Clinical efficacy of cardiac resynchronization therapy using left ventricular pacing in heart failure patients stratified by severity of ventricular conduction delay.

OBJECTIVES: We assessed the clinical efficacy of single-site left ventricular (LV) pacing and determined the impact of baseline conduction delay severity on the magnitude of benefit. BACKGROUND: Multisite biventricular pacing can improve heart failure (HF) symptoms in patients with an intraventricular conduction delay by resynchronizing abnormal ventricular contractions and improving LV systolic function. METHODS: Eighty-six patients with at least New York Heart Association functional class II HF, chronic LV systolic dysfunction, normal sinus rhythm, and a QRS interval over 120 ms were implanted for atrial-synchronized LV pacing. The single-blinded, randomized, controlled, crossover study stratified patients 1:1 by the baseline QRS interval into long (QRS >150 ms) and short (QRS 120 to 150 ms) groups, which were compared during a three-month period of active (univentricular) pacing and a three-month period of inactive (ventricular inhibited) pacing. The primary end point was peak oxygen consumption (VO(2)) followed by anaerobic threshold, distance walked in 6 min, and quality-of-life questionnaire score. PATIENTS: Twelve patients were withdrawn before randomization and 17 could not complete both study periods. The short QRS group did not improve in any end point with active pacing. For the long QRS group, peak VO(2) increased 2.46 ml/min/kg (p < 0.001), the anaerobic threshold increased 1.55 ml/min/kg (p < 0.001), the distance walked in 6 min increased 47 m (p = 0.024), and the quality-of-life score improved 8.1 points (p = 0.004). CONCLUSIONS: Left ventricular pacing significantly improves exercise tolerance and quality of life in patients with chronic HF, LV systolic dysfunction, and a QRS interval over 150 ms.

Adolescent↗

The impact of the pro- and anti-inflammatory immune response on ventilation time after cardiac surgery.

BACKGROUND: Cardiac surgery using cardiopulmonary bypass (CPB) may induce a systemic inflammatory response syndrome (SIRS), which is associated with an increased risk of postoperative morbidity and mortality. The intention of this pilot study was to investigate the influence of the pro- and anti-inflammatory cytokine responses as well as of released adhesion molecules and endotoxin on the time requirements for assisted postoperative respiration following CPB surgery. METHODS: One hundred consecutive patients undergoing elective coronary artery bypass grafting (CABG) using CPB were prospectively investigated. Blood levels of cytokines, adhesion molecules, and endotoxins were serially measured at four time points perioperatively. RESULTS: All patients survived the observation period. Eighty-five patients were uneventful (group 1), whereas 15 patients required prolonged ventilation (34.8 +/- 9.2 h; group 2). All patients developed a pro-inflammatory and a compensatory anti-inflammatory cytokine response. An endotoxin liberation was found in parallel. The prediction of prolonged respirator dependence may be possible at completion of surgery using a combined data pattern analysis, including interleukin (IL)-6, IL-8, IL-4, endotoxins, vascular cell adhesion molecule (VCAM)-1, age, and cross clamp (x-clamp) time. Using arbitrary cutoff points improved sensitivity (0.92), specificity (0.90), positive prediction (0.87), and negative prediction (0.85) (all P < 0.02), and the ODD ratio (2.1) was found. CONCLUSIONS: Cardiac surgery and CPB induces both a pro- and anti-inflammatory immune response. The use of a data pattern instead of several individual parameters seems advantageous for individualized predictions on postoperative recovery in CPB surgery.

Aged↗

Evaluation of a dual chamber implantable cardioverter defibrillator for the treatment of atrial and ventricular arrhythmias.

