Contactless magnetocardiographic mapping in anesthetized Wistar rats: evidence of age-related changes of cardiac electrical activity.

Magnetocardiography (MCG) is the recording of the magnetic field (MF) generated by cardiac electrophysiological activity. Because it is a contactless method, MCG is ideal for noninvasive cardiac mapping of small experimental animals. The aim of this study was to assess age-related changes of cardiac intervals and ventricular repolarization (VR) maps in intact rats by means of MCG mapping. Twenty-four adult Wistar rats (12 male and 12 female) were studied, under anesthesia, with the same unshielded 36-channel MCG instrumentation used for clinical recordings. Two sets of measurements were obtained from each animal: 1) at 5 mo of age (297.5 +/- 21 g body wt) and 2) at 14 mo of age (516.8 +/- 180 g body wt). RR and PR intervals, QRS segment, and QTpeak, QTend, JTpeak, JTend, and Tpeak-end were measured from MCG waveforms. MCG imaging was automatically obtained as MF maps and as inverse localization of cardiac sources with equivalent current dipole and effective magnetic dipole models. After 300 s of continuous recording were averaged, the signal-to-noise ratio was adequate for study of atrial and ventricular MF maps and for three-dimensional localization of the underlying cardiac sources. Clear-cut age-related differences in VR duration were demonstrated by significantly longer QTend, JTend, and Tpeak-end in older Wistar rats. Reproducible multisite noninvasive cardiac mapping of anesthetized rats is simpler with MCG methodology than with ECG recording. In addition, MCG mapping provides new information based on quantitative analysis of MF and equivalent sources. In this study, statistically significant age-dependent variations in VR intervals were found.

Adaptation, Physiological↗

Multichannel mapping of fetal magnetocardiogram in an unshielded hospital setting.

OBJECTIVES: To evaluate the feasibility of unshielded in-hospital multichannel mapping of fetal magnetocardiogram (FMCG), with a 36-channel system for standard adult magnetocardiographic (MCG) recordings, and its reliability according to the recommended standards for FMCG. METHODS: FMCG was ambulatory mapped with a 36-channel MCG system, in six normal pregnancies at different gestational ages. MCG analysis included adaptive digital filtering of 50 Hz, signal averaging, reconstruction of magnetic field distribution (MFD) and source localization. Fixed Point Independent Component Analysis algorithm (FastICA) was used to reconstruct the FMCG, separating them from maternal contamination and noise. RESULTS: The quality of FMCG recorded after the 32nd gestational week and reconstructed with FastICA was close to FMCG obtained in shielded rooms, and good enough to measure cardiac intervals and heart rate variability parameters. In two cases, reconstruction of the MFD during the QRS allowed three-dimensional localization of ventricular sources. CONCLUSIONS: A first demonstration has been given that multichannel mapping of FMCG can be performed in unshielded clinical environments, with resolution good enough for contactless assessment of fetal cardiac electrophysiology. FastICA processing on unshielded FMCG, recorded after the 32nd week, provided beat-to-beat analysis and heart rate variability assessment. Further work is needed to improve signal reconstruction in early pregnancy.

Adult↗

Clinical application of magnetocardiography.

Magnetocardiography is a noninvasive contactless method to measure the magnetic field generated by the same ionic currents that create the electrocardiogram. The time course of magnetocardiographic and electrocardiographic signals are similar. However, compared with surface potential recordings, multichannel magnetocardiographic mapping (MMCG) is a faster and contactless method for 3D imaging and localization of cardiac electrophysiologic phenomena with higher spatial and temporal resolution. For more than a decade, MMCG has been mostly confined to magnetically shielded rooms and considered to be at most an interesting matter for research activity. Nevertheless, an increasing number of papers have documented that magnetocardiography can also be useful to improve diagnostic accuracy. Most recently, the development of standardized instrumentations for unshielded MMCG, and its ease of use and reliability even in emergency rooms has triggered a new interest from clinicians for magnetocardiography, leading to several new installations of unshielded systems worldwide. In this review, clinical applications of magnetocardiography are summarized, focusing on major milestones, recent results of multicenter clinical trials and indicators of future developments.

