32-element receiver-coil array for cardiac imaging.

A lightweight 32-element MRI receiver-coil array was designed and built for cardiac imaging. It comprises an anterior array of 21 copper rings (75 mm diameter) and a posterior array of 11 rings (107 mm diameter) that are arranged in hexagonal lattices so as to decouple nearest neighbors, and curved around the left side of the torso. Imaging experiments on phantoms and human volunteers show that it yields superior performance relative to an eight-element cardiac array as well as a 32-element whole-torso array for both traditional nonaccelerated cardiac imaging and 3D parallel imaging with acceleration factors as high as 16.

Algorithms↗

Toward single breath-hold whole-heart coverage coronary MRA using highly accelerated parallel imaging with a 32-channel MR system.

Coronary MR angiography (CMRA) is generally confined to the acquisition of multiple targeted slabs with coverage dictated by the competing constraints of signal-to-noise ratio (SNR), physiological motion, and scan time. This work addresses these obstacles by demonstrating the technical feasibility of using a 32-channel coil array and receiver system for highly accelerated volumetric breath-hold CMRA. The use of the 32-element array in unaccelerated CMRA studies provided a baseline SNR increase of as much as 40% over conventional cardiac-optimized phased array coils, which resulted in substantially enhanced image quality and improved delineation of the coronary arteries. Modest accelerations were used to reduce breath-hold durations for tailored coverage of the coronary arteries using targeted multi-oblique slabs to as little as 10 s. Finally, high net accelerations were combined with the SNR advantages of a 3D steady-state free precession (SSFP) technique to achieve previously unattainable comprehensive volumetric coverage of the coronary arteries in a single breath-hold. The merits and limitations of this simplified volumetric imaging approach are discussed and its implications for coronary MRA are considered.

Coronary Angiography↗

An introduction to coil array design for parallel MRI.

The basic principles of radiofrequency coil array design for parallel MRI are described from both theoretical and practical perspectives. Because parallel MRI techniques rely on coil array sensitivities to provide spatial information about the sample, a careful choice of array design is essential. The concepts of coil array spatial encoding are first discussed from four qualitative perspectives. These qualitative descriptions include using coil arrays to emulate spatial harmonics, choosing coils with selective sensitivities to aliased pixels, using coil sensitivities with broad k-space reception profiles, and relying on detector coils to provide a set of generalized projections of the sample. This qualitative discussion is followed by a quantitative analysis of coil arrays, which is discussed in terms of the baseline SNR of the received images as well as the noise amplifications (g-factor) in the reconstructed data. The complications encountered during the experimental evaluation of coil array SNR are discussed, and solutions are proposed. A series of specific array designs are reviewed, with an emphasis on the general design considerations that motivate each approach. Finally, a set of special topics is discussed, which reflect issues that have become important, especially as arrays are being designed for more high-performance applications of parallel MRI. These topics include concerns about the depth penetration of arrays composed of small elements, the use of adaptive arrays for systems with limited receiver channels, the management of inductive coupling between array elements, and special considerations required at high field strengths. The fundamental limits of spatial encoding using coil arrays are discussed, with a primary emphasis on how the determination of these limits impacts the design of optimized arrays. This review is intended to provide insight into how arrays are currently used for parallel MRI and to place into context the new innovations that are to come.

Algorithms↗

Parallel imaging in cardiovascular MRI: methods and applications.

