PubMed Health⌕ Search

Biomedical subjects

Donald S Baim

Publications and source records attributed to Donald S Baim.

At least 19 recordsLinked to original sources

Effectiveness of same day percutaneous coronary intervention followed by minimally invasive aortic valve replacement for aortic stenosis and moderate coronary disease ("hybrid approach").

In 2005, the investigators described a "hybrid" cardiovascular interventional strategy combining percutaneous coronary intervention (PCI) for coronary artery disease (CAD) followed by valve surgery for patients with urgent complex CAD and valve disease to reduce morbidity and mortality. This hybrid approach has been extended prospectively in elderly, high-risk patients with aortic stenosis scheduled for elective minimally invasive aortic valve replacement (MI-AVR) who, on preoperative coronary angiography, were found to have moderate CAD amenable to PCI. In this prospective, observational series, 18 patients (mean age 76 years) underwent elective hybrid MI-AVR with PCI from May 2003 to February 2006. Five patients had undergone previous coronary artery bypass grafting. Patients underwent coronary angiography the day of (n = 12) or evening before (n = 6) MI-AVR, and after identifying moderately severe CAD, all 18 underwent the implantation of drug-eluting stents to the affected coronary arteries, followed by MI-AVR. Although all patients received standard doses of antiplatelet medications, including acetylsalicylic acid (325 mg before PCI and 325 mg/day thereafter) and clopidogrel (300 mg after PCI, 75 mg/day thereafter for 90 days for the Cypher stent), there were no reoperations for bleeding; only 8 of 18 patients required postoperative blood transfusions. One patient died postoperatively from a colonic perforation, and there were no late mortalities after a mean follow-up of 19 months. In conclusion, this hybrid strategy has low morbidity and mortality and may be a new therapeutic option for older, high-risk patients with combined CAD and aortic valve disease.

Aged↗

Effect of diabetes mellitus on five-year clinical outcomes after single-vessel coronary stenting (a pooled analysis of coronary stent clinical trials).

Diabetes mellitus (DM) increases the risk of clinically driven, repeat revascularization of the stented lesion in the first year after coronary stenting. The effect of DM on the risk of repeat revascularization of the stented lesion beyond 1 year, revascularization at other coronary sites, and clinical outcomes of cardiac death and myocardial infarction (MI) has not been reported. We pooled primary data from 4 multicenter trials of second-generation coronary stents that included 1,228 patients, 263 of whom (21%) had DM. Patients were followed annually to assess for prespecified end points, including repeat revascularization procedures, death, or MI. Repeat revascularization of the stented lesion was performed more frequently during the first year in patients with DM (16.0% vs 10.9%, p = 0.01) but decreased to a low frequency (1.8% vs 1.3% per year) thereafter in patients with and without DM. Repeat revascularization of other coronary segments was more frequent in patients with DM during the first and subsequent years (5-year rates, 32.2% vs 24.1%, p = 0.005). Cardiac death or MI was also more frequent among patients with DM (5-year rates, 25.4% vs 17.9%, p = 0.008) and remained significant after adjustment for all differences in baseline characteristics (hazard ratio 1.5, 95% confidence interval 1.1 to 2.0, p = 0.01). In conclusion, diabetic patients are at increased risk for revascularization of the stented lesion only in the first year after single-lesion stenting but are at increased risk for other clinical events, including cardiac death and MI, over the next 4 years.

Aged↗

Differential effects between intravenous and targeted renal delivery of fenoldopam on renal function and blood pressure in patients undergoing cardiac catheterization.

A randomized, controlled clinical trial demonstrated that intravenous (IV) fenoldopam did not prevent further deterioration in renal function after contrast administration in patients with chronic renal insufficiency. This lack of effect may have been a consequence of the inability to administer an effective renal dose of IV fenoldopam. This study sought to determine whether compared with IV administration, selective intrarenal (IR) fenoldopam would increase local concentration, leading to a higher glomerular filtration rate (GFR), and, because of first-pass renal elimination, result in lower systemic drug levels and less decrease in systemic blood pressure (BP). A randomized, controlled, open-label, partial crossover design trial was conducted in which 33 patients who underwent coronary angiography were randomized in a 1:2 ratio to control or fenoldopam (initially IV, then crossed over to IR through a bifurcated renal infusion catheter). Compared with IV fenoldopam, IR administration was associated with a significantly higher GFR (73.7 +/- 3.1 vs 62.6 +/- 2.5 ml/min, p = 0.0007) and renal plasma flow (537.2 +/- 34.0 vs 494.0 +/- 35.5 ml/min, p <0.01), lower fenoldopam plasma levels (3.3 +/- 0.3 vs 4.8 +/- 0.3 ng/ml, p <0.0001), and greater nadir systolic BP (125.5 +/- 3.6 vs 117.4 +/- 2.8 mm Hg, p <0.0001). Two hours after drug discontinuation after contrast administration, GFRs in the patients who received IR fenoldopam remained higher than in controls (+15.0 ml/min [+25%] vs -8.0 ml/min [-14.0%], p <0.05). In conclusion, this pilot trial demonstrates that the IR infusion of fenoldopam is safe and practical, producing greater renal effect and less reduction of BP than IV infusion. It would be appropriate to restudy this renal vasodilator for the prevention of contrast nephropathy, using selective IR delivery.

