Effect of fish oil on ventricular tachyarrhythmia and death in patients with implantable cardioverter defibrillators: the Study on Omega-3 Fatty Acids and Ventricular Arrhythmia (SOFA) randomized trial.

CONTEXT: Very-long-chain n-3 polyunsaturated fatty acids (omega-3 PUFAs) from fish are thought to reduce risk of sudden death, possibly by reducing susceptibility to cardiac arrhythmia. OBJECTIVE: To study the effect of supplemental fish oil vs placebo on ventricular tachyarrhythmia or death. DESIGN, SETTING, AND PATIENTS: The Study on Omega-3 Fatty acids and ventricular Arrhythmia (SOFA) was a randomized, parallel, placebo-controlled, double-blind trial conducted at 26 cardiology clinics across Europe. A total of 546 patients with implantable cardioverter-defibrillators (ICDs) and prior documented malignant ventricular tachycardia (VT) or ventricular fibrillation (VF) were enrolled between October 2001 and August 2004. Patients were randomly assigned to receive 2 g/d of fish oil (n = 273) or placebo (n = 273) for a median period of 356 days (range, 14-379 days). MAIN OUTCOME MEASURE: Appropriate ICD intervention for VT or VF, or all-cause death. RESULTS: The primary end point occurred in 81 (30%) patients taking fish oil vs 90 (33%) patients taking placebo (hazard ratio [HR], 0.86; 95% confidence interval [CI], 0.64-1.16; P = .33). In prespecified subgroup analyses, the HR was 0.91 (95% CI, 0.66-1.26) for fish oil vs placebo in the 411 patients who had experienced VT in the year before the study, and 0.76 (95% CI, 0.52-1.11) for 332 patients with prior myocardial infarctions. CONCLUSION: Our findings do not indicate evidence of a strong protective effect of intake of omega-3 PUFAs from fish oil against ventricular arrhythmia in patients with ICDs. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00110838.

Aged↗

Near fatal arrhythmia induction by an implantable cardioverter defibrillator.

Sudden death among implantable cardioverter defibrillator (ICD) recipients is well known. The underlying mechanism remains unclear in most cases. One possible mechanism is an accidentally induced arrhythmia by the ICD itself. This report describes for the first time a case of a life-threatening ventricular arrhythmia induced by a specific algorithm for ventricular arrhythmia reconfirmation before shock delivery in a fourth-generation ICD.

Arrhythmias, Cardiac↗

Prognostic value of a restrictive mitral filling pattern in patients with systolic heart failure and an implantable cardioverter-defibrillator.

In patients with chronic heart failure and reduced systolic function, an implantable cardioverter-defibrillator (ICD) improves the prognosis, but morbidity and mortality remain high. We attempted to identify the prognostic impact of Doppler echocardiography and QRS duration in such patients. We prospectively enrolled 84 patients with chronic heart failure, an ICD, and impaired systolic function (mean ejection fraction 29 +/- 10%). Echocardiographic measurements included left ventricular dimensions/volumes, ejection fraction, mitral E/A ratio, deceleration time, and tissue Doppler analysis of mitral annular velocities (S', E', A'). A cardiac event (death from pump failure or appropriate ICD therapy, i.e., antitachycardia pacing/shock due to sustained ventricular tachycardia or ventricular fibrillation) was defined as the study end point. During a follow-up of 373 +/- 254 days, 22 patients (26%) had an event (death from pump failure, n = 7; patients who received an appropriate ICD therapy, n = 16). In patients with an event, the QRS duration was longer (169 +/- 41 vs 146 +/- 37 ms, p = 0.023), the mitral E/E' ratio was higher (16.0 +/- 6.5 vs 12.8 +/- 5.9, p = 0.044), and a restrictive filling pattern was more frequent (44% vs 9%, p = 0.017). Stepwise multivariate Cox regression analysis identified a restrictive filling pattern as the only independent predictor of an event (hazard ratio 3.65, 95% confidence interval 1.54 to 8.64, p = 0.003). For patients with a restrictive filling pattern, the outcome was markedly poorer than that for patients with a nonrestrictive pattern (event-free survival rate 38% vs 72%, p = 0.005). In conclusion, in patients with chronic heart failure, an ICD, and systolic dysfunction, a restrictive filling pattern is an independent predictor of adverse cardiac events.