Cardiovascular MR imaging (CVMR) has become a valuable modality for the non-invasive detection and characterization of cardiovascular diseases. CVMR requires high imaging speed and efficiency, which is fundamentally limited in conventional cardiovascular MRI studies. With the introduction of parallel imaging, alternative means for increasing acquisition speed beyond these limits have become available. In parallel imaging some image data are acquired simultaneously, using RF detector coil sensitivities to encode simultaneous spatial information that complements the information gleaned from sequential application of magnetic field gradients. The resulting improvements in imaging speed can be used in various ways, including shortening long examinations, improving spatial resolution and/or anatomic coverage, improving temporal resolution, enhancing image quality, overcoming physiological constraints, detecting and correcting for physiologic motion, and streamlining work flow. Examples of each of these strategies will be provided in this review. First, basic principles and key concepts of parallel MR are described. Second, practical considerations such as coil array design, coil sensitivity calibrations, customized pulse sequences and tailored imaging parameters are outlined. Next, cardiovascular applications of parallel MR are reviewed, ranging from cardiac anatomical and functional assessment to myocardial perfusion and viability to MR angiography of the coronary arteries and the large vessels. Finally, current trends and future directions in parallel CVMR are considered.

Algorithms↗

Parallel magnetic resonance imaging with adaptive radius in k-space (PARS): constrained image reconstruction using k-space locality in radiofrequency coil encoded data.

A parallel image reconstruction algorithm is presented that exploits the k-space locality in radiofrequency (RF) coil encoded data. In RF coil encoding, information relevant to reconstructing an omitted datum rapidly diminishes as a function of k-space separation between the omitted datum and the acquired signal data. The proposed method, parallel magnetic resonance imaging with adaptive radius in k-space (PARS), harnesses this physical property of RF coil encoding via a sliding-kernel approach. Unlike generalized parallel imaging approaches that might typically involve inverting a prohibitively large matrix for arbitrary sampling trajectories, the PARS sliding-kernel approach creates manageable and distributable independent matrices to be inverted, achieving both computational efficiency and numerical stability. An empirical method designed to measure total error power is described, and the total error power of PARS reconstructions is studied over a range of k-space radii and accelerations, revealing "minimal-error" conditions at comparatively modest k-space radii. PARS reconstructions of undersampled in vivo Cartesian and non-Cartesian data sets are shown and are compared selectively with traditional SENSE reconstructions. Various characteristics of the PARS k-space locality constraint (such as the tradeoff between signal-to-noise ratio and artifact power and the relationship with iterative parallel conjugate gradient approaches or nonparallel gridding approaches) are discussed.

Algorithms↗

Inherently self-calibrating non-Cartesian parallel imaging.

The use of self-calibrating techniques in parallel magnetic resonance imaging eliminates the need for coil sensitivity calibration scans and avoids potential mismatches between calibration scans and subsequent accelerated acquisitions (e.g., as a result of patient motion). Most examples of self-calibrating Cartesian parallel imaging techniques have required the use of modified k-space trajectories that are densely sampled at the center and more sparsely sampled in the periphery. However, spiral and radial trajectories offer inherent self-calibrating characteristics because of their densely sampled center. At no additional cost in acquisition time and with no modification in scanning protocols, in vivo coil sensitivity maps may be extracted from the densely sampled central region of k-space. This work demonstrates the feasibility of self-calibrated spiral and radial parallel imaging using a previously described iterative non-Cartesian sensitivity encoding algorithm.

Algorithms↗

Concentric coil arrays for parallel MRI.

A new type of coil array is proposed that consists of concentrically placed coil elements, each of which is characterized by symmetrically arranged lobes that have alternating current directions. Symmetries in the coil elements' conductor paths allow for the minimization of mutual inductance and noise correlations. In addition, the concentric arrangement of the coil elements provides spatial encoding capabilities in multiple directions, which is valuable when arrays are used with parallel MRI. Simulations are presented that describe the signal-to-noise ratio (SNR) properties of individual concentric array elements, and a four-element prototype concentric array is constructed. This prototype array is compared experimentally with three alternative four-element array designs. The overall SNR of the concentric array is comparable to the SNR of the competing arrays. Reconstruction of twofold undersampled data using the concentric array yields an average g-factor of less than 1.3 in all directions parallel to the plane of the array. There is some degradation in performance when threefold undersampled data are reconstructed, but the array still shows substantial directional invariance compared to alternative designs. Both fully-sampled and undersampled cardiac images acquired using the concentric array are shown. These results suggest that concentric structures can be useful tools for designing specialized coil arrays for parallel MRI.

