Uncertainties when using only one MRI-based treatment plan for subsequent high-dose-rate tandem and ring applications in brachytherapy of cervix cancer.

BACKGROUND AND PURPOSE: This retrospective study compares individual MRI based 3D treatment planning for each intracavitary applicator insertion and the use of only one MRI treatment plan for cervical cancer brachytherapy. MATERIALS AND METHODS: GTV, high risk (HR) CTV and OAR were delineated and analysed for 14 patients. Data using the individual approach were taken from the actual irradiated plans. The "single plan procedure" was simulated by matching the dose distribution of the first plan to the MRI datasets of each subsequent implantation. Total doses from brachytherapy were added up and normalized to 2Gy fractionation (EQD2). RESULTS: The mean D90 for HR CTV was 6Gy higher when using one plan than when using individual treatment plans. The D(2cc) increased 3.5Gy for the bladder, 4.2Gy for the rectum and 5.8Gy for the sigmoid. The use of only one treatment plan would have resulted in 2, 1 and 5 extra cases exceeding total D(2cc) constraints for bladder (90Gy), rectum (75Gy) and sigmoid (75Gy), respectively. CONCLUSION: The use of only one treatment plan for several applications results in higher dose to target and OAR structures. CT, clinical examination and X-ray findings can help to reduce certain situations of overdosage, when individual MRI based treatment planning is not available for each fraction.

Brachytherapy↗

Pencil kernel correction and residual error estimation for quality-index-based dose calculations.

Experimental data from 593 photon beams were used to quantify the errors in dose calculations using a previously published pencil kernel model. A correction of the kernel was derived in order to remove the observed systematic errors. The remaining residual error for individual beams was modelled through uncertainty associated with the kernel model. The methods were tested against an independent set of measurements. No significant systematic error was observed in the calculations using the derived correction of the kernel and the remaining random errors were found to be adequately predicted by the proposed method.

Biophysical Phenomena↗

Dosimetric comparison of stereotactic body radiotherapy in different respiration conditions: a modeling study.

PURPOSE: To evaluate the dosimetric consequences for irradiated lung tissue for different respiration conditions for hypofractionated stereotactic body radiotherapy (SBRT). METHODS AND MATERIALS: Thirteen patients with lung lesion undergoing SBRT treatment in shallow breathing with abdominal compression (SB+AP) underwent additional multislice CT studies in free breathing (FB), deep inspiration and expiration breath hold (DIBH, DEBH). For each patient 6 different treatment plans were designed for the various respiration conditions applying standard (7/7/10 mm), reduced (5/5/5 mm) and individual margins. The FB plan with standard margins was used as a reference. The percentage of volume of the ipsilateral lung receiving total doses > or=12, 15> or= and > or=18 Gy, mean lung dose (D(mean)), NTCP corrected for fractionation effects and the total monitor units (MU) were evaluated. RESULTS: With DIBH it was possible to reduce all lung dose parameters by about 20%. Applying reduced margins in DIBH, this reduction was even increased to about 40%. The standard technique (SB+AP) with individual margins showed similar results as DIBH with standard margins. DEBH showed some improvement over FB only when reduced margins were applied. Only for 5/13 patients NTCP values >1% were obtained. For these patients a significant NTCP reduction was achieved with DIBH techniques. CONCLUSIONS: In SBRT shallow breathing with abdominal compression produces acceptable results concerning lung DVHs. DIBH, especially with reduced margins, showed the best lung sparing. For the clinical implementation of such a technique some form of gating is advisable. However, there are some practical limitations due to high fractional doses.

Adult↗

An intercomparison of 11 amorphous silicon EPIDs of the same type: implications for portal dosimetry.

