PubMed Health⌕ Search

Biomedical subjects

Donald S Baim

Publications and source records attributed to Donald S Baim.

At least 37 records · Page 2Linked to original sources

Differential mortality risk of postprocedural creatine kinase-MB elevation following successful versus unsuccessful stent procedures.

OBJECTIVES: This study was designed to evaluate the effect of periprocedural myocardial infarction (MI) on mortality according to success of the stent procedure. BACKGROUND: The mortality effect of periprocedural MI relative to successful versus unsuccessful procedures has not been examined. METHODS: All-cause mortality during the first year was evaluated prospectively among 5,850 patients from coronary stent clinical trials. Myocardial infarction was classified according to creatine kinase-MB level as type 1 (>1 but <3 times normal), type 2 (>or=3 but 8 times normal or Q-wave MI). Procedures were classified as successful unless there was a final diameter stenosis >50%; final Thrombolysis In Myocardial Infarction flow grade <3; final National Heart, Lung, and Blood Institute dissection grade >or=D; repeat revascularization within 24 h; or stent thrombosis within 24 h. RESULTS: Myocardial infarction was more frequent after unsuccessful procedures (69.6% vs. 20.4%, p < 0.001). Mortality during the first year was higher in patients with MI (2.8% vs. 1.7%, p = 0.01), but the effect was significant only for type 3 MI (4.7% vs. 1.7%, p = 0.008). Moreover, the mortality difference for any MI was confined to patients with unsuccessful procedures (13.1% vs. 0%, p = 0.03), with no significant effect among patients with otherwise successful procedures (2.1% vs. 1.7%, p > 0.20). The independent predictors of mortality were unsuccessful procedure (p < 0.001), diabetes mellitus (p = 0.001), history of prior MI (p = 0.003), multivessel disease (p = 0.006), and advancing age (p < 0.001), but not periprocedural MI. CONCLUSIONS: The association of periprocedural MI with increased mortality during the first year following stent placement was confined to patients with unsuccessful procedures.

Aged↗

Beyond restenosis: five-year clinical outcomes from second-generation coronary stent trials.

BACKGROUND: In the first year after coronary stent implantation, clinical failures are driven mainly by procedural complications and restenosis, but the subsequent relative contributions of restenosis and disease progression to late failures are less clear. METHODS AND RESULTS: We observed 1228 patients for 5 years after the implantation of stents as part of pivotal second-generation coronary stent trials. Clinical events of death, myocardial infarction, repeat revascularization, and repeat hospitalization for acute coronary syndrome or congestive heart failure were attributed to the index stented (target) lesion or other distinct sites (either in the target or other coronary vessels) and further classified as procedural, restenosis, or nonrestenosis. During the first year the hazard rate was 18.3% for target-lesion events and 12.4% for events unrelated to the target lesion. After the first year the average annual hazard rate was 1.7% for target-lesion events and 6.3% for nontarget-lesion events. By the fifth year, restenosis events occurred in 20.3% of patients, whereas 30-day procedural complications or later nonrestenosis events occurred in 37.9%, including 11.4% who also experienced a restenosis event, for a combined cumulative event rate of 46.4%. Diabetes mellitus and multivessel disease were independently associated with increased risk for both restenosis and nonrestenosis events. CONCLUSIONS: In a low-risk clinical trial population, the clinical outcome beyond 1 year after stenting is determined by a high rate of events related to disease progression in segments other than the stented lesion, which itself remains relatively stable.

Aged↗

Effects of stent length and lesion length on coronary restenosis.

The choice of drug-eluting versus bare metal stents is based on costs and expectations of restenosis and thrombosis risk. Approaches to stent placement vary from covering just the zone of maximal obstruction to stenting well beyond the lesion boundaries (normal-to-normal vessel). The independent effects of stented lesion length, nonstented lesion length, and excess stent length, on coronary restenosis have not been evaluated for bare metal or drug-eluting stents. We analyzed the angiographic follow-up cohort (1,181 patients) from 6 recent bare metal stent trials of de novo lesions in native coronary arteries. Stent length exceeded lesion length in 87% of lesions (mean lesion length 12.4 +/- 6.3 mm, mean stent length 20.0 +/- 7.9 mm, mean difference 7.6 +/- 7.9 mm). At 6- to 9-month follow-up, the mean percent diameter stenosis was 39.1 +/- 20.1%. In an adjusted multivariable model of percent diameter stenosis, each 10 mm of stented lesion length was associated with an absolute increase in percent diameter stenosis of 7.7% (p <0.0001), whereas each 10 mm of excess stent length independently increased percent diameter stenosis by 4.0% (p <0.0001) and increased target lesion revascularization at 9 months (odds ratio 1.12, 95% confidence interval 1.02 to 1.24). Significant nonstented lesion length was uncommon (12.5% of cases). In summary, stent length exceeded lesion length in most stented lesions, and the amount of excess stent length increased the risk of restenosis independent of the stented lesion length. This analysis supports a conservative approach of matching stent length to lesion length to reduce the risk of restenosis with bare metal stents.