Aged↗

Clinical assessment of a new real time 3D quantitative coronary angiography system: evaluation in stented vessel segments.

BACKGROUND: Foreshortening is a recognized problem that is present in angiography and results from views that are not perpendicular to coronary lesions. This limits visual coronary analysis as well as 2D quantitative coronary angiography systems (QCA). The CardiOp-B System is a 3D image acquisition and processing software system designed as an add-on to conventional X-ray angiography system. CardiOp-B's features include real time and off line analysis with comprehensive 3D reconstruction integrating all of the available information of two 2D vessel angiographies into one 3D image. It was the aim of the study to analyze the accuracy of this new 3D QCA system. METHODS: 3D QCA was performed in 50 patients (age 64 +/- 10.9; 84% male; LV-EF 63 +/- 16%) measuring 61 stents during high-pressure inflation (diameter: 2.25-4 mm; length: 8-32 mm). The obtained values (proximal and distal stent diameter, stent length) were correlated with the predefined size of the stents at the used inflation pressure. RESULTS: The linear correlation for the proximal stent diameter was Stent(prox)= 0.03 + 0.93 x real stent size (r(2) = 0.85). The linear correlation for the distal stent diameter was Stent(distal)= -0.03 + 0.89 x real stent size (r(2) = 0.81). The linear correlation for the stent length was Stent(length)= -0.61 + 1.02 x real stent length (r(2) = 0.98). CONCLUSIONS: The CardiOp-B System(R) is a new 3D QCA system with a high linear correlation between the real vessel size and the obtained vessel dimension. It provides real time or off line accurate and comprehensive diagnostic information to the interventional cardiologist without changing the basic coronary angiography procedure.

Angioplasty, Balloon, Coronary↗

A trial of self-adhesive patch electrodes and hand-held paddle electrodes for external cardioversion of atrial fibrillation (MOBIPAPA).

AIMS: External electrical cardioversion is the method of choice to terminate persistent atrial fibrillation. Whether the type of shock electrode affects cardioversion success is not known. We tested whether hand-held steel electrodes improve cardioversion outcome with monophasic or biphasic shocks when compared with adhesive patch electrodes. METHODS AND RESULTS: Two hundred and one consecutive patients with persistent atrial fibrillation (147 male, mean age 63+/-1 years, duration of atrial fibrillation 6.3+/-1 months) were randomly assigned to cardioversion using either a sinusoidal monophasic or a truncated exponential biphasic shock wave form. The first half of patients were cardioverted using adhesive patch electrodes, the second half using hand-held steel paddle electrodes, and all patients using an anterior-posterior electrode position. Paddle electrodes successfully cardioverted 100/104 patients (96%) and patch electrodes 85/97 patients (88%, P=0.04). This effect was comparable to that of biphasic shocks: biphasic shocks cardioverted 102/104 patients (98%) and monophasic shocks 83/97 patients (86%, P=0.001). A beneficial effect of paddle electrodes was observed for both shock wave forms. After cross-over from an ineffective monophasic to a biphasic shock, cardioversion was successful in 198/201 (98.5%) patients. Unsuccessful cardioversion after cross-over (3/201 patients) only occurred with patch electrodes (P=0.07). CONCLUSION: Hand-held paddle electrodes increase success of external cardioversion of atrial fibrillation in this trial. This increase is of similar magnitude as the increase in cardioversion success achieved with biphasic shocks. A combination of biphasic shocks, paddle electrodes, and an anterior-posterior electrode position renders outcome of external cardioversion almost always successful (104/104 patients in this trial).

Atrial Fibrillation↗

Long-term prognosis of individuals with right precordial ST-segment-elevation Brugada syndrome.