The use of electronic portal imaging devices (EPIDs) for portal dosimetry requires knowledge of their dosimetric properties. The pixel value response of amorphous silicon EPIDs of type Elekta iViewGT is known to be nonlinear with dose. However, it is not clear whether these nonlinearities vary with time and from one detector to another, respectively. In the present study, the dose-response characteristics of 11 iViewGT EPIDs were investigated with respect to dose rate, total dose and field size. It was found that each detector needs to be individually calibrated, not only in terms of absolute sensitivity but also with respect to its relative response variations with exposure parameters. Doubling the dose rate typically increased the EPID signal between 1.4% and 2.8%. Changing the number of monitor units from 30 to 500 was accompanied by an increase in detector sensitivity between 1.7% and 2.8%. The EPID scatter factors were always within +/-1%. It was observed that the dose-response behaviour was not stable with respect to time. Particularly within the first weeks of operation, detector ageing caused variations in both absolute sensitivity and relative response curves. It is recommended to establish a quality assurance programme if the amorphous silicon EPIDs are intended to be used for clinical portal dosimetry.

Dose-Response Relationship, Radiation↗

Factors influencing bowel sparing in intensity modulated whole pelvic radiotherapy for gynaecological malignancies.

BACKGROUND AND PURPOSE: To evaluate the influence of uterus and bladder size on large and small bowel sparing with intensity modulated whole pelvic radiotherapy (IM-WPRT) in gynecologic patients. PATIENTS AND METHODS: Twenty patients were selected; 10 women with cervical cancer treated with definitive radiotherapy (group 'DEF') and 10 endometrial cancer patients treated postoperatively (group 'POST'). Bladder, rectal wall, small (SB) and large bowel (LB) were delineated as organs at risk. A conformal four field technique and a seven field IMRT plan (prescription dose 50.4 Gy) were compared in terms of DVH and various target parameters. RESULTS: At doses between 40 and 50.4 Gy statistically significant improvements (P<0.05) were observed for IM-WPRT for irradiated volume of rectal wall and bladder. In both patient groups, with IMRT the average irradiated volume of SB was reduced by a factor of 6 at 50.4Gy. This ratio was 2 for LB. In the DEF group the effect of SB-sparing with IMRT correlated with bladder size (correlation coefficient 0.70) while it did not correlate in the postoperative group. The effect of LB-sparing decreased with increasing bladder size in both groups but the impact of IMRT was larger for postoperative patients. CONCLUSIONS: IMRT significantly reduced the absolute volume of rectal wall, bladder and bowel irradiated at the prescribed dose level in gynaecologic patients. Main differences between POST and DEF patients receiving IM-WPRT were absolute volumes of LB irradiated to doses between 35 and 50Gy, suggesting an impact of intact uterus on LB volume in the pelvis. POST patients seem to benefit most from elective nodal IMRT. Bladder filling is an important co-factor influencing the benefit of IMRT with respect to OAR sparing.

Cohort Studies↗

The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: design, application, treatment planning, and dosimetric results.

PURPOSE: To present a combined intracavitary and interstitial dedicated applicator and magnetic resonance imaging (MRI) treatment planning for cervical cancer brachytherapy. METHODS AND MATERIALS: A modified ring applicator allows interstitial needles to be implanted in parallel to the intrauterine tandem. MRI treatment planning based on a standard loading pattern with stepwise dwell weight adaptation and needle loading is performed to achieve optimal dose coverage and sparing of organs at risk. Dose constraints are applied for dose-volume histogram parameters. RESULTS: The use of additional interstitial needles provides prescription dose up to 15 mm lateral to point A. Twenty-two patients with high-risk clinical target volumes of mean 44 cm3 were treated with a mean prescribed total dose of 85 Gy (biologically equivalent to 2 Gy fractionation, alpha/beta = 10 Gy) and 93% coverage (V100). The dose to organs at risk was within standard limits for intracavitary brachytherapy alone. CONCLUSIONS: A combined interstitial-intracavitary applicator results in reproducible implants for cervical cancer brachytherapy. MRI-based treatment planning based on a target concept, dose-volume constraints, and limitations for the relative dwell weight allows for an increase in target coverage, treated volume, and total dose without increasing the dose to critical structures.

Brachytherapy↗

Intercomparison of treatment concepts for MR image assisted brachytherapy of cervical carcinoma based on GYN GEC-ESTRO recommendations.

