PubMed Health⌕ Search

PubMed · 12687859

Phantom validation of multichannel magnetocardiography source localization.

Abstract

Multichannel magnetocardiography (MMCG) is used clinically for noninvasive localization of the site of origin of cardiac arrhythmias. However, its accuracy in unshielded environments is still unknown. The aim of this study was to test the accuracy of three-dimensional localization of intracardiac sources by means of MMCG in an unshielded catheterization laboratory using a saline-filled phantom, together with a nonmagnetic catheter designed for multiple monophasic action potential recordings in a clinical setting. A nine-channel direct current superconducting quantum interference device (DC-SQUID) system (sensitivity fT/Hz0.5) was used for MMCG from 36 points in a measuring area of 20 x 20 cm. The artificial sources to be localized were dipoles embedded in the distal end of the catheter, placed 12 cm below the sensor's plane. Equivalent current dipoles, effective magnetic dipoles, and distributed currents models were used for the inverse solution. The localization error was estimated as the three-dimensional difference between the physical position of the tip of the catheter and the three-dimensional localization of the dipoles derived by means of the inverse solution calculated from MMCG data. The reproducibility was tested by repeating the MMCG after repositioning the phantom and the measurement system. The average location error of the catheter dipole was 9 +/- 4 mm and was due primarily to imprecise depth estimation. Localization was reproducible within 0.73 mm. The distributed currents model provided an accurate image of current distribution centered over the catheter tip. The authors conclude that MMCG estimation is accurate enough to guarantee proper localization of cardiac dipolar sources even in an unshielded clinical electrophysiological laboratory.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Riccardo Fenici, Donatella Brisinda, Jukka Nenonen, Peter Fenici. 2003. Phantom validation of multichannel magnetocardiography source localization.. https://doi.org/10.1046/j.1460-9592.2003.00063.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Safety of nerve conduction studies in patients with implanted cardiac devices.

Patients with implanted cardiac devices and their physicians may defer important electrodiagnostic testing because of anxiety about potential negative effects on the device. To determine the safety of routine nerve conduction studies (NCS) in this population, 10 patients with permanent dual-chamber pacemakers of various types and five patients with implanted cardiac defibrillators (ICD) underwent nerve stimulation at sites commonly used during NCS. The implanted cardiac device was interrogated before and after the study and there was continuous monitoring of the surface electrocardiogram (ECG) and atrial and ventricular electrograms. Electrical impulses generated during routine NCS were never detected by the sensing amplifier and did not affect the programmed settings of the implanted cardiac device. We conclude that routine NCS is safe in patients with implanted cardiac pacemakers with bipolar sensing configurations and defibrillators.

Arrhythmias, Cardiac↗

[Pulmonary diseases and heart function].

The most severe cardiac sequel to lung disease is the load on the right ventricle due to pulmonary hypertension with the development of a cor pulmonale. This is characterized by hypertrophy and/or dilatation of the right ventricle because of a primary impairment of lung function and/or lung structure. The most important pathomechanisms for the development of pulmonary hypertension are vessel obliteration, mechanical lesions, primary vascular or extra-vascular inflammation and hypoxic vasoconstriction. Chronic obstructive pulmonary disease (COPD) is one of the most important reasons for chronic cor pulmonale. A further very common reason is obstructive sleep apnea syndrome, especially if combined with a COPD. In this case, the prevalence of cor pulmonale can reach 80%. The development of a chronic cor pulmonale is the most striking negative prognostic factor for these patients. Only 30% of COPD patients with cor pulmonale survive longer than 5 years, and only early detection of the disturbances to respiration which might potentially lead to cor pulmonale and their subsequent therapy are able to improve the patient's prognosis. Furthermore, pulmonary diseases may also have an impact on the left heart side in terms of an impairment of left heart function or by inducing severe arrhythmias . Thus, lung diseases may have both a significant impact on right and left heart performance.

Arrhythmias, Cardiac↗