PubMed Health⌕ Search

Biomedical subjects

Daryl R Kipke

Publications and source records attributed to Daryl R Kipke.

At least 19 recordsLinked to original sources

Spatiotemporal pH dynamics following insertion of neural microelectrode arrays.

Insertion trauma is a critical issue when assessing intracortical electrophysiological and neurochemical recordings. Previous reports document a wide variety of insertion techniques with speeds ranging from 10 microm/s to 10 m/s. We hypothesize that insertion speed has an effect on tissue trauma induced by implantation of a neural probe. In order to monitor the neural interface during and after probe insertion, we have developed a silicon-substrate array with hydrous iridium oxide microelectrodes for potentiometric recording of extracellular pH (pH(e)), a measure of brain homeostasis. Microelectrode sites were sensitive to pH in the super-Nernstian range (-85.9 mV/pH unit) and selective over other analytes including ascorbic acid, Na(+), K(+), Ca(2+), and Mg(2+). Following insertion, arrays recorded either triphasic or biphasic pH(e) responses, with a greater degree of prolonged acidosis for insertions at 50 microm/s than at 0.5 mm/s or 1.0 mm/s (p<0.05). Spatiotemporal analysis of the recordings also revealed micro-scale variability in the pH(e) response along the array, even when using the same insertion technique. Implants with more intense acidosis were often associated histologically with blood along the probe tract. The potentiometric microsensor array has implications not only as a useful tool to measure extracellular pH, but also as a feedback tool for delivery of pharmacological agents to treat surgical brain trauma.

Acidosis↗

Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film.

Conductive polymer coatings can be used to modify traditional electrode recording sites with the intent of improving the long-term performance of cortical microelectrodes. Conductive polymers can drastically decrease recording site impedance, which in turn is hypothesized to reduce thermal noise and signal loss through shunt pathways. Moreover, conductive polymers can be seeded with agents aimed at promoting neural growth toward the recording sites or minimizing the inherent immune response. The end goal of these efforts is to generate an ideal long-term interface between the recording electrode and surrounding tissue. The goal of this study was to refine a method to electrochemically deposit surfactant-templated ordered poly(3,4-ethylenedioxythiophene) (PEDOT) films on the recording sites of standard 'Michigan' probes and to evaluate the efficacy of these modified sites in recording chronic neural activity. PEDOT-coated site performance was compared to control sites over a six-week evaluation period in terms of impedance spectroscopy, signal-to-noise ratio, number of viable unit potentials recorded and local field potential recordings. PEDOT sites were found to outperform control sites with respect to signal-to-noise ratio and number of viable unit potentials. The benefit of reduced initial impedance, however, was mitigated by the impedance contribution of typical silicon electrode encapsulation. Coating sites with PEDOT also reduced the amount of low-frequency drift evident in local field potential recordings. These findings indicate that electrode sites electrochemically deposited with PEDOT films are suitable for recording neural activity in vivo for extended periods. This study also provided a unique opportunity to monitor how neural recording characteristics develop over the six weeks following implantation.

Action Potentials↗

Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes.

Current neuroprosthetic systems based on electro-physiological recording have an extended, yet finite working lifetime. Some posited lifetime-extension solutions involve improving device biocompatibility or suppressing host immune responses. Our objective was to test an alternative solution comprised of applying a voltage pulse to a microelectrode site, herein termed "rejuvenation." Previously, investigators have reported preliminary electrophysiological results by utilizing a similar voltage pulse. In this study we sought to further explore this phenomenon via two methods: 1) electrophysiology; 2) an equivalent circuit model applied to impedance spectroscopy data. The experiments were conducted via chronically implanted silicon-substrate iridium microelectrode arrays in the rat cortex. Rejuvenation voltages resulted in increased unit recording signal-to-noise ratios (10% +/- 2%), with a maximal increase of 195% from 3.74 to 11.02. Rejuvenation also reduced the electrode site impedances at 1 kHz (67% +/- 2%). Neither the impedance nor recording properties of the electrodes changed on neighboring microelectrode sites that were not rejuvenated. In the equivalent circuit model, we found a transient increase in conductivity, the majority of which corresponded to a decrease in the tissue resistance component (44% +/- 7%). These findings suggest that rejuvenation may be an intervention strategy to prolong the functional lifetime of chronically implanted microelectrodes.

Action Potentials↗

Suitability of the cingulate cortex for neural control.

