PubMed Health⌕ Search

Biomedical subjects

David R Walt

Publications and source records attributed to David R Walt.

At least 37 records · Page 2Linked to original sources

Detecting biological warfare agents.

We developed a fiber-optic, microsphere-based, high-density array composed of 18 species-specific probe microsensors to identify biological warfare agents. We simultaneously identified multiple biological warfare agents in environmental samples by looking at specific probe responses after hybridization and response patterns of the multiplexed array.

Bacteria↗

Simultaneously monitoring gene expression kinetics and genetic noise in single cells by optical well arrays.

An optical fiber based well array platform was used for simultaneous, dynamic gene expression monitoring from hundreds of individual live Escherichia coli cells carrying promoter-fluorescent reporter gene fusions. High information content about gene expression kinetics and cell-to-cell gene expression variability can be collected from a single experiment. These data are invaluable for investigating gene regulation and gene networks as well as for systems biology applications.

Escherichia coli↗

Fabrication of gold microtubes and microwires in high aspect ratio capillary arrays.

In this communication, we describe the sequential deposition of materials in capillaries as a means to produce self-assembled three-dimensional gold microtubes, hollow gold microwires, and microtube and microwire arrays with unprecedented aspect ratios. The initial application of this technique is the fabrication of an array of microwires within a silica capillary array. The physical characteristics of these microwires are characterized via SEM, electrochemistry, and electrogenerated chemiluminescence emission.

Gold Colloid↗

Optical fiber-based biosensors.

This review outlines optical fiber-based biosensor research from January 2001 through September 2003 and was written to complement the previous review in this journal by Marazuela and Moreno-Bondi. Optical fiber-based biosensors combine the use of a biological recognition element with an optical fiber or optical fiber bundle. They are classified by the nature of the biological recognition element used for sensing: enzyme, antibody/antigen (immunoassay), nucleic acid, whole cell, and biomimetic, and may be used for a variety of analytes ranging from metals and chemicals to physiological materials.

Biosensing Techniques↗

Living bacterial cell array for genotoxin monitoring.

A biosensor composed of a high-density living bacterial cell array was fabricated by inserting bacteria into a microwell array formed on one end of an imaging fiber bundle. The size of each microwell allows only one cell to occupy each well. In this biosensor, E. coli cells carrying a recA::gfp fusion were used as sensing components for genotoxin detection. Each fiber in the array has its own light pathway, enabling thousands of individual cell responses to be monitored simultaneously with both spatial and temporal resolution. The biosensor was capable of performing cell-based functional sensing of a genotoxin with high sensitivity and short incubation times (1 ng/mL mitomycin C after 90 min). Dose-response curves for several genotoxins were obtained. The biosensors demonstrated an active sensing lifetime of more than 6 h and a shelf lifetime of two weeks.

Bacteria↗

Reversible ratiometric probe for quantitative DNA measurements.

We have designed a reversible fluorescent DNA probe that can be used to determine the concentration of single-stranded DNA in solution by a ratiometric fluorescence measurement. The probe consists of a single-stranded dual fluorescently labeled DNA molecule that adopts a stem-loop conformation in its nonhybridized state. The stem length and the length of the loop region complementary to the target were chosen to allow for reversible binding. The excitation and emission wavelengths of the two labels Cy3 and Cy5 allow for fluorescence resonance energy transfer in the closed state. Upon hybridization, the probe opens up resulting in a fluorescence intensity increase of the donor and a fluorescence intensity decrease of the acceptor. The ratio of the acceptor-to-donor fluorescence intensities is independent of the amount of probe and provides a quantitative measure of the free target concentration.

Carbocyanines↗

Combinatorial decoding: an approach for universal DNA array fabrication.

A fiber optic microsphere-based oligonucleotide array is described that employs the sequence of the oligonucleotide probe attached to each microsphere as positional identifiers. Each microsphere serves as an immobilized array feature, functionalized with a unique single-stranded oligonucleotide sequence and randomly distributed into an array of microwells. To determine the sequences attached to individual microspheres, a series of fluorescently labeled combinatorial-pooled oligonucleotide target solutions was designed. Each combinatorial decoding solution is intended to identify the nucleotide at a particular position on every microsphere in the array. The combinatorial target solutions were synthesized by linking the four possible nucleotides at each position to four different fluorescent reporter dyes. As such, when the solutions were hybridized to the array, one of four possible fluorescent responses was generated for each position on a microsphere probe sequence. Adjusting the stringency of hybridization enabled single-base mismatch discrimination, and the signal with the highest intensity corresponded to the perfect nucleotide match. By consecutively exposing the array to a series of combinatorial decoding pool solutions, it was possible to simultaneously determine the sequence of every randomly positioned oligonucleotide-functionalized microsphere in the array. Once mapped, the microsphere array can be used for any typical genomic microarray experiment.

Base Sequence↗

Spatially resolved electrochemiluminescence on an array of electrode tips.

