Dosimetric quality assurance for intensity-modulated radiotherapy feasibility study for a filmless approach.

PURPOSE: Test and comparison of various 2-D real-time detectors for dosimetric quality assurance (QA) of intensity-modulated radiotherapy (IMRT) with the vision to replace radiographic films for 2-D dosimetry. MATERIAL AND METHODS: All IMRT treatment plans were created with the Konrad software (Siemens OCS). The final dose calculation was also carried out in Konrad. A Mevatron Primus (Siemens OCS) linear accelerator which provides 6-MV and 15-MV highenergy photon beams was used for the delivery of segmented multileaf-modulated IMRT. Three different 2-D detectors, each based on a different physical (interaction) principle, were tested for the field-related IMRT verification: (1) the MapCheck diode system (Sun Nuclear), (2) the I'mRT QA scintillation detector (Scanditronix/Wellhöfer), and the Seven29 ionization chamber array (PTW). The performance of these detector arrays was evaluated against IMRT dose distributions created and calculated with Konrad and the results obtained were compared with film measurements performed with radiographic films (EDR2, Kodak). Additionally, measurements were performed with point detectors, such as diamond, diodes (PTW) and ionization chambers (PTW, Scanditronics/ Wellhöfer) and radiochromic films (GafChromic film MD55, ISP). RESULTS: The results obtained with all three 2-D detector systems were in good agreement with calculations performed with the treatment-planning system and with the standard dosimetric tools, i.e., films or various point dose detectors. It could be shown that all three systems offer dosimetric characteristics required for performing field-related IMRT QA with relative dose measurements. The accuracy of the 2-D detectors was mostly +/- 3% normalized to dose maximum for a wide dynamic range. The maximum deviations did not exceed +/- 5% even in regions with a steep dose gradient. The main differences between the detector systems were the spatial resolution, the maximal field size, and the ability to perform absolute dosimetric measurements. CONCLUSION: Commercial 2-D detectors have the potential to replace films as an "area detector" for field-related verification of IMRT. The on-line information provided by the respective systems can even improve the efficiency of the QA procedures.

Germany↗

Comparison of the ESTRO formalism for monitor unit calculation with a Clarkson based algorithm of a treatment planning system and a traditional "full-scatter" methodology.

The ESTRO formalism for monitor unit (MU) calculations was evaluated and implemented to replace a previous methodology based on dosimetric data measured in a full-scatter phantom. This traditional method relies on data normalised at the depth of dose maximum (Zm), as well as on the utilisation of the BJR 25 table for the conversion of rectangular fields into equivalent square fields. The treatment planning system (TPS) was subsequently updated to reflect the new beam data normalised at a depth ZR of 10 cm. Comparisons were then carried out between the ESTRO formalism, the Clarkson-based dose calculation algorithm on the TPS (with beam data normalised at Zm and ZR), and the traditional "full-scatter" methodology. All methodologies, except for the "full-scatter" methodology, separated head-scatter from phantom-scatter effects and none of the methodologies; except for the ESTRO formalism, utilised wedge depth dose information for calculations. The accuracy of MU calculations was verified against measurements in a homogeneous phantom for square and rectangular open and wedged fields, as well as blocked open and wedged fields, at 5, 10, and 20 cm depths, under fixed SSD and isocentric geometries for 6 and 10 MV. Overall, the ESTRO Formalism showed the most accurate performance, with the root mean square (RMS) error with respect to measurements remaining below 1% even for the most complex beam set-ups investigated. The RMS error for the TPS deteriorated with the introduction of a wedge, with a worse RMS error for the beam data normalised at Zm (4% at 6 MV and 1.6% at 10 MV) than at ZR (1.-9% at 6 MV and 1.1% at 10 MV). The further addition of blocking had only a marginal impact on the accuracy of this methodology. The "full-scatter" methodology showed a loss in accuracy for calculations involving either wedges or blocking, and performed worst for blocked wedged fields (RMS errors of 7.1% at 6 MV and 5% at 10 MV). The origins of these discrepancies were quantified and the shortcomings of these MU calculation methodologies are discussed in the paper.

