Gradient echo acquisition for superparamagnetic particles with positive contrast (GRASP): sequence characterization in membrane and glass superparamagnetic iron oxide phantoms at 1.5T and 3T.

Iron oxides are used for cell trafficking and identification of macrophages in plaque using MRI. Due to the negative contrast, differentiation between signal loss caused by iron and native low signal in tissue may be problematic. It is, therefore, preferable to achieve positive contrast. The purpose of this study was to test the efficacy of a new MRI sequence GRASP (GRe Acquisition for Superparamagnetic Particles) to generate a positive signal in phantoms containing iron. Membrane phantoms were constructed containing Ferumoxide at 7 concentrations. Standard GRE sequences were modified with user controlled z-gradient rephasing (+/- 100%). CNR values were determined as a function of echo time (TE) and % rephasing at 1.5T and 3T. T(2)* values were determined using multiple double-echo GRE. The GRASP sequence generated positive signal enhancement in phantoms containing iron. For all rephasing values <or=30%, positive contrast was observed. The CNR generated at 1.5T was greater than the values at 3T for all concentrations tested. Correlation between CNR at 0% and 100% rephasing was observed at 1.5T(R = 0.84). Additionally, correlation between field change across the volume and CNR was observed. In conclusion, GRASP sequences may be used to generate positive signal enhancement in the presence of iron using MRI.

Artifacts↗

Carotid black blood MRI burden of atherosclerotic disease assessment correlates with ultrasound intima-media thickness.

The aim of this study was to correlate carotid black blood MRI based measurements with those obtained by ultrasound intima-media thickness (IMT). Seventeen patients with intermediate to high Framingham cardiovascular risk score underwent both carotid ultrasound and rapid extended coverage double inversion recovery black blood carotid MRI. Overall, there was good correlation between wall area, wall thickness, and plaque index measured by MRI and the IMT measurements obtained from the ultrasound images (max r2 = 0.72, p < 0.05). Patients with mean IMT > or = 1.2 mm had significantly higher values of wall area, plaque index and wall thickness compared to patients with mean IMT < 1.2 mm. Vessel wall measurements assessed by black-blood MRI may be potentially used clinically to evaluate plaque progression and regression.

Aged↗

Comparison of gated and non-gated fast multislice black-blood carotid imaging using rapid extended coverage and inflow/outflow saturation techniques.

PURPOSE: To comparatively analyze two fast in vivo multislice black-blood carotid artery vessel wall imaging techniques with and without cardiac gating. MATERIALS AND METHODS: Eight subjects with carotid artery atherosclerosis, and four healthy subjects were studied using two black-blood multislice techniques: rapid extended coverage double inversion recovery (REX-DIR), and inflow/outflow saturation band (IOSB) rapid acquisition with relaxation enhancement (RARE) multislice acquisitions. Quantitative, qualitative, and morphometric analyses were performed on images. RESULTS: Gating produced significantly lower values for the REX-DIR sequence with respect to signal intensity in muscle and the carotid artery wall, whereas it had no effect on flow suppression compared to non-gated images. For the IOSB sequences, gating had no significant effect on signal intensity of muscle and the carotid artery wall, but worsened flow suppression. REX-DIR and IOSB sequences were statistically different with respect to signal intensity of muscle (with REX-DIR sequences having lower values), while no statistical significance was observed for flow suppression and wall delineation. A morphologic analysis of the vessel wall and lumen comparing REX-DIR gated, IOSB gated, REX-DIR non-gated, and IOSB non-gated sequences revealed no significant differences between the acquisition techniques tested. CONCLUSION: Non-gated sequences may be used instead of gated sequences in atherosclerotic vessel wall imaging without compromising image quality. This may shorten examination time and improve patient comfort.

Adolescent↗

Parallel and nonparallel simultaneous multislice black-blood double inversion recovery techniques for vessel wall imaging.

