doses in the bronchial (BB) and bronchiolar (bb) regions.

Bronchi↗

Quality factors for alpha particles in the human respiratory tract.

Quality factors of alpha particles emitted by radon progeny in the human lung have been calculated by using the formula recommended by the International Commission on Radiological Protection. Calculations have been carried out for different combinations of sources, energies, and targets. The values obtained are between 20 and 26, with an average of about 24. These are comparable to previously published results for the human lung and for the general consideration of alpha particles emitted in tissue.

Alpha Particles↗

Absorbed dose delivered by alpha particles calculated in cylindrical geometry.

The present work aims to develop a semi-analytical method to calculate the absorbed dose delivered by alpha particles in a cylindrical geometry. This method will be employed to reproduce the dose conversion coefficients or absorbed fraction of alpha particles in sensitive cells of the tracheobronchial tree obtained by NRC and ICRP, respectively. The difference caused by using water stopping power and tissue stopping power will also be investigated. Linear stopping powers for alpha particles in tissue and air were calculated, and the dependences of stopping powers on the traveled distance were established. A geometry model is set up for our calculations, and two different cases have been considered, namely the near-wall and far-wall cases. The total energy imparted to a unit-diameter sphere around a point is shown to be obtainable from a triple integral, which can be solved numerically. The absorbed dose is found to be independent of the diameter of the sphere being considered and additional assumptions about its diameter were not needed. The results obtained are in good agreement with those obtained previously by NRC and ICRP66. Using the semi-analytical method developed in the present work, the dose conversion coefficients or absorbed fraction previously obtained by NRC and ICRP, respectively, have been satisfactorily reproduced. Using the tissue stopping power instead of the water stopping power can slightly lower the values for dose conversion coefficients in the bronchial region.

Absorption↗

Effects of different deposition models on the calculated dose conversion factors from 222Rn progeny.

Regional lung deposition for radon progeny (size range, 1 nm to 1000 nm, monodispersed) has been determined employing Gormley-Kennedy, Ingham, Cohen-Asgharian and Yu-Cohen expressions (which describe diffusion deposition), together with Gurman and Cheng formulae for impaction and sedimentation, respectively. The deposition values have been compared with those obtained by using the algebraic expressions recommended by ICRP66. The behavior of the deposition curves for breathing rates of 0.45, 0.78 and 1.2 m3 h(-1) are similar, with a broad maximum in the range (1-100) nm. In the particle size range (1-100) nm, where the thermodynamic efficiency predominates, there are large differences among the five approaches, with ICRP values lying somewhat in the middle. Dose Conversion Factors nearly follow the regional deposition trends, Cohen-Asgharian and Ingham, close to the highest values, Yu-Cohen the lowest and ICRP, again, somewhat in the middle.

Humans↗