Algorithms↗

Dose-response characteristics of an amorphous silicon EPID.

Electronic portal imaging devices (EPIDs) were originally developed for the purpose of patient setup verification. Nowadays, they are increasingly used as dosimeters (e.g., for IMRT verification and linac-specific QA). A prerequisite for any clinical dosimetric application is a detailed understanding of the detector's dose-response behavior. The aim of this study is to investigate the dosimetric properties of an amorphous silicon EPID (Elekta IVIEWGT) with respect to three photon beam qualities: 6, 10, and 25 MV. The EPID showed an excellent temporal stability on short term as well as on long term scales. The stability throughout the day was strongly influenced by warming up, which took several hours and affected EPID response by 2.5%. Ghosting effects increased the sensitivity of the EPID. They became more pronounced with decreasing time intervals between two exposures as well as with increasing dose. Due to ghosting, changes in pixel sensitivity amounted up to 16% (locally) for the 25 MV photon beam. It was observed that the response characteristics of our EPID depended on dose as well as on dose rate. Doubling the dose rate increased the EPID sensitivity by 1.5%. This behavior was successfully attributed to a dose per frame effect, i.e., a nonlinear relationship between the EPID signal and the dose which was delivered to the panel between two successive readouts. The sensitivity was found to vary up to 10% in the range of 1 to 1000 monitor units. This variation was governed by two independent effects. For low doses, the EPID signal was reduced due to the linac's changing dose rate during startup. Furthermore, the detector reading was influenced by intrabeam variations of EPID sensitivity, namely, an increase of detector response during uniform exposure. For the beam qualities which were used, the response characteristics of the EPID did not depend on energy. Differences in relative dose-response curves resulted from energy dependent temporal output characteristics of the accelerator. If ghosting is prevented from affecting the results and all dose-response effects are properly corrected for, the EPID signal becomes independent of dose rate, dose, and exposure time.

Artifacts↗

Treatment parameters for beta and gamma devices in peripheral endovascular brachytherapy.

PURPOSE: To determine dosimetric parameters, such as radial and longitudinal dose profiles, for beta and gamma devices in peripheral endovascular brachytherapy. METHODS AND MATERIALS: An (192)Ir high-dose rate stepping source, a (90)Sr source train, and a (32)P-coated radiation balloon were investigated. The treatment-planning software PLATO, Monte Carlo code EGSnrc, and GafChromic film dosimetry were used to analyze the dose distribution of these devices. RESULTS: For a 5-mm-diameter vessel, the ratio between the dose at 2 mm depth and the dose at the lumen surface was 1.8, 3.4, and 16.2 for the (192)Ir, (90)Sr, and (32)P devices, respectively. The dose variation at the reference depth of 2 mm into the vessel wall was 7-18 Gy, for different analyzed dose prescriptions. The reference lumen dose was different by a factor >8. For all three devices, the reference isodose length was not <5 mm on the proximal and distal edge of the active source length. CONCLUSIONS: A complete set of dose parameters for beta and gamma sources has to be considered for appropriate treatment planning and performance, including reporting of reference depth dose, reference lumen dose, and reference isodose length.

Arteries↗

The use of the source-skin distance measuring bridge indeed reduces skin teleangiectasia after interstitial boost in breast conserving therapy.