PURPOSE: To perform a multicentre intercomparison study of treatment concepts for MRI assisted brachytherapy of cervix cancer based on recommendations of the Gynaecological GEC-ESTRO Working Group. METHODS: Each participating centre (IGR Paris, University Hospital Leuven, Medical University of Vienna) contributed data of one patient with comparable clinical features. GTV, High Risk CTV (HR CTV), Intermediate Risk CTV (IR CTV) and organ walls of bladder, rectum and sigmoid colon were delineated at the time of each brachytherapy fraction on axial MR images with the applicator in place. Dose-volume histograms were calculated to evaluate doses to tumour, target volumes and organs at risk. Dose values were biologically normalised to equivalent doses in 2 Gy fractions (EQD(2), equivalent to 50 cGy/h low dose rate) applying the linear-quadratic model. RESULTS: Total doses to point A from external beam therapy plus brachytherapy ranged from 85 to 91 Gy and were close to the dose covering 90% of HR CTV (D90=85-87 Gy). D90 of IR CTV was within 69-73 Gy. Doses to organs at risk were comparable. CONCLUSIONS: This study indicates the feasibility of the GEC-ESTRO recommendations. Despite different treatment concepts, biologically normalised total doses to tumour, target volumes and organs at risk were comparable.

Brachytherapy↗

Inverse planning--a comparative intersystem and interpatient constraint study.

PURPOSE: To compare commercial treatment-planning systems (TPS) for inverse planning (IP) and to assess constraint variations for specific IMRT indications. MATERIAL AND METHODS: For IP, OTP, XiO and BrainSCAN were used and step-and-shoot intensity-modulated radiotherapy (IMRT) delivery was assumed. Based on identical constraints, IP was performed for a prostate, head and neck, brain, and gynecologic case. IMRT plans were compared in terms of conformity/homogeneity, dose-volume histograms (DVHs), and delivery efficiency. For ten patients each of a class of indications, constraint variations were evaluated. RESULTS: IMRT plans were comparable concerning minimum target dose, homogeneity, conformity, and maximum doses to organs at risk. Larger differences were seen in dose gradients outside the target, monitor units, and segment number. Using help structures proved efficient to shape isodoses and to reduce segmentation workload. For IMRT class solutions, IP constraint variations depended on anatomic site. CONCLUSION: IP systems requiring doses as input and having objective functions based on physical parameters had a very similar performance. Constraint templates can be established for a class of IMRT indications.

Brain Neoplasms↗

Evaluation of uncertainty predictions and dose output for model-based dose calculations for megavoltage photon beams.

In many radiotherapy clinics an independent verification of the number of monitor units (MU) used to deliver the prescribed dose to the target volume is performed prior to the treatment start. Traditionally this has been done by using methods mainly based on empirical factors which, at least to some extent, try to separate the influence from input parameters such as field size, depth, distance, etc. The growing complexity of modern treatment techniques does however make this approach increasingly difficult, both in terms of practical application and in terms of the reliability of the results. In the present work the performance of a model-based approach, describing the influence from different input parameters through actual modeling of the physical effects, has been investigated in detail. The investigated model is based on two components related to megavoltage photon beams; one describing the exiting energy fluence per delivered MU, and a second component describing the dose deposition through a pencil kernel algorithm solely based on a measured beam quality index. Together with the output calculations, the basis of a method aiming to predict the inherent calculation uncertainties in individual treatment setups has been developed. This has all emerged from the intention of creating a clinical dose/MU verification tool that requires an absolute minimum of commissioned input data. This evaluation was focused on irregular field shapes and performed through comparison with output factors measured at 5, 10, and 20 cm depth in ten multileaf collimated fields on four different linear accelerators with varying multileaf collimator designs. The measurements were performed both in air and in water and the results of the two components of the model were evaluated separately and combined. When compared with the corresponding measurements the resulting deviations in the calculated output factors were in most cases smaller than 1% and in all cases smaller than 1.7%. The distribution describing the calculation errors in the total dose output has a mean value of -0.04% and a standard deviation of 0.47%. In the dose calculations a previously developed correction of the pencil kernel was applied that managed to contract the error distribution considerably. A detailed analysis of the predicted uncertainties versus the observed deviations suggests that the predictions indeed can be used as a basis for creating action levels and tracking dose calculation errors in homogeneous media.