Arrhythmias, Cardiac↗

Treating chronic anal fissure with botulinum neurotoxin.

Recent reports confirm that the management of chronic anal fissure has undergone extensive re-evaluation during the past few years. This rejuvenation of interest is attributable to the application of neurochemical treatment, which has contributed to the tendency to treat the disease on an outpatient basis. The use of botulinum neurotoxin seems to be a promising and safe approach for the treatment of chronic anal fissure, particularly in patients at high risk for incontinence. Indeed, botulinum neurotoxin has been successfully used selectively to weaken the internal anal sphincter as a treatment for chronic anal fissure. It is also more efficacious than nitrate therapy, and is not related to the patient's willingness to complete treatment.

Botulinum Toxins↗

Concentric remodeling detection by magnetocardiography in patients with recent onset arterial hypertension.

The aim of this work was to evaluate a number of magnetocardiographic (MCG) indices in their predictive ability for left ventricular (LV) concentric remodeling. Twenty-five male patients affected by essential hypertension for no longer than 15 months and presenting signs of LV remodeling participated in the study; 25 normal men volunteers of comparable age were evaluated as controls. All participants underwent echocardiography (ECHO), electrocardiography (ECG), and magnetocardiography (MCG). Several MCG based indices were evaluated, namely the QRS Integral, T Integral, QRS-T Integral, T/QRS Integral, RS Index, and the variations of the electrical cardiac axis (ECA) orientation. MCG indices were compared with ECHO parameters, i.e., left ventricular mass index (LVMI) and relative wall thickness (RWT), and with ECG parameters, i.e., 12-lead standard ECG LVH Sokolow-Lyon and Cornell voltages. QRS Integral values for patients and controls were significantly different (P = 0.03), whereas T Integral values showed only a tendency to differentiate between patients and controls (P = 0.15). No significant correlation between MCG and echocardiographic indices in patients was found; RWT showed a tendency to correlate with QRS Integral (r = 0.34, P = 0.17) and with RS Index (r = 0.49, P = 0.15), and LVMI showed a tendency to correlate with the variations of the ECA orientation (r = 0.38, P = 0.10). Our findings, also supported by preliminary results on patients affected by hypertension induced LV hypertrophy, suggest a potential role of MCG in the evaluation of early electrophysiological alterations due to LV concentric remodeling.

Adult↗

Characterization of fetal arrhythmias by means of fetal magnetocardiography in three cases of difficult ultrasonographic imaging.

Characterization of ultrasound detected fetal arrhythmias is generally performed by means of M-mode and pulsed Doppler echocardiography (fECHO), sonographic techniques that allow only indirect and approximate reconstruction of the true electrophysiological events that occur in the fetal heart. Several studies demonstrated the ability of fetal magnetocardiography (fMCG) to identify fetal arrhythmias. We report on three women, studied after the 32nd gestational week, who were referred for fMCG because of unsatisfying fetal cardiac visualization with fECHO due to maternal obesity, fetus in constant dorsal position hiding the fetal heart, intrauterine growth retardation, and oligohydramnios. Minor pericardial effusion was present in the third patient and digoxin therapy was given. FMCG were recorded with a 77-channel MCG system working in a shielded room. Independent Component Analysis (FastICA algorithm) was used to reconstruct fetal signals. The good quality of the retrieved fetal signals allowed real-time detection of arrhythmias and their classification as supraventricular extrasystoles (SVE), with/without aberrant ventricular conduction and/or atrioventricular block. The time course of the fetal cardiac rhythm was reconstructed for the entire recording duration; hence, fetal heart rate variability could be studied in time and frequency. Since isolated extrasystoles may progress to more hazardous supraventricular tachycardias, the noninvasive antenatal characterization of, even transient, fetal arrhythmias and their monitoring during pregnancy can be of great clinical impact.