BACKGROUND AND PURPOSE: In 1990 the skin source measuring bridge was proposed as a tool to measure (1) the distance between the interstitial implant and the overlying skin during brachytherapy boost treatment as well as (2) the distances between the lateral source end and the exit point of the guide needle. The present study reports on the clinical experience using the source skin measuring bridge with respect to incidence and grade of teleangiectasia, and their relation to source skin distances and doses. PATIENTS AND METHODS: Two hundred and twenty-two breast cancer patients (229 breasts) treated between 1983 and 1996 with breast conserving therapy including a brachytherapy boost were scored on the occurrence of teleangiectasia. The minimum distance between the sources (above implant and laterally) and the skin surface were measured. RESULTS: If no bridge was used the appearance of teleangiectasia in the epiderm above the implant is 77, 63 and 50% for boost doses of 25, 20 and 15 Gy, respectively. For brachytherapy boost doses of 25 and 20 Gy and distances smaller than 10mm between the implant and the overlying epiderm, as determined with the skin source measuring bridge, the appearance of teleangiectasia was 78 and 46%, respectively. When respecting provisional dosimetry to spare the skin for a boost dose of 15 Gy, resulting in distances between 10 and 15 mm for the implant overlying skin and distances between 5 and 10 mm for the lateral skin, teleangiectasia can be reduced to a minimum (6.3% above and 3.3% laterally). While in a univariate analysis several parameters (use of the bridge, boost dose, boost modality, external beam therapy modality) were predictive factors, the use of the bridge remained the only significant variable in a multivariate analysis. CONCLUSIONS: The skin source measuring bridge reduces teleangiectasia after interstitial brachytherapy boost treatment. A hypothesis made previously relating teleangiectasia and source skin distances was verified and extended. Even when 3D planning is used, the bridge allows for a provisional calculation of the security margins between source positions and the skin at the time of BT implantation to assure a correct needle positioning from the beginning, instead of correcting dwell times later on to avoid unnecessary high skin doses.

Adult↗

A practical method to calculate head scatter factors in wedged rectangular and irregular MLC shaped beams for external and internal wedges.

Factor based methods for absorbed dose or monitor unit calculations are often based on separate data sets for open and wedged beams. The determination of basic beam parameters can be rather time consuming, unless equivalent square methods are applied. When considering irregular wedged beams shaped with a multileaf collimator, parametrization methods for dosimetric quantities, e.g. output ratios or wedge factors as a function of field size and shape, become even more important. A practical method is presented to derive wedged output ratios in air (S(c,w)) for any rectangular field and for any irregular MLC shaped beam. This method was based on open field output ratios in air (S(c)) for a field with the same collimator setting, and a relation f(w) between S(c,w) and S(c). The relation f(w) can be determined from measured output ratios in air for a few open and wedged fields including the maximum wedged field size. The function f(w) and its parametrization were dependent on wedge angle and treatment head design, i.e. they were different for internal and external wedges. The proposed method was tested for rectangular wedged fields on three accelerators with internal wedges (GE, Elekta, BBC) and two accelerators with external wedges (Varian). For symmetric regular beams the average deviation between calculated and measured S(c,w) / S(c) ratios was 0.3% for external wedges and about 0.6% for internal wedges. Maximum deviations of 1.8% were obtained for elongated rectangular fields on the GE and ELEKTA linacs with an internal wedge. The same accuracy was achieved for irregular MLC shaped wedged beams on the accelerators with MLC and internal wedges (GE and Elekta), with an average deviation < 1% for the fields tested. The proposed method to determine output ratios in air for wedged beams from output ratios of open beams, combined with equivalent square approaches, can be easily integrated in empirical or semi-empirical methods for monitor unit calculations.

Algorithms↗

Treatment planning comparison of conventional, 3D conformal, and intensity-modulated photon (IMRT) and proton therapy for paranasal sinus carcinoma.

PURPOSE: To determine the potential improvements in patients with paranasal sinus carcinoma by comparing proton and intensity-modulated radiotherapy (IMRT) with conventional and conformal photon treatment planning techniques. METHODS AND MATERIALS: In 5 patients, comparative treatment planning was performed by comparing proton plans and related conventional, conformal, and IMRT photon plans. The evaluations analyzed dose-volume histogram findings of the target volumes and organs at risk (OARs, i.e., pituitary gland, optical pathway structures, brain, nontarget tissue). RESULTS: The mean and maximal doses, dose inhomogeneities, and conformity indexes for the planning target volumes were comparable for all techniques. Photon plans resulted in greater volumes of irradiated nontarget tissues at the 10-70% dose level compared with the corresponding proton plans. The volumes thereby increased by a factor of 1.3-3.1 for conventional, 1.1-3.8 for conformal, and 1.1-3.7 for IMRT. Compared with conventional techniques, conformal and IMRT photon treatment planning options similarly reduced the mean dose to the OARs. The use of protons further reduced the mean dose to the OARs by up to 65% and 62% compared with the conformal and IMRT technique, respectively. CONCLUSION: Compared with conventional treatment techniques, conformal RT and IMRT similarly enabled dose reductions to the OARs. Additional improvements were obtained using proton-based treatment planning modalities.