Eighty-nine patients with a documented history of atrial tachyarrhythmias or fibrillation (AF) received a cardioverter defibrillator designed to selectively differentiate and treat atrial and ventricular arrhythmias. Twenty-two patients received a coronary sinus lead and, therefore, could use a separate shock vector for selective treatment of atrial tachyarrhythmias/AF. The device is designed to treat tachyarrhythmias with antitachycardia pacing (ATP) and/or shock therapy using an atrial and/or a ventricular shock vector. Patients underwent induction and shock termination of atrial or dual tachyarrhythmias (AF/VF) to verify proper device function and to measure the arrhythmia detection time with enhancements and preventive algorithms programmed On and Off, respectively. Detection time for 329 VF inductions was 2.41 +/- 0.64 seconds with enhancements On and 2.29 +/- 0.47 with enhancements Off (NS). At implant or predischarge, 283 AF and/or AF/VF (121 atrial and 162 atrial/ventricular fibrillation) were induced. Shock conversion efficacy was 89.8% with AF conversion energies ranging from 0.9 to 27 J. Thirteen of the 23 patients had atrial shock conversions using the separate shock vector with an average conversion energy of 1.9 +/- 1.4 J. (range 0.5-5 J). During follow-up the efficacy of ATP on atrial tachyarrhythmias was 59% and the efficacy of delivered shocks on AF was 85%. This new dual chamber cardioverter defibrillator appropriately detected and classified atrial arrhythmias, and shock therapy for AF was highly effective. The detection algorithm differentiated atrial tachyarrhythmia/AF and did not delay VF detection. The separate shock vector converted induced AF with energies ranging from 0.6 to 5 J.

Atrial Fibrillation↗

ICD leads: design and chronic dysfunctions.

The treatment of ventricular tachyarrhythmias has changed over the last 10 years. Implantable cardioverter defibrillators (ICDs), once used only as a last resort therapy, have now become the treatment of choice. This change occurred before the first results of randomized studies on ICD therapy in patients with life-threatening ventricular tachyarrhythmias were published by the end of 1997. Technological advances of ICD therapy, in particular the development of transvenous leads, were to a large extent responsible for this change. Modern leads are characterized by their multilumen design that incorporates straight wires and coiled conductors into a single electrode body. Conductors and insulation are sheathed with additional insulation layers. The most frequently used insulating materials are silicone, polyurethane, and fluoropolymers. Lead failures are an important complication of ICD therapy. Fractured conductors, compression, creeping, or insulation defects from abrasion can cause such lead dysfunctions. Chronically implanted leads will inevitably have an increased risk of failure due to defects despite all technological advances. In the light of improving survival figures in patients with ventricular tachyarrhythmias and increasing numbers of ICD implantations, lead failures are becoming a clinical problem of ever increasing importance. Therefore, the question of which lead types necessitate extraction when a certain failure occurs and which leads can be left in place. Despite continuous improvements in lead extraction systems and growing experience in their use, the extraction of any pacemaker or ICD lead is associated with some risk of complications.

Defibrillators, Implantable↗

Anterior-posterior versus anterior-lateral electrode positions for external cardioversion of atrial fibrillation: a randomised trial.

BACKGROUND: External cardioversion is a readily available treatment for persistent atrial fibrillation. Although anatomical and electrophysiological considerations suggest that an anterior-posterior electrode position should create a more homogeneous shock-field gradient throughout the atria than an anterior-lateral position, both electrode positions are equally recommended for external cardioversion in current guidelines. We undertook a randomised trial comparing the two positions with the endpoint of successful cardioversion. METHODS: 108 consecutive patients (mean age 60 years [SD 16]) with persistent atrial fibrillation (median duration 5 months, range 0.1-120) underwent elective external cardioversion by a standardised step-up protocol with increasing shock strengths (50-360 J). Electrode positions were randomly assigned as anterior-lateral or anterior-posterior. If sinus rhythm was not achieved with 360 J energy, a single cross-over shock (360 J) was applied with the other electrode configuration. A planned interim analysis was done after these patients had been recruited; it was by intention to treat. FINDINGS: Cardioversion was successful in a higher proportion of the anterior-posterior than the anterior-lateral group (50 of 52 [96%] vs 44 of 56 [78%], difference 23.7% (95% CI 9.1-37.8, p=0.009). Cross-over from the anterior-lateral to the anterior-posterior electrode position was successful in eight of 12 patients, whereas cross-over in the other direction was not successful (two patients). After cross-over, cardioversion was successful in 102 of 108 randomised patients (94%). INTERPRETATION: An anterior-posterior electrode position is more effective than the anterior-lateral position for external cardioversion of persistent atrial fibrillation. These results should be considered in clinical practice, for the design of defibrillation electrode pads, and when guidelines for cardioversion of atrial fibrillation are updated.