BACKGROUND: Brugada syndrome is an arrhythmogenic disease characterized by an ECG pattern of ST-segment elevation in the right precordial leads and an increased risk of sudden cardiac death as a result of ventricular fibrillation. Controversy exists with regard to risk stratification and therapeutic management, particularly in asymptomatic individuals. METHODS AND RESULTS: A total of 212 individuals (mean age, 45+/-6 years) with a type 1 Brugada ECG pattern were studied. Of these, 123 (58%) were asymptomatic, 65 (31%) had > or =1 syncope of unknown origin, and 24 (11%) had to be resuscitated because of ventricular fibrillation. In 125 individuals (59%), a spontaneous type 1 ECG was recorded. In the remaining, drug challenge with a class I antiarrhythmic agent unmasked a Brugada ECG. The mean ST elevation was 2.3+/-1.2 mm in symptomatic patients and 1.9+/-1.5 mm in asymptomatic individuals (P=0.04). During a mean follow-up of 40+/-50 months, 4 of the 24 patients (17%) with aborted sudden cardiac death and 4 of 65 (6%) with a prior syncope had a recurrent arrhythmic event, whereas only 1 of 123 asymptomatic individuals (0.8%) had a first arrhythmic event. Four of 9 patients with arrhythmic events during follow-up were not inducible during programmed electrical stimulation. A previous history of aborted sudden death or syncope and the presence of a spontaneous type 1 ECG were predictors of adverse outcome. CONCLUSIONS: The present study reports data on a large population of individuals with a type 1 Brugada ECG pattern with the longest follow-up reported so far. A very low incidence of severe arrhythmic events, particularly in asymptomatic individuals, was found during follow-up. In the presence of very few arrhythmic events on follow-up, programmed electrical stimulation showed very little accuracy in predicting outcome.

Adolescent↗

Arrhythmogenic right ventricular cardiomyopathy. Antiarrhythmic drugs, catheter ablation, or ICD?

Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a major cause of sudden cardiac death and ventricular tachyarrhythmias in young, apparently healthy individuals and athletes. Myocardial atrophy with subsequent fibrofatty replacement predominantly affects right ventricular myocardium and results in global and regional dysfunction as well as areas of slow conduction and dispersion of refractoriness which are prerequisites for reentrant ventricular tachyarrhythmias. Patients affected with ARVC should be excluded from competitive sports and vigorous training. To provide optimal treatment, a detailed diagnostic evaluation and risk stratification are mandatory. Tailored treatment strategies aim at the suppression or effective termination of recurrent ventricular tachyarrhythmias and prevention of sudden death by antiarrhythmic drug therapy, catheter ablation, or implantation of a cardioverter defibrillator (ICD). Antiarrhythmic drugs may be used as a stand-alone treatment to suppress ventricular tachycardia (VT) recurrences in patients with ARVC and low risk of sudden death. Sotalol (preferred) or amiodarone in combination with beta-blockers showed the highest efficacy rates. In patients at higher risk, an ICD should be implanted and antiarrhythmic drugs be used only as an adjunct to prevent or suppress frequent VT recurrences and ICD discharges. Catheter ablation using conventional or electroanatomic mapping techniques yields good acute results for eliminating the targeted arrhythmia substrate. However, during the progressive long-term course of ARVC, VT recurrences from new arrhythmia foci are frequent and therefore limit the curative value of catheter ablation. In patients with frequent VT recurrences and ICD discharges, however, catheter ablation plays an important role as a palliative and adjunctive treatment option for arrhythmia suppression. ICD therapy has been increasingly used for secondary and also primary prevention of sudden death in patients with ARVC. In secondary prevention, the ICD has shown to improve the long-term prognosis of patients at high risk of sudden death by effective termination of life-threatening recurrences of ventricular tachyarrhythmias. However, adequate lead placement may be difficult and lead-related complications during long-term follow-up must be taken into account. The role of ICD therapy for primary prevention of sudden death in ARVC is not yet adequately defined. Ongoing international registries will provide important additional data to improve risk stratification and refine treatment algorithms in order to select the best individual treatment for arrhythmia suppression and prevention of sudden death in patients with ARVC.

Anti-Arrhythmia Agents↗

[Restrictions for ICD patients in daily life].