Adult↗

Contactless magnetocardiographic study of ventricular repolarization in intact Wistar rats: evidence of gender-related differences.

INTRODUCTION: Magnetocardiographic (MCG) mapping is increasingly used for the non-invasive study of coronary artery disease (CAD), cardiomyopathy (CMP) and arrhythmias. MCG study of small animals with ischemia or CMP would provide useful experimental models for the interpretation of abnormal human patterns. The aim of this study was to assess the range of normality of MCG ventricular repolarization parameters, in intact adult rats. METHODS AND RESULTS: 10 adult Wistar rats (weight 250 - 350 grams) were investigated with a 36-channel MCG mapping instrumentation (sensitivity is 20 fT/ radical Hz, at 1 Hz), designed for clinical recordings in unshielded hospital laboratories. To assess ventricular repolarization, MCG Q-T(peak), Q-T(end), J-T(peak), J-T(end), T(peak)-T(end) intervals were measured. MCG imaging was obtained by automatic calculation of isofield contour maps, and with inverse source localization based on the Equivalent Current Dipole and Effective Magnetic Dipole models, in a semi-infinite space with homogeneous conductance. Magnetic field (MF) orientation, dynamics and stability during the J-T(end) segment were also calculated. After averaging 300 s of continuous MCG recording, the S/N ratio was good enough for reproducible reconstruction of both atrial and ventricular magnetic maps and for three-dimensional localization of the underlying cardiac generators. Clear gender-related differences in ventricular repolarization duration were found, evidenced by significantly longer Q-T(end), J-T(end) and T(peak)-T(end) intervals in females. The differences in MF orientation, and stability during the J-T(end) segment were not significant. For J-T(peak) MF dynamics, only the ratio between the strengths of the positive and negative poles was significantly lower in the female group ( p < 0.05). CONCLUSIONS: Contactless MCG recording is a novel approach, which simplifies non-invasive mapping in small animals. In normal rats, gender-related differences of ventricular repolarization parameters equivalent to those reported in previous ECG studies were demonstrated.

Animals↗

Phantom validation of multichannel magnetocardiography source localization.

Multichannel magnetocardiography (MMCG) is used clinically for noninvasive localization of the site of origin of cardiac arrhythmias. However, its accuracy in unshielded environments is still unknown. The aim of this study was to test the accuracy of three-dimensional localization of intracardiac sources by means of MMCG in an unshielded catheterization laboratory using a saline-filled phantom, together with a nonmagnetic catheter designed for multiple monophasic action potential recordings in a clinical setting. A nine-channel direct current superconducting quantum interference device (DC-SQUID) system (sensitivity fT/Hz0.5) was used for MMCG from 36 points in a measuring area of 20 x 20 cm. The artificial sources to be localized were dipoles embedded in the distal end of the catheter, placed 12 cm below the sensor's plane. Equivalent current dipoles, effective magnetic dipoles, and distributed currents models were used for the inverse solution. The localization error was estimated as the three-dimensional difference between the physical position of the tip of the catheter and the three-dimensional localization of the dipoles derived by means of the inverse solution calculated from MMCG data. The reproducibility was tested by repeating the MMCG after repositioning the phantom and the measurement system. The average location error of the catheter dipole was 9 +/- 4 mm and was due primarily to imprecise depth estimation. Localization was reproducible within 0.73 mm. The distributed currents model provided an accurate image of current distribution centered over the catheter tip. The authors conclude that MMCG estimation is accurate enough to guarantee proper localization of cardiac dipolar sources even in an unshielded clinical electrophysiological laboratory.

Arrhythmias, Cardiac↗

Noninvasive study of ventricular preexcitation using multichannel magnetocardiography.