Computer-Aided Design↗

Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: feasibility and implications.

RATIONALE AND OBJECTIVES: Many clinical applications of Magnetic Resonance Imaging are constrained by basic limits on imaging speed. Parallel MRI relaxes these limits by using the sensitivity patterns of arrays of radiofrequency receiver coils to encode spatial information in a manner complementary to traditional encoding with magnetic field gradients. Until now, parallel MRI has been used to achieve modest improvements in imaging speed; order-of-magnitude improvements have been elusive given fundamental losses in signal-to-noise ratio. The goal of this work was to demonstrate that, with appropriate hardware and careful SNR management, rapid volumetric imaging at high accelerations is in fact feasible. MATERIALS AND METHODS: Contrast-enhanced MRI with an axial 3D spoiled gradient echo imaging sequence was performed in healthy adult subjects using a 32-element RF coil array and a prototype 32-channel MR imaging system. Large imaging volumes were prescribed, in place of traditional limited slabs targeted only to suspect regions. RESULTS: As much as 16-fold net accelerations of imaging were achieved repeatably using this approach. The use of large 3D volumes allowed comprehensive anatomical coverage at clinically useful spatial and/or temporal resolution. The need for careful, time-consuming, and subject-specific scan prescription was also eliminated. CONCLUSION: The highly parallel imaging approach presented here allows previously inaccessible volumetric coverage for time-sensitive MRI examinations such as contrast-enhanced MRA, and simultaneously provides a substantially simplified imaging paradigm. The resulting capability for rapid volumetric imaging promises to combine the strengths of MRI with some of the advantages of alternative imaging modalities such as multidetector CT.

Adult↗

Phase-constrained parallel MR image reconstruction.

A generalized method for phase-constrained parallel MR image reconstruction is presented that combines and extends the concepts of partial-Fourier reconstruction and parallel imaging. It provides a framework for reconstructing images employing either or both techniques and for comparing image quality achieved by varying k-space sampling schemes. The method can be used as a parallel image reconstruction with a partial-Fourier reconstruction built in. It can also be used with trajectories not readily handled by straightforward combinations of partial-Fourier and SENSE-like parallel reconstructions, including variable-density, and non-Cartesian trajectories. The phase constraint specifies a better-conditioned inverse problem compared to unconstrained parallel MR reconstruction alone. This phase-constrained parallel MRI reconstruction offers a one-step alternative to the standard combination of homodyne and SENSE reconstructions with the added benefit of flexibility of sampling trajectory. The theory of the phase-constrained approach is outlined, and its calibration requirements and limitations are discussed. Simulations, phantom experiments, and in vivo experiments are presented.

Algorithms↗

Lumped-element planar strip array (LPSA) for parallel MRI.

The recently introduced planar strip array (PSA) can significantly reduce scan times in parallel MRI by enabling the utilization of a large number of RF strip detectors that are inherently decoupled, and are tuned by adjusting the strip length to integer multiples of a quarter-wavelength (lambda/4) in the presence of a ground plane and dielectric substrate. In addition, the more explicit spatial information embedded in the phase of the signals from the strip array is advantageous (compared to loop arrays) for limiting aliasing artifacts in parallel MRI. However, losses in the detector as its natural resonance frequency approaches the Larmor frequency (where the wavelength is long at 1.5 T) may limit the signal-to-noise ratio (SNR) of the PSA. Moreover, the PSA's inherent lambda/4 structure severely limits our ability to adjust detector geometry to optimize the performance for a specific organ system, as is done with loop coils. In this study we replaced the dielectric substrate with discrete capacitors, which resulted in both SNR improvement and a tunable lumped-element PSA (LPSA) whose dimensions can be optimized within broad constraints, for a given region of interest (ROI) and MRI frequency. A detailed theoretical analysis of the LPSA is presented, including its equivalent circuit, electromagnetic fields, SNR, and g-factor maps for parallel MRI. Two different decoupling schemes for the LPSA are described. A four-element LPSA prototype was built to test the theory with quantitative measurements on images obtained with parallel and conventional acquisition schemes.

