PubMed Health⌕ Search

Biomedical subjects

David R Walt

Publications and source records attributed to David R Walt.

40 records · Page 3Linked to original sources

Fabrication of an optoelectrochemical microring array.

In this paper, we describe a novel approach for fabricating an optoelectrochemical microring array. The array was fabricated by coating individual optical fibers of 25-microm diameter with a 1-microm layer of gold nanoparticles via electroless gold deposition. A SAM layer around the individual gold-coated imaging fibers prevented electrical contact with neighboring ring electrodes. To achieve better mechanical stability and to make the device more practical, the electrode/fiber bundle comprising approximately 600 individual gold-coated optical fibers was dipped into epoxy. By polishing the ends of such a device, a ring microelectrode array comprising 600 individual and insulated ring electrodes was formed. To limit diffusional overlap of current, only 20-30% of the microring fiber/electrodes were wired. The inner diameter of the ring electrode is fixed by the diameter of the individual optical fibers (25 microm), while the outer radius is determined by the thickness of the deposited gold. The array was characterized using ferrocyanide in aqueous solution as a model electroactive species to demonstrate that this microelectrode array format exhibits steady-state currents at short response times. In addition, cyclic voltammetry experiments were performed using conventional potentiostats due to the amplification of current inherent in the array format. Finally, electrochemiluminescence at the ring electrode array was demonstrated through the oxidation of Ru(bpy)3(2+) in tri-n-propylamide in a pH 7 phosphate buffer solution, where the light generated was collected and detected via the fiber bundle.

Electrochemistry↗

Aluminum surface corrosion and the mechanism of inhibitors using pH and metal ion selective imaging fiber bundles.

The localized corrosion behavior of a galvanic aluminum copper couple was investigated by in situ fluorescence imaging with a fiber-optic imaging sensor. Three different, but complementary methods were used for visualizing remote corrosion sites, mapping the topography of the metal surface, and measuring local chemical concentrations of H+, OH-, and Al3+. The first method is based on a pH-sensitive imaging fiber, where the fluorescent dye SNAFL was covalently attached to the fiber's distal end. Fluorescence images were acquired as a function of time at different areas of the galvanic couple. In a second method, the fluorescent dye morin was immobilized on the fiber-optic imaging sensor, which allowed the in situ localization of corrosion processes on pure aluminum to be visualized over time by monitoring the release of Al3+. The development of fluorescence on the aluminum surface defined the areas associated with the anodic dissolution of aluminum. We also investigated the inhibition of corrosion of pure aluminum by CeCl3 and 8-hydroxyquinoline. The decrease in current, the decrease in the number of active sites on the aluminum surface, and the faster surface passivation are all consistent indications that cerium chloride and 8-hydroxyquinoline inhibit corrosion effectively. From the number and extent of corrosion sites and the release of aluminum ions monitored with the fiber, it was shown that 8-hydroxyquinoline is a more effective inhibitor than cerium chloride.

Aluminum↗

Imaging optical sensor arrays.

Imaging optical fibres have been etched to prepare microwell arrays. These microwells have been loaded with sensing materials such as bead-based sensors and living cells to create high-density sensor arrays. The extremely small sizes and volumes of the wells enable high sensitivity and high information content sensing capabilities.

Fiber Optic Technology↗