Air↗

Basic investigations on the performance of a normoxic polymer gel with tetrakis-hydroxy-methyl-phosphonium chloride as an oxygen scavenger: reproducibility, accuracy, stability, and dose rate dependence.

Magnetic resonance (MR)-based polymer gel dosimetry using normoxic polymer gels, represents a new dosimetric method specially suited for high-resolution three-dimensional dosimetric problems. The aim of this study was to investigate the dose response with regard to stability, accuracy, reproducibility, and the dose rate dependence. Tetrakis-hydroxy-methyl-phosphonium chloride (THPC) is used as an oxygen scavenger, and methacrylic acid as a monomer. Accuracy, reproducibility, and dose resolution were determined for MR protocols at low spatial resolution (typical for clinical scanners), medium, and microimaging-resolution protocols at three different dose levels. The dose-response stability and preirradiation-induced variations in R2, related to the time interval between preparation and irradiation of the polymer gel, were investigated. Also postirradiation stability of the polymer gel was considered. These experiments were performed using a 60Co beam (E = 1.2 MV) in a water phantom. Moreover, we investigated the dose rate dependence in the low, medium, and saturation dose region of the normoxic polymer gel using a linear accelerator at photon energy of 25 MV. MR scanning was performed on a 3 T whole body scanner (MEDSPEC 30/80, BRUKER BIOSPIN, Ettlingen, Germany) using several coils and different gradient systems adapted to the acquired spatial resolution investigated. For T2-parameter selective imaging and determination of the relaxation rate R2 = 1/T2, a multiple spin echo sequence with 20 equidistant echoes was used. With regard to preirradiation induced variations R2 increases significantly with the increasing time interval between the polymer gel preparation and irradiation. Only a slight increase in R2 can be observed for varying the postirradiation-time solely. The dose reproducibility at voxel volumes of about 1.4 x 1.4 x 2 mm3 is better than 2%. The accuracy strongly depends on the calibration curve. THPC represents a very effective oxygen scavenger in methacrylic acid and gelatin. Polymer gels containing THPC offer high sensitivity to dose but their dose response also strongly depends on dose rate in the medium and high dose region.

Animals↗

Development and application of a real-time monitoring and feedback system for deep inspiration breath hold based on external marker tracking.

Respiration can cause tumor movements in thoracic regions of up to 3 cm. To minimize motion effects several approaches, such as gating and deep inspiration breath hold (DIBH), are still under development. The goal of our study was to develop and evaluate a noninvasive system for gated DIBH (GDIBH) based on external markers. DIBH monitoring was based on an infrared tracking system and an in-house-developed software. The in-house software provided the breathing curve in real time and was used as on-line information for a prototype of a feedback device. Reproducibility and stability of the breath holds were evaluated without and with feedback. Thirty-five patients undergoing stereotactic body radiotherapy (SBRT) performed DIBH maneuvers after each treatment. For 16 patients dynamic imaging sequences on a multislice CT were used to determine the correlation between tumor and external markers. The relative reproducibility of DIBH maneuvers was improved with the feedback device (74.5% +/- 17.1% without versus 93.0% +/- 4.4% with feedback). The correlation between tumor and marker was good (Pearson correlation coefficient 0.83 +/- 0.17). The regression slopes showed great intersubject variability but on average the internal margin in a DIBH treatment situation could be theoretically reduced by 3 mm with the feedback device. DIBH monitoring could be realized in a noninvasive manner through external marker tracking. We conclude that reduction of internal margins can be achieved with a feedback system but should be performed with great care due to the individual behavior of target motion.

Artifacts↗

In-vivo dosimetry for gynaecological brachytherapy: physical and clinical considerations.