Aged↗

Approaches to mechanical coronary thrombectomy.

Coronary thrombi are an integral part of acute coronary syndromes. Since the introduction of the AngioJet Rheolytic thrombectomy device in 1999, mechanical thrombectomy has replaced intracoronary thrombolysis during catheter-based procedures. Other approaches include simple suction aspiration, cut and aspirate devices and clot disruption by ultrasound or laser-induced cavitation. These device classes differ in the completeness of thrombus removal, ease of use, complication profile, as well as clinical evidence of benefit. The current approaches to mechanical thrombectomy are reviewed from these perspectives.

Cardiac Catheterization↗

A blinded, randomized, placebo-controlled trial of percutaneous laser myocardial revascularization to improve angina symptoms in patients with severe coronary disease.

OBJECTIVES: This study was a randomized, patient- and evaluator-blinded, placebo-controlled trial in patients treated using percutaneous myocardial laser revascularization. BACKGROUND: Previous studies using similar therapies have been confounded by placebo bias. METHODS: A total of 298 patients with severe angina were randomly assigned to receive low-dose or high-dose myocardial laser channels or no laser channels, blinded as a sham procedure. The primary end point was the change in exercise duration from baseline examination to six months. RESULTS: The incidence of 30-day death, stroke, myocardial infarction, coronary revascularization, or left ventricular perforation occurred in two patients in the placebo, eight patients in the low-dose, and four patients in the high-dose groups (p = 0.12); 30-day myocardial infarction incidence was higher in patients receiving either low-dose or high-dose laser (nine patients) compared with placebo (no patients, p = 0.03). At six months, there were no differences in the change in exercise duration between those receiving a sham (28.0 s, n = 100), low-dose laser (33.2 s, n = 98), or high-dose laser (28.0 s, n = 98, p = 0.94) procedure. There were also no differences in the proportion of patients improving to better than Canadian Cardiovascular Society class III angina symptoms at six months. The follow-up visual summed stress single-photon-emission computed tomography scores were not significantly different from baseline in any group and were no different between groups. The modest improvement in angina symptoms assessed by the Seattle Angina Questionnaire also was not statistically different among the arms. CONCLUSIONS: Treatment with percutaneous myocardial laser revascularization provides no benefit beyond that of a similar sham procedure in patients blinded to their treatment status.

Angina Pectoris↗

Transendocardial and transepicardial intramyocardial fibroblast growth factor-2 administration: myocardial and tissue distribution.

Effective local delivery to the heart remains an obstacle to successful therapeutic application of a number of drugs and biological agents. This study was designed to study and optimize the delivery characteristics of transendocardial intramyocardial (IM) administration, determine myocardial deposition and retention over time, and compare it to transepicardial IM injection. Thirty-nine pigs were used for the study (15 for catheter optimization, 15 for transendocardial IM delivery, and 9 for transepicardial IM delivery). (125)I-Fibroblast growth factor-2 (FGF2) (25 microCi) was used as the prototype molecule. Tissue and myocardial distribution was determined at 1 and 24 h and 7 days. Using 1-h (125)I-FGF2 myocardial deposition as a parameter for delivery efficiency, the optimal needle length and delivery volume for transendocardial based delivery were determined to be 6 mm and 0.1 ml, respectively. Using these parameters for endocardial delivery, (125)I-FGF2 cardiac activity was 18.01 +/- 3.84% of delivered activity at 1 h, 11.65 +/- 5.17% at 24 h, and 2.32 +/- 0.87% at 7 days in ischemic animals. Studies in nonischemic animals produced similar results. For transepicardial delivery, (125)I-FGF2 cardiac-specific activity was 23.14 +/- 12.67% for the 6-mm needle, declining to 12.32 +/- 8.50% at 24 h, and did not significantly differ from values obtained following transendocardial delivery. Thus, optimized transendocardial intramyocardial delivery using Biosense guidance results in efficient delivery of FGF2 to the target myocardium that is comparable with transepicardial delivery, both providing markedly higher myocardial deposition and retention and lower systemic recirculation of FGF2 than intracoronary, intrapericardial, or intravenous delivery. However, myocardial distribution is limited to injection sites.

Animals↗

Determinants of 30-day adverse events following saphenous vein graft intervention with and without a distal occlusion embolic protection device.