Adolescent↗

Treatment of thrombus formation associated with the MicroMed DeBakey VAD using recombinant tissue plasminogen activator.

BACKGROUND: The latest generation of left ventricular assist devices consists of nonpulsatile impeller pumps. In these small pumps, thrombus formation inside the device does not lead to thromboembolic end-organ dysfunction but may dramatically impair pump flow. We report on our experience with thrombus-related pump dysfunctions of the MicroMed DeBakey left ventricular assist device and its treatment. METHODS: Eight of 22 patients with a MicroMed DeBakey VAD presented with a critically reduced pump flow. In 7 cases, an increased power demand indicative of progressive thrombus formation associated with the device was evident, whereas 1 case presented with thrombus formation within the inflow conduit associated with a very low power demand. Brief spontaneously resolving pump stops had been noted in 6 patients. All 8 patients were treated with 100 mg of recombinant tissue plasminogen activator (rt-PA), administered via an IV line. RESULTS: Rt-PA lysis led to an increase of pump flow along with a reduction of power demand within a short time in all patients. No severe bleeding complications occurred. However, 4 patients experienced transient epistaxis. All patients could be discharged from intensive care immediately after discontinuation of thrombolytic therapy. CONCLUSION: Rt-PA lysis is a very effective tool for thrombus-related pump dysfunction in patients with impeller pumps, which renders emergency surgical exchange unnecessary in most cases.

Adolescent↗

Long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay.

OBJECTIVES: We sought to compare the short- and long-term clinical effects of atrial synchronous pre-excitation of one (univentricular) or both ventricles (biventricular), that provide cardiac resynchronization therapy (CRT). BACKGROUND: In patients with heart failure (HF) who have a ventricular conduction delay, CRT improves systolic hemodynamic function. The clinical benefit of CRT is still being investigated. METHODS: Forty-one patients were randomized to four weeks of first treatment with biventricular or univentricular stimulation, followed by four weeks without treatment, and then four weeks of a second treatment with the opposite stimulation. The best CRT stimulation was continued for nine months. Cardiac resynchronization therapy was optimized by hemodynamic testing at implantation. The primary end points were exercise capacity measures. Data were analyzed by two-way repeated-measures analysis of variance. RESULTS: The left ventricle was selected for univentricular pacing in 36 patients. The clinical effects of univentricular and biventricular CRT were not significantly different. The results of each method were pooled to assess sequential treatment effects. Oxygen uptake during bicycle exercise increased from 9.48 to 10.4 ml/kg/min at the anaerobic threshold (p = 0.03) and from 12.5 to 14.3 ml/kg/min at peak exercise (p < 0.001) with the first treatment, and from 10.0 to 10.7 ml/kg/min at the anaerobic threshold (p = 0.2) and from 13.4 to 15.2 ml/kg/min at peak exercise (p = 0.002) with the second treatment. The 6-min walk distance increased from 342 m at baseline to 386 m after the first treatment (p < 0.001) and to 416 m after the second treatment (p = 0.03). All improvements persisted after 12 months of therapy. CONCLUSIONS: Cardiac resynchronization therapy produces a long-term improvement in the clinical symptoms of patients with HF who have a ventricular conduction delay. The differences between optimized biventricular and univentricular therapy appear to be small for short-term treatment.

Arrhythmias, Cardiac↗

Therapeutic options and heart failure survival score predictability in an academic heart failure center: an analysis of 120 consecutive patients during a 1-year period.