Humans↗

Clinical quality assurance for endovascular brachytherapy devices.

BACKGROUND AND PURPOSE: Endovascular brachytherapy is still an important therapy modality with a high number of treated patients per year. Quality assurance of devices used has been addressed already in several publications (AAPM, DGMP, ESTRO, NCS). However, there are no clear recommendations given on test procedures and related equipment. Our experience with four different devices containing beta- ((32)P, (90)Sr/Y) and gamma-sources ((192)Ir), which were used in clinical routine during the last 3 years is described. PATIENTS AND METHODS: The incoming check includes leakage radiation, missing catheter interlock, positioning test, timer check, interrupt button check, power-off test and verification of the manual retraction facility. Dose profiles are measured using GafChromic film. Source strength verification is performed using well type chambers or air-kerma measurements. In addition, the proposed reference absorbed dose rate at 2 mm distance from the source centre is measured with a dedicated film dosimetry technique where two additional films are exposed to two known doses in a (60)Co field for calibration. RESULTS: Dosimetrical parameters (dose profiles, source strength) are found to be within +/-10% of the manufacturers specifications. The reference dose rate measured with film is on average +3.1% for 13 (90)Sr seed trains, +8.1% for three (32)P wire sources and -3.7% for one (192)Ir seed ribbon compared to the source certificate. The activity of 30 individual (32)P wire sources measured by using a calibrated well type chamber showed a deviation of mean -0.3%, the activity of 16 (192)Ir seed ribbons determined with air kerma measurements a deviation of mean 2.8%. CONCLUSIONS: The QA programme introduced in our department provides methods to verify all relevant parameters proposed by international recommendations. Film dosimetry can be used as independent verification of the reference dose rate within a 10% limit.

Beta Particles↗

Quality assurance in intracoronary brachytherapy. Recommendations for determining the planning target length to avoid geographic miss.

BACKGROUND AND PURPOSE: A new method of assessing geographic miss (GM) in endovascular brachytherapy (EVBT) is applied to evaluate the quality of intracoronary brachytherapy treatments, retrospectively. Based on the Vienna experience, recommendations for adequate safety margins are derived to avoid GM. PATIENTS AND METHODS: Evaluation is done on 136 vessels of 128 consecutive patients treated between October 1999 and July 2001. The quality of EVBT is assessed using the concept and terminology of the EVA GEC ESTRO task group. Evaluation of GM and/or safety margin is performed by comparing the outermost interventions with the reference isodose length (RIL) of the applied delivering devices on recorded compact disk (CD) angiograms. The RIL is defined as the length of the vessel segment, which receives at least 90% of the reference dose at the reference depth (=1 mm within the vessel). GM is defined as injured vessel segments, which receive a dose lower than 90% of reference dose. Measurements of intervention length (IL) and active source length (ASL) are performed with respect to anatomical landmarks within the vessel in the region of interest (e.g. stent edges), and by using the nominal length of the devices (balloons, sources) as a reference scale. The edges of RIL are determined by subtracting the length of the dose-fall-off zone (specific to the applied delivery devices: (192)Ir 4.5 mm, (90)Sr 2.5 mm, (32)P 2.0 mm) from the edges of ASL. RESULTS: The described method to assess GM is applicable to 128 vessels (94%). GM is found in 23% of proximal edges and 20% of distal edges. 95% of all GM are observed if the total margin (proximal+distal margin) between RIL and IL is shorter than 10.5 mm. CONCLUSIONS: GM in intracoronary brachytherapy can be widely avoided by adding an appropriate safety margin to the IL (5-6 mm each edge in this study) in order to determine the necessary RIL for a treatment.