Recent neuroprosthetic work has focused on the motor cortex as a source of voluntary control signals. However, the motor cortex can be damaged in upper motor neuron degenerative diseases such as primary lateral sclerosis and amyotrophic lateral sclerosis. The possibility exists that prefrontal areas may also be used in neuroprosthetic devices. Here, we report the use of the cingulate cortex in a neuroprosthetic model. Seven rats were able to significantly modulate spiking activity in the cingulate cortex in order to receive reward. Furthermore, experiments with single neurons provide evidence that the cingulate cortex neuronal modulation is highly flexible and thus useful for a neuroprosthetic device.

Action Potentials↗

Multi-site incorporation of bioactive matrices into MEMS-based neural probes.

Methods are presented to incorporate polymer-based bioactive matrices into micro-fabricated implantable microelectrode arrays. Using simple techniques, hydrogels infused with bioactive molecules are deposited within wells in the substrate of the device. This method allows local drug delivery without increasing the footprint of the device. In addition, each well can be loaded individually, allowing spatial and temporal control over diffusion gradients in the microenvironment of the implanted neural interface probe. In vivo testing verified the following: diffusion of the bioactive molecules, integration of the bioactive molecules with the intended neural target and concurrent extracellular recording using nearby electrodes. These results support the feasibility of using polymer gels to deliver bioactive molecules to the region close to microelectrode shanks. This technique for microdrug delivery may serve as a means to intervene with the initial phases of the neuroinflammatory tissue response to permanently implanted microelectrode arrays.

Animals↗

A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex.

The viability of chronic neural microelectrodes for electrophysiological recording and stimulation depends on several factors, including the encapsulation of the implant by a reactive tissue response. We postulate that mechanical strains induced around the implant site may be one of the leading factors responsible for the sustained tissue response in chronic implants. The objectives of this study were to develop a finite-element model of the probe-brain tissue interface and analyze the effects of tethering forces, probe-tissue adhesion and stiffness of the probe substrate on the interfacial strains induced around the implant site. A 3D finite-element model of the probe-brain tissue microenvironment was developed and used to simulate interfacial strains created by 'micromotion' of chronically implanted microelectrodes. Three candidate substrates were considered: (a) silicon, (b) polyimide and (c) a hypothetical 'soft' material. Simulated tethering forces resulted in elevated strains both at the tip and at the sharp edges of the probe track in the tissue. The strain fields induced by a simulated silicon probe were similar to those induced by a simulated polyimide probe, albeit at higher absolute values for radial tethering forces. Simulations of poor probe-tissue adhesion resulted in elevated strains at the tip and delamination of the tissue from the probe. A tangential tethering force results in 94% reduction in the strain value at the tip of the polyimide probe track in the tissue, whereas the simulated 'soft' probe induced two orders of magnitude smaller values of strain compared to a simulated silicon probe. The model results indicate that softer substrates reduce the strain at the probe-tissue interface and thus may also reduce tissue response in chronic implants.

Animals↗

Microstimulation in auditory cortex provides a substrate for detailed behaviors.

Sensory cortical prostheses have potential to aid people suffering from blindness, deafness and other sensory deficits. However, research to date has shown that sensation thresholds via epicortical stimulation are surprisingly large. These thresholds result in potentially deleterious electrical currents, as well as large activation volumes. Large activation volumes putatively limit the corresponding number of independent stimulation channels in a neural prosthesis. In this study, penetrating stimulation of the auditory cortex was tested for its ability to transmit salient information to behaving rat subjects. Here, we show that subjects that were previously trained to discriminate natural stimuli immediately discriminated different microstimulation cues more accurately and with shorter response latencies than the natural stimuli. Additionally, the cortical microstimulation resulted in a generalization gradient across locations within the cortex. The results demonstrate the efficacy of using closely spaced cortical microstimulation to efficiently transmit highly salient and discriminable information to a behaving subject.

Acoustic Stimulation↗

Cortical microstimulation in auditory cortex of rat elicits best-frequency dependent behaviors.

Electrical activation of the auditory cortex has been shown to elicit an auditory sensation; however, the perceptual effects of auditory cortical microstimulation delivered through penetrating microelectrodes have not been clearly elucidated. This study examines the relationship between electrical microstimulus location within the adult rat auditory cortex and the subsequent behavior induced. Four rats were trained on an auditory frequency discrimination task and their lever-pressing behavior in response to stimuli of intermediate auditory frequencies was quantified. Each trained rat was then implanted with a microwire array in the auditory cortex of the left hemisphere. Best frequencies (BFs) of each electrode in the array were determined by both local field potential and multi-unit spike-rate activity evoked by pure tone stimuli. A cross-dimensional psychophysical generalization paradigm was used to evaluate cortical microstimulation-induced behavior. Using the BFs of each electrode, the microstimulation-induced behavior was evaluated relative to the auditory-induced behavior. Microstimulation resulted in behavior that was dependent on the BFs of the electrodes used for stimulation. These results are consistent with recent reports indicating that electrophysiological recordings of neural responses to sensory stimuli may provide insight into the sensation generated by electrical stimulation of the same sensory neural tissue.