BACKGROUND: the incidence and prevalence of patients with advanced heart failure is increasing worldwide and the number of cardiac transplantations remains limited. AIMS: it was the aim of the study to describe our experience with the increasing number of available medical, interventional and cardiac surgery options, and to assess heart failure survival score predictability in an academic heart failure center within a 1-year follow-up. METHODS AND RESULTS: in all patients who were referred for cardiac transplant evaluation within a 12-month period between April 1998 and March 1999 at our Interdisciplinary Heart Failure and Transplant Program, our team assessed all medical interventions as well as interventional and surgical treatment options that were available, based on the clinical profile on initial presentation. In 92% of the 120 patients referred for cardiac transplantation evaluation, drug therapy could be optimized. A considerable number of patients could be subjected to an organ-preserving intervention or surgery, either PTCA (n=11), CABG (n=4), valve repair (n=7), multisite pacing (n=7), or partial ventricular resection (n=5). Only a small group of patients with the worst heart failure survival score were listed for heart transplantation (n=17) or received a ventricular assist device (n=3). CONCLUSIONS: within a contemporary cohort of advanced heart failure patients, only a small number of patients will undergo cardiac transplantation, which is predictable by the heart failure survival score. Most patients will undergo optimized medical therapy and a considerable number will be subjected to interventional or surgical treatment options.

Adrenergic beta-Antagonists↗

Effect of ventricular fibrillation duration on the defibrillation threshold in humans.

Early during ventricular fibrillation, the defibrillation threshold may be low, as ventricular fibrillation most probably arises from a localized area with only a few wavefronts and the effects of global ischemia, ventricular dilatation, and sympathetic discharge have not yet fully developed. The purpose of this study was to explore the effect of the timing of shock delivery in humans. During implantation of an ICD in 26 patients (24 men, 60 +/- 11 years, 19 coronary artery disease, NYHA 2.2 +/- 0.4, left ventricular ejection fraction 0.42 +/- 0.16), the defibrillation threshold was determined after approximately 10 and 2 seconds of ventricular fibrillation. Ventricular fibrillation was induced by T wave shocks. Mean defibrillation threshold was 9.9 +/- 3.6 J after 10.3 +/- 1.0 seconds. Within 2 seconds, 20 of 26 patients could be successfully defibrillated with < or = 8 J. In these patients, the mean defibrillation threshold was 4.0 +/- 2.1 J after 1.4 +/- 0.3 seconds compared to 9.5 +/- 3.1 J after 10.2 +/- 1.1 seconds (P < 0.001). There were no clinical differences between patients who could be successfully defibrillated within 2 seconds and those patients without successful defibrillation within 2 seconds. In the majority of patients, the defibrillation threshold was significantly lower within the first few cycles of ventricular fibrillation than after 10 seconds of ventricular fibrillation. These results should lead to exploration of earlier shock delivery in implantable devices. This could possibly reduce the incidence of syncope in patients with rapid ventricular tachyarrhythmias and ICDs.

Chi-Square Distribution↗

European clinical experience with a dual chamber single pass sensing and pacing defibrillation lead.

Dual chamber ICDs are increasingly implanted nowadays, mainly to improve discrimination between supraventricular and ventricular arrhythmias but also to maintain AV synchrony in patients with bradycardia. The aim of this study was to investigate a new single pass right ventricular defibrillation lead capable of true bipolar sensing and pacing in the right atrium and integrated bipolar sensing and pacing in the right ventricle. The performance of the lead was evaluated in 57 patients (age 61 +/- 12 years; New York Heart Association 1.9 +/- 0.6, left ventricular ejection fraction 0.38 +/- 0.15) at implant, at prehospital discharge, and during a 1-year follow-up. Sensing and pacing behavior of the lead was evaluated in six different body positions. In four patients, no stable position of the atrial electrode could intraoperatively be found. The intraoperative atrial sensing was 2.3 +/- 1.6 mV and the atrial pacing threshold 0.8 +/- 0.5 V at 0.5 ms. At follow-up, the atrial sensing ranged from 1.5 mV to 2.2 mV and the atrial pacing threshold product from 0.8 to 1.7 V/ms. In 11 patients, an intermittent atrial sensing problem and in 24 patients an atrial pacing dysfunction were observed in at least one body position. In 565 episodes, a sensitivity of 100% and a specificity of 96.5% were found for ventricular arrhythmias. In conclusion, this single pass defibrillation lead performed well as a VDD lead and for dual chamber arrhythmia discrimination. However, loss of atrial capture in 45% of patients preclude its use in patients depending on atrial pacing.

Aged↗