Brachytherapy↗

Basic treatment planning parameters for a 90Sr / 90Y source train used in endovascular brachytherapy.

Working groups of the AAPM, DGMP, and ESTRO have published recommendations for endovascular brachytherapy, introducing concepts of relevant parameters for dose specification and treatment planning. However, the procedures for this treatment remain often mainly based on trial protocols and manufacturer instructions. Treatment planning requires the essential knowledge of the radial and longitudinal dose distribution, as well as information about geometrical uncertainties. The present study includes a whole data set for daily clinical practice using a commercially available device for endovascular brachytherapy (Novoste Betacath). The dose distribution around the 90Sr seed train was calculated with Monte-Carlo algorithms and verified by film dosimetry. The radial dose profile was determined starting from the surface of the delivery catheter Calculated dose profiles were in good agreement to measured values. The geometrical uncertainties were estimated with a retrospective analysis of 51 patient treatments. This shows the importance of using a safety margin of at least 10 mm between Intervention Length and Reference Isodose Length. Based on the longitudinal dose profile and the necessary safety margins, the maximum treatable intervention length is 25 mm and 45 mm for a 40 mm and 60 mm source train, respectively.

Algorithms↗

Estimation of doses to personnel and patients during endovascular brachytherapy applications.

In the last few years coronary endovascular brachytherapy using gamma- and beta-emitting radionuclides has been established as a standard treatment procedure to prevent restenosis after percutaneous coronary interventions. Direct measurements and calculations were made to determine personnel doses and organ doses of patients due to gamma rays of 192Ir and beta rays of 90Sr/90Y and 32P sources. In general, our results show that the dose levels are low compared with the X-ray exposure from angiography. The dose rate from bremsstrahlung at 1 m distance from a device containing a 90Sr/90Y source of 2.3 GBq is 4 micro Sv h(-1). The skin dose from beta rays during source transfer into and from the patient was estimated with the directional dose equivalent H'(0.07) of 10 micro Sv at 1 m distance from the catheter. By maintaining safe distances, the dose levels can be kept well within annual dose limits.

Beta Particles↗

On empirical methods to determine scatter factors for irregular MLC shaped beams.

Multileaf collimators (MLCs) are in clinical use for more than a decade and are a well accepted tool in radiotherapy. For almost each MLC design different empirical or semianalytical methods have been presented for calculating output ratios in air for irregularly shaped beams. However, until now no clear recommendations have been given on how to handle irregular fields shaped by multileaf collimators for independent monitor unit (MU) verification. The present article compares different empirical methods, which have been proposed for independent MU verification, to determine (1) output ratios in air (Sc) and (2) phantom scatter factors (Sp) for irregular MLC shaped fields. Ten dedicated field shapes were applied to five different types of MLCs (Elekta, Siemens, Varian, Scanditronix, General Electric). All calculations based on empirical relations were compared with measurements and with calculations performed by a treatment planning system with a fluence based algorithm. For most irregular MLC shaped beams output ratios in air could be adequately modeled with an accuracy of about 1%-1.5% applying a method based on the open field aperture defined by the leaf and jaw setting combined with the equivalent square formula suggested by Vadash and Bjärngard [P. Vadash and B. E. Bjärngard, Med. Phys. 20, 733-734 (1993)]. The accuracy of this approach strongly depends on the inherent head scatter characteristics of the accelerator in use and on the irregular field under consideration. Deviations of up to 3% were obtained for fields where leaves obscure central parts of the flattening filter. Simple equivalent square methods for Sp calculations in irregular fields did not provide acceptable results (deviations mostly >3%). Sp values derived from Clarkson integration, based on published tables of phantom scatter correction factors, showed the same accuracy level as calculations performed using a pencil beam algorithm of a treatment planning system (in a homogeneous media). The separation of head scatter and phantom scatter contributions is strongly recommended for irregular MLC shaped beams as both contributions have different factors of influence. With rather simple methods Sc and Sp can be determined for independent MU calculation with an accuracy better than 1.5% for most clinical situations encountered in conformal radiotherapy.