Clinical Trials as Topic↗

Impact of sirolimus-eluting stents on outcome in diabetic patients: a SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) substudy.

BACKGROUND: Randomized clinical trials have shown that a sirolimus-eluting stent significantly reduces restenosis after percutaneous coronary revascularization. Diabetic patients are known to have a higher risk of restenosis compared with nondiabetic patients. The purpose of this analysis was to determine the impact of sirolimus-eluting stents on outcomes of diabetic compared with nondiabetic patients. METHODS AND RESULTS: The SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) trial is a randomized, double-blind study that compared sirolimus-eluting and bare metal stent implantation in 1058 patients with de novo native coronary artery lesions. Diabetes mellitus was present in 279 (26%) patients (diabetes mellitus group, 131 patients received sirolimus-eluting stents and 148 patients received bare metal stents) and was absent in 778 patients (no-diabetes mellitus group, 402 patients received sirolimus-eluting stents and 376 patients received bare metal stents). At 270 days, target lesion revascularization was reduced in diabetic patients from 22.3% with bare metal stents to 6.9% with sirolimus-eluting stents (P<0.001) and in nondiabetic patients from 14.1% to 2.99% (P<0.001), respectively. Major adverse cardiac events were reduced in diabetic patients from 25% with bare metal stents to 9.2% with sirolimus-eluting stents (P<0.001) and from 16.5% to 6.5% (P<0.001) in nondiabetic patients, respectively. CONCLUSIONS: Implantation of sirolimus-eluting stents compared with bare metal stents in de novo coronary lesions reduces major adverse cardiac events in patients with and without diabetes mellitus. However, among patients receiving sirolimus-eluting stents, there remains a trend toward a higher frequency of repeat intervention in diabetic patients compared with nondiabetic patients, particularly in the insulin-requiring patients.

Aged↗

New devices for percutaneous coronary intervention are rapidly making bypass surgery obsolete.

PURPOSE OF REVIEW: This review summarizes recent and cumulative progress in the success, safety, applicability, and durability of percutaneous coronary intervention. RECENT FINDINGS: Improvements in basic percutaneous coronary intervention (PCI) equipment and the availability of bare metal stents in the mid-1990s improved acute procedural success to 98%, reduced the emergency surgery rate to 0.2%, and reduced the incidence of recurrent symptoms due to restenosis at the treated site to 15 to 20%. The recent availability of drug-eluting stents has reduced the in-stent neointimal proliferation that causes restenosis and reduced the incidence of symptomatic recurrence to less than 5%, rivaling that of bypass surgery. The work on better antithrombotic pharmacology, distal embolic protection, and devices for crossing chronic total occlusions will further add to the armamentarium for catheter-based revascularization. SUMMARY: Based on progress over the past decade, PCI has grown to represent about two-thirds of all coronary revascularization (800,000 PCI vs 350,000 bypass surgeries). Recent and ongoing progress will make bypass surgery largely obsolete within the next several years.

Angioplasty, Balloon, Coronary↗

Treatment of coronary stent thrombosis with rheolytic thrombectomy: results from a multicenter experience.

The objective of this study was to assess the feasibility, efficacy, and safety of rheolytic thrombectomy (RT) for treatment of coronary stent thrombosis. Stent thrombosis is an infrequent but potentially devastating complication. Conventional treatment with balloon angioplasty and/or thrombolysis has yielded suboptimal results. RT was used to treat 18 patients (mean age, 62 +/- 8 years; 72% male) with in-stent thrombosis (mean time to stent thrombosis, 2.4 +/- 1.8 days). Device success, procedure success, in-hospital and 30-day major cardiovascular events (MACE) were assessed in the hospital and at 30 days. Device success was obtained in 94% and procedure success was achieved in 100% of patients. Following RT, 11 patients underwent balloon angioplasty and 7 patients received additional stents. TIMI 3 coronary flow was obtained in 94.4% and all (100%) patients achieved either TIMI 2 or 3 coronary flow. The angiographic thrombus area decreased from 113.7 +/- 79 to 5.5 +/- 5.7 mm(2) after RT, and to 0.9 +/- 2.1 mm(2) (P < 0.001) after final treatment. Procedural complications were limited to transient no-reflow in five patients. Only one patient evolved a Q-wave MI. At 30 days of follow-up, no patients suffered death, emergent bypass surgery, or stroke. Our data suggest that the adjunctive use of rheolytic thrombectomy offers improved outcomes compared to prior results of intervention after coronary stent thrombosis and should be strongly considered as a treatment option for this complication.

