PubMed Health⌕ Search

Biomedical subjects

David Smith

Publications and source records attributed to David Smith.

133 records · Page 8Linked to original sources

Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis.

Selected ion flow tube mass spectrometry (SIFT-MS) is a new analytical technique for the real-time quantification of several trace gases simultaneously in air and breath. It relies on chemical ionization of the trace gas molecules in air/breath samples introduced into helium carrier gas using H(3)O(+), NO(+), and O(2) (+.) precursor ions. Reactions between the precursor ions and trace gas molecules proceed for an accurately defined time, the precursor and product ions being detected and counted by a downstream mass spectrometer, thus effecting quantification. Absolute concentrations of trace gases in single breath exhalation can be determined by SIFT-MS down to ppb levels, obviating sample collection and calibration. Illustrative examples of SIFT-MS studies include (i) analysis of gases from combustion engines, animals and their waste, and food; (ii) breath and urinary headspace studies of metabolites, ethanol metabolism, elevated acetone during ovulation, and exogenous compounds; and (iii) urinary infection and the presence of tumors, the influence of dialysis on breath ammonia, acetone, and isoprene, and acetaldehyde released by cancer cells in vitro. Flowing afterglow mass spectrometry (FA-MS) is briefly described, which allows on-line quantification of deuterium in breath water vapor.

Air↗

Effect of blood temperature on the efficacy of systemic leucodepletion during cardiopulmonary bypass: a prospective randomized clinical study.

The authors examined the effect of blood temperature within the cardiopulmonary bypass (CPB) circuit on the efficacy of an arterial line filter. Eighty patients undergoing elective, primary coronary artery bypass grafting under CPB were prospectively randomized in two equal groups. Blood temperature was kept at 35 degrees C in the first group and reduced to 28 degrees C in the second group. Twenty patients in each group had an arterial line LG6 filter attached onto CPB circuit. The other 20 patients in each group (controls) had a non-leukocyte-depleting filter. Blood samples (10 ml) were taken before CPB, at 5 minutes on CPB, at 30 minutes on CPB, 5 minutes after aortic clamp removal, and 6 hours postoperatively. Leucocytes were counted under light microscopy. Activated leucocytes were identified using nitroblue tetrazolium staining. Patients undergoing leucodepletion had significantly lower total and activated leukocyte counts than control patients in both groups (p < 0.05). Patients having a leukocyte-depleting filter at a CPB temperature of 35 degrees C had significantly lower total leukocyte counts (p < 0.05) than those having a leukocyte-depleting filter at a CPB temperature of 28 degrees C (p < 0.05). However, there were not statistically significant differences in the activated leukocyte counts between the two leucodepleted groups (p > 0.05). This study shows that warm blood temperature within the CPB circuit has a positive effect on the overall leucodepleting efficacy of the LG6 filter. Activated leucocytes, however, seem to be depleted at similar rates irrespective of the blood temperature in the CPB circuit.

Aged↗

Leukocytes-depleting filters preferentially remove activated leukocytes and reduce the expression of surface adhesion molecules during the simulated extracorporeal circulation of human blood.

The effect of leukocyte-depleting filters on the total and activated leukocyte counts and the expression of surface adhesion molecules CD11b, CD18, and CD62L during the in vitro extracorporeal circulation of human blood was studied. A 200 ml blood sample was taken from 10 patients undergoing CABG surgery. The blood was circulated for 60 minutes within an experimental extracorporeal circuit. A leukocyte-depleting filter was attached in five circuits (filtered group). In five other circuits, no filter was used (controls). Total leukocyte counts were determined manually. Activated leukocytes were identified using nitroblue tetrazolium staining. The expression of CD11b, CD18, and CD62L was measured with flow cytometry. At 60 minutes, total leukocyte counts were reduced by 49% from the baseline values in the filtered group and 10% in the control group (p < 0.0001). Activated leukocyte counts decreased by 86% in the filtered group and increased by 116% in the control group (p < 0.0001). In the filtered group, the expression of CD11b, CD18, and CD612L decreased by 60%, 21%, and 79%, respectively, and in the control group it increased by 24%, 6%, and 28% (p < 0.0001). Leukocyte-depleting filters preferentially remove activated leukocytes and reduce the expression of CD11b, CD18, and CD62L during the in vitro extracorporeal circulation of human blood.

Aged↗

Deploying the EMR, Part 1: The basic needs.

This case study presents a collection of principles and guidelines regarding the process of selecting and deploying an electronic medical record (EMR) in a physician's practice. Practical advice and observations are detailed about what was learned and how the practice has benefited. In Part 1 of this article, the authors identify the functions that are crucial in an ideal EMR. In Part 2, they will provide their guidelines for implementing these functions.

Efficiency, Organizational↗

Deploying the EMR: Part 2, Implementation.

This case study presents a collection of principles and guidelines regarding the process of selecting and deploying an electronic medical record (EMR) in a physician's practice. Practical advice and observations are detailed about what was learned and how the practice has benefited. In Part 1 of this article (Volume 18, pages 256-261), the authors identified the functions that are crucial in an ideal EMR. Part 2 provides their guidelines for implementing the system with particular emphasis on selection of the vendor.