INTRODUCTION: The study aimed to estimate the dosimetric uncertainty using diodes (PTW/Germany) for a high-dose rate Iridum-192 source under clinical conditions. Finally, the role of in-vivo dosimetry for cervix cancer patients was evaluated. MATERIAL AND METHODS: First, diode calibration and factors influencing diode response were investigated and phantom studies compared doses measured and computed by the treatment planning system. Based on that, the uncertainty for diode measurements was estimated to be 7% (1 sigma). Secondly, 55 applications of patients with cervix carcinoma were evaluated. Doses in rectum and bladder were measured and compared to the computed doses and differences were calculated. If the differences exceeded 10% the corresponding shift in probe position was evaluated. Additionally, the in-vivo dosimetry data were compared to doses at the ICRU 38 [ICRU Report No. 38, dose and volume specification for reporting intracavitary therapy in gynaecology. In: Chassagne D, Dutreix A, Almond P, Burgers J, Busch M, Joslin C editors. International commissioning on radiation units and measurements. Bethesda: 1985.] reference points for rectum and bladder. RESULTS: In patients, in-vivo dosimetry resulted in differences between calculated and measured doses ranging from -31 to+90% (mean 11%) for the rectum and from -27 to+26% (mean 4%) for the bladder. Shifts in probe position of 2.5mm for the rectal probe and 3.5mm for the bladder probe caused dose differences exceeding 10%. The dose at the ICRU rectum reference point was underestimated by the calculated doses at probe position ranging from -61 to 156% (mean 29%). The dose to the ICRU bladder reference point was underestimated by the calculated dose ranging from 12 to 162% (mean 58%). CONCLUSION: The study shows that diode accuracy and reproducibility is sufficient for clinical applications. For accurate in-vivo dosimetry geometric conditions are of utmost importance. It is recommended that in-vivo dosimetry should be performed in addition to computation.

Brachytherapy↗

Proton beam radiotherapy versus fractionated stereotactic radiotherapy for uveal melanomas: A comparative study.

PURPOSE: A comparative treatment planning study was undertaken between proton and photon therapy in uveal melanoma to assess the potential benefits and limitations of these treatment modalities. A fixed proton horizontal beam (OPTIS) and intensity-modulated spot-scanning proton therapy (IMPT), with multiple noncoplanar beam arrangements, was compared with linear accelerator-based stereotactic radiotherapy (SRT), using a static and a dynamic micromultileaf collimator and intensity-modulated RT (IMRS). METHOD AND MATERIALS: A planning CT scan was performed on a brain metastasis patient, with a 3-mm acquisition slice spacing and the patient looking at a luminous spot with the eyes in three different positions (neutral and 25 degrees right and left). Four different gross tumor volumes were defined for each treatment technique. These target scenarios represented different locations (involving vs. not involving the macula and temporal vs. nasal) and volumes (10 x 6 mm vs. 16 x 10 mm) to challenge the proton and photon treatment techniques. The planning target volume was defined as the gross tumor volume plus 2 mm laterally and 3 mm craniocaudally for both modalities. A dose homogeneity of 95-99% of the planning target volume was used as the "goal" for all techniques. The dose constraint (maximum) for the organs at risk (OARs) for both the proton and the SRT photon plans was 27.5, 22.5, 20, and 9 CGE-Gy for the optic apparatus, retina, lacrimal gland, and lens, respectively. The dose to the planning target volume was 50 CGE-Gy in 10 CGE-Gy daily fractions. The plans for proton and photon therapy were computed using the Paul Scherrer Institute and BrainSCAN, version 5.2 (BrainLAB, Heimstetten, Germany) treatment planning systems, respectively. Tumor and OARs dose-volume histograms were calculated. The results were analyzed using the dose-volume histogram parameters, conformity index (CI(95%)), and inhomogeneity coefficient. RESULTS: Target coverage of all simulated uveal melanomas was equally conformal with the photon and proton modalities. The median CI(95%) value was 1.74, 1.86, and 1.83 for the static, dynamic, and IMSRT plans, respectively. With proton planning, the median CI(95%) was 1.88 for OPTIS and substantially improved with IMPT in some tumor cases (median CI(95%), 1.29). The tumor dose homogeneity in the proton plans was, however, always better than with SRT photon planning (median inhomogeneity coefficient 0.1 and 0.15 vs. 0.46, 0.41, and 0.23 for the OPTIS and IMPT vs. the static, dynamic, and IMSRT plans, respectively). Compared with the photon plans, the use of protons did not lead to a substantial reduction in the homolateral OAR total integral dose in the low- to high-dose level, except for the lacrimal gland. The median maximal dose and dose at the 10% volume with the static, dynamic, and IMSRT plans was 33-30.8, 31.8-28, and 35.8-49 Gy, respectively, for the lacrimal gland, a critical organ. For protons, only the OPTIS plans were better, with a median maximal dose and dose at the 10% volume using OPTIS and IMPT of 19.2 and 8.8 and 25.6 and 23.6 CGE, respectively. The contralateral OARs were completely spared with the proton plans, but the median dose delivered to these structures was 1.2 Gy (range, 0-6.3 Gy) with the SRT photon plans. CONCLUSION: These results suggest that the use of SRT photon techniques, compared with protons, can result in similar levels of dose conformation. IMPT did not increase the degree of conformality for this small tumor. Tumor dose inhomogeneity was, however, always increased with photon planning. Except for the lacrimal gland, the use of protons, with or without intensity modulation, did not increase homolateral OAR dose sparing. The dose to all the contralateral OARs was, however, completely eliminated with proton planning.