Algorithms↗

Automatic real-time surveillance of eye position and gating for stereotactic radiotherapy of uveal melanoma.

A new prototype (hardware and software) for monitoring eye movements using a noninvasive technique for gated linac-based stereotactic radiotherapy (SRT) of uveal melanoma was developed. The prototype was tested within the scope of a study for 11 patients. Eye immobilization was achieved by having the patient fixate a light source integrated into the system. The system is used in conjunction with a Head&Neck mask system for immobilization, and uses infrared tracking technology for positioning (both BrainLAB AG Heimstetten/Germany). It was used during CT and MR image acquisition as well as during all of five treatment fractions (6 MeV, 5 x 12 Gy to 80% isodose) to guarantee identical patient setup and eye rotational state during treatment planning and treatment delivery. Maximum temporal and angular deviations tolerated during treatment delivery can be chosen by the physician, the radiation then being interrupted automatically and instantaneously if those criteria are being exceeded during irradiation. A graphical user interface displays life video images of the treated eye and information about the current and previous rotational deviation of the eye from its reference treatment position. The physician thus has online access to data directly linked to the success of the treatment and possible side effects. Mean angular deviations during CT/MR scans and treatment deliveries ranged from 1.61 degrees to 3.64 degrees (standard deviations 0.87 degrees to 2.09 degrees ) which is in accordance with precision requirements for SRT. Typical situations when preset deviation criteria were exceeded are slow drifts (fatigue), sudden large eye movements (irritation), or if patients closed their eyes (fatigue). In these cases radiation was reliably interrupted by the gating system. In our clinical setup the novel system for computer-controlled eye movement gated treatments was well tolerated by all patients. The system yields quantitative real-time information about the eye's rotational state with respect to a reference position (treatment planning situation). Together with the possibility of performing movement-gated treatments of uveal melanoma, the system thus greatly improves the quality of this treatment.

Eye↗

A noninvasive eye fixation and computer-aided eye monitoring system for linear accelerator-based stereotactic radiotherapy of uveal melanoma.

PURPOSE: To introduce a noninvasive eye fixation and computer-aided eye monitoring system for linear accelerator-based stereotactic radiotherapy for uveal melanoma. METHODS AND MATERIALS: At the Department of Radiotherapy and Radiobiology, University of Vienna, stereotactic radiotherapy is offered to patients with uveal melanoma considered unsuitable for (106)Ru brachytherapy or local resection. For the present feasibility study, 8 patients were carefully selected according to their ability to fixate a small light source with the diseased eye and whether they had a rather small head to meet the limited geometric space available. A polymethyl methacrylate tube was attached to a stereotactic mask system in craniocaudal orientation supporting a 45 degrees mirror, which was placed in front of the diseased eye. At the other end of the tube, the patient was given a small fixation light, and a small camera was positioned beneath, which was shielded for use during MRI. A computer interface calculated and visualized the spatial difference of the actual and a given reference pupil position, which was defined before CT scanning, during the MRI sequences, and during treatment delivery at the linear accelerator. RESULTS: The described system can be attached to a conventional stereotactic mask system with minor modifications. Because of the large distance between the eye and the fixation light, the optical fixation system was well tolerated by all patients, and a stable position of the eye was obtained. The camera system can be used during CT and MRI without interference. Absorption of the 6-MV photon beam by the mirror and the polymethyl methacrylate tube was negligible. The computer interface designed to determine the pupil position uses an image-processing algorithm that correlates a template of the reference image with the actual image of the eye. Provided sufficient illumination of the pupil, the correlation function showed a pronounced minimum at the reference position. The precision of the algorithm was tested by phantom measurements. For a given 1 mm or 2 mm displacement, the interface reported a mean shift of 0.96 +/- 0.18 mm or 2.07 +/- 0.11 mm, respectively. CONCLUSION: The results of this study demonstrated the feasibility of a new optical fixation system for linear accelerator-based stereotaxis. The artifact-free application of the camera system during image acquisition and irradiation and the use of the computer interface, which automatically monitored eye movements with submillimeter precision, provided large improvements compared with existing techniques. Given well-defined interruption criteria and accelerated image processing, the described system has a high potential to perform automatically gated treatment beam delivery in the near future.