An array of electrode tips with 6-microm center-to-center spacing, fabricated through chemical etching of an optical fiber bundle, and coated with gold, was used for initiating electrochemiluminescence (ECL) in an aqueous solution of Ru(bpy)3(2+) and tri-n-propylamine (TPrA). ECL generated at the tips of the electrodes in the array was detected with a CCD camera and exhibited both high sensitivity and high resolution. In the case in which the ECL signal could not be distinguished from the background, ECL signals could be obtained by pulsing the array and summing multiple CCD images. The behavior of this array was compared to a second array that consisted of individual electrodes insulated with an electrophoretic paint.

Journal Article↗

Information coding in artificial olfaction multisensor arrays.

High-density sensor arrays were prepared with microbead vapor sensors to explore and compare the information coded in sensor response profiles following odor stimulus. The coded information in the sensor-odor response profiles, which is used for odor discrimination purposes, was extracted from the microsensor arrays via two different approaches. In the first approach, the responses from individual microsensors were separated (decoded array) and independently processed. In the second approach, response profiles from all microsensors within the entire array, i.e., the sensor ensemble, were combined to create one response per odor stimulus (nondecoded array). Although the amount of response data is markedly reduced in the second approach, the system shows comparable odor discrimination rates for the two signal extraction methods. The ensemble approach streamlines system resources without decreasing system performance. These signal compression approaches may simulate or parallel information coding in the mammalian olfactory system.

Animals↗

Enhancing vapor sensor discrimination by mimicking a canine nasal cavity flow environment.

This paper discusses the use of flow dynamics in a model nasal cavity as a novel way to expand the information available from a fiber optic vapor sensor. Nasal cavities are known to play an important role in vertebrate olfaction; however, they have not previously been incorporated into gas-phase sensor technology. By exposing identical sensors to different flow environments, we found that measurements of the combined sensor responses provided increased discrimination of a series of alcohols as compared to measurements obtained from a single sensor at the anterior of the cavity. This methodology is potentially useful for improving the discriminatory power of sensors employed in "artificial noses" and could be used to model the effects of flow dynamics in vertebrate olfaction.

1-Propanol↗

Optical imaging fiber-based live bacterial cell array biosensor.

A live cell array biosensor was fabricated by immobilizing bacterial cells on the face of an optical imaging fiber containing a high-density array of microwells. Each microwell accommodates a single bacterium that was genetically engineered to respond to a specific analyte. A genetically modified Escherichia coli strain, containing the lacZ reporter gene fused to the heavy metal-responsive gene promoter zntA, was used to fabricate a mercury biosensor. A plasmid carrying the gene coding for the enhanced cyan fluorescent protein (ECFP) was also introduced into this sensing strain to identify the cell locations in the array. Single cell lacZ expression was measured when the array was exposed to mercury and a response to 100nM Hg(2+) could be detected after a 1-h incubation time. The optical imaging fiber-based single bacterial cell array is a flexible and sensitive biosensor platform that can be used to monitor the expression of different reporter genes and accommodate a variety of sensing strains.

Adenosine Triphosphatases↗

The use of optical fiber bundles combined with electrochemistry for chemical imaging.

The present Review describes the progress made in using imaging optical fiber bundles for fluorescence and electrochemical-initiated chemiluminescence imaging. A novel optoelectrochemical micro-ring array has been fabricated and demonstrated for concurrent electrochemical and optical measurements. The device comprises optical fibers coated with gold via electroless gold deposition and assembled in a random array format. The design yielded an array of approximately 200 micro-ring electrodes, where interdiffusional problems were minimized. The inner diameter of the ring electrode is fixed by the diameter of the individual optical fibers (25 microns), while the outer radius is determined by the thickness of the deposited gold. While all the fibers are optically addressable, they are not all electrochemically addressable. The resolution of this device is in the tens of micrometers range, determined by the diameter of the optical fiber (25 microns) and by the spacing between each electrically connected fiber. For the purpose of having well-behaved microelectrode characteristics, this spacing was designed to be larger than 60 microns. The array was characterized using ferrocyanide in aqueous solution as a model electroactive species to demonstrate that this microelectrode array format exhibits steady-state currents at short response times. This device has potential application to be used as an optoelectronic sensor, especially for the electrolytic generation and transmission of electrochemiluminescence, and was used to demonstrate that electrochemically generated luminescent products can be detected with the fiber assembly.

Diagnostic Imaging↗

High-density, microsphere-based fiber optic DNA microarrays.

A high-density fiber optic DNA microarray has been developed consisting of oligonucleotide-functionalized, 3.1-microm-diameter microspheres randomly distributed on the etched face of an imaging fiber bundle. The fiber bundles are comprised of 6000-50000 fused optical fibers and each fiber terminates with an etched well. The microwell array is capable of housing complementary-sized microspheres, each containing thousands of copies of a unique oligonucleotide probe sequence. The array fabrication process results in random microsphere placement. Determining the position of microspheres in the random array requires an optical encoding scheme. This array platform provides many advantages over other array formats. The microsphere-stock suspension concentration added to the etched fiber can be controlled to provide inherent sensor redundancy. Examining identical microspheres has a beneficial effect on the signal-to-noise ratio. As other sequences of interest are discovered, new microsphere sensing elements can be added to existing microsphere pools and new arrays can be fabricated incorporating the new sequences without altering the existing detection capabilities. These microarrays contain the smallest feature sizes (3 microm) of any DNA array, allowing interrogation of extremely small sample volumes. Reducing the feature size results in higher local target molecule concentrations, creating rapid and highly sensitive assays. The microsphere array platform is also flexible in its applications; research has included DNA-protein interaction profiles, microbial strain differentiation, and non-labeled target interrogation with molecular beacons. Fiber optic microsphere-based DNA microarrays have a simple fabrication protocol enabling their expansion into other applications, such as single cell-based assays.