Animals↗

Naive coadaptive cortical control.

The ability to control a prosthetic device directly from the neocortex has been demonstrated in rats, monkeys and humans. Here we investigate whether neural control can be accomplished in situations where (1) subjects have not received prior motor training to control the device (naive user) and (2) the neural encoding of movement parameters in the cortex is unknown to the prosthetic device (naive controller). By adopting a decoding strategy that identifies and focuses on units whose firing rate properties are best suited for control, we show that naive subjects mutually adapt to learn control of a neural prosthetic system. Six untrained Long-Evans rats, implanted with silicon micro-electrodes in the motor cortex, learned cortical control of an auditory device without prior motor characterization of the recorded neural ensemble. Single- and multi-unit activities were decoded using a Kalman filter to represent an audio "cursor" (90 ms tone pips ranging from 250 Hz to 16 kHz) which subjects controlled to match a given target frequency. After each trial, a novel adaptive algorithm trained the decoding filter based on correlations of the firing patterns with expected cursor movement. Each behavioral session consisted of 100 trials and began with randomized decoding weights. Within 7 +/- 1.4 (mean +/- SD) sessions, all subjects were able to significantly score above chance (P < 0.05, randomization method) in a fixed target paradigm. Training lasted 24 sessions in which both the behavioral performance and signal to noise ratio of the peri-event histograms increased significantly (P < 0.01, ANOVA). Two rats continued training on a more complex task using a bilateral, two-target control paradigm. Both subjects were able to significantly discriminate the target tones (P < 0.05, Z-test), while one subject demonstrated control above chance (P < 0.05, Z-test) after 12 sessions and continued improvement with many sessions achieving over 90% correct targets. Dynamic analysis of binary trial responses indicated that early learning for this subject occurred during session 6. This study demonstrates that subjects can learn to generate neural control signals that are well suited for use with external devices without prior experience or training.

Action Potentials↗

Enhanced contrast sensitivity in auditory cortex as cats learn to discriminate sound frequencies.

To better understand the nature and time course for learning-induced cortical reorganization, we examined frequency-specific changes in auditory cortex as cats gradually improved at a difficult sound frequency discrimination task. Three adult cats were trained to discriminate between a tone pip at a fixed target frequency (S-) and a higher deviant frequency (S+). An adaptive training schedule led to an efficient estimate of the frequency discrimination threshold (FDT), which was used to track daily performance. Each cat was also implanted with an array of microwires in auditory cortex. Tone pips with different frequency and amplitude were used to map receptive fields. Onset responses were correlated with training time and the cat's ability to discriminate frequencies. Although lifetime of the neural implants varied among cats, each provided sufficient neural recording to relate at least 3 weeks of learning to response changes in the cortex. An improved FDT was associated with a differential decrease in response strength between the S- frequency and S+ frequencies. Response to the training frequencies gradually located in a local minimum compared to adjacent frequencies (p < 0.001, Cohen's d=0.50). Cortical changes were consistent with a theory of bimodal generalization that enhances stimulus classification by reducing similarity between reinforced and nonreinforced stimuli. Such a strategy may be especially appropriate during an early stage of learning to discriminate similar sounds and differ from later strategies required for fine discrimination.

Animals↗

Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances.

Reactive tissue encapsulation of chronically implanted microelectrode probes can preclude long-term recording of extracellular action potentials. We investigated an intervention strategy for functionally encapsulated microelectrode sites. This method, known as "rejuvenation," involved applying a +1.5 V dc bias to an iridium site for 4 s. Previous studies have demonstrated that rejuvenation resulted in higher signal-to-noise ratios (SNRs) by decreasing noise levels, and reduced 1-kHz site impedances by decreasing the tissue interface resistances. In this study, we have investigated: 1) the duration of a single-voltage bias session and 2) the efficacy of multiple sessions. These questions were addressed through electrophysiological recordings, cyclic voltammetry, and modeling the electrode-tissue interface via an equivalent circuit model fit to impedance spectroscopy data. In the six implants studied, we found SNRs improved for 1-7 days with a peak typically occurring within 24 h of the voltage bias. Root-mean square (RMS) noise of the extracellular recordings decreased for 1-2 days, which paralleled a similar decrease in the adsorbed tissue resistance (Ren) from the model. Implants whose SNR effects lasted more than a day showed stabilized reductions in the extracellular tissue resistance (Rex) and cellular membrane area (Am). Subsequent stimulus sessions were found to drop neural tissue parameters consistently to levels observed immediately after surgery. In most cases, these changes did parallel an improvement in SNR. These findings suggest that rejuvenation may be a useful intervention strategy to prolong the lifetime of chronically implanted microelectrodes.