Distal balloon occlusion was approved as a means of embolic protection during saphenous vein graft intervention based on its ability to decrease major adverse clinical events (MACEs) by 42% in the 801-patient Saphenous Vein Graft Angioplasty Free of Emboli Randomized (SAFER) trial. However, the cost and technical complexity of this device have limited its widespread use and prompted some to avoid its use in cases that appear at "low risk" for complications. If predictors of MACEs and their potential decrease by distal balloon occlusion could be identified, this would have important clinical implications in this challenging population. We therefore used standard demographic and angiographic variables and 2 new angiographic markers (extent of graft degeneration and estimated volume of plaque in the target lesion) to construct multivariable logistic regression models of 30-day of MACEs in the SAFER trial. Independent correlates of increased 30-day MACEs were more extensive vein graft degeneration (p = 0.0001) and bulkier lesions (larger estimated plaque volume, p = 0.0005). Use of a distal balloon occlusion device was independently predictive of lower 30-day rates of MACE (p = 0.01), with uniform benefit across risk strata (no significant interaction between device use and independent angiographic risk factors). Thus, the risk of 30-day MACEs after percutaneous intervention in aortocoronary saphenous vein grafts is increased in more diffusely diseased grafts and in bulkier lesions, but a significant benefit of the GuardWire was seen across all levels of MACE risk rather than just those perceived to be at highest risk.

Aged↗

Effect of gender on in-hospital and one-year outcomes after contemporary coronary artery stenting.

Despite the similar extent of epicardial coronary artery disease and procedural success, women have been noted to have a twofold higher incidence of in-hospital mortality and vascular complications than men undergoing coronary artery stenting. This analysis of 1,908 women from a pooled data set of 6,186 patients is the largest reported series of prospectively collected data from the contemporary stent era. This study demonstrates that stenting can be performed in women with excellent acute results with no age-independent increase in short- or long-term mortality compared with men, although with a significantly higher risk of vascular complications.

Aged↗

Cost-effectiveness of distal embolic protection for patients undergoing percutaneous intervention of saphenous vein bypass grafts: results from the SAFER trial.

OBJECTIVES: The goal of this research was to determine the incremental cost and cost-effectiveness of embolic protection in patients undergoing percutaneous revascularization (PCI) of diseased saphenous vein bypass grafts (SVGs). BACKGROUND: Distal protection using the GuardWire balloon occlusion device has been shown to reduce major ischemic complications in patients undergoing SVG PCI, but the cost-effectiveness of this approach is unknown. METHODS: We prospectively measured medical resource utilization and cost for 801 patients undergoing SVG intervention who were randomized to distal protection using the GuardWire (n = 406) or conventional treatment (n = 395) in the Saphenous Vein Graft Angioplasty Free of Emboli Randomized (SAFER) trial. Long-term survival and cost-effectiveness were projected based on observed 30-day outcomes and a validated survival model for postcoronary artery bypass graft patients. RESULTS: Compared with conventional treatment, distal protection increased initial procedural costs by approximately $1,600 ($6,326 vs. $4,779, p < 0.001). However, by reducing ischemic complications, distal protection reduced mean length of stay by 0.4 days and other hospital costs by nearly $1,000 ($6,846 vs. $7,811, p = 0.018). As a result, overall initial hospital costs were only $582 per patient higher with distal protection. Based on the observed 30-day cost and outcome differences in the trial, the incremental cost-effectiveness ratio for distal protection was $3,718 per year of life saved and remained <$40,000 per year of life saved in 97.3% of bootstrap simulations (95% confidence interval, $0 to $43,079). CONCLUSIONS: For patients undergoing PCI of diseased SVGs, distal protection using the GuardWire system is an attractive use of limited health care resources.

Aged↗

Utility of the Safe-Cross-guided radiofrequency total occlusion crossing system in chronic coronary total occlusions (results from the Guided Radio Frequency Energy Ablation of Total Occlusions Registry Study).

The Safe-Cross radiofrequency guidewire (IntraLuminal Therapeutics, Carlsbad, California) combines 3 capabilities: (1) steerability of a conventional 0.014-in intermediate-stiffness guidewire, (2) optical coherence reflectometry to warn the operator when the wire tip approaches within 1 mm of the vessel wall, and (3) delivery of radiofrequency energy pulses to the wire tip to facilitate passage through an occluded segment. The Guided Radio Frequency Energy Ablation of Total Occlusions Registry was a prospective, nonrandomized, multicenter registry that enrolled 116 patients who had long-term coronary total occlusions and in whom a >10-minute good-faith attempt to cross the occlusion using conventional guidewires had failed. The median known duration of occlusion was 22 months (32%; >1 year), and the median length of the occluded segment was 25 mm (25%; >30 mm). Device success was achieved in 63 of 116 of patients (54.3%), and major adverse events occurred in 6.9%, consisting predominantly of isolated increases in cardiac enzymes with no procedure-related deaths, Q-wave myocardial infarctions, or emergency bypass operations. Clinical perforation occurred in 2.6% of patients; of these, perforation in only 1 patient (0.9%) was adjudicated to be directly related to the Safe-Cross radiofrequency wire rather than to the stiff and/or hydrophilic wires used after an inability to advance with the Safe-Cross. Based on these data, the device has been approved in Europe and was recently (January 2004) granted 510K clearance by the Food and Drug Administration.

Adult↗