Equipment Design↗

Fluorescence-based fibre optic arrays: a universal platform for sensing.

Optical fibres provide a universal sensing platform as they are easily integrated with a multitude of different sensing schemes. Such schemes enable the preparation of a multitude of sensors from relatively straightforward pH sensors, to more complex ones, including artificial olfaction sensors, high-density oligonucleotide arrays, and high-throughput cell-based arrays. Imaging fibre bundles comprised of thousands of fused optical fibres are the basis for an optically connected, individually addressable parallel sensing platform. Fibre optic imaging bundles possess miniature feature sizes (3-10 micron diameter fibres), allowing high-density sensor packing (approximately 2 x 10(7) sensors per cm2). Imaging fibre bundles transmit coherent images enabling combined imaging and sensing, relating the responses monitored by the sensor to observable physical changes. The individual fibre cores can also be selectively etched to form a high-density microwell array capable of housing complementary sized microsensors. The miniature feature sizes facilitate a faster response and more sensitive measurement capabilities. The platform is extremely versatile in its sensing design, allowing the sensing scheme to be tailored to fit the experimental design, whether for monitoring single analytes or more complex multiplexed assays. A number of sensing schemes and applications are described in this review.

Biosensing Techniques↗

Automatic decoding of sensor types within randomly ordered, high-density optical sensor arrays.

In this paper automatic sensor identification of sensor classes within a high-density randomized array, without a priori knowledge of sensor locations, is demonstrated. Two different fluorescence-based sensor types, with hundreds of replicates each, were randomly distributed into an optical imaging fiber array platform. The sensor element types were vapor-sensitive microspheres with the environmentally-sensitive fluorescent dye Nile Red adsorbed on their surface. Nile Red undergoes spectral changes when exposed to different microenvironmental polarity conditions, e.g. microsphere surface polarity or odor exposure. These reproducible sensor spectral changes, or sensor-response profiles, enable sensors within a randomized array to be grouped into categories by optical decoding methods. Two computational decoding methods (supervised and unsupervised) are introduced; equal classification rates were achieved for both. By comparing sensor responses from a randomized array with those obtained from known (control) arrays, 587 sensors were correctly classified with 99.32% accuracy. Although both methods were equally effective, the unsupervised method, which uses sensor response changes to odor exposure, is a better decoding model for the vapor-sensitive arrays studied, because it relies only on the odor-response profiles. Another decoding technique employed the emission spectra of the sensors and is more applicable to other types of multiplexed fluorescence-based arrays and assays. The sensor-decoding techniques are compared to demonstrate that sensors within high-density optical chemosensor arrays can be positionally-registered, or decoded, with no additional overhead in time or expense other than collecting the sensor-response profiles.

Journal Article↗

Optical imaging fiber-based single live cell arrays: a high-density cell assay platform.

A high-density, ordered array containing thousands of microwells is fabricated on an optical imaging fiber. Each individually addressable microwell is used to accommodate a single living cell. A charged coupled device (CCD) detector is employed to monitor and spatially resolve the fluorescence signals obtained from each individual cell, allowing simultaneous monitoring of cellular responses of all the cells in the array using reporter genes (lacZ, EGFP, ECFP, DsRed) or fluorescent indicators. Yeast and bacteria cell arrays were fabricated and used to perform multiplexed cell assays with resolution at the single-cell level. Monitoring gene expression in single yeast cells carrying a two-hybrid system was used to detect in vivo protein-protein interactions. The single-cell array technology provides a new platform for monitoring the unique multiple responses of large populations of individual cells from different strains or cell lines. The rich data acquired by the cell array has the potential to be employed as a new tool for cell biology research as well as to improve cell-based high-throughput screening (HTS) applications, such as the validation of new disease-associated cellular targets and the early-stage evaluation of potential drug candidates.

Escherichia coli↗

High-density fiber-optic genosensor microsphere array capable of zeptomole detection limits.

The detection limit of a fiber-optic microsensor array was investigated for simultaneous detection of multiple DNA sequences. A random array composed of oligonucleotide-functionalized 3.1-microm-diameter microspheres on the distal face of a 500-microm etched imaging fiber was monitored for binding to fluorescently labeled complementary DNA sequences. Inherent sensor redundancy in the microarray allows the use of multiple microspheres to increase the signal-to-noise ratio, further enhancing the detection capabilities. Specific hybridization was observed for each of three sequences in an array yielding a detection limit of 10(-21) mol (approximately 600 DNA molecules).

Animals↗