Action Potentials↗

Calcium alginate gel as a biocompatible material for endovascular arteriovenous malformation embolization: six-month results in an animal model.

OBJECTIVE: We sought to expand our assessment of calcium alginate as an embolic agent in an animal model of a cerebral arteriovenous malformation (AVM). The objective of this study was to assess the long-term biocompatibility and stability of calcium alginate in AVM swine models that survived from 1 to 6 months. METHODS: The swine model included a carotid-jugular anastomosis to redirect flow to the rete mirabile (RM), thereby simulating flow to an AVM. Alginate and the reactive component, calcium chloride, were injected from double-lumen or concentric-tube microcatheters to form an occlusion of the RM feeding vessel and the inferior portion of the RM. RESULTS: Angiography and histology verified complete occlusion of the RM feeding vessel for up to 6 months in eight of nine swine. Blood flow remained open to the superior portion of the RM and the circle of Willis. No evidence of downstream calcium alginate gel was seen in the follow-up angiograms or the histological preparations of the circle of Willis. A minor bioactive response to the alginate gel was noted at 1 month, yet no degenerative or inflammatory response was seen. At 6 months, there was moderate fibrous tissue around the alginate, which further sealed off flow to the embolized areas of the RM. CONCLUSION: Over a period of 6 months, calcium alginate was an effective endovascular occlusion material that blocked blood flow to the inferior portion of the RM. The chronic AVM model verified the long-term stability and biocompatibility of calcium alginate.

Alginates↗

Characterization of implantable microfabricated fluid delivery devices.

The formal characterization of the performance of microfluidic delivery devices is crucial for reliable in vivo application. A comprehensive laboratory technique was developed and used to optimize, calibrate and validate microfabricated fluid delivery devices. In vivo experiments were carried out to verify the accuracy and reliability of the pressure driven devices. Acute guinea pig experiments were conducted to measure the response to alpha-amino-3-hydroxy-5-methyl-4-isoxalone propionic acid, an excitatory neurotransmitter, at multiple locations in the inferior colliculus. A nondimensional parameter, Q, was successfully used to classify devices in terms of geometry alone (i.e., independent of fluid properties). Functional devices exhibited long-term linearity and reliability in delivering single phase, Newtonian fluids, in discrete volumes with a resolution of 500 picoliters at less than 0.45 lbf/in2 (30 mbar) pressure drop. Results for non-Newtonian fluids are not presented here. The acute results showed a proportional increase in the firing rate for delivered volumes of 2 nL up to 10 nL (at rates of between 0.1 and 1 nL/s). Flow characteristics are maintained during acute experiments and post-implant. A control experiment conducted with Ringer solution produced negligible effects, suggesting the results to be truly pharmacological. The experimental techniques employed have proven to be reliable and will be used for future calibration and testing of next generation chronic microfluidic delivery devices.

Action Potentials↗

Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex.

An important aspect of the development of cortical prostheses is the enhancement of suitable implantable microelectrode arrays for chronic neural recording. The objective of this study was to investigate the recording performance of silicon-substrate micromachined probes in terms of reliability and signal quality. These probes were found to consistently and reliably provide high-quality spike recordings over extended periods of time lasting up to 127 days. In a consecutive series of ten rodents involving 14 implanted probes, 13/14 (93%) of the devices remained functional throughout the assessment period. More than 90% of the probe sites consistently recorded spike activity with signal-to-noise ratios sufficient for amplitudes and waveform-based discrimination. Histological analysis of the tissue surrounding the probes generally indicated the development of a stable interface sufficient for sustained electrical contact. The results of this study demonstrate that these planar silicon probes are suitable for long-term recording in the cerebral cortex and provide an effective platform technology foundation for microscale intracortical neural interfaces for use in humans.

Action Potentials↗

Single electrode micro-stimulation of rat auditory cortex: an evaluation of behavioral performance.