Patients with an implantable cardioverter defibrillator (ICD) may experience loss of consciousness. Electromagnetic interference (EMI) may trigger undesired or inhibit necessary therapy in patients with an ICD. Therefore, questions about personal or professional activities for ICD patients arise. Restricting driving or other personal activities has adverse effects on the patient's quality of life. The national Societies of Cardiology provide recommendations for ICD patients concerning driving of motor vehicles. Patients with an ICD that is implanted prophylactically do not have to refrain from driving after recovery from the implantation procedure. Patients with arrhythmias are classified into different groups depending on the risk of recurrence of tachycardias and symptoms. Commercial driving is not allowed for patients with an ICD in Germany except for those with a prophylactic indication without a history of arrhythmias. Those patients may drive small cars but no trucks or busses. Guidelines for medical fitness in commercial or military flying are regulated by the Joint Aviation Authorities (JAA) and ventricular tachycardias are a contraindication for both. Fortunately, loss of consciousness is not dangerous in most jobs. Strong sources of EMI can occur at special workplaces. Patients have to be advised and tested individually concerning their risk for EMI at their employment site before returning safely. Modern life exposes to an increasing amount of EMI. Intact household devices usually do not interfere with ICDs. Mobile phones may interfere with implanted devices. Interaction can be minimized by special precautions like maintaining a distance of minimum 10 cm between mobile phone and ICD. Electronic surveillance systems work differently and have the potential to interact with devices. Patients should be advised to pass those systems with avoiding longer exposure. The presence of an ICD is presently a contraindication for undergoing magnetic resonance imaging (MRI) because of a high risk of destruction of the system with even potential harm to the patient. High-frequency application for electrocautery devices or ablation is possible under certain precautions that have to be planned before. There is a high sensitivity of ICD systems to ionizing radiation with defect of the devices after a cumulative dose > 5 Gy.

Accidents, Traffic↗

Implantable dual-chamber defibrillator for the selective treatment of spontaneous atrial and ventricular arrhythmias: arrhythmia incidence and device performance.

INTRODUCTION: Atrial tachyarrhythmias are a common co-morbidity in patients with an ICD indication. Recently introduced ICD's are equipped to independently detect and treat atrial and ventricular tachyarrhythmias. The purpose of this prospective study was to evaluate the incidence and termination of spontaneous atrial and ventricular tachyarrythmias in patients with a history of atrial tachyarrhythmias. METHODS AND RESULTS: Ninety patients, 70% male with an ICD indication and history of atrial tachyarrhythmia (LVEF 45 +/- 6%, [AT/AF indication 55 +/- 10, AT/VT 45 +/- 16], 46% CAD) were enrolled and 89 were implanted with a VENTAK PRIZM AVT (Guidant). Spontaneous atrial and ventricular tachyarrhythmias were printed and evaluated during an average follow-up period of 272 +/- 72 days utilizing the stored intracardial electrogram function of the device. Nineteen patients (21%) presented had only atrial tachyarrhythmias, 32 patients (36%) had both atrial and ventricular tachyarrhythmias and 18 patients (20%) had only ventricular tachyarrhythmias. Patients with only atrial tachyarrhythmias had a total of 3274 atrial episodes; 2002 terminated spontaneously, 1264 were treated with ATP and 8 with shock therapy. ATP was successful in 735 (58%) of 1264 episodes. Patients with both atrial and ventricular tachyarrhythmias had 7277 documented atrial tachyarrhythmias, 5231 terminated spontaneously, 1153 of 2009 were terminated by ATP (57.4%) and 37 by shock therapy (20 patient controlled). Atrial tachyarrhythmias identified as atrial flutter (AT) by the atrial rhythm classification (ARC) algorithm had a higher ATP conversion success rate than episodes identified as atrial fibrillation (AF); 66.7% for AT and 26.4% for AF. Patients with only ventricular tachyarrhythmias had 690 documented episodes, 401 terminated spontaneously, 248 (85.8%) were terminated by ATP and 41 by shock. CONCLUSION: Seventy-seven percent of patients with an ICD indication had spontaneous atrial and/or ventricular tachyharrhythmias within the first 6 months after ICD implantation. ATP therapy terminated 58% of all atrial tachyarrhytmias and 66.7% of the atrial flutters. The dual chamber ICD detected, classified and terminated all ventricular tacharrhythmias appropriately.

Aged↗

Implantable cardioverter-defibrillator therapy in patients with congenital long-QT syndrome: a long-term follow-up.