Brain Neoplasms↗

Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer.

PURPOSE: Magnetic resonance imaging (MRI)-based treatment planning in intracavitary brachytherapy allows optimization of the dose distribution on a patient-by-patient basis. In addition to traditionally used point dose and volume parameters, dose-volume histogram (DVH) analysis enables further possibilities for prescribing and reporting. This study reports the systematic development of our concept applied in clinical routine. METHODS AND MATERIALS: A group of 22 patients treated with 93 fractions using a tandem-ring applicator and MRI-based individual treatment planning for each application was analyzed in detail. High-risk clinical target volumes and gross tumor volumes were contoured. The dose to bladder, rectum, and sigma was analyzed according to International Commission of Radiation Units and Measurements (ICRU) Report 38 and DVH parameters (e.g., D(2cc) represents the minimal dose for the most irradiated 2 cm(3)). Total doses, including external beam radiotherapy and the values for each individual brachytherapy fraction, were biologically normalized to conventional 2-Gy fractions (alpha/beta 10 Gy for target, 3 Gy for organs at risk). RESULTS: The total prescribed dose was about 85 Gy(alphabeta10), which was mainly achieved by 45 Gy external beam radiotherapy plus 4 x 7 Gy brachytherapy (total 84 Gy(alphabeta10)). The mean value was 82 Gy(alphabeta10) for the point A dose (left, right) and 84 cm(3) for the volume of the prescribed dose. The average dose to the clinical target volume was 66 Gy(alphabeta10) for the minimum target dose, 87 Gy(alphabeta10) for the dose received by at least 90% of the volume, with a mean volume treated with at least the prescribed dose of 89%. The mean D(2cc) for the bladder was 83 Gy(alphabeta3), the ICRU point dose was 75 Gy(alphabeta3), and the dose at the ICRU point plus 1.5 cm cranially was 100 Gy(alphabeta3). The average dose to the rectum was 64 Gy(alphabeta3) for D(2cc) and at ICRU point 69 Gy(alphabeta3). The sigma D(2cc) was 63 Gy(alphabeta3). CONCLUSION: A standard loading pattern should be used as the starting point for MRI-based optimization. Individual changes of active dwell positions and dwell weights are guided by a concept of DVH constraints for target and organs at risk. In our clinical routine, the dose to point A and dose received by at least 90% of the volume for the clinical target volume are both comparable to the prescribed dose. The DVH constraints for organs at risk allow reproducible treatment plans, helping to detect and avoid severe overdosage.

Brachytherapy↗

Impact of IMRT and leaf width on stereotactic body radiotherapy of liver and lung lesions.