In clinical practice, noninvasive classification of ventricular preexcitation (VPX) is usually done with ECG algorithms, which provide only a qualitative localization of accessory pathways. Since 1984, single or multichannel magnetocardiography (MMCG) has been used for three-dimensional localization of VPX sites, but a systematic study comparing the results of ECG and MMCG methods was lacking. This study evaluated the reliability of MMCG in an unshielded electrophysiological catheterization laboratory, and compared VPX classification as achieved with the five most recent ECG algorithms with that obtained by MMCG mapping and imaging techniques. A nine-channel direct current superconducting quantum interference device (DC-SQUID) MMCG system (sensitivity is 20 fT/Hz0.5) was used for sequential MMCG from 36 points on the anterior chest wall, within an area 20 x 20 cm. Twenty-eight patients with Wolff-Parkinson-White syndrome were examined at least twice, on the same day or after several months to test the reproducibility of the measurements. In eight patients, the reproducibility of MMCG was also evaluated using different MCG instrumentation during maximal VPX and/or atrioventricular reentrant tachycardia induced by transesophageal atrial pacing via a nonmagnetic catheter. The results of VPX localization with ECG algorithms and MMCG were compared. Equivalent current dipole, effective magnetic dipole, and distributed currents imaging models were used for the inverse solution. MMCG classification of VPX was found to be more accurate than ECG methods, and also provided additional information for the identification of paraseptal pathways. Furthermore, in patients with complex activation patterns during the delta wave, distributed currents imaging revealed two different activation patterns, suggesting the existence of multiple accessory pathways.

Algorithms↗

Magnetocardiography: current status and perspectives. Part I: Physical principles and instrumentation.

Magnetocardiography (MCG) is a non-invasive and risk-free technique allowing body surface recording of the magnetic fields generated by the electrical activity of the heart. The MCG recording system allows spatially and temporally accurate measurements of the very weak magnetic fields produced by currents flowing within myocardial fibers during cardiac activity. MCG has now been around for over 30 years, but only recently has progress in instrumentation put the technique on the verge of clinical applicability. This review summarizes the physical principles, instrumentation, main clinical applications and perspectives for the clinical use of MCG. This first part is devoted to the description of the physical principles and instrumentation.

Body Surface Potential Mapping↗

Magnetocardiography: current status and perspectives. Part II: Clinical applications.

Magnetocardiography (MCG) is a non-invasive and risk-free technique allowing body surface recording of the magnetic fields generated by the electrical activity of the heart. The MCG recording system allows spatially and temporally accurate measurements of the very weak magnetic fields produced by currents flowing within myocardial fibers during cardiac activity. MCG has now been around for over 30 years, but only recently has progress in instrumentation put the technique on the verge of clinical applicability. This review summarizes the physical principles, instrumentation, main clinical applications and perspectives for the clinical use of MCG. This second part is devoted to the description of the main current clinical applications and perspectives.

Arrhythmias, Cardiac↗

Radiofrequency ablation of hepatic tissue: a new experimental animal model.

BACKGROUND/AIMS: Experimental radiofrequency ablation has already been performed in healthy livers of porcine models, but not in less expensive and easy-to-manage rats, with devices capable of delivering radiofrequency ablation in the 20-30 g liver of such small animals being so far unavailable. METHODOLOGY: We experimented with a modified system of radiofrequency ablation of liver tissue in rat models developing a custom-made needle-microelectrode of very small dimensions (0.3x2 mm) and an electrode-tip cooling technique, based on saline solution infusion. We adjusted duration (seconds) and power (watts) of radiofrequency ablation letting them range between 5-50 seconds and 5-25 W, respectively, to obtain the greatest lesions with the least side effects. After sacrificing the animals, an accurate histological examination of the liver was made. RESULTS: It is possible to establish beforehand the diameter of thermal liver lesion on the basis of joules of applied energy. The greatest increase of liver thermal lesion diameter (8 mm) is obtained with a 250-joule (10 W for 25 seconds) thermal energy cooling the electrode-tissue interface. CONCLUSIONS: Experimental radiofrequency ablation in rat liver is an effective and cheap way to study its effects on healthy hepatic tissues. It might be the first step to treat experimentally caused liver tumors.

Animals↗