OBJECTIVES: The purpose of this study was to evaluate retrospectively a single-center experience with the use of ICDs in patients with long QT syndrome (LQTS) concerning outcome, complications, and optimal programming. BACKGROUND: Use of implantable cardioverter-defibrillator (ICD) in patients with congenital LQTS is controversial but is generally accepted in high-risk patients. METHODS: We enrolled 27 symptomatic patients with LQTS undergoing ICD therapy (QTc 540 +/- 64 ms(1/2); 85% female, 63% cardiac arrest; 33% syncope despite beta-blockers; 4% with severe phenotype) and 81 genotyped patients with LQTS undergoing conventional drug therapy (28 LQT1, 39 LQT2, 1 LQT3, 13 LQT5). During a mean follow-up of 65 +/- 34 months, one death occurred in the ICD group that was not LQTS related. A total of 178 appropriate shocks were observed in 10/27 patients (37%), mostly in survivors of cardiac arrest (in 58% of cardiac arrest patients vs. in 20% of non-cardiac arrest patients). RESULTS: In a logistic regression analysis, only QTc interval (121/178 shocks (68%) for QTc > 500 ms(1/2)) and "survived cardiac arrest" were prognostic for ICD shocks. In 30% of patients in the ICD group, multiple shocks occurred and could be reduced after increase of antibradycardia pacing rate, adding beta-blocker therapy, or starting the rate-smoothing algorithm (average 7.1 shocks before to 0.75 shocks after additional intervention annually). CONCLUSION: ICD therapy is a safe and useful tool in high-risk patients with LQTS. QTc interval and cardiac arrest survivors were prognostic factors for appropriate ICD shocks. The results of this large single-center experience suggest that beta-blockers should always be added to ICD therapy. In addition, some patients might benefit from additional antibradycardia pacing, prolonged detection time, and a rate-smoothing algorithm to prevent recurrent episodes.

Adolescent↗

Incidence of complications in patients with implantable cardioverter/defibrillator who receive additional transvenous pace/sense leads.

BACKGROUND: Implantation of an additional pace/sense (P/S) lead is commonly used in patients with implantable cardioverter/defibrillators (ICDs) to overcome P/S defects of integrated defibrillation leads (HV-P/S leads). No information is available about the clinical outcome and the incidence of complications in these patients. METHODS: Retrospective analysis was performed in 151 patients (125 male, age 54.9 +/- 13.6 years, LVEF 48.1 +/- 17.8%, CAD in 86 [57%], DCM in 24 [16%], ARVCM in 11 [7%]) who received an additional P/S lead between 1990 and 2002 (54 patients with abdominal and 97 patients with pectoral ICD system). Statistical analysis was done using Kaplan-Meier survival curves. RESULTS: The average follow-up (FU) after implantation of the additional P/S lead was 43 +/- 27 months. In total 117 patients [77.5%] remain implanted; 22 patients died due to cardiac-related reasons. After a FU of 23 +/- 23 months, 43 patients [28.5%] experienced lead-related problems after implantation of the additional P/S lead: oversensing in 23 [53.5%], insulation defect in 3 [7.0%], fracture in 1 [2.3%], system infection in 4 [9.3%], and defect of the HV-P/S lead in 6 [14.0%] patients. The event-free cumulative survival of the additional P/S lead after 1, 2, and 5 years was 87.0%, 79.8%, and 59.4%, respectively (for pectoral leads: 89.6%, 82.0%, and 60.0%, respectively). CONCLUSIONS: Implantation of an additional P/S lead in case of failure of an HV-P/S lead is safe. However, it is associated with a substantial rate of complications during FU. Therefore, extraction of damaged defibrillation leads instead of implantation of P/S leads should be favored.

Aged↗

Safe performance of magnetic resonance imaging on a patient with an ICD.

This is a report on a patient with an implanted cardioverter defibrillator (ICD) who intentionally underwent magnetic resonance imaging (MRI) of a malignant brain tumor. To avoid inadequate detection of ventricular tachycardia (VT) or ventricular fibrillation (VF), the ICD was inactivated by programming the VT-detection and VT/VF-therapy status off. The patient came through the protocol safely and without any difficulty or discomfort. There was no arrhythmic event. MRI affected neither programmed data nor the function of the ICD system.