Aged↗

Safety and effectiveness of stent implantation without predilation for small coronary arteries.

The purpose of this study was to examine the safety and effectiveness of stenting without predilation (direct stenting) in small (< 2.5 mm) coronary arteries. Clinical and angiographic data from the multicenter randomized PREDICT trial was examined. Direct stenting was performed on 42 small and 158 large vessels. Predilation was performed prior to stenting for 37 small vessels. In the small-vessel group, mean reference vessel diameter was 2.24 +/- 0.19 mm for direct stenting vs. 2.24 +/- 0.22 mm for predilation (P = NS). Mean reference vessel diameter was 3.17 +/- 0.48 mm in the large-vessel group. Device success for direct stenting was similar for small vs. large vessels (90.5% vs. 92.4%; P = NS). At 180 days, a trend toward increased MACE between small vs. large vessels in the direct-stenting group was observed (26.8% vs.16.7%; P = NS), and significantly higher target lesion revascularizations (TLRs) in the small-vessel group (19.5% vs.7.7%; P = 0.03) were observed. In small vessels, differences in device success rate (90.5% vs. 100 %; P = NS) and lesion success rate (100% vs. 100%; P = NS) for direct stenting vs. predilation were not significant. At 180 days, no differences between direct stenting and predilation for MACE (26.8% vs. 29.7%; P = NS) or TLR (22.0% vs. 21.6%; P = NS) were seen in small vessels, although binary angiographic restenosis rate tended to be higher in direct-stenting group (38.2% vs. 18.5%; P = NS). Direct stenting of small vessels can be performed safely and successfully in selected cases. Restenosis rates may be higher for small vessel treated by direct stenting compared to predilation.

Aged↗

Clinical restenosis after coronary stenting: perspectives from multicenter clinical trials.

OBJECTIVES: We sought to evaluate clinical restenosis in a large population of patients who had undergone coronary stent placement. BACKGROUND: One-year success after coronary stenting is limited mainly by restenosis of and requirement for repeat revascularization of the treated lesion. We studied 6,186 patients (6,219 lesions) pooled from several recently completed coronary stent trials. Clinical restenosis was defined using three different definitions: target lesion revascularization (TLR) beyond 30 days, target vessel revascularization (TVR) beyond 30 days, and target vessel failure (TVF), defined as TVR, any death, or myocardial infarction (MI) of the target vessel territory after hospital discharge. RESULTS: By one year, 638 (12.2%) patients had TLR, 748 (14.3%) had TVR, and 848 (16.0%) had TVF, more than two-thirds higher than the rate of these end points at six months. The severity of angiographic restenosis (> or =50% follow-up diameter stenosis [DS]) in 419 of 1,437 (29%) patients undergoing routine angiographic follow-up correlated directly with the likelihood of TLR (73% vs. 26% for >70% DS compared with <60% DS). Smaller pretreatment minimum lumen diameter (MLD), smaller final MLD, longer stent length, diabetes mellitus, unstable angina, and hypertension were independent predictors of TLR. Prior MI and current smoking were negative predictors. CONCLUSIONS: At one year after stenting, most clinical restenosis reflected TLR, which was predicted by the same variables previously associated with an increased risk of angiographic restenosis. The lower absolute rate of clinical restenosis relative to angiographic restenosis was due to infrequent TLR in lesions with less severe (<60% DS) angiographic renarrowing.

Angioplasty, Balloon↗

Induction of mild systemic hypothermia with endovascular cooling during primary percutaneous coronary intervention for acute myocardial infarction.