PURPOSE: The present study explored the impact of intensity-modulated radiotherapy (IMRT) on stereotactic body RT (SBRT) of liver and lung lesions. Additionally, because target dose conformity can be affected by the leaf width of a multileaf collimator (MLC), especially for small targets and stereotactic applications, the use of a micro-MLC on "uniform intensity" conformal and intensity-modulated SBRT was evaluated. METHODS AND MATERIALS: The present study included 10 patients treated previously with SBRT in our institution (seven lung and three liver lesions). All patients were treated with 3 x 12 Gy prescribed to the 65% isodose level. The actual MLC-based conformal treatment plan served as the standard for additional comparison. In total, seven alternative treatment plans were made for each patient: a standard (actual) plan and an IMRT plan, both calculated with Helax TMS (Nucletron) using a pencil beam model; and a recalculated standard and a recalculated IMRT plan on Helax TMS using a point dose kernel approach. These four treatment plans were based on a standard MLC with 1-cm leaf width. Additionally, the following micro-MLC (central leaf width 3 mm)-based treatment plans were calculated with the BrainSCAN (BrainLAB) system: standard, IMRT, and dynamic arc treatments. For each treatment plan, various target parameters (conformity, coverage, mean, maximal, and minimal target dose, equivalent uniform doses, and dose-volume histogram), as well as organs at risk parameters (3 Gy and 6 Gy volume, mean dose, dose-volume histogram) were evaluated. Finally, treatment efficiency was estimated from monitor units and the number of segments for IMRT solutions. RESULTS: For both treatment planning systems, no significant difference could be observed in terms of target conformity between the standard and IMRT dose distributions. All dose distributions obtained with the micro-MLC showed significantly better conformity values compared with the standard and IMRT plans using a regular MLC. Dynamic arc plans were characterized by the steepest dose gradient and thus the smallest V(6 Gy) values, which were on average 7% smaller than the standard plans and 20% lower than the IMRT plans. Although the Helax TMS IMRT plans show about 18% more monitor units than the standard plan, BrainSCAN IMRT plans require approximately twice the number of monitor units relative to the standard plan. All treatment plans optimized with a pencil beam model but recalculated with a superposition method showed significant qualitative, as well as quantitative, differences, especially with respect to conformity and the dose to organs at risk. CONCLUSION: Standard conformal treatment techniques for SBRT could not be improved with inversely planned IMRT approaches. Dose calculation algorithms applied in optimization modules for IMRT applications in the thoracic region need to be based on the most accurate dose calculation algorithms, especially when using higher energy photon beams.

Algorithms↗

Interpretation and evaluation of the gamma index and the gamma index angle for the verification of IMRT hybrid plans.

In IMRT, the method for a quantitative comparison of two-dimensional dose distributions is still under development. The gamma evaluation method proposed by Low et al is the most accepted approach and has been adapted by many groups. Based on the concept of Low et al we developed a software tool with an intelligent search algorithm to minimize the calculation time. For the interpretation of deviations a y angle distribution and other tools (dose difference map, profiles, y area histograms, etc) are integrated in the software package. Ten hybrid plans are included in the verification study containing 6 IMRT head and neck cases, 2 IMRT prostate cases and one IMRT paravertebral case as well as a standard uniform intensity conformal 4 field box treatment for comparison. IMRT plans are realized with a segmental MLC delivery technique. The fields of a hybrid plan are applied at once and dose distributions are measured with films in three planes of a verification phantom. All y vector calculations are based on a 3% dose criterion and a 3 mm DTA acceptance criterion. The mean value gamma(mean) (mean value in the y distribution) of the various IMRT plans is 0.45+/-0.10 (1 SD). On average, the percentage of points exceeding the acceptance criteria of gamma < or = 1 (gamma > 1) is 5.8+/-5.4% (1 SD). The mean value of gamma 1% (1% of points have an equal or higher gamma value) is 1.47+/-0.59 (1 SD) for IMRT plans. In 5 out of 27 planes, gamma > 1 is substantially larger than the average. This is also indicated in gamma area histograms. Planes with large areas outside the tolerance criteria were further evaluated using gamma angle distributions. This additional information indicates that the large areas with high gamma values are dominated by the dose difference. It is shown that the deviations are influenced by tongue and groove effects. From the statistical evaluation of gamma values (e.g. gamma area histogram), acceptance criteria for IMRT hybrid plans can be defined. For the interpretation of the gamma maps, distributions of the gamma angle and traditional evaluation methods, such as dose profiles, are still very useful.