Brain Neoplasms↗

Comparison of induced and spontaneous atrial tachyarrhythmias in patients with a history of spontaneous atrial tachyarrhythmias.

INTRODUCTION: This retrospective study investigated whether induced episodes could be used to predict the morphology of future spontaneous atrial episodes. METHODS: Eighty-two patients (64 +/- 12 years; 77% male; CAD in 60%; left ventricular ejection fraction 45 +/- 16%) with a history of atrial tachycardia or atrial fibrillation (AT/AF) were implanted with a dual-chamber implantable cardioverter defibrillator (ICD) and followed for 6 months. A total of 224 episodes of induced and spontaneous AT/AF were classified into type I, II, and III according to the method of Israel et al. and then compared based on average cycle length (CL) and atrial amplitude. Episodes were also grouped as "pace-terminable" or "nonpace-terminable" based on the CL definition of Gillis et al. RESULTS: The analysis of 121 induced episodes (from 80 patients) and 103 spontaneous episodes (from 43 patients) showed that within each arrhythmia type, there were no significant differences in CL or mean amplitude between induced and spontaneous episodes. Additional analysis of patients that had both induced and spontaneous episodes (n = 41) showed 78% had at least one spontaneous episode that matched the induced episode. Fifty-seven percent of spontaneous episodes were considered to be pace-terminable based on CL. CONCLUSIONS: Our data suggest that there is no significant difference between induced and spontaneous episodes of AT/AF of the same type. The majority of patients had at least one spontaneous episode of the same type as the induced episode, showing that induced atrial arrhythmias may be useful in predicting the morphology of future spontaneous episodes and in identifying patients potentially benefiting from atrial antitachycardia pacing.

Adult↗

The 1+1 trial: a prospective trial of a dual- versus a single-chamber implantable defibrillator in patients with slow ventricular tachycardias.

BACKGROUND: The tachycardia detection interval (TDI) in implantable cardioverter/defibrillators (ICDs) is conventionally programmed according to the slowest documented ventricular tachycardia (VT), with a safety margin of 30 to 60 ms. With this margin, VTs above the TDI may occur. However, longer TDIs are associated with an increased risk of inappropriate therapy. We hypothesized that patients with slow VTs (<200 bpm) may benefit from a long TDI and a dual-chamber detection algorithm compared with a conventionally programmed single-chamber ICD. METHODS AND RESULTS: Patients with VTs <200 bpm were implanted with a dual-chamber ICD that was randomly programmed to a dual-chamber algorithm and a TDI of > or =469 ms or to a single-chamber algorithm with a TDI 30 to 60 ms above the slowest documented VT cycle length and the enhancement criteria of cycle length variation and acceleration. The primary combined end point was the number of all inappropriate therapies, VTs above the TDI, and VTs with significant therapy delay (>2 minutes). After 6 months, a crossover analysis was performed. Total follow-up was 1 year. One hundred two patients were included in the study. The programmed TDI was 500+/-36 ms during the dual-chamber phase and 424+/-63 ms during the single-chamber phase. For the primary end point (inappropriate therapies, VTs above the TDI, or VTs with detection delay), a moderate superiority of the dual-chamber mode was found: Mann-Whitney estimator=0.6661; 95% CI, 0.5565 to 0.7758; P=0.0040. CONCLUSIONS: Dual-chamber detection with a longer TDI improves VT detection and does not increase the rate of inappropriate therapies despite a considerable increase in tachycardia burden.

Algorithms↗

Implantable cardioverter/defibrillator therapy in arrhythmogenic right ventricular cardiomyopathy: single-center experience of long-term follow-up and complications in 60 patients.