PURPOSE: To reduce long examination times of black-blood vessel wall imaging by acquiring multiple slices simultaneously and by using parallel acquisition techniques. MATERIALS AND METHODS: DIR-rapid acquisition with relaxation enhancement (RARE) techniques imaging up to 10 simultaneous slices per acquisition with single and multiple 180 degrees -reinversion pulses were developed. A slab-selective reinversion multislice DIR-RARE sequence incorporating generalized autocalibrating partially parallel acquisitions (GRAPPA) imaging was implemented. Four-channel and eight-channel carotid coils were built to test these sequences. A total of 11 subjects were studied. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) efficiency factor (SEF, SNR/unit time/slice) were measured from aortic images of three healthy subjects to determine optimal MR parameters. The DIR-RARE-GRAPPA sequence was run on aortas and carotid arteries of the five remaining healthy subjects and three atherosclerotic patients with optimal parameters (acquisition times 12-21 seconds). RESULTS: SEFs of slab-selective protocols were significantly higher than those of slice-selective protocols, and SEFs of DIR-RARE-GRAPPA protocols were significantly higher than corresponding non-GRAPPA protocols (P < 0.05). CNR was not significantly different for all imaging protocols. The DIR-RARE-GRAPPA multislice sequence showed 8.35-fold time improvement vs. single-slice DIR-2RARE sequence. CONCLUSION: Future MRI atherosclerotic plaque studies can be performed in substantially shorter times using these methods.

Adult↗

Quantification of human atherosclerotic plaques using spatially enhanced cluster analysis of multicontrast-weighted magnetic resonance images.

One of the current limitations of magnetic resonance imaging (MRI) is the lack of an objective method to classify plaque components. Here we present a cluster analysis technique that can objectively quantify and classify MR images of atherosclerotic plaques. We obtained three-dimensional (3D) images from 12 human coronary artery specimens on a 9.4T imaging system using multicontrast-weighted fast spin-echo (T1-, proton density-, and T2-weighted) imaging with an isotropic voxel size of 39 micro. Spatially enhanced cluster analysis (SECA) was performed on multicontrast MR images, and the resulting segmentation was evaluated against histological tracings. To visualize the overall structure of plaques, the MR images were rendered in 3D. The specimens exhibited lesions of American Heart Association (AHA) plaque classification types I-VI. Both MR images and histological sections were independently reviewed, categorized, and compared. Overall, the classification obtained from the cluster-analyzed MR and histopathology images showed very good agreement for all AHA types (92%, Cohen's kappa = 0.89, P < 0.0001). All plaque types were identified and quantified by SECA with a high degree of correlation between cluster-analyzed MR and manually traced histopathology data. MRI combined with SECA provides an objective method for atherosclerotic plaque component characterization and quantification.

Analysis of Variance↗

Rapid extended coverage simultaneous multisection black-blood vessel wall MR imaging.

A two-dimensional rapid extended coverage (REX) rapid acquisition with relaxation enhancement (RARE) pulse sequence for simultaneous multisection double inversion-recovery (DIR) black-blood vessel wall magnetic resonance (MR) imaging was developed. Aortic vessel wall MR imaging was performed in five healthy subjects (mean age, 33 years +/- 4 [SD]) and five patients with atherosclerotic disease (mean age, 67 years +/- 11.7). Shortening of blood inversion time and imaging of multiple sections after single DIR block resulted in simultaneous acquisition of up to 20 aortic wall sections in less than 1 minute (spatial resolution, 0.97 x 0.97 x 3 mm(3)). Higher signal-to-noise ratios per unit time per section (16.0 +/- 2.45 vs 7.5 +/- 1.10, P <.05), no significant changes in contrast-to-noise ratios (15.0 +/- 5.3 vs 20.1 +/- 3.9, P >.05), and 17-fold improvement in acquisition time compared with those at conventional single-section DIR RARE imaging was achieved. Use of the REX method significantly shortened aortic imaging acquisition times without degrading image quality.

Adult↗

Magnetic resonance microscopy quantifies the disease progression in Marfan syndrome mice.

PURPOSE: To use noninvasive magnetic resonance microscopy (MRM) to examine aneurysmal disease in the mouse model of Marfan syndrome (MFS). MATERIALS AND METHODS: A total of eight wild-type (WT) and MFS mice were imaged using MRM; four of them at three different time points over an 8-week period and the remaining animals were imaged at one time point. The maximal cross-sectional area of the aorta was measured by manual tracing and by automated means from combined cardiac and respiratory-gated bright-blood images. Relationships between aortic size and age and the differences between WT and mutant mice aortic size were established. RESULTS: Maximal cross-sectional aortic areas differed significantly (P < 0.05) between WT and mutant mice for all time points, with MFS mice having larger aortic size. There was a positive correlation between aortic size and age in MFS mice (r = 0.80) with a significant increase from the 14th to the 22nd week (P < 0.05). CONCLUSION: MRM detected the differences in aortic size between WT and mutant mice over time, demonstrating a potential for noninvasive technique for the assessment of potential therapies in MFS mice.

Analysis of Variance↗