Algorithms↗

Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 kV.

The purpose of this study was to investigate the dosimetric characteristics (energy dependence, linearity, fading, reproducibility, etc) of MOSFET detectors for in vivo dosimetry in the kV x-ray range. The experience of MOSFET in vivo dosimetry in a pre-clinical study using the Alderson phantom and in clinical practice is also reported. All measurements were performed with a Gulmay D3300 kV unit and TN-502RDI MOSFET detectors. For the determination of correction factors different solid phantoms and a calibrated Farmer-type chamber were used. The MOSFET signal was linear with applied dose in the range from 0.2 to 2 Gy for all energies. Due to fading it is recommended to read the MOSFET signal during the first 15 min after irradiation. For long time intervals between irradiation and readout the fading can vary largely with the detector. The temperature dependence of the detector signal was small (0.3% degrees C(-1)) in the temperature range between 22 and 40 degrees C. The variation of the measuring signal with beam incidence amounts to +/-5% and should be considered in clinical applications. Finally, for entrance dose measurements energy-dependent calibration factors, correction factors for field size and irradiated cable length were applied. The overall accuracy, for all measurements, was dominated by reproducibility as a function of applied dose. During the pre-clinical in vivo study, the agreement between MOSFET and TLD measurements was well within 3%. The results of MOSFET measurements, to determine the dosimetric characteristics as well as clinical applications, showed that MOSFET detectors are suitable for in vivo dosimetry in the kV range. However, some energy-dependent dosimetry effects need to be considered and corrected for. Due to reproducibility effects at low dose levels accurate in vivo measurements are only possible if the applied dose is equal to or larger than 2 Gy.

Equipment Design↗

Comparative treatment planning on localized prostate carcinoma conformal photon- versus proton-based radiotherapy.

PURPOSE: To assess the potential benefit of proton-beam therapy in comparison to 3-D conformal photon therapy and photon- based intensity-modulated radiotherapy (IMRT) in prostate carcinoma for various stages of disease. MATERIAL AND METHODS: In five patients a 3-D conformal proton-based (two lateral beams) irradiation technique was compared with 3-D conformal photon-beam radiotherapy (four-field box) and IMRT (seven beams). For each patient different target volumes (CTVs) were defined according to early, intermediate and advanced stages of disease: CTV I consisted of the prostate gland, CTV II encompassed prostate and basis of seminal vesicles, and CTV III the prostate and seminal vesicles. Corresponding planning target volumes PTV I-III were defined by uniformly adding a margin of 5 mm to CTV I-III. Dose-volume histograms (DVHs) were analyzed for the different PTVs and various organs at risk (OARs), i.e., rectal wall, bladder, both femoral heads. In addition, maximum and mean doses were derived for the various structures and irradiated non-target tissue volumes were compared for PTV I-III and the different irradiation techniques. Finally, dose conformity and target dose homogeneity were assessed. RESULTS: With photon- and proton-based radiotherapy techniques similar dose distributions were determined for PTV I-III: mean and maximum PTV dose values were between 99-104% and 102-107% of the normalized total doses (70 Gy), respectively. Conformity indices varied from 1.4 to 1.5 for the photon techniques, whereas for proton-beam radiotherapy values ranged from 1.1 to 1.4. Both the 3-D conformal and the IMRT photon treatment technique resulted in increased mean doses (approximately 40-80%) for OARs when compared to protons. With both photon techniques non-target tissue volumes were irradiated to higher doses (mean dose difference > or = 70%) compared to proton-beam radiotherapy. Differences occurred mainly at the low and medium dose levels, whereas in high dose levels similar values were obtained. In comparison to conformal 3-D treatments IMRT reduced doses to OARs in the medium dose range, especially for the rectal wall. CONCLUSION: IMRT enabled dose reductions to OARs in the medium dose range compared to 3-D conformal radiotherapy. A rather simple two-field proton-based treatment technique further reduced doses to OARs compared to photon-beam radiotherapy. The advantageous dose distribution of proton-beam therapy for prostate cancer may result in reduced side effects, which needs to be confirmed in clinical studies.

Femur↗