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a major cause of ventricular tachycardia (VT) and cardiac arrest in young patients. We hypothesized that treatment with implantable cardioverter/defibrillators (ICDs) is safe and improves the long-term prognosis of ARVC patients at high risk of sudden death. METHODS AND RESULTS: Sixty patients with ARVC (aged 43+/-16 years) were treated with transvenous ICD systems. Despite a higher number of right ventricular sites tested for adequate lead positions (P<0.05), lower R-wave amplitudes (P<0.001) were achieved in ARVC patients compared with other entities. During follow-up of 80+/-43 months (396 patient-years), event-free survival was 49%, 30%, 26%, and 26% for appropriate ICD therapies and 79%, 64%, 59%, and 56% for potentially fatal VT (>240 bpm) after 1, 3, 5, and 7 years, respectively. Multivariate analysis identified extensive right ventricular dysfunction as an independent predictor of appropriate ICD discharge. Fifty-three adverse events occurred in 37 patients during the perioperative (n=10) or follow-up (n=43) period, mainly related to the leads (n=31 in 21 patients). No lead perforation was observed. Freedom from adverse events was 90%, 78%, 56%, and 42% and freedom from lead-related complications was 95%, 85%, 74%, and 63% after 1, 3, 5, and 7 years, respectively. CONCLUSIONS: These results strongly suggest an improvement in long-term prognosis by ICD therapy in high-risk patients with ARVC. However, meticulous placement and long-term observation of transvenous lead performance with focus on sensing function are required for the prevention and/or early recognition of disease progression and lead-related morbidity during long-term follow-up of ICD therapy in ARVC.

Adolescent↗

Chronic electrical stimulation during the absolute refractory period of the myocardium improves severe heart failure.

AIM: In experimental studies, nonexcitatory electrical stimulation delivered at the time of absolute myocardial refractoriness resulted in cardiac contractility modulation (CCM) with improved systolic function. This study reports the initial experience with CCM in patients with chronic heart failure. METHODS AND RESULTS: Twenty-five patients, 23 males, with a mean age of 62+/-9 years and drug-refractory NYHA class III heart failure were assigned to CCM-generator implantation. The underlying heart disease was idiopathic dilated cardiomyopathy in 12 patients and coronary heart disease in 13 patients. Acute efficacy of CCM with 7.73-V stimuli delivered via two right ventricular leads was evaluated by measuring the time derivative of left ventricular pressure (dP/dt). After implantation, the CCM generator was activated for 3 h daily over 8 weeks. In 23/25 patients the CCM system was implanted successfully. Heart failure significantly improved from NYHA class III to class II in 15 patients and to class I in 4 patients (p < 0.000001), left ventricular ejection fraction improved from 22+/-7% to 28+/-8% (p = 0.0002), and the Minnesota Living with Heart Failure Score improved from 43+/-22 to 25+/-18 (p = 0.001). The 6-min walk test increased from 411+/-86 to 465+/-81 m (p= 0.02). Nine patients (39%) had intermittent sensations associated with CCM delivery. There were two (8%) non-device-related deaths during follow-up. CONCLUSIONS: These preliminary data indicate that CCM by delivery of intermittent nonexcitatory electrical stimuli is a promising technique for improving ventricular systolic function and symptoms in patients with drug-refractory NYHA class III heart failure.

Cardiomyopathy, Dilated↗

T wave alternans does not assess arrhythmic risk in patients with Brugada syndrome.

BACKGROUND: Brugada syndrome is associated with a risk for sudden death, but the arrhythmic risk in an individual Brugada syndrome patient is difficult to predict. Pathologic changes in the early repolarization phase of the ventricular action potential probably constitute part of the arrhythmogenic substrate in Brugada syndrome. Microvolt T wave alternans (TWA) assesses dynamic beat-to-beat changes in repolarization and has been suggested as a marker for repolarization-related sudden death. We therefore tested whether TWA is an indicator for arrhythmias in Brugada syndrome with a focus on right precordial ECG leads. METHODS: We assessed TWA in nine symptomatic, inducible patients with established Brugada syndrome and in seven healthy controls. TWA was assessed at rest and during exercise using both standard methods and an algorithm that assesses TWA in the early ST segment and the right precordial leads. RESULTS: None of the Brugada patients developed TWA in this study irrespective of analysis at rest or during exercise, neither using standard methods nor when the early ST segment was included in the analysis. When the early ST segment was included in the analysis, nonsustained TWA was found in three out of seven, and sustained TWA in one control. CONCLUSION: T wave alternans is not an appropriate test to detect arrhythmic risk in patients with Brugada syndrome.

Adult↗