OBJECTIVES: The purpose of this study was to evaluate the safety and feasibility of endovascular cooling during primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI). BACKGROUND: In experimental models of AMI, mild systemic hypothermia has been shown to reduce metabolic demand and limit infarct size. METHODS: In a multi-center study, 42 patients with AMI (<6 h from symptom onset) were randomized to primary PCI with or without endovascular cooling (target core temperature 33 degrees C). Cooling was maintained for 3 h after reperfusion. Skin warming, oral buspirone, and intravenous meperidine were used to reduce the shivering threshold. The primary end point was major adverse cardiac events at 30 days. Infarct size at 30 days was measured using (99m)Tc-sestamibi SPECT imaging. RESULTS: Endovascular cooling was performed successfully in 20 patients (95%). All achieved a core temperature below 34 degrees C (mean target temperature 33.2 +/- 0.9 degrees C). The mean temperature at reperfusion was 34.7 +/- 0.9 degrees C. Cooling was well tolerated, with no hemodynamic instability or increase in arrhythmia. Nine patients experienced mild episodic shivering. Major adverse cardiac events occurred in 0% vs. 10% (p = NS) of treated versus control patients. The median infarct size was non-significantly smaller in patients who received cooling compared with the control group (2% vs. 8% of the left ventricle, p = 0.80). CONCLUSIONS: Endovascular cooling can be performed safely as an adjunct to primary PCI for AMI. Further clinical trials are required to determine whether induction of mild systemic hypothermia with endovascular cooling will limit infarct size in patients undergoing reperfusion therapy.

Adult↗

Effectiveness of rheolytic coronary thrombectomy with the AngioJet catheter.

Thrombus-filled lesions are associated with a higher rate of acute complications and long-term restenosis following conventional coronary or saphenous vein graft (SVG) intervention. To evaluate the clinical effectiveness of rheolytic thrombectomy in a nonselected population in the glycoprotein IIb/IIIa blockade era, we reviewed clinical, angiographic, and procedural data on 119 patients who underwent 126 consecutive coronary AngioJet procedures (29% in SVGs, and 71% in native coronary arteries) from July 1998 to August 2000. Glycoprotein IIb/IIIa blockers were used in 88%. Most vessels (68% of SVGs, 74% of native coronary arteries) were occluded initially. Complete or substantial removal of filling defects was achieved in 76% of SVGs and 66% of native coronary cases. The AngioJet rheolytic thrombectomy device led to significant improvement in lumen diameter and Thrombolysis In Myocardial Infarction (TIMI) flow, with reduction in the thrombotic lesion length (p <0.05). Angiographic success (<30% residual stenosis, TIMI-3) was attained in 73% of SVGs and 87% of native coronary procedures. Distal embolization occurred in 13 cases, and was less likely to occur in patients treated with abciximab (0%) compared with patients treated with other glycoprotein IIb/IIIa blockers or heparin alone (17%, p = 0.02). A favorable response to the AngioJet (odds ratio 3.9) and freedom from embolization (odds ratio 14.6) were associated with a higher procedural success rate. In-hospital and long-term clinical outcomes were favorable. Thus, rheolytic thrombectomy resulted in significant reduction of the thrombus burden in most patients, restored TIMI-3 flow, and led to favorable short- and long-term outcomes.

Age Factors↗

Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts.

BACKGROUND: Stents provide effective treatment for stenotic saphenous venous aorto-coronary bypass grafts, but their placement carries a 20% incidence of procedure-related complications, which potentially are related to the distal embolization of atherosclerotic debris. We report the first multicenter randomized trial to evaluate use of a distal embolic protection device during stenting of such lesions. METHODS AND RESULTS: Of 801 eligible patients, 406 were randomly assigned to stent placement over the shaft of the distal protection device, and 395 were assigned to stent placement over a conventional 0.014-inch angioplasty guidewire (control group). The primary end point-a composite of death, myocardial infarction, emergency bypass, or target lesion revascularization by 30 days-was observed in 65 patients (16.5%) assigned to the control group and 39 patients (9.6%) assigned to the embolic protection device (P=0.004). This 42% relative reduction in major adverse cardiac events was driven by myocardial infarction (8.6% versus 14.7%, P=0.008) and "no-reflow" phenomenon (3% versus 9%, P=0.02). Clinical benefit was seen even when platelet glycoprotein IIb/IIIa receptor blockers were administered (61% of patients), with composite end points occurring in 10.7% of protection device patients versus 19.4% of control patients (P=0.008). CONCLUSIONS: Use of this distal protection device during stenting of stenotic venous grafts was associated with a highly significant reduction in major adverse events compared with stenting over a conventional angioplasty guidewire. This demonstrates the importance of distal embolization in causing major adverse cardiac events and the value of embolic protection devices in preventing such complications.

Aged↗