Equipment Design↗

Effects of inductive coupling on parallel MR image reconstructions.

Theoretical arguments and experimental results are presented that characterize the impact of inductive coupling on the performance of parallel MRI reconstructions. A simple model of MR signal and noise reception suggests that the intrinsic amount of spatial information available from a given coil array is unchanged in the presence of inductive coupling, as long as the sample remains the dominant source of noise for the coupled array. Any loss of distinctness in the measured coil sensitivities is compensated by information stored in the measured noise correlations. Adjustments to the theory are described to account for preamplifier noise contributions. Results are presented from an experimental system in which preamplifier input impedances are systematically adjusted in order to vary the level of coupling between array elements. Parallel image reconstructions using an array with four different levels of coupling and an acceleration factor up to six show average SNR changes of -7.6% to +7.5%. The modest changes in overall SNR are accompanied by similarly small changes in g-factor. These initial results suggest that moderate amounts of inductive coupling should not have a prohibitive effect on the use of a given coil array for parallel MRI.

Image Processing, Computer-Assisted↗

Highly parallel volumetric imaging with a 32-element RF coil array.

The improvement of MRI speed with parallel acquisition is ultimately an SNR-limited process. To offset acquisition- and reconstruction-related SNR losses, practical parallel imaging at high accelerations should include the use of a many-element array with a high intrinsic signal-to-noise ratio (SNR) and spatial-encoding capability, and an advantageous imaging paradigm. We present a 32-element receive-coil array and a volumetric paradigm that address the SNR challenge at high accelerations by maximally exploiting multidimensional acceleration in conjunction with noise averaging. Geometric details beyond an initial design concept for the array were determined with the guidance of simulations. Imaging with the support of 32-channel data acquisition systems produced in vivo results with up to 16-fold acceleration, including images from rapid abdominal and MRA studies.

Equipment Design↗

Shortening MR image acquisition time for volumetric interpolated breath-hold examination with a recently developed parallel imaging reconstruction technique: clinical feasibility.

A recently developed parallel magnetic resonance (MR) imaging technique, parallel imaging with an augmented radius in k space, was used to accelerate the volumetric interpolated breath-hold examination (VIBE) performed in 20 patients referred for clinical liver imaging. Nonaccelerated MR images were also acquired in these patients. A five-point scale was used to score the quality of the images. The acceleration resulted in reduced image quality: The nonaccelerated images had a significantly higher (P <.05) mean score--3.8 +/- 0.3 (SD), indicating good quality--than the accelerated images--3.0 +/- 0.3, indicating acceptable quality. However, for three patients who could not hold their breath for the duration necessary for nonaccelerated imaging, less severe breathing artifacts on the accelerated images resulted in improved quality compared with the quality of the nonaccelerated images. Parallel MR imaging-accelerated VIBE may be beneficial for patients who have difficulty sustaining a breath hold for the duration necessary to perform nonaccelerated imaging.

Adult↗

Ultimate intrinsic signal-to-noise ratio for parallel MRI: electromagnetic field considerations.

A method is described for establishing an upper bound on the spatial encoding capabilities of coil arrays in parallel MRI. Ultimate intrinsic signal-to-noise ratio (SNR), independent of any particular conductor arrangement, is calculated by expressing arbitrary coil sensitivities in terms of a complete set of basis functions that satisfy Maxwell's equations within the sample and performing parallel imaging reconstructions using these basis functions. The dependence of the ultimate intrinsic SNR on a variety of experimental conditions is explored and a physically intuitive explanation for the observed behavior is provided based on a comparison between the electromagnetic wavelength and the distance between aliasing points. Imaging at high field strength, with correspondingly short wavelength, is shown to offer advantages for parallel imaging beyond those already expected due to the larger available spin polarization. One-dimensional undersampling of k-space yields a steep drop in attainable SNR for more than a 5-fold reduction of scan time, while 2D undersampling permits access to much higher degrees of acceleration. Increased tissue conductivity decreases baseline SNR, but improves parallel imaging performance. A procedure is also provided for generating the optimal coil sensitivity pattern for a given acceleration, which will serve as a useful guide for future coil designs.