A combination of electrophysiological mapping, behavioral analysis and cortical micro-stimulation was used to explore the interrelation between the auditory cortex and behavior in the adult rat. Auditory discriminations were evaluated in eight rats trained to discriminate the presence or absence of a 75 dB pure tone stimulus. A probe trial technique was used to obtain intensity generalization gradients that described response probabilities to mid-level tones between 0 and 75 dB. The same rats were then chronically implanted in the auditory cortex with a 16 or 32 channel tungsten microwire electrode array. Implanted animals were then trained to discriminate the presence of single electrode micro-stimulation of magnitude 90 microA (22.5 nC/phase). Intensity generalization gradients were created to obtain the response probabilities to mid-level current magnitudes ranging from 0 to 90 microA on 36 different electrodes in six of the eight rats. The 50% point (the current level resulting in 50% detections) varied from 16.7 to 69.2 microA, with an overall mean of 42.4 (+/-8.1) microA across all single electrodes. Cortical micro-stimulation induced sensory-evoked behavior with similar characteristics as normal auditory stimuli. The results highlight the importance of the auditory cortex in a discrimination task and suggest that micro-stimulation of the auditory cortex might be an effective means for a graded information transfer of auditory information directly to the brain as part of a cortical auditory prosthesis.

Animals↗

Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex.

This study investigated the use of planar, silicon-substrate microelectrodes for chronic unit recording in the cerebral cortex. The 16-channel microelectrodes consisted of four penetrating shanks with four recording sites on each shank. The chronic electrode assembly included an integrated silicon ribbon cable and percutaneous connector. In a consecutive series of six rats, 5/6 (83%) of the implanted microelectrodes recorded neuronal spike activity for more than six weeks, with four of the implants (66%) remaining functional for more than 28 weeks. In each animal, more than 80% of the electrode sites recorded spike activity over sequential recording sessions during the postoperative time period. These results provide a performance baseline to support further electrode system development for intracortical neural implant systems for medical applications.

Action Potentials↗

Flow properties of liquid calcium alginate polymer injected through medical microcatheters for endovascular embolization.

The flow properties of liquid calcium alginate injections were investigated for application in endovascular embolization. Alginate shear properties were assessed with a rheometer and a controlled injection system. The experimental results were used to model the flow properties and predict alginate's flow characteristics within various medical microcatheter delivery systems. The results suggest that alginates undergo shear-thinning effects with increasing shear. A flow comparison of 2.0 wt % alginate and a Newtonian fluid (82 cP) injected from the same microcatheter had similar flow rates at low injection pressure (100 kPa). However, at high injection pressure (2100 kPa), the alginate was injectable at a flow rate 100% higher than was the Newtonian fluid. Further analysis of injections through microcatheters resulted in a flow model for predicting viscosity changes, flow rates, and injection pressures of liquid alginate at medium-to-high shear rates. The predicted injection pressures and flow rates had an average variance of less than 15% from that of the experimental flow data. This study indicates that calcium alginate has the requisite flow properties for successful delivery to vascular lesions via endovascular injection. Possible uses of alginates include treating arteriovenous malformations (AVMs), aneurysms, blood flow to tumors, and vascular hemorrhages.

Alginates↗

Measuring the electrical stapedius reflex with stapedius muscle electromyogram recordings.

Previous studies have demonstrated a correlation between cochlear implant recipients' comfort levels (C level, upper limit of dynamic range of stimulation) and the contralateral electrical stapedius reflex (ESR) threshold, detected by acoustic impedance change. However, the utility of the approach is limited because many recipients have no detectable impedance change. The goals of this study were to investigate the utility of the stapedial electromyogram (EMG) for estimating onset and strength of the ESR. Ketamine-anesthetized guinea pigs were implanted with Nucleus electrode arrays and stimulated with biphasic current pulse trains (250 pps) via a Cochlear Corporation CI24M stimulator. Typical EMG recordings (obtained with bipolar microwire electrodes) contained easily detectable unit potentials up to 300 microV in amplitude. Growth response curves (obtained from threshold-crossing counts or rms of the EMG signal) were typically monotonic with dynamic ranges spanning 700 microA or 8 dB. Based on adaptation and temporal properties, the stimulus protocol (500 ms duration with 4-5 s interstimulus intervals) was adequate for producing independent responses. The data presented are consistent with ESR characteristics (acoustic impedance technique) of cochlear implant recipients and with EMG properties of acoustically stimulated guinea pigs. Use of the EMG for characterizing the ESR may eventually be applied to human cochlear implant recipients as a guide in setting the upper limit of the dynamic range.

Action Potentials↗