Humans↗

Impact of a micromultileaf collimator on stereotactic radiotherapy of uveal melanoma.

PURPOSE: To evaluate the impact of a micro multileaf collimator (mMLC) on Linac-based stereotactic radiotherapy (SRT) of uveal melanoma by comparing circular arc with static conformal, dynamic arc, and intensity-modulated SRT. MATERIALS AND METHODS: Forty uveal melanoma patients were selected from approximately 100 patients treated with SRT since 1996. For each patient, four treatment plans (BrainSCAN XL, V5.0) were made: conventional arc, static conformal, dynamic arc plan, and intensity-modulated radiotherapy (IMRT). The goal of treatment planning was to fully encompass the planning target volume (PTV) by the 80% isodose while minimizing doses to the optic nerve and lens. The following parameters were evaluated: target conformity; target homogeneity; ratio of the target volume and 50% isodose volume; normal tissue receiving doses >/=80%, >/=50%, and >/=20%; central nervous system volume irradiated to >/=20%; optical nerve volume irradiated >/=50%, D(max) of the lens; lens volume receiving >/=20%; and monitor units. RESULTS: PTVs ranged from 0.68 to 4.90 cm(3) (mean 1.97 +/- 0.97 cm(3)). The average reduction of the prescription isodose volume was 1-1.5 cm(3) for conformal (range 2.6-0.3 cm(3)), dynamic arc (range 2.5-0.3 cm(3)), and IMRT plans (range 3.9-0.1 cm(3)), compared with conventional arc therapy. Central nervous system volumes irradiated to doses >/=20% were smallest for conventional or dynamic arc treatments. Average target dose homogeneity values were 1.74 +/- 0.50 for arc, 1.27 +/- 0.02 for static mMLC, 1.26 +/- 0.01 for dynamic arc, and 1.15 +/- 0.03 for IMRT plans. IMRT helped to reduce doses to the lens but did not provide an advantage for optical nerve sparing. When applying IMRT, the monitor units increased by approximately one-third compared with static mMLC-based SRT. CONCLUSIONS: Conformal mMLC and dynamic arc SRT are the treatment options of choice for Linac-based SRT of uveal melanoma. They present dosimetric advantages, while being highly efficient in treatment planning and delivery.

Humans↗

LINAC based stereotactic radiotherapy of uveal melanoma: 4 years clinical experience.

PURPOSE: To study local tumor control and radiogenic side effects after fractionated LINAC based stereotactic radiotherapy for selected uveal melanoma. PATIENTS AND METHODS: Between June 1997 and March 2001, 90 patients suffering from uveal melanoma were treated at a LINAC with 6 MV. The head was immobilized with a modified stereotactic frame system (BrainLAB). For stabilization of the eye position a light source was integrated into the mask system in front of the healthy or the diseased eye. A mini-video camera was used for on-line eye movement control. Tumors included in the study were either located unfavorably with respect to macula and optical disc (<3 mm distance) or presented with a thickness >7 mm. Median tumor volume was 305+/-234 mm3 (range 70-1430 mm3), and mean tumor height was 5.4+/-2.3 mm (range 2.7-15.9 mm). Total doses of 70 (single dose 14 Gy @ 80% isodose) or 60 Gy (single dose 12 Gy @ 80% isodose) were applied in five fractions within 10 days. The first fractionation results in total dose (TD) (2 Gy) of 175 Gy for tumor and 238 Gy for normal tissue, corresponding values for the second fractionation schedule are 135 and 180 Gy, respectively. RESULTS: After a median follow-up of 20 months (range 1-48 months) local control was achieved in 98% (n=88). The mean relative tumor reductions were 24, 27, and 37% after 12, 24 and 36 months. Three patients (3.3%) developed metastases. Secondary enucleation was performed in seven patients (7.7%). Long term side effects were retinopathy (25.5%), cataract (18.9%), optic neuropathy (20%), and secondary neovascular glaucoma (8.8%). CONCLUSION: Fractionated LINAC based stereotactic photon beam therapy in conjunction with a dedicated eye movement control system is a highly effective method to treat unfavorably located uveal melanoma. Total doses of 60 Gy (single dose 12 Gy) are considered to be sufficient to achieve good local tumor control.