Algorithms↗

Rapid MR imaging by sensitivity profile indexing and deconvolution reconstruction (SPID).

A new parallel MR imaging technique, which uses localized information from the elements of a multi-coil array to accelerate imaging, is described. The technique offers an alternative reconstruction approach to currently available techniques (e.g., SMASH and SENSE). Following a partial k-space data acquisition, image reconstruction in this approach proceeds in two steps: first, fitting the measured coil sensitivities to a set of partially localized target functions, a blurred intermediate image of the studied object is produced. Blurring is obtained in a systematic manner, forming images of the studied object convolved with a known convolution kernel. Full spatial resolution is then recovered by deconvolution of the blurred images with the known kernel function. The technique offers flexibility in the arrangement of the acquired signal data k-lines, and a mechanism for controlling reconstruction quality through the convolution the deconvolution procedure. The technique was validated in phantom and in vivo imaging experiments demonstrating high time reduction factors.

Brain↗

Self-calibrating parallel imaging with automatic coil sensitivity extraction.

Calibration of the spatial sensitivity functions of coil arrays is a crucial element in parallel magnetic resonance imaging (PMRI). The most common approach has been to measure coil sensitivities directly using one or more low-resolution images acquired before or after accelerated data acquisition. However, since it is difficult to ensure that the patient and coil array will be in exactly the same positions during both calibration scans and accelerated imaging, this approach can introduce sensitivity miscalibration errors into PMRI reconstructions. This work shows that it is possible to extract sensitivity calibration images directly from a fully sampled central region of a variable-density k-space acquisition. These images have all the features of traditional PMRI sensitivity calibrations and therefore may be used for any PMRI reconstruction technique without modification. Because these calibration data are acquired simultaneously with the data to be reconstructed, errors due to sensitivity miscalibration are eliminated. In vivo implementations of self-calibrating parallel imaging using a flexible coil array are demonstrated in abdominal imaging and in real-time cardiac imaging studies.

Abdomen↗

Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI.

Parallel magnetic resonance imaging (MRI) techniques use spatial information from arrays of radiofrequency (RF) detector coils to accelerate imaging. A number of parallel MRI techniques have been described in recent years, and numerous clinical applications are currently being explored. The advent of practical parallel imaging presents various challenges for image reconstruction and RF system design. Recent advances in tailored SiMultaneous Acquisition of Spatial Harmonics (SMASH) image reconstructions are summarized. These advances enable robust SMASH imaging in arbitrary image planes with a wide range of coil array geometries. A generalized formalism is described which may be used to understand the relations between SMASH and SENSE, to derive typical implementations of each as special cases, and to form hybrid techniques combining some of the advantages of both. Accurate knowledge of coil sensitivities is crucial for parallel MRI, and errors in calibration represent one of the most common and the most pernicious sources of error in parallel image reconstructions. As one example, motion of the patient and/or the coil array between the sensitivity reference scan and the accelerated acquisition can lead to calibration errors and reconstruction artifacts. Self-calibrating parallel MRI approaches that address this problem by eliminating the need for external sensitivity references are reviewed. The ultimate achievable signal-to-noise ratio (SNR) for parallel MRI studies is closely tied to the geometry and sensitivity patterns of the coil arrays used for spatial encoding. Several parallel imaging array designs that depart from the traditional model of overlapped adjacent loop elements are described.

Calibration↗

State of the art in adrenal imaging.

The purposes of this article were to outline the current state of adrenal imaging, to highlight new developments, and to review the current radiologic advances that provide improved functional and structural information about adrenal disorders.

Adrenal Gland Neoplasms↗