PubMed Health⌕ Search

Biomedical subjects

Daniel Schmucki

Publications and source records attributed to Daniel Schmucki.

3 recordsLinked to original sources

Implementation, accuracy evaluation, and preliminary clinical trial of a CT-free navigation system for high tibial opening wedge osteotomy.

OBJECTIVE: The objectives of this study are to design and evaluate a CT-free intra-operative planning and navigation system for high tibial opening wedge osteotomy. This is a widely accepted treatment for medial compartment osteoarthritis and other lower extremity deformities, particularly in young and active patients for whom total knee replacement is not advised. However, it is a technically demanding procedure. Conventional preoperative planning and surgical techniques have so far been inaccurate, and often resulting in postoperative malalignment representing either under- or over-correction, which is the main reason for poor long-term results. In addition, conventional techniques have the potential to damage the lateral hinge cortex and tibial neurovascular structures, which may cause fixation failure, loss of correction, or peroneal nerve paralysis. All these common problems can be addressed by the use of a surgical navigation system. MATERIALS AND METHODS: Surgical instruments are tracked optically with the SurgiGATE((R)) navigation system (PRAXIM MediVision, La Tronche, France). Following exposure, dynamical reference bases are attached to the femur, tibia, and proximal fragment of the tibia. A patient-specific coordinate system is then established, on the basis of registered anatomical landmarks. After intra-operative deformity measurement and correction planning, the osteotomy is performed under navigational guidance. The deformities are corrected by realigning the mechanical axis of the affected limb from the diseased medial compartment to the healthy lateral side. The wedge size, joint line orientation, and tibial plateau slope are monitored during correction. Besides correcting uni-planar varus deformities, the system provides the functionality to correct complex multi-planar deformities with a single cut. Furthermore, with on-the-fly visualization of surgical instruments on multiple fluoroscopic images, penetration of the hinge cortex and damage to the neurovascular structures due to an inappropriate osteotomy can be avoided. RESULTS: The laboratory evaluation with a plastic bone model (Synbone AG, Davos, Switzerland) shows that the error of deformity correction is <1.7 degrees (95% confidence interval) in the frontal plane and <2.3 degrees (95% confidence interval) in the sagittal plane. The preliminary clinical trial confirms these results. CONCLUSION: A novel CT-free navigation system for high tibial osteotomy has been developed and evaluated, which holds the promise of improved accuracy, reliability, and safety of this procedure.

Arthroscopy↗

Computer aided reduction and imaging.

Reduction is one of the key procedures in orthopedic trauma surgery and has been acknowledged as one of the conditions for a good outcome in intraarticular and extra-articular fractures. The information available to the surgeon during the reduction maneuver can be divided into visual and tactile information. The optimal implementation of these parameters, combined with the surgeon's individual experience, will significantly affect the results of the operation. Anatomical regions where a limited direct view through the approach is supported by intraoperative imaging are intra-articular fractures of the elbow, forearm, acetabulum, proximal tibia, pilon, and hindfoot, and extra-articular fractures of the spine, pelvis, femur, and tibial shaft. Surgery in these regions is demanding since the approaches limit the visual control of the axes and also the anatomical reduction within the joint. Computer aided orthopedic surgery (CAOS) was introduced to increase the accuracy of selected procedures in orthopedic surgery. One of the most frequently applied applications is pedicle screw insertion in posterior spinal surgery. The current working group has identified computer aided reduction and implant positioning as an unresolved area of CAOS that would be highly relevant to the operative treatment of fractures. The development of tools for computer aided reduction is of major importance and is much desired by the orthopedic community. Such a reduction tool would be a significant step forward in the development of orthopedic trauma care. It would facilitate new procedures and new operations and also help to attain a completely new level with regard to what we can achieve in terms of minimal invasiveness and increased precision. The synergies of the expert group are deployed to develop the required software modules and hardware. Other areas of computer aided orthopedic surgery will certainly benefit from the integration of this technology as well.

Bone Screws↗

Retrieval of the ultraviolet aerosol optical depth during a spring campaign in the Bavarian Alps.

A measurement campaign was organized in March 1999 in the Bavarian Alps as part of the European project, Characteristics of the UV Radiation Field in the Alps (CUVRA), to analyze the effect of altitude, aerosols, and snow cover on ground-level UV spectral irradiance. We present the results of simultaneous measurements of aerosol optical depth (AOD) made at various sites on two cloudless days in March 1999. The two days exhibited different aerosol conditions. Results derived from spectral measurements of UV irradiance are compared with data from filter radiometer measurements made at discrete wavelengths extending from the UV to the near IR. The different methods generated values for the AOD that were in good agreement. This result confirms that one can use either method to retrieve the AOD with an uncertainty of approximately 0.03-0.05. On 18 March, high turbidity was observed at low altitude (400-nm AOD approximately 0.5 at 700 m above sea level), and the AOD decreased regularly with altitude; on 24 March, the turbidity was much less (0.11 at 700 m above sea level). On both days very low AODs (0.05-0.09) were measured at 3000 m above sea level. The spectral dependence of the AOD is often parameterized by the angstrom relationship; the alpha parameter is generally difficult or impossible to retrieve from spectral measurements because of the relatively narrow wavelength range (320-400 nm), and only one of the spectro-radiometers used during the campaign permits this retrieval. In most cases, during this field campaign, alpha was found by filter sunphotometers to be 1.1-1.5.

Journal Article↗