Adult↗

A widely tested model for head scatter influence on photon beam output.

PURPOSE: To construct and test a semi-analytical model describing the effects on Monitor Unit (MU) verification caused by scattering in the treatment head. The implementation of the model should be accomplished using a small set of experimental data. Furthermore, the model should include a geometry dependent estimation of the resulting uncertainty. MATERIAL AND METHODS: The input required by the created model consists of basic treatment head geometry and 10 measured output factors in air (OFair) for square fields. It considers primary energy fluence, scattered radiation from an extra-focal source and from secondary collimators, as well as backscatter to the monitor chamber. Measurements and calculations were performed in open symmetric and asymmetric fields at points located both on and off the collimator axis, as well as at arbitrary treatment distances. The model has been verified for 19 photon beams in the range from 4 up to 50 MV, provided by nine different treatment units from six manufacturers. RESULTS: The presented model provided results with errors smaller than 1% (2 S.D.) in typical clinical situations for all beams tested. In more exceptional situations, i.e. combinations of unconventional treatment head designs, very elongated fields, and dosimetry points far away from the isocenter, the total uncertainty increased to approximately 2%. The spread in the results was further analysed in order to create a method for predicting the uncertainties under different treatment conditions. CONCLUSIONS: A general head scatter model that is easy to implement has been developed and can be used as the basis for computerised MU verification. The model handles all commercially available treatment units adequately and also includes an estimation of the resulting uncertainty.

Models, Theoretical↗

Normalized sensitometric curves for the verification of hybrid IMRT treatment plans with multiple energies.

With the clinical implementation of time-variable dose patterns and intensity modulated radiotherapy (IMRT) film dosimetry has regained popularity. Films are currently the most frequently used dosimetric means for patient specific quality assurance in IMRT. A common method is to verify a so-called hybrid IMRT plan, which is the patient specific treatment plan with unmodified fluence patterns recalculated in a dedicated phantom. For such applications the sensitometric curve, i.e., the relation between optical density (OD) and absorbed dose, should not depend critically on beam energy, field size and depth, or film orientation. In order to minimize the influence of all these variables a normalization of sensitometric curves is performed at various photon beam energies (6 MV, 10 MV, 25 MV). By doing so one unique sensitometric curve can be used for these three beam qualities. This holds for both film types investigated: Kodak X-Omat V films and EDR-2 films. Additionally, the influence of field size, depth and film orientation on a normalized sensitometric curve is determined for both film types. For doses smaller than 0.8 Gy for X-Omat V and doses smaller than 3 Gy for EDR-2 films the field size variation of normalized sensitometric curves is much smaller than 3% for fields up to 20 x 20 cm2. For X-Omat V films all differences between sensitometric curves determined at depths of 5, 10, and 15 cm are smaller than 3%. For EDR-2 films deviations larger than 3% are only observed at low net OD smaller than 0.25. The dependence of film orientation (parallel versus perpendicular) on a normalized sensitometric curve is found to be not critical. However, processing conditions have the largest influence and can result in differences up to 20% for sensitometric curves derived from films of the same batch but using different film processors. When normalizing sensitometric curves to the dose value necessary to obtain a net OD=1 for that respective geometry and energy the large energy dependence of sensitometric curves can be almost eliminated. This becomes especially important for the verification of hybrid IMRT plans with multiple energies. Additionally, such a normalization minimizes other influences such as field size, depth, and film orientation. This method is generally applicable to both Kodak X-Omat V and EDR-2 films. In order to achieve the highest accuracy level an upper dose limit of 0.8 Gy for X-Omat V films and 3 Gy for EDR-2 films should be taken into account. However, these dose limits may vary with film reading instrument and film processor.

Calibration↗